20<br />
Functions<br />
Cable 3: Stop dosing input and dosing monitor or dosing output<br />
Useful when the load (e.g. a relay) has one side<br />
connected to a power supply which is not the same one<br />
as connected to the sensor.<br />
When the dosing output is activated, the output<br />
provides the Gnd to the load.<br />
Recommended supply: max. 24 VDC.<br />
Max. current: 100 mA.<br />
Cable 4: Level input<br />
DME and DMS<br />
Number/colour<br />
Function<br />
1/brown 2/white<br />
Plug<br />
3/blue, +5V 4/black, GND 5/grey<br />
Type<br />
Stop input X X Contact<br />
Stop input 5V GND Supply 5V DC<br />
Dosing monitoring X X Contact<br />
Dosing monitoring GND 5V Supply 5V DC<br />
Dosing output<br />
(pump running)<br />
Open collector * NPN<br />
* Open collector can be used for a relay or a lamp.<br />
Number/colour<br />
Function<br />
1/brown 2/white<br />
Plug<br />
3/blue, +5V 4/black, GND 5/grey<br />
Type<br />
Low level X* X* Contact<br />
Low level 5V GND Supply 5V DC<br />
Empty tank X* X* Contact<br />
Empty tank 5V GND Supply 5V DC<br />
* The function for the potential free contact set can be chosen from the display (NO=Normally Open and NC=Normally Closed).