4.3.3. Specify module configuration data<br />
Connect the <strong>2577</strong> to the <strong>Profibus</strong> network by selecting “CTI <strong>2577</strong> <strong>DP</strong> <strong>Slave</strong> Module” and dragging<br />
the mouse to the <strong>Profibus</strong> network icon. When the left mouse button is released, the module<br />
configuration screen is displayed. This screen allows selection of number of I/O words to access<br />
through the <strong>2577</strong>. Select 32W In/32W Out and press the “OK” button. See figure below.<br />
When I/O words are selected, the <strong>Profibus</strong> Interface screen is displayed. Select the PARAMETERS tab<br />
and enter the <strong>2577</strong> <strong>Profibus</strong> address as shown below.<br />
CTI <strong>2577</strong> Installation and Operation Guide<br />