Operating Manual<br />

3.4 Inputs HV on 24 V DC<br />

Stage 1 24 V DC<br />

Stage 2 24 V DC<br />

Stage 3 24 V DC<br />

Stage 4 24 V DC<br />

Stage 5 ( analog ) 24 V DC<br />

I or U operation 24 V DC<br />

3.5 Outputs<br />

Analog outputs for<br />

instruments<br />

Inputs for analog setting of nominal value<br />

U nom<br />

0 ... 10 V DC equals<br />

0 ... 100 kV<br />

I 0 ... 10 V DC equals<br />

nom<br />

0 ... 1 mA<br />

du or di / dt 0 ... 10 V DC equals<br />

0 ... 100 kV/s<br />

or 0 ... 1mA /s<br />

Fault: 24V DC max 100mA<br />

Release: 24V DC max 100mA<br />

Pre-warning: 24V DC max 100mA<br />

HV on 24V DC max 100mA<br />

Earth reversing switch 24V DC max 100 mA,<br />

adjustable disconnection<br />

delay between 0,1and 5s<br />

U act<br />

I act<br />

0 ... 10 VDC equals<br />

0 ... 100kV<br />

(Ri>100kOhm)<br />

0 ... 10 VDC equals<br />

0 ... 1mA<br />

(Ri >100kOhm)<br />

Nr. 81<strong>01</strong>23BE_02/00<br />