2-Phase HSC Counter<br />
Overview<br />
Introduction<br />
2-Phase HSC Modes Overview<br />
The 2-Phase HSC uses the phase difference between two counter signals to<br />
perform count-up or count-down. There are four modes of phase difference:<br />
Mode 0: 2-Phase*4 (see page 39)<br />
Mode 1: Count + Direction (see page 40)<br />
Mode 2: Up + Down (see page 41)<br />
Mode 3: Two Phases*2 (see page 42)<br />
Mode 0 (2-Phase*4):<br />
The counter counts up or down depending on the order of the inputs.<br />
Mode 1 (Count + Direction):<br />
The counter counts up or down depending on the rising edge of one input and the<br />
value of the other input.<br />
Mode 2 (Up + Down):<br />
The counter counts up or down depending on the rising edge of one input and the<br />
value of the other input.<br />
Mode 3 (2-Phase*2):<br />
The counter counts up or down depending on the rising/falling edge of one input<br />
and depending on the order of the inputs.<br />
2-Phase HSC Specification<br />
Specification of this counter is described in the 2-Phase HSC Specification<br />
(see page 43).<br />
38 04/2012