Figure 14-25 Low First Developer Activity<br />

The result<strong>in</strong>g photographic effect is opposite <strong>of</strong> the first<br />

developer activity because this developer controls the<br />

formation <strong>of</strong> the negative image.<br />

B<br />

G<br />

R<br />

F010_0157EC<br />

Are the chemical analyses <strong>of</strong><br />

developer tank <strong>of</strong>f Specs?<br />

Also see Figs.<br />

14-28, -29, -30<br />

NO YES<br />

Are the chemical analyses <strong>of</strong><br />

Developer Replenisher <strong>of</strong>f Specs?<br />

YES<br />

NO<br />

Are the developer physical<br />

measurements <strong>of</strong>f Specs?<br />

NO<br />

YES<br />

High exposure level<br />

(low probability)<br />

Replenisher Rate<br />

Too Low<br />

Replenisher Mix<br />

Error<br />

Developer<br />

Contam<strong>in</strong>ation<br />

Low Agitation<br />

Time Too Short<br />

Temperature<br />

Control<br />

Malfunction<strong>in</strong>g or<br />

Set Too Low<br />

<strong>Effects</strong> <strong>of</strong> <strong>Mechanical</strong> & <strong>Chemical</strong> <strong>Variations</strong> <strong>in</strong> <strong>Process</strong> RVNP 14-29<br />

Check Exposure<br />

Level<br />

Check <strong>and</strong> adjust<br />

Repl. Rate if<br />

necessary<br />

Check Mix<strong>in</strong>g<br />

Procedure<br />

Compare<br />

with fresh<br />

Developer; mix<br />

fresh Developer<br />

Check<br />

Bars/Nozzles for<br />

plugg<strong>in</strong>g; Check<br />

Recirculation<br />

Check <strong>and</strong> Adjust<br />

Parameter if<br />

necessary<br />

Increase Repl.<br />

Rate<br />

Aeration/Oxidation<br />

<strong>of</strong> Solution (low<br />

sulfite)<br />

Mix a Fresh<br />

Solution<br />

Elim<strong>in</strong>ate Source <strong>of</strong><br />

contam<strong>in</strong>ation (<strong>in</strong>cl.<br />

recirculation &<br />

replenisher l<strong>in</strong>es)<br />

Check for Air<br />

Leaks/Foam<strong>in</strong>g<br />

Elim<strong>in</strong>ate<br />

Source <strong>of</strong><br />

Oxidation