IV. Mechanical installation<br />

Installation and electrical connection in<br />

the weatherproofed housing may only be<br />

carried out by appropriately qualified<br />

technicians in compliance with latest<br />

VDE standards.<br />

Figure Bild 1<br />

a<br />

V. Connecting the screen heater<br />

Only heaters VHL-H220 / VHB-H220 for<br />

110-265 V are to be used for connection<br />

to the socket in the mains unit.<br />

The heater (d) is pushed into the front<br />

side of the camera tray: a 2-pole plug is<br />

connected to the end of the cable to<br />

match the socket no. 6 in the mains unit.<br />

eneo ® is a reg. trademark of <strong>Videor</strong> Technical E. Hartig GmbH<br />

VIDEOR TECHNICAL E. Hartig GmbH (U.K. Branch)<br />

Unit 14, Campbell Court · Campbell Road, Bramley, Tadley<br />

GB-Hampshire RG26 5EG<br />

Tel. (0 12 56) 88 02 20 · Fax. (0 12 56) 88 00 89<br />

www.eneo-security.com<br />

h<br />

g<br />

Th1<br />

Installation in the VHL and VHB<br />

housing series<br />

As seen in fig. 1, the mains unit is<br />

pushed into the slot in the camera tray<br />

and fastened into place by four screws<br />

(b). The lower insulation plate has not to<br />

be removed.<br />

The mains cable (g) with its L1/N/PE<br />

wires is to be connected to the marked<br />

terminals 1-3. The earth cable (h) is to<br />

be plugged into the PE-point (e) and the<br />

PE-conductor connected coming from<br />

the housing middle section to the<br />

PE-point (f).<br />

The thermostat Th1 (heating accessory)<br />

is to be connected to the terminals<br />

4-5 instead of the wire<br />

jumper. As an alternative<br />

the thermostat Th2 can<br />

be used, which will be<br />

d<br />

fixed on the bottom (insulation<br />

plate) s. fig. 2.<br />

Figure 2<br />

View of the power supply units from<br />

below with fixed thermostat Th2.<br />

# 990498<br />

Technical changes reserved.<br />

© Copyright by VIDEOR TECHNICAL 03/01<br />

VIDEOR TECHNICAL E. Hartig GmbH<br />

Maybachstraße 5 · 63322 Rödermark/Germany<br />

Tel. (0 60 74) 888-0 · Fax. (0 60 74) 888-100