Frequency Inverters<br />

Inverters 0,37..2,2kW, IP20, NXL Compact<br />

Speed and/or torque controller for induction motors. EMC and LVD compliant with external filters.<br />

The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To<br />

control pumps and fans for heating, ventilation and air conditioning systems, normally Low Overload<br />

ratings are used. Industrial or process installations normally require High Overload ratings.<br />

Features 1 all-round software package included<br />

start-up wizard<br />

flexible I/O configuration; 1 free slot<br />

inputs/outputs: 2 analog inputs, 3 digital inputs, 1 relay,<br />

1 analog output<br />

Series NXL Compact<br />

RFI-filter optional<br />

Output frequency 0 ... 320 Hz<br />

Frequency resolution 0,01 Hz<br />

Serial communication Modbus RTU as standard; optional: LonWorks, Profibus DP,<br />

BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen<br />

Immunity fulfills all EMC immunity requirements<br />

Emissions EN61800-3 (category C2) with optional filters<br />

Safety EN50178, EN60204-1, EN60950, IEC61800-5, CE, UL, cUL<br />

Protection class IP20<br />

208..240V, 1/3 phases<br />

Voltage Low overload<br />

(for Fan/Pump)<br />

380..500V, 3 phases<br />

Low overload<br />

Icont<br />

High overload<br />

(for Machines)<br />

High overload<br />

Icont<br />

NXL Compact RFI filters (EN61800-3 category C2)<br />

7-4 http://products.ecc.emea.honeywell.com/europe<br />

Brake<br />

chopper<br />

1 phase<br />

input<br />

3 phases<br />

input<br />

kW A kW A<br />

230V 0,37 2,4 0,25 1,7 – – NXL0002V32C1N0<br />

230V 0,75 3,7 0,55 2,8 integrated NXL0003V32C1N1<br />

230V 1,1 4,8 0,75 3,7 integrated NXL0004V32C1N1<br />

230V 1,5 6,6 1,1 4,8 integrated NXL0006V32C1N1<br />

Voltage Low overload<br />

(for Fan/Pump)<br />

Low overload<br />

Icont<br />

High overload<br />

(for Machines)<br />

High overload<br />

Icont<br />

Brake<br />

chopper<br />

1 phase<br />

input<br />

3 phases<br />

input<br />

kW A kW A<br />

400V 0,55 1,9 0,37 1,3 – – NXL0001V35C1N0<br />

400V 0,75 2,4 0,55 1,9 – – NXL0002V35C1N0<br />

400V 1,1 3,3 0,75 2,4 integrated – NXL0003V35C1N1<br />

400V 1,5 4,3 1,1 3,3 integrated – NXL0004V35C1N1<br />

400V 2,2 5,4 1,5 4,3 integrated – NXL0005V35C1N1<br />

RFI filter (1 phase input)for 208..240V models; H-level<br />

RFI filter for 380..500V models; H-level<br />

Type<br />

Type<br />

NXLRFIV12<br />

NXLRFIV35