TECHNICAL REFERENCE<br />

OPTICAL TABLES<br />

BREADBOARDS<br />

AND GRID PLATFORMS<br />

HONEYCOMB, GRANITE<br />

AND RIGID STRUCTURES<br />

ISOLATORS<br />

WORKSTATIONS AND<br />

ISOLATED PLATFORMS<br />

STRUCTURAL RAILS<br />

AND CARRIERS<br />

TESTING, ANALYSIS<br />

AND DESIGN<br />

1072<br />

Optical Tables and <strong>Vibration</strong> Control<br />

BenchTop<br />

<strong>Compact</strong> <strong>Pneumatic</strong> <strong>Vibration</strong> <strong>Isolation</strong><br />

<strong>Platform</strong> <strong>with</strong> <strong>Self</strong>-<strong>Leveling</strong><br />

BenchTop <strong>Compact</strong> <strong>Vibration</strong> <strong>Isolation</strong> <strong>Platform</strong>s provide the rock solid performance and<br />

ultra-small packaging that is so critical to today’s life science and disk drive applications.<br />

Exclusive Stabilizer vibration isolation technology, adapted from our acclaimed<br />

Stabilizer Model I-2000 <strong>Vibration</strong> Isolators, is at the heart of the system. This technology<br />

is renowned for compact size, faster settling times, superior high-center-of-mass stability,<br />

lower natural frequency, and a patented, self-centering piston mechanism.<br />

Four isolator modules recessed into the bottom of the platform achieve top-notch table top<br />

vibration isolation. Each contains a pneumatic, flexible rolling diaphragm that supports the<br />

load, thereby decoupling vibrations from the isolated platform. If the platform is disturbed,<br />

the modules automatically relevel the platform using compressed air.<br />

No more bulky canisters to impede instrument access, restrict arm positioning or crowd<br />

workspaces. Newport’s hybrid-chamber design allows all vibration modules to be<br />

completely hidden <strong>with</strong>in the platform.<br />

The BenchTop also minimizes fatigue. That’s because its low profile design adds only<br />

about two inches of height to your support surface. Add optional padded armrests - and<br />

you can work for hours <strong>with</strong> unparalleled ease.<br />

Specifications<br />

Sizes (W x L)<br />

[in. (cm)]<br />

Phone: 1-800-222-6440 • Fax: 1-949-253-1680<br />

• Hybrid chamber/laminar flow design maximizes<br />

isolation bandwidth<br />

• Integrated leveling values improve repositioning<br />

accuracy after disturbance<br />

• Low profile, compact design minimizes footprint<br />

Maximum Recommended<br />

CG Height<br />

[in. (mm)]<br />

20 (50.8) x 24 (61.0) 8 (203.2)<br />

24 (61.0) x 36 (91.4) 11.0 (279.4)<br />

<strong>Platform</strong> Thickness:<br />

Thickness, BenchTop, Standard Laminate [in. (mm)] 2.0 (51)<br />

Thickness, BenchTop, Stainless [in. (mm)] 2.2 (56)<br />

Thickness, BenchTop Stainless, w/holes [in. (mm)] 3.0 (75)<br />

Mounting Holes 1/4-20 on 1 in. centers<br />

(M6-1.0 on 25 mm centers)<br />

Max. Load Range (lb) 175 (80)<br />

Video image of human spinal cord neurons<br />

acquired through a camera/microscope system<br />

placed on a BenchTop unit. Available <strong>with</strong><br />

either plastic laminate or stainless steel tops, the<br />

BenchTop is ideal for providing vibration isolation<br />

in applications involving time lapse photography,<br />

videomicroscopy, probing and manipulation of cells<br />

under high magnification.<br />

TRANSMISSIBILITY (T)<br />

TRANSMISSIBILITY (T)<br />

10<br />

1<br />

0.1<br />

20<br />

0<br />

-20<br />

0.01<br />

1 10<br />

VERTICAL FREQUENCY (Hz)<br />

-40<br />

50<br />

10<br />

1<br />

0.1<br />

0.01<br />

1 10<br />

HORIZONTAL FREQUENCY (Hz)<br />

-40<br />

50<br />

dB<br />

20<br />

0<br />

dB<br />

-20


BenchTop <strong>Isolation</strong> Performance<br />

Optical Tables and <strong>Vibration</strong> Control<br />

Vertical <strong>Isolation</strong>* Horizontal <strong>Isolation</strong>*<br />

Amplification<br />

at Resonance<br />

Maximum<br />

Load per Re-leveling<br />

Res<br />

10Hz<br />

Res<br />

10Hz<br />

Vert<br />

Horz Isolator Accuracy<br />

Model<br />

(Hz)<br />

(%)<br />

(Hz)<br />

(%)<br />

(dB)<br />

(dB) [lb (kg)] [in. (mm)] <strong>Self</strong> Centering<br />

CM-225 3.2 90 3.6 96 12 10 60 (27) 0.025 (0.6) Yes<br />

* Nominal resonance peak, isolation and damping at full rated load<br />

Ordering Information<br />

Isolated Surface<br />

w/ Cleanroom prep.<br />

Size (W x L)<br />

Model<br />

Model<br />

[in. (cm)]<br />

BT-2024 BTC-2024 20 (50.8) x 24 (61.0)<br />

BT-2436 BTC-2436 24 (61.0) x 36 (91.4)<br />

Options and Accessories<br />

Append these codes to the BenchTop model number. For example, the order number for a 24 in. x 36 in. (61.0 x 91.4 cm) BenchTop<br />

<strong>with</strong> a sealed mounting hole stainless steel work surface is BT-2436-OPT 02.<br />

Option Code Description<br />

01 Stainless steel work surface (no mounting holes)<br />

02 Stainless steel work surface (mounting holes)<br />

For metric M6-1.0 sealed mounting holes, add an M- prefix to the order number, for example, M-BT-2436-OPT 02<br />

Accessories<br />

Model (Metric) Description<br />

ACGP Air Compressor, high throughput<br />

ACMP (ACMP-02) Air Compressor, low noise<br />

ARF Air Regulator/Filter<br />

BT-A Armrest<br />

BT-C Cable Manager<br />

Email: sales@newport.com • Web: newport.com<br />

1073<br />

TECHNICAL REFERENCE OPTICAL TABLES BREADBOARDS<br />

HONEYCOMB, GRANITE<br />

AND GRID PLATFORMS AND RIGID STRUCTURES<br />

ISOLATORS WORKSTATIONS AND<br />

ISOLATED PLATFORMS<br />

STRUCTURAL RAILS<br />

AND CARRIERS<br />

TESTING, ANALYSIS<br />

AND DESIGN