Safety Groups<br />

21-6<br />

Accessories<br />

Pressure gauge with housing diameter 50 mm, connecting pin above G 1/4,<br />

range 0 - 16 bar<br />

Pressure reducing valve for completion of the safety group SG150 with connection<br />

size 1/2"<br />

Pressure reducing valve for completion of the safety group SG150 with connection<br />

size 3/4"<br />

Connection set with 1/2" threaded male connections<br />

Connection set with 3/4" threaded male connections<br />

Connection set with 1/2" solder connections<br />

Connection set with 3/4" solder connections<br />

Spare Parts<br />

Discharge tundish<br />

Plug with O-ring R1/4" (packs of 5)<br />

Safety valve insert, set pressure 6 bar<br />

Safety valve insert, set pressure 6 bar<br />

Safety valve insert, set pressure 8 bar<br />

Safety valve insert, set pressure 8 bar<br />

Safety valve insert, set pressure 10 bar<br />

Safety valve insert, set pressure 10 bar<br />

Check valve insert for safety valves 1/2"<br />

Check valve insert for safety valves 3/4"<br />

Safety groups of this type are used to protect pressurised water heaters according to the requirements<br />

of DIN 4753, Part 1, DIN 1988 and DIN EN1488.<br />

They are compact appliances which incorporate all the necessary safety devices such as check valve,<br />

shutoff valve, test point, diaphragm type safety valve and pressure reducing valve in one unit. The<br />

safety valve protects the downstream cylinder, pressure vessel etc. by automatically opening when<br />

excess pressure occurs. The check valve prevents back pressure, backflow and back syphonage of<br />

water from the hot water unit. In addition, a balanced seat pressure reducing valve is fitted on the inlet<br />

to control the supply pressure to that required for the system.<br />

Approvals DVGW-approval requested<br />

Media Water<br />

Body material brass, dezincification resistant<br />

Max. media temperature 40 o C<br />

Pressure setpoint range 1,5 ... 6 bar<br />

Setpoint scale yes<br />

Transparant strainer chamber yes<br />

Balanced seat design yes<br />

Additional description For closed hot water storage units up to 200 litres according to DIN<br />

4753 Part 1 and DIN 1988. Tested to TRD 721 for 1.0 to 10.0 bar<br />

pressure range.<br />

Fully approved for noise level protection to class 1<br />

Replacement insert tested to TRD 721<br />

Pressure reducing valve with inlet pressure balancing - inlet<br />

pressure fluctuation does not influence the outlet pressure<br />

Easy venting<br />

Meets KTW recommendations for potable water<br />

With threaded male connections, set pressure 6,0 bar<br />

http://products.ecc.emea.honeywell.com/europe<br />

M08M16<br />

D150-1/2<br />

D160S-3/4<br />

VST06-1/2A<br />

VST06-3/4A<br />

VST06-1/2B<br />

VST06-3/4B<br />

TA160S<br />

S06K-1/4<br />

A152-1/2AA<br />

A152-3/4AA<br />

A152-1/2AB<br />

A152-3/4AB<br />

A152-1/2AC<br />

A152-3/4AC<br />

2166200<br />

2110200<br />

Safety group with interchangeable safety valve insert and pressure reducing valve,<br />

SG150D<br />

Port connection type Port diameter (inch) DN size (mm) Set pressure (bar) Type<br />

external threads 1/2 15 6 SG150D-1/2AA<br />

external threads 3/4 20 6 SG150D-3/4AA