Thermostatic Mixing Valves<br />

21-16<br />

Thermostatic mixing valve with scald protection for solar installations, TM200SOLAR<br />

Thermostatic mixing valves of this type are used for central regulation of the water temperature in<br />

solar-powered, bivalent water heaters.<br />

A cold water break can be fitted in the circulation line in water heater systems, which prevents cold<br />

water from mixing at the extraction point via the circulation line.<br />

Media Water<br />

Body material brass, dezincification resistant<br />

Body finishing nickel plated<br />

Port connection type external threads<br />

Max. media temperature 110 oC Temp. setpoint range 30 ... 60 oC Additional description Highly sensitive thermal element with good all-round watertemperature<br />

sensing, even at low flow rates<br />

Simple setting of the required water temperature<br />

Scald protection - the hot water inlet is automatically cut off if the<br />

cold supply fails provided that the hot water inlet tempe-rature is<br />

at least 10 K higher than that of mixed water setting<br />

The cold water inlet is automatically cut off if the hot supply fails<br />

Meets KTW recommendations for potable water<br />

Inner components are of scale-resistant materials<br />

With threaded union connectors<br />

Without connection fittings<br />

Thermostatic mixing valve with scald protection, TM300<br />

TM300 thermostatic mixing valves provide control of the water temperature and are used: - For<br />

centralised control on hot water supply units or for localised control adjacent to point-use outlets. Or<br />

for use with solar-heated hot water units with dual energy source. - In heating systems with underfloor<br />

heating or for limiting boiler return temperatures. Where a system includes a hot water circulation<br />

circuit, a KB191 return flow retarder unit (see accessories) must be fitted to prevent cold water<br />

backfeeding and cooling the mixed water at the outlets.<br />

http://products.ecc.emea.honeywell.com/europe<br />

Type<br />

TM200SOLAR-3/4A<br />

Type<br />

TM200SOLAR-3/4E<br />

Media Water<br />

Body material brass<br />

Port connection type coupling compressing fitting<br />

Max. media temperature 90 oC Temp. setpoint range 30 ... 60 oC Additional description Highly sensitive thermal element with good all-round water<br />

temperature sensing, even at low flow rates<br />

Simple setting of the required water temperature<br />

Scald protection - the hot water inlet is automatically cut off if the<br />

cold supply fails provided that the hot water inlet temperature is at<br />

least 10 K higher than that of mixed water setting<br />

The cold water inlet is automatically cut off if the hot supply fails<br />

Inner components are of scale-resistant materials<br />

With inlet check valves