GRUNDFOS DATA BOOKLET<br />

DME and DMS<br />

DIGITAL DOSING


2<br />

Contents<br />

General data<br />

Performance range, DME 3<br />

Performance range, DMS 3<br />

DME and DMS 4<br />

Digital Dosing 4<br />

Type key 5<br />

Codes 5<br />

Functions<br />

Overview of functions 6<br />

Performance range 7<br />

Functional description, DME 8<br />

Functional description, DMS 8<br />

Control panel 9<br />

Menu 11<br />

Operating modes 12<br />

Dosing monitoring 16<br />

Control panel lock 17<br />

Wiring diagram, DME and DMS-A (0-48 l/h) 18<br />

Wiring diagram, DME (60-940 l/h) 19<br />

Construction<br />

Sectional drawing, DME (0-48 l/h) 21<br />

Material specification 21<br />

Sectional drawing, DME (60-940 l/h) 22<br />

Material specification 22<br />

Sectional drawing, DMS 23<br />

Material specification 23<br />

Dimensions<br />

Front-fitted control panel (0-48 l/h) 24<br />

Side-fitted control panel (0-48 l/h) 24<br />

Front-fitted control panel, DME (60-940 l/h) 25<br />

Technical data<br />

DME (0-48 l/h) 26<br />

DME (60-940 l/h) 27<br />

DMS 28<br />

Pump selection<br />

Standard range, DME (0-48 l/h) 29<br />

Non-standard range, DME (0-48 l/h) 30<br />

Standard range, DME (60-940 l/h) 31<br />

Non-standard range, DME (60-940 l/h) 33<br />

Standard range, DMS 34<br />

Non-standard range, DMS 36<br />

Pumped liquids<br />

List of pumped liquids 37<br />

<strong>Accessories</strong><br />

38


General data<br />

Performance range, DME<br />

p<br />

[bar]<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

1 2.5 7.5 12 18.5 48 60 150 250 376 940<br />

Q [l/h]<br />

Performance range, DMS<br />

p<br />

[bar]<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

DME 2-18<br />

DMS 2-11<br />

DME 8-10<br />

DMS 4-7<br />

DME DME<br />

12-6 19-6<br />

DME 60-10 DME 375-10<br />

DMS 8-5<br />

DME 48-3<br />

DME<br />

DME 150-4 DME 940-4<br />

DMS 12-3<br />

DMS<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13<br />

Q [l/h]<br />

DME and DMS<br />

TM027811mance ranges, 50 an<br />

TM027810<br />

3


4<br />

General data<br />

DME and DMS<br />

Digital Dosing<br />

Digital Dosing represents state-of-the-art technology.<br />

This patented Grundfos solution sets new standards,<br />

including new principles and methods.<br />

Precise and easy setting<br />

The operator can easily install and set the pump to<br />

discharge exactly the quantity of dosing liquid required<br />

in the application. In the display, the setting of the pump<br />

is read out directly in ml/h or l/h, pulse or batch, and the<br />

operation mode is easily identified by means of icons.<br />

Unique technology<br />

A unique drive and microprocessor control ensure that<br />

dosing liquids are discharged precisely and with low<br />

pulsation even when the pump is operating with high<br />

viscosity or degassing liquids. Instead of the conventional<br />

stroke length adjustment, the capacity of the<br />

DME is regulated by automatic ajustment of the motor<br />

speed during the discharge stroke and by fixed suction<br />

stroke speed, ensuring optimal and uniform mixing. The<br />

capacity of the DMS is regulated by automatic regulation<br />

of the stroke frequency.<br />

GR7777r<br />

DME and DMS<br />

Fewer variants to cover all needs<br />

The powerful variable speed motor, a turn-down ratio of<br />

1:1000/1:800 and a complete control interface including<br />

• full pulse control,<br />

• pulse batch control,<br />

• internal timer batch control,<br />

• analog 0/4-20 mA control,<br />

• level control and<br />

• fieldbus communication module<br />

ensure that nine DME pumps cover the range from 0 to<br />

940 litres per hour up to 18 bar. The switch mode power<br />

supply ensures that the same pump is working<br />

precisely, irrespective of the mains supply (100-240 V;<br />

50-60 Hz).<br />

The DMS version with synchronous motor and a turndown<br />

ratio of 1:100 (consisting of four pump sizes and<br />

two control versions) cover the range from 0 to 12 l/h.<br />

The DMS-A pumps have external pulse, analog 4-20<br />

mA and level control interface; the DMS-B version is<br />

without external control interface. The DMS-D is<br />

without control and user interface.<br />

The DME and DMS dosing pumps feature diaphragm<br />

dosing head with integrated vent valve, suction and<br />

discharge ball valves.<br />

The pumps are fitted with power cable and plug.<br />

See page 5 and onwards for further information.


General data<br />

Type key Codes<br />

Example DME 2 - 18 A - PP / E / C - F - 1 1 1G F<br />

Type range<br />

Maximum capacity [l/h]<br />

Maximum pressure [bar]<br />

Code for control variant<br />

Code for dosing head material<br />

Code for gasket material<br />

Code for valve ball material<br />

Code for control panel position<br />

Code for supply voltage<br />

Code for valves<br />

Code for connection suction/discharge<br />

Code for mains plug<br />

DME and DMS<br />

Example<br />

Control variant<br />

A<br />

AR A + alarm relay<br />

AP A + Profibus<br />

AG A + GENIbus<br />

A - PP / E / C - F - 1 1 1 F<br />

B Basic<br />

D Only on/off<br />

Dosing head material<br />

PP Polypropylene<br />

PV PVDF<br />

SS Stainless steel<br />

Gasket material<br />

E EPDM<br />

T PTFE<br />

V FKM<br />

Valve ball material<br />

C Ceramic<br />

SS Stainless steel 1.4401<br />

G Glass<br />

T PTFE<br />

Y Hastelloy C-22<br />

Control panel position<br />

F Front-fitted<br />

S Side-fitted<br />

X No control panel<br />

Supply voltage<br />

1 1 x 230 V, 50 Hz<br />

2 1 x 120 V, 60 Hz<br />

3 1 x 100-240 V, 50-60 Hz<br />

6 1 x 110 V, 50 Hz<br />

8 1 x 100 V, 50/60 Hz<br />

9 1 x 200 V, 50/60 Hz<br />

Valves<br />

1 Standard valve<br />

2 Spring-loaded valve<br />

Connection suction/discharge<br />

Tubing 6/9 mm<br />

1 Tubing 4/6 mm<br />

supplied with the pump<br />

Tubing 6/9 mm<br />

2 Tubing 6/12 + 9/12 mm<br />

supplied with the pump<br />

3 Tubing 4/6 mm<br />

4 Tubing 6/9 mm<br />

5 Tubing 6/12 mm<br />

6 Tubing 9/12 mm<br />

T Tubing 0.17"/0.25"<br />

R Tubing 0.25"/0.375"<br />

S Tubing 0.375"/0.5"<br />

A Threaded Rp 1/4<br />

B Threaded Rp 3/8<br />

V Threaded NPT 1/4"<br />

Y Threaded NPT 3/8"<br />

E Cementing d.10 mm<br />

F Cementing d.12 mm<br />

Q Tubing 19/27 + 25/34<br />

W Tubing 32/41 + 38/48<br />

A1 Threaded Rp 3/4"<br />

A2 Threaded Rp 1 1/4"<br />

Mains plug<br />

F EU (Schuko)<br />

B USA, Canada (120 V)<br />

G UK<br />

I Australia<br />

E Switzerland<br />

J Japan<br />

5


6<br />

Functions<br />

Overview of functions<br />

DME DMS<br />

DME and DMS<br />

0-48 l/h 60-940 l/h AR 60-940 l/h B variant A variant B variant D<br />

TM01 8941 0900<br />

Capacity control, see page 7<br />

Internal stroke frequency<br />

control<br />

<br />

Internal stroke speed control<br />

Control panel, see page 9<br />

<br />

Capacity setting in litres,<br />

millilitres or US gallons<br />

<br />

Display with background light<br />

and soft-touch buttons<br />

<br />

Easy set-up menu with<br />

language options<br />

<br />

On/off button <br />

Maximum capacity button<br />

(priming)<br />

<br />

Green indicator light for<br />

operating indication<br />

<br />

Red indicator light for<br />

fault indication<br />

<br />

Control panel lock <br />

Side-fitted as an option<br />

Operating modes, see page 12<br />

<br />

Manual control <br />

Pulse control <br />

Analog 0/4-20 mA control <br />

Timer-based batch control <br />

Pulse-based batch control<br />

Functions, see page 15<br />

<br />

Dosing monitoring <br />

Dual-level control <br />

Calibration of pump to actual<br />

installation<br />

<br />

Anti-cavitation<br />

(reduced suction speed)<br />

<br />

Capacity limitation <br />

Counters for strokes, operating<br />

hours and power on/off<br />

<br />

Fieldbus communication <br />

Overload protection <br />

Error message in display <br />

Leakage sensor <br />

Dosing signal output<br />

Power supply, page 15<br />

<br />

Switch-mode power supply<br />

Inputs/outputs, see page 18<br />

<br />

Input for pulse control <br />

Input for analog 0/4-20 mA<br />

control<br />

<br />

Input for dual-level control <br />

Input for external start/stop <br />

Alarm relay output (variant AR) <br />

Dosing output <br />

Input for external on/off switch <br />

TM02 8337 4903<br />

TM02 8338 4903<br />

TM01 8941 0900<br />

TM01 8943 0900<br />

TM02 8973 1304


Functions<br />

Performance range<br />

p<br />

[bar]<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

DME 2-18<br />

DMS 2-11<br />

DME 8-10<br />

DMS<br />

4-7<br />

DMS<br />

8-5<br />

DME DME<br />

12-6 19-6<br />

DMS<br />

12-3<br />

DME 60-10 DME 375-10<br />

DME 48-3<br />

1 2.5 4 7.5 12 18.5 48 60 150 376 940<br />

Q [l/h]<br />

The maximum capacity is available at any counter-pressure<br />

if the pump has been calibrated to the actual installation.<br />

DMS, DME<br />

DME 150-4 DME 940-4<br />

DME and DMS<br />

TM02 7812 4103<br />

7


8<br />

Functions<br />

Functional description, DME<br />

The electronically controlled variable-speed motor of<br />

the DME pumps provides optimum control of the stroke<br />

speed. As shown in the figure below, the duration of<br />

each suction stroke is constant while the duration of<br />

each discharge stroke varies according to the capacity<br />

set, resulting in optimum discharge flow in any operating<br />

situation.<br />

The advantages are as follows:<br />

• The pump is always operating at full stroke length,<br />

irrespective of the capacity set, for optimum accuracy,<br />

priming and suction.<br />

• A capacity range of 1:1000 (0-48 l/h) for each pump<br />

size.<br />

Capacity<br />

setting<br />

100%<br />

50%<br />

10%<br />

Discharge<br />

Discharge<br />

Discharge<br />

Functional description, DMS<br />

The electronically controlled synchronous motor of the<br />

DMS pumps offers almost the same advantages as<br />

those of DME pumps. As shown in the figure below, the<br />

suction and discharge stroke speeds are constant while<br />

the stroke frequency varies according to the capacity<br />

set. The sinusoidal movement of the diaphragm offers<br />

the following advantages:<br />

• The pump is always operating at full stroke length,<br />

irrespective of the capacity set, for optimum accuracy,<br />

priming and suction.<br />

Capacity<br />

Discharge<br />

setting<br />

100%<br />

50%<br />

10%<br />

Suction<br />

Suction<br />

Suction<br />

Suction<br />

Discharge<br />

Suction<br />

Discharge<br />

Suction<br />

DME and DMS<br />

• A capacity range of 1:800 (60-940 l/h) for each<br />

pump size.<br />

• Even and constant dosing ensuring an optimum<br />

mixing ratio at the injection point.<br />

• Significant reduction of pressure surges, preventing<br />

mechanical stress on diaphragm, tubes, connections<br />

and other dosing parts exposed to leakage<br />

and wear.<br />

• The installation is less affected by long suction and<br />

discharge lines.<br />

• Easier dosing of highly viscous and gas-containing<br />

liquids.<br />

The optimum dosing control shown below takes place<br />

in any operating mode.<br />

duration<br />

duration<br />

duration<br />

• A capacity range of 1:100 for each pump size.<br />

• Reduction of pressure surges, preventing mechanical<br />

stress on diaphragm, tubes, connections and<br />

other dosing parts exposed to leakage and wear.<br />

• The installation is less affected by long suction and<br />

discharge lines.<br />

• Easier dosing of highly viscous and gas-containing<br />

liquids.<br />

duration<br />

duration<br />

duration<br />

TM01 8944 0900<br />

TM01 8945 0900


Functions<br />

Control panel<br />

LCD Display<br />

Menu/<br />

accept<br />

Navigation/<br />

settings<br />

Priming button<br />

Control panel fitted to the front.<br />

Control panel fitted to the side (not DMS-B).<br />

Priming button<br />

100%<br />

The pump control panel incorporates a 100% button.<br />

Press this button if the maximum capacity is required<br />

over a short period, e.g. during start-up. When the<br />

button is released, the pump automatically returns to<br />

the previous operating mode.<br />

When the buttons 100% and are pressed simultaneously,<br />

the pump can be set to run for a specific number<br />

of seconds at maximum capacity. The remaining<br />

numbers of seconds will appear in the display. This<br />

feature is useful when flushing the pump. The<br />

maximum value is 300 seconds.<br />

Press to stop the pump before the set time has<br />

passed.<br />

ml/h<br />

Navigation/<br />

settings<br />

Green<br />

indicator light<br />

Red<br />

indicator light<br />

On/off button<br />

TM01 8946 1202<br />

TM01 8941 0900<br />

TM01 8949 0900<br />

DME and DMS<br />

Indicator lights and alarm output (0-48 l/h)<br />

The green and red indicator lights on the pump indicate<br />

operation or fault.<br />

In control variant AR, the pump can activate an external<br />

alarm signal by means of a built-in alarm relay. The<br />

alarm signal is activated by means of an internal potential-free<br />

contact.<br />

The functions of the indicator lights and the built-in<br />

alarm relay appear from the table below.<br />

Condition<br />

Green<br />

LED<br />

Pump running On Off<br />

Set to stop Flashing Off<br />

Red LED Display<br />

Normal<br />

indication<br />

Normal<br />

indication<br />

Pump fault Off On EEPROM<br />

Supply failure Off Off Off<br />

Pump running, low<br />

chemical level 1 On On<br />

Empty tank 2 Off On<br />

Analog signal<br />

< 2 mA<br />

The pump is not dosing<br />

enough according to the<br />

signal from the dosing<br />

monitor 3<br />

Off On<br />

On On<br />

More pulses than capacity On On<br />

Overheated Off On<br />

Normal<br />

indication<br />

Normal<br />

indication<br />

Normal<br />

indication<br />

Normal<br />

indication<br />

Normal<br />

indication<br />

MAX<br />

TEMP<br />

1 Control variant AR, only.<br />

2 Requires connection to level sensors.<br />

3 Requires dosing monitor function activated and a dosing<br />

monitor device connected to the pump.<br />

Alarm<br />

output 1<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

9


10<br />

Functions<br />

Indicator lights and alarm output (60-940 l/h)<br />

Condition<br />

Green<br />

LED<br />

Red<br />

LED<br />

Pump running On Off<br />

Set to stop Flashing Off<br />

Display<br />

Normal<br />

indication<br />

Normal<br />

indication<br />

Pump fault Off On EEPROM<br />

Supply failure Off Off Off<br />

Pump running, low<br />

chemical level<br />

On On LOW<br />

Empty tank 2 Off On EMPTY<br />

Analog signal < 2 mA Off On NO mA<br />

The dosed quantity is too<br />

small according to the<br />

signal from the dosing<br />

monitor 3<br />

On Off<br />

Overheating Off On<br />

Internal communication<br />

failure<br />

Off On<br />

NO<br />

FLOW<br />

MAX<br />

TEMP<br />

INT<br />

COM<br />

Internal Hall Failure 4 Off On HALL<br />

Diaphragm failure<br />

(leakage) 5 Off On LEAKAGE<br />

Max. pressure<br />

exceeded 5 Off 6 On<br />

More pulses than<br />

capacity<br />

On On<br />

OVER-<br />

LOAD<br />

MAX<br />

FLOW<br />

No detection of<br />

motor rotation 4 On On ORIGO<br />

Alarm<br />

output1<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 2 3<br />

NC NO C<br />

1 Control variant AR, only.<br />

2 Requires connection to level sensors.<br />

3 Requires activation of the dosing monitoring function and<br />

connection to a dosing monitor.<br />

4 Please contact a Grundfos service centre.<br />

5 Alarms can be reset after fault conditions are back to normal.<br />

6 The pump will make 10 attempts to restart before going into<br />

permanent off mode.<br />

DME and DMS


Functions<br />

Menu<br />

The DME and DMS dosing pumps feature a userfriendly<br />

menu which is activated by pressing the<br />

button. During start-up, all texts will appear in the<br />

English language, but other languages can be chosen,<br />

see page 14.<br />

The example shown below applies to DME pumps.<br />

<br />

<br />

<br />

Applies only to DME, 60-940 l/h pumps.<br />

mA<br />

DME and DMS<br />

D68se<br />

11


12<br />

Functions<br />

Operating modes<br />

Manual control<br />

The pump is dosing constantly according to the quantity<br />

set in l/h or ml/h by means of the buttons and .<br />

It automatically changes over between the measuring<br />

units.<br />

Setting range, DME:<br />

DME 2: 2.5 ml/h - 2.5 (1.8) l/h<br />

DME 8: 7.5 ml/h - 7.5 (5.6) l/h<br />

DME 12: 12 ml/h - 12 (9) l/h<br />

DME 19: 18,5 ml/h - 18.5 (14.5) l/h<br />

DME 48: 48 ml/h - 48 (37) l/h<br />

DME 60: 75 ml/h - 60 l/h<br />

DME<br />

150:<br />

200 ml/h - 150 l/h<br />

DME<br />

375:<br />

500 ml/h - 376 l/h<br />

DME<br />

940:<br />

1200 ml/h - 940 l/h.<br />

The figures in brackets indicate the maximum<br />

capacity when the anti-cavitation function is activated.<br />

Setting range, DMS:<br />

DMS 2: 25 ml/h - 2.5 l/h<br />

DMS 4: 40 ml/h - 4 l/h<br />

DMS 8: 75 ml/h - 7.5 l/h<br />

DMS 12: 120 ml/h - 12 l/h.<br />

Pulse control<br />

Applies to DME and DMS-A<br />

The pump is dosing according to an external pulse<br />

signal, e.g. from a water meter.<br />

There is no direct relation between pulses and dosing<br />

strokes. The pump automatically calculates its optimal<br />

speed to ensure the required quantity is dosed for each<br />

pulse. The quantity to be dosed is set in ml/pulse. The<br />

pump adjusts its speed and/or stroke frequency<br />

according to two factors:<br />

• frequency of external pulses and<br />

• the set quantity per pulse.<br />

Setting range, DME:<br />

DME 2-18: 0.000023 ml/pulse - 5.0 ml/pulse<br />

DME 8-10: 0.000069 ml/pulse - 15.0 ml/pulse<br />

DME 12-6: 0.000111 ml/pulse - 24.0 ml/pulse<br />

DME 19-6: 0.000204 ml/pulse - 37.0 ml/pulse<br />

DME 48-3: 0.000530 ml/pulse - 96.0 ml/pulse<br />

DME 60-10: 0.000625 ml/pulse - 120 ml/pulse<br />

DME 150-4: 0.00156 ml/pulse - 300 ml/pulse<br />

DME 375-10:0.00392 ml/pulse - 750 ml/pulse<br />

DME 940-4: 0.00980 ml/pulse - 1880 ml/pulse.<br />

DME and DMS<br />

Setting range, DMS:<br />

DMS 2: 0.00232 ml/pulse - 50 ml/pulse<br />

DMS 4: 0.00370 ml/pulse - 80 ml/pulse<br />

DMS 8: 0.00695 ml/pulse - 150 ml/pulse<br />

DMS 12: 0.01110 ml/pulse - 240 ml/pulse<br />

Analog 4-20 mA control<br />

Applies to DME and DMS-A<br />

The pump is dosing according to an external analog<br />

signal. The dosed capacity is proportional to the input<br />

value in mA.<br />

4-20 (default): 4 mA = 0%<br />

20 mA = 100%<br />

20-4: 4 mA = 100%<br />

20 mA = 0%<br />

0-20: 0 mA = 0%<br />

20 mA = 100%<br />

20-0: 0 mA = 100%<br />

20 mA = 0%.<br />

The maximum capacity limitation, see page 13, will<br />

influence the capacity. 100% (20 mA) corresponds to<br />

the maximum capacity or the set capacity limitation.<br />

Maximum capacity [%]<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0 4 8 12 16 20<br />

Input signal [mA]<br />

Timer-based batch control<br />

4-20 mA signal<br />

signal<br />

Applies to DME<br />

The pump is dosing the set quantity in batches at<br />

maximum capacity or the set capacity limitation.<br />

The time until the first dosing (NX) and the following<br />

sequences (IN) can be set in minutes, hours and days.<br />

The maximum time limit is 9 days, 23 hours and 59<br />

minutes (9:23:59) The lowest acceptable value is one<br />

minute. IN must be higher than the time required to<br />

perform one batch. If IN is lower than the time required,<br />

the next batch will be ignored.<br />

In case of supply failure, the set dosing quantity, the IN<br />

time and the remaining NX time are stored. When the<br />

supply is reconnected, the pump will start up with the<br />

NX time at the time of the supply failure. This way the<br />

timer cycle will continue, but it will be delayed according<br />

TM01 8218 0100


Functions<br />

to the time of the supply failure.<br />

NX<br />

Setting range:<br />

DME 2: 0.23 ml/batch - 5 l/batch<br />

DME 8: 0.69 ml/batch - 15 l/batch<br />

DME 12: 1.11 ml/batch - 24 l/batch<br />

DME 19: 2.04 ml/batch - 37 l/batch<br />

DME 48: 5.3 ml/batch - 96 l/batch<br />

DME 60: 6.25 ml/batch - 120 l/batch<br />

DME 150: 15.6 ml/batch - 300 l/batch<br />

DME 375: 39.1 ml/batch - 750 l/batch<br />

DME 940: 97.9 ml/batch - 1880 l/batch.<br />

Pulse-based batch control<br />

Applies to DME<br />

The pump is dosing the set quantity in batches at<br />

maximum capacity or the set capacity limitation. The<br />

quantity is dosed every time the pump receives an<br />

external pulse. If the pump receives new pulses before<br />

the batch is completed, these pulses will be ignored.<br />

Setting range:<br />

DME 2: 0.23 ml/batch - 5 l/batch<br />

DME 8: 0.69 ml/batch - 15 l/batch<br />

DME 12: 1.11 ml/batch - 24 l/batch<br />

DME 19: 2.04 ml/batch - 37 l/batch<br />

DME 48: 5.3 ml/batch - 96 l/batch<br />

DME 60: 6.25 ml/batch - 120 l/batch<br />

DME 150: 15.6 ml/batch - 300 l/batch<br />

DME 375: 39.1 ml/batch - 750 l/batch<br />

DME 940: 97.9 ml/batch - 1880 l/batch.<br />

Pulse<br />

Quantity pr. batch<br />

IN<br />

Quantity pr. batch<br />

Pulse<br />

t<br />

t<br />

TM01 8942 0900<br />

TM01 8947 0900<br />

DME and DMS<br />

Anti-cavitation (0-48 l/h)<br />

Applies to DME<br />

When this function is selected, the pump extends and<br />

smooths its suction stroke, resulting in softer priming.<br />

The anti-cavitation function is used:<br />

• when pumping liquids of high viscosity<br />

• when pumping degassing liquids<br />

• in the case of a long suction tube and<br />

• in the case of a high suction lift.<br />

The maximum capacity is reduced when this function is<br />

selected, see below.<br />

DME 2: 1.8 l/h<br />

DME 8: 5.6 l/h<br />

DME 12: 9 l/h<br />

DME 19: 14.5 l/h<br />

DME 48: 37 l/h.<br />

Anti-cavitation (60-940 l/h)<br />

The pump features an anti-cavitation function. When<br />

this function is selected, the pump extends and<br />

smoothes its suction stroke, resulting in softer priming.<br />

The anti-cavitation function is used:<br />

• when pumping liquids of high viscosity,<br />

• in the case of a long suction tube and<br />

• in the case of a high suction lift.<br />

Depending on the circumstances, during the suction<br />

stroke, the motor speed can be reduced by 75%, 50% or<br />

25% compared to the normal motor speed during the<br />

suction stroke.<br />

The maximum pump capacity is reduced when the anticavitation<br />

function is selected.<br />

Maximum capacity limitation<br />

Applies to DME<br />

This function offers the possibility of reducing the<br />

maximum capacity (MAX. CAP). It influences the functions<br />

in which the pump is normally operating at<br />

maximum capacity. Under normal operating conditions,<br />

the pump cannot operate at a capacity higher than the<br />

one stated in the display. This does not apply to the<br />

priming button.<br />

By means of this function, a large pump can be set to<br />

act as a much smaller pump. Together with the 1:1000/<br />

1:800 capacity range, the purposes of this function are:<br />

13


14<br />

Functions<br />

1. To utilize the smooth and even dosing characteristics<br />

of the pump at low capacities, to achieve<br />

– improved chemical mixing,<br />

– improved dosing through long discharge tubes and<br />

– improved dosing of high-viscous liquids.<br />

2. To improve the dosing of gas-containing liquids: In a<br />

large pump, as compared to a small pump, the displaced<br />

volume (1) is much larger than the non-displaced<br />

volume (2).<br />

2<br />

Small pump Large pump<br />

3. To cover several needs with just one pump size.<br />

4. To adapt the pump to a 4-20 mA signal control with<br />

4 mA corresponding to 0% and 20 mA to the set<br />

maximum capacity.<br />

In this way it is possible for instance to use a DME 48<br />

for dosing a very small quantity of liquid without<br />

changing the input signal. See example below.<br />

Example:<br />

A DME 48 receives a 12 mA input signal from a control<br />

instrument, resulting in a 50% output (according to the<br />

analog curve on page 12) and a capacity of 24 l/h. A<br />

new situation occurs where it is only necessary to dose<br />

2 l/h. The maximum capacity limitation is set to 4 l/h.<br />

The pump is still receiving a 12 mA signal resulting in a<br />

50% output and a capacity of 2 l/h.<br />

Q [l/h]<br />

48<br />

44<br />

40<br />

36<br />

32<br />

28<br />

24<br />

20<br />

16<br />

12<br />

8<br />

4<br />

0<br />

2<br />

1<br />

No cap. limitation<br />

The maximum capacity limitation will also reduce the<br />

pump speed in timer-based batch control, pulse-based<br />

batch control and during calibration where the pump is<br />

usually operating at maximum capacity.<br />

Calibration<br />

After start-up, the dosing pumps can be calibrated for<br />

the actual installation to ensure that the displayed value<br />

(millilitres or litres) is correct. A calibration program in<br />

the set-up menu facilitates calibration.<br />

1<br />

No cap. limitation<br />

Cap. limit. = 4 l/h<br />

0 4 8 12 16 20<br />

[mA]<br />

Cap. limit. = 4 l/h<br />

TM02 0158 3301<br />

TM01 9638 2700<br />

Counters<br />

DME and DMS<br />

The pump can display "non-resettable" counters for:<br />

• "Quantity"<br />

Accumulated dosed quantity in litres or US gallons.<br />

• "Strokes"<br />

Accumulated number of dosing strokes.<br />

• "Hours"<br />

Accumulated number of operating hours (power on).<br />

• "Power ON"<br />

Accumulated number of times the mains supply has<br />

been switched on.<br />

Languages<br />

The display text can be displayed in one of the following<br />

languages chosen in the set-up menu:<br />

• English<br />

• German<br />

• French<br />

• Italian<br />

• Spanish<br />

• Portuguese<br />

• Dutch<br />

• Swedish<br />

• Suomi<br />

• Danish<br />

• Czech<br />

• Slovak<br />

• Polish<br />

• Russian.<br />

Integrated venting valve<br />

The DME and DMS dosing pumps are provided with an<br />

integrated vent valve. The valve makes it very easy to<br />

prime the pump during start-up:<br />

The vent valve must be connected to the tank by means<br />

of a 4/6 mm PVC tubing.<br />

Vent valve<br />

TM01 8420 5099


Functions<br />

The vent valve must be connected to the tank by means<br />

of a 15/20 mm PVC tubing.<br />

DME 60-940 l/h<br />

Switch-mode power supply<br />

Applies to DME<br />

The DME pump is incorporates a switch-mode power<br />

supply. This makes the pump independent of variations<br />

in supply voltage and frequency. Operating range: 1 x<br />

100-240 V, 50-60 Hz.<br />

Level control<br />

Applies to DME and DMS-A<br />

The pump can be connected to a level control unit for<br />

monitoring of the chemical level in the tank.<br />

The pump can react to two level signals. The following<br />

table shows the pump reactions to the sensor signals:<br />

Level sensors Pump reaction<br />

Upper sensor activated<br />

Vent valve<br />

• Red indicator light is on.<br />

• Pump running.<br />

• Alarm relay activated.<br />

• Red indicator light is on.<br />

Lower sensor activated • Pump stopped.<br />

• Alarm relay activated.<br />

Applies to control variant AR<br />

Bus communication<br />

Applies to DME<br />

The pump is available with a built-in module for bus<br />

communication with GENIbus (variant AG, up to 48 l/h<br />

only) or PROFIBUS DP (variant AP) systems. These<br />

modules enable remote monitoring and setting via the<br />

fieldbus system.<br />

All DME features are available via bus communication.<br />

The PROFIBUS GDS-file can be downloaded from<br />

www.grundfos.com/dosing.<br />

Diaphragm leakage sensor (60-940 l/h)<br />

The pump can be fitted with a diaphragm leakage<br />

sensor. The sensor will detect leakage of the<br />

diaphragm. The sensor should be connected to the<br />

drain hole of the pump head. In case of leakage of the<br />

diaphragm, the signal from the sensor generates an<br />

alarm in the pump and the alarm relay will be activated.<br />

See page 41.<br />

TM02 7066 2503<br />

DME and DMS<br />

15


16<br />

Functions<br />

Dosing monitoring<br />

Applies to all DME and DMS-A(R) (0-48 l/h)<br />

Dosing stoke measured<br />

Monitor mounted on suction side<br />

(DME and DMS)<br />

The dosing monitor is designed to monitor the dosing of<br />

liquids which may cause gas accumulation in the<br />

dosing head, thus stopping the dosing process even if<br />

the pump is still operating.<br />

For every measured dosing stroke, the dosing monitor<br />

gives a pulse signal to the level input so that the pump<br />

can compare performed pump strokes (from internal<br />

stroke sensor) with externally measured physical<br />

strokes (from the dosing monitor). If an external dosing<br />

stroke is not measured together with the internal dosing<br />

stroke, this is considered a fault that may have been<br />

provoked by empty tank or gas in the dosing head.<br />

When used together with a DME pump, the monitor will<br />

only operate if it is mounted on the suction side of the<br />

pump.<br />

When used together with a DMS pump, the monitor will<br />

also operate if it is mounted on the discharge side of the<br />

pump.<br />

The dosing monitor should be connected to the level<br />

input (pins 2 and 3). This input must be configured to<br />

dosing monitoring. Consequently, it cannot be used as<br />

level input.<br />

Once the input has been set for dosing monitoring and<br />

a dosing monitor has been connected and set, the<br />

dosing monitoring function will be active.<br />

Definitions:<br />

• Correct dosing stroke: A pulse from the dosing monitor<br />

corresponds to the internal stroke signal within<br />

acceptable time.<br />

• Incorrect dosing stroke: There is no pulse from the<br />

dosing monitor corresponding to the internal stroke<br />

signal within the acceptable time (the pump is not<br />

pumping).<br />

Dosing stoke measured<br />

Monitor mounted on discharge side<br />

(DMS only)<br />

Dosing stoke measured<br />

DME and DMS<br />

Monitor mounted in dosing tube.<br />

In discharge tube: DMS (in-line)<br />

In suction tube: DME and DMS (in-line)<br />

Logic:<br />

If two incorrect dosing strokes are performed, the pump<br />

will continue operating, but it will change over to alarm<br />

mode. The red indicator light will be on and the alarm<br />

output, if any, will be activated (variant AR).<br />

For each correct stroke the counter is reset and the<br />

alarm output, if any, is deactivated.<br />

Operation in connection with vent valve:<br />

It is possible to add a self-acting solution for liquids that<br />

cause gas accumulation by using an automatic vent<br />

valve. The solution is the dosing monitor with a pump<br />

and an alarm output (control variant AR). The alarm<br />

output thus activates the vent valve, which will automatically<br />

vent gas accumulated in the dosing head. When<br />

the dosing head has been vented, the pump will start<br />

pumping again, the alarm output will be deactivated<br />

and the vent valve will close.<br />

TM02 2029 3201 - TM02 2030 3201 - TM02 2031 3201<br />

TM02 2048 4802


Functions<br />

Control panel lock<br />

It is possible to lock the buttons on the control panel to<br />

prevent maloperation of the pump. The locking function<br />

can be set to "ON" or "OFF". The default setting is<br />

"OFF".<br />

A PIN code must be entered to change from "OFF" to<br />

"ON". When "ON" is selected for the first time, "_ _ _ _"<br />

will appear in the display. If a code has already been<br />

entered, it will appear when an attempt to change to<br />

"ON" is made. This code can either be re-entered or<br />

changed.<br />

Units<br />

It is possible to select metric units (litre/millilitre) and<br />

US units (gallons/millilitre).<br />

Metric measuring units:<br />

• In manual and analog modes, set the quantity to be<br />

dosed in litres per hour (l/h) or millilitres per hour<br />

(ml/h).<br />

The drawing above shows all possible settings.<br />

3 x<br />

DME and DMS<br />

• In pulse mode, set the quantity to be dosed in ml/<br />

pulse. The actual capacity is indicated in litres per<br />

hour (l/h) or millilitres per hour (ml/h).<br />

• For calibration, set the quantity to be dosed in ml<br />

per 100 strokes.<br />

• In timer and batch modes, set the quantity to be<br />

dosed in litres (l) or millilitres (ml).<br />

• Under the "QUANTITY" menu item in the<br />

"COUNTERS" menu, the dosed quantity is indicated<br />

in litres.<br />

US measuring units:<br />

• In manual and analog modes, set the quantity to be<br />

dosed in gallons per hour (gph).<br />

• In pulse mode, set the quantity to be dosed in ml/<br />

pulse. The actual capacity is shown in gallons per<br />

hour (gph).<br />

• For calibration, set the quantity to be dosed in ml<br />

per 100 strokes.<br />

• In timer and batch modes, set the quantity to be<br />

dosed in gallons.<br />

• Under the "QUANTITY" menu item in the<br />

"COUNTERS" menu, the dosed quantity is indicated<br />

in gallons (gal).<br />

Operating display Operating display<br />

17


18<br />

Functions<br />

Wiring diagram, DME and DMS-A (0-48 l/h)<br />

See pages 26 and 28 for input/output data.<br />

Control input<br />

Level input<br />

Control cable<br />

Product no.:<br />

2 m cable: 96440447<br />

5 m cable: 96440448<br />

External stop in<br />

all other modes<br />

or<br />

Analog mode<br />

5<br />

"NO" black<br />

"NC" blue<br />

"COM" brown<br />

5 4 3 1 2 4 1 3 2<br />

4<br />

External stop in<br />

all other modes<br />

or<br />

Pulse/batch<br />

contact<br />

The level switch contacts (normally open) must be closed at low level/empty tank. Low level<br />

3<br />

1<br />

4<br />

1<br />

Level cable<br />

Product no.:<br />

2 m cable: 96440450<br />

5 m cable: 96440451<br />

3<br />

2<br />

Empty tank<br />

DME and DMS<br />

Number/colour<br />

Function<br />

1/brown 2/white<br />

Plug<br />

3/blue, +5V 4/black, GND 5/grey<br />

Type<br />

Pulse X X Contact<br />

Pulse 5V GND Supply 5V DC<br />

Analog (-) mA input (+) mA input mA signal<br />

Batch X X Contact<br />

Batch<br />

External start/stop<br />

5V GND Supply 5V DC<br />

Only Pulse/batch mode X X Contact<br />

Only Pulse/batch mode 5V GND Supply 5V DC<br />

All other modes X X Contact<br />

All other modes 5V GND Supply 5V DC<br />

Number/colour<br />

Function<br />

1/brown 2/white<br />

Plug<br />

3/blue, +5V 4/black, GND 5/grey<br />

Type<br />

Low level X X Contact<br />

Low level 5V GND Supply 5V DC<br />

Empty tank X X (+) mA input Contact<br />

Empty tank 5V GND Supply 5V DC<br />

Dosing monitoring X X Contact<br />

Dosing monitoring 5V GND Supply 5V DC<br />

TM03 1007 0905


Functions<br />

Wiring diagram, DME (60-940 l/h)<br />

Analog/Pulse/Leakage cable<br />

Product no.:<br />

2 m cable: 96440447<br />

5 m cable: 96440448<br />

Cable 1: Analog, pulse and leakage input<br />

Cable 2: Output for alarm relay<br />

1<br />

3<br />

2<br />

3<br />

2<br />

5<br />

4<br />

1<br />

5<br />

4<br />

3<br />

1<br />

3<br />

2<br />

5<br />

4<br />

1<br />

2<br />

3 1<br />

Relay cable<br />

Product no.:<br />

2 m cable: 96534214<br />

5 m cable: 96534215<br />

2<br />

1<br />

3<br />

Stop dosing cable<br />

Product no.:<br />

2 m cable: 96527109<br />

5 m cable: 96527111<br />

5<br />

3<br />

2<br />

2<br />

4<br />

1<br />

4<br />

1<br />

3<br />

2<br />

Level cable<br />

Product no.:<br />

2 m cable: 96440450<br />

5 m cable: 96440451<br />

DME and DMS<br />

Number/colour<br />

Function<br />

1/brown 2/white<br />

Plug<br />

3/blue, +5V 4/black, GND 5/grey<br />

Type<br />

Pulse X X Contact<br />

Pulse 5V GND Supply 5V DC<br />

Analog (-) mA input (+) mA input mA signal<br />

Batch X X Contact<br />

Batch 5V GND Supply 5V DC<br />

Leakage X X Contact<br />

Leakage 5V GND Supply 5V DC<br />

Number/colour 1/brown 2/white 3/blue<br />

Function<br />

Alarm relay output Common Normally open Normally closed<br />

TM0 27069 2503<br />

19


20<br />

Functions<br />

Cable 3: Stop dosing input and dosing monitor or dosing output<br />

Useful when the load (e.g. a relay) has one side<br />

connected to a power supply which is not the same one<br />

as connected to the sensor.<br />

When the dosing output is activated, the output<br />

provides the Gnd to the load.<br />

Recommended supply: max. 24 VDC.<br />

Max. current: 100 mA.<br />

Cable 4: Level input<br />

DME and DMS<br />

Number/colour<br />

Function<br />

1/brown 2/white<br />

Plug<br />

3/blue, +5V 4/black, GND 5/grey<br />

Type<br />

Stop input X X Contact<br />

Stop input 5V GND Supply 5V DC<br />

Dosing monitoring X X Contact<br />

Dosing monitoring GND 5V Supply 5V DC<br />

Dosing output<br />

(pump running)<br />

Open collector * NPN<br />

* Open collector can be used for a relay or a lamp.<br />

Number/colour<br />

Function<br />

1/brown 2/white<br />

Plug<br />

3/blue, +5V 4/black, GND 5/grey<br />

Type<br />

Low level X* X* Contact<br />

Low level 5V GND Supply 5V DC<br />

Empty tank X* X* Contact<br />

Empty tank 5V GND Supply 5V DC<br />

* The function for the potential free contact set can be chosen from the display (NO=Normally Open and NC=Normally Closed).


Construction<br />

Sectional drawing, DME (0-48 l/h)<br />

Construction<br />

3<br />

15<br />

14<br />

13<br />

2<br />

18<br />

The DME pump is a motor-driven diaphragm dosing<br />

pump consisting of the following main parts:<br />

Dosing head: Designed with a minimum of clearance<br />

space to optimise the priming and deaerating capabilities.<br />

The dosing head has built-in valve housings.<br />

Valves: Double-ball suction valve and single-ball<br />

discharge valve. Spring-loaded valves are available as<br />

an option.<br />

Vent valve: For priming and deaeration complete with<br />

connection for a 4/6 mm tubing.<br />

Connections: Sturdy and easy-to-use connections for<br />

various sizes of tubing, pipe thread or pipe cementing.<br />

Diaphragm: PTFE-coated, textile-reinforced EPDM<br />

diaphragm designed for long life.<br />

Backplate: With separation chamber, safety diaphragm<br />

and drain hole.<br />

Drive unit: With diaphragm connecting rod, crank, beltdrive<br />

and stepper motor, all mounted on a sturdy frame.<br />

Cabinet: Containing drive unit, electronics, control<br />

panel and various electrical connections.<br />

The pump can be supplied with spring-loaded valves.<br />

Spring material: Hastelloy.<br />

The spring is not shown in the sectional drawing.<br />

4<br />

5<br />

6<br />

7<br />

8<br />

10 11 12<br />

9<br />

1 16<br />

26<br />

25<br />

23<br />

20 19 22 21<br />

24<br />

17<br />

Material specification<br />

DME<br />

Pos. Description Material options<br />

1 Backplate PPE/PS 20% glass fibre<br />

2 Diaphragm Textile-reinforced EPDM, PTFE-coated<br />

3 Valve complete -<br />

4 O-ring EPDM/FKM<br />

5 Valve casing PP/PVDF/Stainless steel 1.4401<br />

6 Valve ball Ceramic/Stainless steel 1.4401<br />

7 Valve seat disk EPDM/FKM<br />

8 Valve seat ring PP/PVDF/Stainless steel 1.4401<br />

9 Connection complete -<br />

10<br />

Cone/thread piece/<br />

cementing piece<br />

PP/PVDF/Stainless steel 1.4401/PVC<br />

11 Clamping ring PP/PVDF<br />

12 Union nut PP/PVDF/Stainless steel 1.4401<br />

13 Vent valve screw PP/PVDF<br />

14 Vent valve ball Ceramic/Stainless steel 1.4401<br />

15 Vent valve O-ring EPDM/FKM<br />

16 Cabinet PPE/PS 20% glass fibre<br />

17 Power/alarm cable Rubber<br />

18 Dosing head PP/PVDF/Stainless steel 1.4401<br />

19 Drive belt Rubber, polyamide-reinforced<br />

20 Connecting rod Steel<br />

21 Origo sensor -<br />

22 Crank shaft Steel<br />

23 Power PCB -<br />

24 Operation PCB -<br />

25 Stepper motor -<br />

26 Drive frame Aluminium<br />

TM01 9994 3600<br />

21


22<br />

Construction<br />

Sectional drawing, DME (60-940 l/h)<br />

28<br />

27<br />

26<br />

25<br />

24<br />

23<br />

Material specification<br />

21<br />

22<br />

20<br />

19<br />

18<br />

17<br />

16<br />

15<br />

29<br />

31<br />

30<br />

14<br />

13<br />

39<br />

10 11<br />

12<br />

9<br />

32 36 37<br />

1 2 3 4 38<br />

Pos. Description Material options<br />

1 Backplate PPE/PS 20% glass fibre<br />

2 Spring DIN 17223 TYPE C<br />

3 Cabinet PPE/PS 20% glass fibre<br />

4 Origo sensor<br />

5<br />

Operation PCB<br />

(printed circuit board)<br />

6 Power cable Rubber<br />

7 Gear<br />

8 BLDC motor<br />

9 Drain hole or leakage sensor<br />

10 Hose nozzle PP/PVDF<br />

11 Union nut PP/PVDF<br />

12 Connection complete<br />

13 O-ring EPDM/FKM<br />

14 O-ring EPDM/FKM<br />

15 Venting valve ball Ceramic<br />

16 Spring Hastelloy C<br />

17 Spring Hastelloy C<br />

18 Venting valve house PP/PVDF<br />

19 Venting valve tap PP/PVDF<br />

20 O-ring EPDM/FKM<br />

21 End cover Steel<br />

22 Venting valve complete<br />

23 O-ring EPDM/FKM<br />

24 Valve seat PP/PVDF/SS 1.4401<br />

25 Valve ball<br />

Ceramic/Glass/SS 1.4401/<br />

Hastelloy C/PTFE<br />

26 Valve casing PP/PVDF/SS 1.4401<br />

33<br />

8<br />

34<br />

35<br />

7<br />

5<br />

6<br />

DME<br />

27 Spring Hastelloy C<br />

28 O-ring EPDM/FKM<br />

29 Valve complete<br />

30 Steel plate Steel<br />

31 Dosing head PP/PVDF/SS 1.4401<br />

32 Safety membrane<br />

33 Power PCB (printed circuit board)<br />

34 Crank shaft Steel<br />

35 I/O PCB (printed circuit board)<br />

36 Connecting rod Steel<br />

37 Steel plate Steel<br />

38 Steel frame Steel<br />

Textile-reinforced EPDM,<br />

39 Diaphragm<br />

PTFE-coated<br />

The pump is available with spring-loaded valves.<br />

Spring material: Hastelloy.<br />

The spring is not shown in the sectional drawing.<br />

TM0 28599 0604


Construction DMS<br />

Sectional drawing, DMS<br />

Construction<br />

14<br />

13<br />

2<br />

The DMS pump is a motor-driven diaphragm dosing<br />

pump consisting of the following main parts:<br />

Dosing head: Designed with a minimum of clearance<br />

space to optimise the priming and deaerating capability.<br />

The dosing head has built-in valve housings.<br />

Valves: Double-ball suction valve and single-ball<br />

discharge valve. Spring-loaded valves are available as<br />

an option.<br />

Vent valve: For priming and deaeration complete with<br />

connection for a 4/6 mm tubing.<br />

Connections: Sturdy and easy-to-use connections for<br />

various sizes of tubing, pipe thread or pipe cementing.<br />

Diaphragm: PTFE-coated, textile-reinforced EPDM<br />

diaphragm designed for long life.<br />

Backplate: With separation chamber, safety diaphragm<br />

and drain hole.<br />

Drive unit: With diaphragm connecting rod, crank, beltdrive<br />

and synchronous motor, all mounted on a sturdy<br />

frame.<br />

Cabinet: Containing drive unit, electronics, control<br />

panel and various electrical connections (DMS-A).<br />

The pump is available with spring-loaded valves.<br />

Spring material: Hastelloy.<br />

The spring is not shown in the sectional drawing.<br />

3<br />

15<br />

18<br />

4<br />

5<br />

6<br />

7<br />

8<br />

10 11 12<br />

9<br />

1 16<br />

26 21<br />

25<br />

20 19 22<br />

23<br />

24<br />

17<br />

Material specification<br />

Pos. Description Material options<br />

1 Backplate PPE/PS 20% glass fibre<br />

2 Diaphragm Textile-reinforced EPDM, PTFE-coated<br />

3 Valve complete -<br />

4 O-ring EPDM/FKM<br />

5 Valve casing PP/PVDF/Stainless steel<br />

6 Valve ball Ceramic/Stainless steel 1.4401<br />

7 Valve seat disk EPDM/FKM<br />

8 Valve seat O-ring PP/PVDF/Stainless steel 1.4401<br />

9 Connection complete -<br />

10<br />

Cone/thread piece/<br />

cementing piece<br />

PP/PVDF/Stainless steel 1.4401/PVC<br />

11 Clamping ring PP/PVDF<br />

12 Union nut PP/PVDF/Stainless steel 1.4401<br />

13 Vent valve screw PP/PVDF<br />

14 Vent valve ball Ceramic/Stainless steel 1.4401<br />

15 Vent valve O-ring EPDM/FKM<br />

16 Cabinet PPE/PS 20% glass fibre<br />

17 Power/alarm cable Rubber<br />

18 Dosing head PP/PVDF/Stainless steel 1.4401<br />

19 Drive belt Rubber, polyamide-reinforced<br />

20 Connecting rod Steel<br />

21<br />

Dosing stoke auxiliary<br />

spring<br />

-<br />

22 Crank shaft Steel<br />

23 Power PCB -<br />

24 Operation PCB -<br />

25 Synchronous motor -<br />

26 Drive frame Aluminium<br />

TM01 9995 3600<br />

23


24<br />

Dimensions<br />

Front-fitted control panel (0-48 l/h)<br />

D<br />

160<br />

Side-fitted control panel (0-48 l/h)<br />

D<br />

Dimensions are i mm.<br />

Pump type<br />

160<br />

100%<br />

110 B<br />

98<br />

DME 2<br />

DMS 2<br />

ml/h<br />

130<br />

110<br />

98<br />

C<br />

DMS 4<br />

C<br />

50<br />

DME 8<br />

DMS 8<br />

50<br />

B<br />

100%<br />

DME 12<br />

DMS 12<br />

A<br />

A<br />

ml/h<br />

DME and DMS<br />

DME 19 DME 48<br />

A 137 192<br />

B 239 294<br />

C 36 15<br />

D 168 188<br />

TM01 8953 1202<br />

TM01 8954 1202


Dimensions<br />

Front-fitted control panel, DME (60-940 l/h)<br />

C<br />

D<br />

Dimensions are i mm.<br />

A<br />

B<br />

G<br />

E H<br />

F<br />

I<br />

DME and DMS<br />

DME 60 DME 150 DME 375 DME 940<br />

A 198 198 238 238<br />

B 176 176 218 218<br />

C 331 345 471 496<br />

D 284 284 364 364<br />

E 180 180 230 230<br />

F 444 444 540 539<br />

G 41 28 31 6<br />

H 74 74 95 95<br />

I 187 187 246 246<br />

TM02 7062 2503<br />

25


26<br />

Technical data<br />

DME (0-48 l/h)<br />

Pump DME 2 DME 8 DME 12 DME 19 DME 48<br />

Mechanical data<br />

Weight and size<br />

Electrical data<br />

Signal input<br />

Maximum capacity without anti-cavitation 1<br />

Maximum capacity with anti-cavitation 1<br />

DME<br />

[l/h] 2.5 7.5 12 18.5 48<br />

[gph] 0.66 1.98 3.71 4.88 12.68<br />

[l/h] 1.8 5.6 9 14.5 37<br />

[gph] 0.49 1.48 2.78 3.66 9.51<br />

Maximum pressure<br />

[bar]<br />

[psi]<br />

18<br />

261<br />

10<br />

145<br />

6<br />

87<br />

6.2<br />

90<br />

2.6<br />

38<br />

Maximum stroke frequency 2 [stroke/min] 180 180 180 151 151<br />

Maximum suction lift during operation [m] 6<br />

Maximum suction lift when priming with wet valves [m] 1.8 3 3 3 3<br />

Maximum viscosity with spring-loaded valves 3 [mPas] (= cP) 500 500 500 500 100<br />

Maximum viscosity without spring-loaded valves 3 [mPas] (= cP) 200 200 200 200 100<br />

Maximum liquid temperature [°C] 50<br />

Minimum liquid temperature [°C] 0<br />

Maximum ambient temperature [°C] 45<br />

Minimum ambient temperature [°C] 0<br />

Accuracy of repeatability ±1%<br />

Weight [kg] 2.3 2.3 2.3 3.4 3.4<br />

Diaphragm diameter [mm] 28 38 43.5 55 77<br />

Supply voltage [V] 1 x 100-240 V, 50-60 Hz<br />

Maximum current consumption [A]<br />

at 100 V<br />

at 230 V<br />

0.27<br />

0.16<br />

0.35<br />

0.26<br />

Maximum power consumption P1 [W] 16.2 22.1<br />

Enclosure class IP 65<br />

Insulation class F<br />

Voltage in level sensor input [VDC] 5<br />

Voltage in pulse input [VDC] 5<br />

Minimum pulse-repetition period [ms] 3.3<br />

Impedance in analog 0/4-20 mA input [Ω] 250<br />

Maximum loop resistance in pulse signal circuit [Ω] 350<br />

Maximum loop resistance in level signal circuit [Ω] 350<br />

Signal output<br />

Maximum load of alarm relay output, at ohmic load [A]<br />

Maximum voltage, alarm relay output [V]<br />

2<br />

250<br />

Sound pressure The sound pressure level of the pump is lower than 70 db(A).<br />

Approvals CE, VDE, cUL, UL, METI<br />

1 At any counter-pressure if the pump is calibrated to the actual installation.<br />

2 The maximum stroke frequency varies according to calibration.<br />

3 Maximum suction lift: 1 metre.


Technical data<br />

DME (60-940 l/h)<br />

Pump DME 60 DME 150 DME 375 DME 940<br />

Mechanical data<br />

Weight and size<br />

Maximum capacity [l/h] 60 150 376 940<br />

Maximum capacity with anti-cavitation 75% [l/h] [l/h] 45 112 282 705<br />

Maximum capacity with anti-cavitation 50% [l/h] [l/h] 33.4 83.5 210 525<br />

Maximum capacity with anti-cavitation 25% [l/h] [l/h] 16.1 40.4 101 252<br />

Maximum pressure [bar] 10 4 10 4<br />

Maximum stroke frequency [stroke/min] 160<br />

Maximum suction lift during operation [m] 6<br />

Maximum suction lift when priming with wet valves [m] 1.5<br />

Maximum viscosity with spring-loaded valves 1 [mPas] (= cP)<br />

3000 mPas at 50% capacity<br />

Maximum viscosity without spring-loaded valves 1 [mPas] (= cP)<br />

200<br />

Maximum liquid temperature [°C] 50<br />

Minimum liquid temperature [°C] 0<br />

Maximum ambient temperature [°C] 45<br />

Minimum ambient temperature [°C] -10<br />

Accuracy of repeatability ±1%<br />

Weight [kg] 11.4 11.8 21 22.5<br />

Diaphragm diameter [mm] 79 106 124 173<br />

Supply voltage [V] 1 x 100-240 V, 50-60 Hz<br />

Electrical data<br />

Maximum current consumption [A]<br />

Maximum power consumption P1 [W]<br />

at 100 V<br />

at 230 V<br />

1.25<br />

0.67<br />

67.1<br />

2.40<br />

1.0<br />

240<br />

Enclosure class IP 65<br />

Insulation class B<br />

Cable data Supply cable 1.5 metre<br />

Signal input<br />

Voltage in level sensor input [VDC] 5<br />

Voltage in pulse input [VDC] 5<br />

Minimum pulse-repetition period [ms] 3.3<br />

Impedance in analog 0/4-20 mA input [Ω] 250<br />

Maximum loop resistance in pulse signal circuit [Ω] 350<br />

Maximum loop resistance in level signal circuit [Ω] 350<br />

Signal output<br />

Maximum load of alarm relay output, at ohmic load [A]<br />

Maximum voltage, alarm relay output [V]<br />

2<br />

42<br />

Approvals CE, VDE, CSA<br />

Sound pressure<br />

level<br />

The sound pressure level of the pump is lower than 70 dB (A).<br />

1 Maximum suction lift: 1 metre.<br />

DME<br />

27


28<br />

Technical data<br />

DMS<br />

Pump DMS 2 DMS 4 DMS 8 DMS 12<br />

Mechanical data<br />

Weight and size<br />

Electrical data<br />

Signal input<br />

Maximum capacity 1<br />

Maximum pressure<br />

Maximum stroke frequency 2 [stroke/min]<br />

DMS-A and<br />

AR, B<br />

DMS-D (50 Hz)<br />

DMS-D (60 Hz)<br />

DMS<br />

[l/h] 2.5 4 7.5 12<br />

[gph] 0.66 1.05 1.98 3.71<br />

[l/h] 3.3 ± 20% 5.7 ±18% 8.7 ± 8% 13.7 ± 6%<br />

[gph]<br />

0.87 ±<br />

20%<br />

1.5 ±18% 2.3 ± 8% 3.6 ± 6%<br />

[l/h] 3.9 ± 20% 6.9 ±18% 10.4 ± 8% 16.4 ± 6%<br />

[gph]<br />

1.03 ±<br />

20%<br />

1.82 ±18% 2.75 ± 8% 4.33 ± 6%<br />

[bar] 11 7 5.4 3.4<br />

[psi] 160 102 78 49<br />

DMS-A and AR, B 180<br />

DMS-D (50 Hz)<br />

DMS-D (60 Hz)<br />

Maximum suction lift during operation [m] 6<br />

Maximum suction lift when priming with wet valves [m] 1.8 2 3 3<br />

Maximum viscosity with spring-loaded valves 3 [mPas] (= cP)<br />

500<br />

Maximum viscosity without spring-loaded valves 3 [mPas] (= cP)<br />

200<br />

Maximum liquid temperature [°C] 50<br />

Minimum liquid temperature [°C] 0<br />

Maximum ambient temperature [°C] 45<br />

Minimum ambient temperature [°C] 0<br />

Accuracy of repeatability ±1%<br />

Weight [kg] 2.3<br />

Diaphragm diameter [mm] 28 32 38 42.5<br />

Supply voltage<br />

187.5<br />

225<br />

1 x 230 V –13%/+10%, 50/60 Hz<br />

1 x 120 V –12%/+8%, 60 Hz<br />

1 x 100 V ±6%, 50/60 Hz<br />

at 100 V 0.2<br />

Maximum current consumption [A]<br />

at 120 V 0.17<br />

at 230 V 0.09<br />

Maximum power consumption P1 [W] 20<br />

Enclosure class IP 65<br />

Insulation class F<br />

Voltage in level sensor input [VDC] 5<br />

Voltage in pulse input [VDC] 5<br />

Minimum pulse-repetition period [ms] 3.3<br />

Impedance in 0/4-20 mA analog input [Ω] 250<br />

Maximum loop resistance in pulse signal circuit [Ω] 350<br />

Maximum loop resistance in level signal circuit [Ω] 350<br />

Signal output<br />

Maximum load of alarm relay output at ohmic load [A]<br />

Maximum voltage, alarm relay output [V]<br />

2<br />

250<br />

Sound pressure The sound pressure level of the pump is lower than 70 db(A).<br />

Approvals CE, VDE cUL, UL, METI 4<br />

1 Irrespective of counter-pressure if the pump is calibrated to the actual installation.<br />

2 The maximum stroke frequency varies according to calibration.<br />

3 Maximum suction lift: 1 metre.<br />

4 DMS-D: only CE and VDE.


Pump selection<br />

Standard range, DME (0-48 l/h)<br />

Power supply: 1 x 100-240 V, 50-60 Hz<br />

(Switch-mode).<br />

Mains plug: EU (Schuko).<br />

Valves: Double-ball on suction side, single-ball on discharge side.<br />

Max.<br />

capacity<br />

[l/h] 1<br />

2.5<br />

(1.8)<br />

7.5<br />

(5.6)<br />

12<br />

(9)<br />

18.5<br />

(14.5)<br />

48<br />

(37)<br />

Max.<br />

pressure<br />

[bar]<br />

18<br />

10<br />

6<br />

6.2<br />

2.6<br />

Materials 2<br />

Pump head Gaskets Valve balls<br />

Connection<br />

3<br />

PP EPDM Ceramic 4/6, 6/9<br />

PP FKM Ceramic 4/6, 6/9<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4<br />

PP EPDM Ceramic 4/6, 6/9<br />

PP FKM Ceramic 4/6, 6/9<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4<br />

PP EPDM Ceramic 4/6, 6/9<br />

PP FKM Ceramic 4/6, 6/9<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

Rp 1/4<br />

6/9,<br />

9/12<br />

6/9,<br />

9/12<br />

6/9,<br />

9/12<br />

Rp 3/8<br />

6/9,<br />

9/12<br />

6/9,<br />

9/12<br />

6/9,<br />

9/12<br />

Control panel<br />

position<br />

Type designation<br />

(variant A) 4<br />

DME and DMS<br />

Without<br />

alarm relay<br />

(variant A)<br />

Product<br />

number<br />

With alarm<br />

relay<br />

(variant AR)<br />

Front-fitted DME 2-18 A-PP/E/C-F-3111F 96434879 96434885<br />

Side-fitted DME 2-18 A-PP/E/C-S-3111F 96434882 96434888<br />

Front-fitted DME 2-18 A-PP/V/C-F-3111F 96443981 96443987<br />

Side-fitted DME 2-18 A-PP/V/C-S-3111F 96443984 96443990<br />

Front-fitted DME 2-18 A-PV/V/C-F-3111F 96434899 96434905<br />

Side-fitted DME 2-18 A-PV/V/C-S-3111F 96434902 96434908<br />

Front-fitted DME 2-18 A-SS/V/SS-F-31AAF 96437423 96437429<br />

Side-fitted DME 2-18 A-SS/V/SS-S-31AAF 96437426 96437432<br />

Front-fitted DME 8-10 A-PP/E/C-F-3111F 96434880 96434886<br />

Side-fitted DME 8-10 A-PP/E/C-S-3111F 96434883 96434889<br />

Front-fitted DME 8-10 A-PP/V/C-F-3111F 96443982 96443988<br />

Side-fitted DME 8-10 A-PP/V/C-S-3111F 96443985 96443991<br />

Front-fitted DME 8-10 A-PV/V/C-F-3111F 96434900 96434906<br />

Side-fitted DME 8-10 A-PV/V/C-S-3111F 96434903 96434909<br />

Front-fitted DME 8-10 A-SS/V/SS-F-31AAF 96437424 96437430<br />

Side-fitted DME 8-10 A-SS/V/SS-S-31AAF 96437427 96437433<br />

Front-fitted DME 12-6 A-PP/E/C-F-3111F 96434881 96434887<br />

Side-fitted DME 12-6 A-PP/E/C-S-3111F 96434884 96434890<br />

Front-fitted DME 12-6 A-PP/V/C-F-3111F 96443983 96443989<br />

Side-fitted DME 12-6 A-PP/V/C-S-3111F 96443986 96443992<br />

Front-fitted DME 12-6 A-PV/V/C-F-3111F 96434901 96434907<br />

Side-fitted DME 12-6 A-PV/V/C-S-3111F 96434904 96434910<br />

Front-fitted DME 12-6 A-SS/V/SS-F-31AAF 96437425 96437431<br />

Side-fitted DME 12-6 A-SS/V/SS-S-31AAF 96437428 96437434<br />

Front-fitted DME 19-6 A-PP/E/C-F-3122F 96434891 96434895<br />

Side-fitted DME 19-6 A-PP/E/C-S-3122F 96434893 96434897<br />

Front-fitted DME 19-6 A-PP/V/C-F-3122F 96443993 96443997<br />

Side-fitted DME 19-6 A-PP/V/C-S-3122F 96443995 96443999<br />

Front-fitted DME 19-6 A-PV/V/C-F-3122F 96434911 96434915<br />

Side-fitted DME 19-6 A-PV/V/C-S-3122F 96434913 96434917<br />

Front-fitted DME 19-6 A-SS/V/SS-F-31BBF 96437435 96437439<br />

Side-fitted DME 19-6 A-SS/V/SS-S-31BBF 96437437 96437441<br />

Front-fitted DME 48-3 A-PP/E/C-F-3122F 96434892 96434896<br />

Side-fitted DME 48-3 A-PP/E/C-S-3122F 96434894 96434898<br />

Front-fitted DME 48-3 A-PP/V/C-F-3122F 96443994 96443998<br />

Side-fitted DME 48-3 A-PP/V/C-S-3122F 96443996 96444000<br />

Front-fitted DME 48-3 A-PV/V/C-F-3122F 96434912 96434916<br />

Side-fitted DME 48-3 A-PV/V/C-S-3122F 96434914 96434918<br />

Stainl. steel<br />

Stainl. steel<br />

Front-fitted DME 48-3 A-SS/V/SS-F-31BBF 96437436 96437440<br />

FKM<br />

Rp 3/8<br />

1.4401<br />

1.4401<br />

Side-fitted DME 48-3 A-SS/V/SS-S-31BBF 96437438 96437442<br />

1 Values in brackets are maximum capacity if the anti-cavitation function has been selected.<br />

2 See list of pumped liquids on page 37.<br />

3 Underlined sizes are factory-fitted connections; others are supplied with the pump as standard.<br />

4/6, 6/9 and 9/12 are compression fittings for inner/outer tubing diameters stated in mm.<br />

Rp 1/4 and Rp 3/8 connections have inner thread for pipe connection.<br />

4 Also available in AR version.<br />

29


30<br />

Pump selection<br />

Non-standard range, DME (0-48 l/h)<br />

Example in bold: DME 2-18 A-SS/V/SS-F-32AAF<br />

Maximum<br />

capacity and<br />

pressure 2<br />

Control<br />

variant<br />

Materials of pump head,<br />

gaskets and valve balls<br />

[l/h] - [bar] See page 6 Dosing head:<br />

PP = Polypropylene<br />

PV = PVDF<br />

SS = Stainl. steel 1.4401<br />

Gaskets:<br />

E = EPDM<br />

V = FKMP<br />

T = PTFE<br />

DME Pump<br />

head<br />

2-18<br />

8-10<br />

12-6<br />

19-6<br />

48-3<br />

A<br />

AR<br />

AP 1<br />

AG 1<br />

A<br />

AR<br />

AP 1<br />

AG 1<br />

Valve balls:<br />

C = Ceramic<br />

SS = Stainl. steel 1.4401<br />

T = PTFE<br />

PP<br />

PV<br />

SS<br />

PP<br />

PV<br />

SS<br />

Gasket Ball<br />

E<br />

V<br />

T<br />

E<br />

T<br />

V<br />

E<br />

T<br />

V<br />

C<br />

SS<br />

T<br />

SS<br />

C<br />

SS<br />

T<br />

Control panel<br />

position<br />

F = Front-fitted<br />

S = Side-fitted<br />

1 Pumps equipped with bus communication module, see page 15.<br />

2<br />

2-18: 2.5 l/h, 18 bar<br />

8-10: 7.5 l/h, 10 bar<br />

12-6: 12 l/h, 6 bar<br />

19-6: 18.5 l/h, 6.2 bar<br />

48-3: 48 l/h, 2.6 bar<br />

E<br />

T<br />

V<br />

SS<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

Motor voltage Valves<br />

2 =<br />

1 = Standard<br />

1 x 120 V, 60 Hz 2 = Spring-loaded<br />

3 =<br />

1 x 100-240 V,<br />

50-60 Hz<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

Suction/discharge<br />

connection<br />

1 = Tubing 4/6+6/9<br />

2 = Tubing 6/9+6/12+9/12<br />

3 = Tubing 4/6<br />

4 = Tubing 6/9<br />

5 = Tubing 6/12<br />

6 = Tubing 9/12<br />

T = Tubing 0.17"/0.25"<br />

R = Tubing 0.25"/0.375"<br />

S = Tubing 0.375"/0.5"<br />

A = Threaded Rp 1/4<br />

B = Threaded Rp 3/8<br />

V = Threaded NPT 1/4"<br />

Y = Threaded NPT 3/8"<br />

E = Cementing d.10<br />

F = Cementing d.12<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A B<br />

V<br />

Y<br />

2<br />

4<br />

5<br />

6<br />

A<br />

E<br />

F<br />

A<br />

B<br />

V<br />

Y<br />

DME and DMS<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A B<br />

V<br />

Y<br />

2<br />

4<br />

5<br />

6<br />

A<br />

E<br />

F<br />

A<br />

B<br />

V<br />

Y<br />

Mains<br />

plug<br />

F = EU<br />

B =<br />

USA+CAN<br />

G = UK<br />

I = AU<br />

E = CH<br />

J = JP<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J


Pump selection<br />

Standard range, DME (60-940 l/h)<br />

Power supply: 1 x 100-240 V, 50-60 Hz<br />

(switch-mode).<br />

Mains plug: EU (Schuko).<br />

Valves: Single-ball on suction side;<br />

single-ball on discharge side.<br />

Max.<br />

capacity<br />

[l/h]<br />

Max.<br />

pressure<br />

[bar]<br />

Control<br />

variant<br />

60 10 AR<br />

60 10 B<br />

150 4 AR<br />

150 4 B<br />

376 10 AR<br />

376 10 B<br />

Materials<br />

Pump<br />

head Gaskets<br />

Valve<br />

balls<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

SS FKM<br />

St. steel<br />

1.4401<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

SS FKM<br />

St. steel<br />

1.4401<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

SS FKM<br />

St. steel<br />

1.4401<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

SS FKM<br />

St. steel<br />

1.4401<br />

PP EPDM Glass<br />

PP FKM Glass<br />

PVDF FKM Glass<br />

SS FKM<br />

St. steel<br />

1.4401<br />

PP EPDM Glass<br />

PP FKM Glass<br />

PVDF FKM Glass<br />

SS FKM<br />

St. steel<br />

1.4401<br />

E<br />

Connection<br />

<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

Rp 3/4”<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

Rp 3/4”<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

Rp 3/4”<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

19/27<br />

25/34<br />

Rp 3/4”<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

Rp 1 1/4”<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

Rp 1 1/4”<br />

Control<br />

panel<br />

position<br />

Type designation<br />

DME and DMS<br />

Product<br />

number<br />

Front-fitted DME 60-10 AR-PP/E/C-F-31QQF 96524874<br />

Side-fitted DME 60-10 AR-PP/E/C-S-31QQF 96524879<br />

Front-fitted DME 60-10 AR-PP/V/C-F-31QQF 96524910<br />

Side-fitted DME 60-10 AR-PP/V/C-S-31QQF 96524911<br />

Front-fitted DME 60-10 AR-PV/V/C-F-31QQF 96524912<br />

Side-fitted DME 60-10 AR-PV/V/C-S-31QQF 96524913<br />

Front-fitted DME 60-10 AR-SS/V/SS-F-31A1A1F 96524914<br />

Side-fitted DME 60-10 AR-SS/V/SS-S-31A1A1F 96524915<br />

Front-fitted DME 60-10 B-PP/E/C-F-31QQF 96524916<br />

Side-fitted DME 60-10 B-PP/E/C-S-31QQF 96524917<br />

Front-fitted DME 60-10 B-PP/V/C-F-31QQF 96524918<br />

Side-fitted DME 60-10 B-PP/V/C-S-31QQF 96524919<br />

Front-fitted DME 60-10 B-PV/V/C-F-31QQF 96524920<br />

Side-fitted DME 60-10 B-PV/V/C-S-31QQF 96524921<br />

Front-fitted DME 60-10 B-SS/V/SS-F-31A1A1F 96524923<br />

Side-fitted DME 60-10 B-SS/V/SS-S-31A1A1F 96524924<br />

Front-fitted DME 150-4 AR-PP/E/C-F-31QQF 96524925<br />

Side-fitted DME 150-4 AR-PP/E/C-S-31QQF 96524926<br />

Front-fitted DME150-4 AR-PP/V/C-F-31QQF 96524927<br />

Side-fitted DME 150-4 AR-PP/V/C-S-31QQF 96524928<br />

Front-fitted DME 150-4 AR-PV/V/C-F-31QQF 96524929<br />

Side-fitted DME 150-4 AR-PV/V/C-S-31QQF 96524930<br />

Front-fitted DME 150-4 AR-SS/V/SS-F-31A1A1F 96524931<br />

Side-fitted DME 150-4 AR-SS/V/SS-S-31A1A1F 96524932<br />

Front-fitted DME 150-4 B-PP/E/C-F-31QQF 96524933<br />

Side-fitted DME 150-4 B-PP/E/C-S-31QQF 96524934<br />

Front-fitted DME 150-4 B-PP/V/C-F-31QQF 96524935<br />

Side-fitted DME 150-4 B-PP/V/C-S-31QQF 96524936<br />

Front-fitted DME 150-4 B-PV/V/C-F-31QQF 96524937<br />

Side-fitted DME 150-4 B-PV/V/C-S-31QQF 96524938<br />

Front-fitted DME 150-4 B-SS/V/SS-F-31A1A1F 96524939<br />

Side-fitted DME 150-4 B-SS/V/SS-S-31A1A1F 96524940<br />

Front-fitted DME 375-10 AR-PP/E/G-F-31WWF 96524941<br />

Side-fitted DME 375-10 AR-PP/E/G-S-31WWF 96524942<br />

Front-fitted DME 375-10 AR-PP/V/G-F-31WWF 96524943<br />

Side-fitted DME 375-10 AR-PP/V/G-S-31WWF 96524944<br />

Front-fitted DME 375-10 AR-PV/V/G-F-31WWF 96524945<br />

Side-fitted DME 375-10 AR-PV/V/G-S-31WWF 96524946<br />

Front-fitted DME 375-10 AR-SS/V/SS-F-31A2A2F 96524947<br />

Side-fitted DME 375-10 AR-SS/V/SS-S-31A2A2F 96524948<br />

Front-fitted DME 375-10 B-PP/E/G-F-31WWF 96524949<br />

Side-fitted DME 375-10 B-PP/E/G-S-31WWF 96524950<br />

Front-fitted DME 375-10 B-PP/V/G-F-31WWF 96524951<br />

Side-fitted DME 375-10 B-PP/V/G-S-31WWF 96524952<br />

Front-fitted DME 375-10 B-PV/V/G-F-31WWF 96524953<br />

Side-fitted DME 375-10 B-PV/V/G-S-31WWF 96524954<br />

Front-fitted DME 375-10 B-SS/V/SS-F-31A2A2F 96524956<br />

Side-fitted DME 375-10 B-SS/V/SS-S-31A2A2F 96524957<br />

31


32<br />

Pump selection<br />

940 4 AR<br />

940 4 B<br />

PP EPDM Glass<br />

PP FKM Glass<br />

PVDF FKM Glass<br />

SS FKM<br />

St. steel<br />

1.4401<br />

PP EPDM Glass<br />

PP FKM Glass<br />

PVDF FKM Glass<br />

SS FKM<br />

St. steel<br />

1.4401<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

Rp 1 1/4”<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

32/41<br />

38/48<br />

Rp 1 1/4”<br />

19/27, 25/34, 32/41 and 38/48 are inner/outer tubing diameters in mm for hose clamp connectors.<br />

Rp 3/4” and Rp 1 1/4” connections have inner thread for pipe connection.<br />

DME and DMS<br />

Front-fitted DME 940-4 AR-PP/E/G-F-31WWF 96524958<br />

Side-fitted DME 940-4 AR-PP/E/G-S-31WWF 96524959<br />

Front-fitted DME940-4 AR-PP/V/G-F-31WWF 96524960<br />

Side-fitted DME 940-4 AR-PP/V/G-S-31WWF 96524961<br />

Front-fitted DME 940-4 AR-PV/V/G-F-31WWF 96524962<br />

Side-fitted DME 940-4 AR-PV/V/G-S-31WWF 96524963<br />

Front-fitted DME 940-4 AR-SS/V/SS-F-31A2A2F 96524964<br />

Side-fitted DME 940-4 AR-SS/V/SS-S-31A2A2F 96524965<br />

Front-fitted DME 940-4 B-PP/E/G-F-31WWF 96524966<br />

Side-fitted DME 940-4 B-PP/E/G-S-31WWF 96524967<br />

Front-fitted DME 940-4 B-PP/V/G-F-31WWF 96524968<br />

Side-fitted DME 940-4 B-PP/V/G-S-31WWF 96524969<br />

Front-fitted DME 940-4 B-PV/V/G-F-31WWF 96524980<br />

Side-fitted DME 940-4 B-PV/V/G-S-31WWF 96524981<br />

Front-fitted DME 940-4 B-SS/V/SS-F-31A2A2F 96524982<br />

Side-fitted DME 940-4 B-SS/V/SS-S-31A2A2F 96524983


Pump selection<br />

Non-standard range, DME (60-940 l/h)<br />

Example in bold: DME 150-4 AR SS/V/SS-F-32A1A1F<br />

Maximum<br />

capacity and<br />

pressure 2<br />

Control<br />

variant<br />

Materials of dosing<br />

head, gaskets<br />

and valve balls<br />

[l/h] - [bar] See page 5 Dosing head:<br />

PP = Polypropylene<br />

PV = PVDF<br />

SS = Stainl. stee 1.4401<br />

DME Pump<br />

head<br />

60-10<br />

150-4<br />

375-10<br />

940-4<br />

B<br />

AR<br />

AP 1<br />

B<br />

AR<br />

AP 1<br />

Gaskets:<br />

E = EPDM<br />

V = FKM<br />

T = PTFE<br />

Valve balls:<br />

C = Ceramic<br />

SS = Stainl. steel 1.4401<br />

Y = Hastelloy C<br />

G = Glass<br />

PP<br />

PV<br />

SS<br />

PP<br />

PV<br />

SS<br />

Gasket Ball<br />

E<br />

V<br />

T<br />

E<br />

T<br />

V<br />

E<br />

V<br />

T<br />

C<br />

SS<br />

Y<br />

SS<br />

G<br />

SS<br />

Y<br />

Control<br />

panel<br />

position<br />

F = Front-fitted<br />

S = Side-fitted<br />

1 Pumps equipped with bus communication module, see page 15.<br />

2<br />

60-10: 60l/h, 10 bar<br />

150-4: 150 l/h, 4bar<br />

375-10: 375 l/h, 10 bar<br />

940-4: 940 l/h, 4 bar<br />

E<br />

T<br />

V<br />

SS<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

Motor voltage Valves<br />

2 =1 x 120 V, 60 Hz<br />

3 = 1 x 100-240 V,<br />

50-60 Hz<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

Connection suction/<br />

discharge<br />

Q= 19/27 + 25/34<br />

1 = Standard W= 32/41 + 38/48<br />

2 = Springloaded A1= Threaded RP 3/4"<br />

A2= Threaded RP 1 1/4"<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

Q<br />

A1<br />

W<br />

A2<br />

DME and DMS<br />

Mains plug<br />

F = EU (DIN)<br />

B = USA+CAN<br />

G = UK<br />

I = AU<br />

E = CH<br />

J = JP<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

33


34<br />

Pump selection<br />

Standard range, DMS<br />

Power supply: 1 x 230 V, 50 Hz.<br />

Mains plug: EU (Schuko).<br />

Valves: Double-ball on suction side, single-ball on discharge side.<br />

Max.<br />

capacity [l/h]<br />

Max.<br />

pressure [bar]<br />

2.5<br />

11<br />

Control<br />

variant<br />

1<br />

A<br />

AR<br />

B<br />

3.3 D<br />

4<br />

7<br />

A<br />

AR<br />

B<br />

5.7 D<br />

Pump<br />

head<br />

Materials 2<br />

Gaskets<br />

Valve<br />

balls<br />

Connection<br />

3<br />

Control<br />

panel<br />

position<br />

Type designation<br />

(variants A 4 and B)<br />

DME and DMS<br />

Product<br />

number<br />

Without With<br />

alarm relay alarm relay<br />

(variant A) (variant AR)<br />

Variant<br />

D<br />

PP EPDM Ceramic 4/6, 6/9<br />

Front-fitted DMS 2-11 A-PP/E/C-F-1111F<br />

Side-fitted DMS 2-11 A-PP/E/C-S-1111F<br />

96437450<br />

96437451<br />

96446959<br />

96446960<br />

PP FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 2-11 A-PP/V/C-F-1111F<br />

Side-fitted DMS 2-11 A-PP/V/C-S-1111F<br />

96443969<br />

96443970<br />

96446961<br />

96446962<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 2-11 A-PV/V/C-F-1111F<br />

Side-fitted DMS 2-11 A-PV/V/C-S-1111F<br />

96437458<br />

96437459<br />

96446963<br />

96446964<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4<br />

Front-fitted DMS 2-11 A-SS/V/SS-F-11AAF<br />

Side-fitted DMS 2-11 A-SS/V/SS-S-11AAF<br />

96437466<br />

96437467<br />

96446965<br />

96446966<br />

PP EPDM Ceramic 4/6, 6/9 Front-fitted DMS 2-11 B-PP/E/C-F-1111F 96437474 -<br />

PP FKM Ceramic 4/6, 6/9 Front-fitted DMS 2-11 B-PP/V/C-F-1111F 96443977 -<br />

PVDF FKM Ceramic 4/6, 6/9 Front-fitted DMS 2-11 B-PV/V/C-F-1111F 96437478 -<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 Front-fitted DMS 2-11 B-SS/V/SS-F-11AAF 96437482 -<br />

PP EPDM Ceramic 4/6, 6/9 x DMS2-11 D-PP/E/C-X-1111F 96476529<br />

PP FKM Ceramic 4/6, 6/9 x DMS2-11 D-PP/V/C-X-1111F 96476532<br />

PVDF FKM Ceramic 4/6, 6/9 x DMS2-11 D-PV/V/C-X-1111F 96476533<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 x DMS2-11 D-SS/V/SS-X-11AAF 96476534<br />

PP EPDM Ceramic 4/6, 6/9<br />

Front-fitted DMS 4-7 A-PP/E/C-F-1111F<br />

Side-fitted DMS 4-7 A-PP/E/C-S-1111F<br />

96437452<br />

96437453<br />

96446967<br />

96446968<br />

PP FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 4-7 A-PP/V/C-F-1111F<br />

Side-fitted DMS 4-7 A-PP/V/C-S-1111F<br />

96443971<br />

96443972<br />

96446969<br />

96446970<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 4-7 A-PV/V/C-F-1111F<br />

Side-fitted DMS 4-7 A-PV/V/C-S-1111F<br />

96437460<br />

96437461<br />

96446971<br />

96446972<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4<br />

Front-fitted DMS 4-7 A-SS/V/SS-F-11AAF<br />

Side-fitted DMS 4-7 A-SS/V/SS-S-11AAF<br />

96437468<br />

96437469<br />

96446973<br />

96446974<br />

PP EPDM Ceramic 4/6, 6/9 Front-fitted DMS 4-7 B-PP/E/C-F-1111F 96437475 -<br />

PP FKM Ceramic 4/6, 6/9 Front-fitted DMS 4-7 B-PP/V/C-F-1111F 96443978 -<br />

PVDF FKM Ceramic 4/6, 6/9 Front-fitted DMS 4-7 B-PV/V/C-F-1111F 96437479 -<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 Front-fitted DMS 4-7 B-SS/V/SS-F-11AAF 96437483 -<br />

PP EPDM Ceramic 4/6, 6/9 x DMS4-7 D-PP/E/C-X-1111F 96476535<br />

PP FKM Ceramic 4/6, 6/9 x DMS4-7 D-PP/V/C-X-1111F 96476536<br />

PVDF FKM Ceramic 4/6, 6/9 x DMS4-7 D-PV/V/C-X-1111F 96476537<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 x DMS4-7 D-SS/V/SS-X-11AAF 96476538


Pump selection<br />

Max.<br />

capacity [l/h]<br />

Max.<br />

pressure [bar]<br />

Control<br />

variant<br />

1<br />

Pump<br />

head<br />

Materials 2<br />

Gaskets<br />

Valve<br />

balls<br />

Connection<br />

3<br />

Control<br />

panel<br />

position<br />

Type designation<br />

(variants A 4 and B)<br />

DME and DMS<br />

Product<br />

number<br />

Without With<br />

alarm relay alarm relay<br />

(variant A) (variant AR)<br />

PP EPDM Ceramic 4/6, 6/9<br />

Front-fitted DMS 8-5 A-PP/E/C-F-1111F<br />

Side-fitted DMS 8-5 A-PP/E/C-S-1111F<br />

96437454<br />

96437455<br />

96446975<br />

96446976<br />

A<br />

PP FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 8-5 A-PP/V/C-F-1111F<br />

Side-fitted DMS 8-5 A-PP/V/C-S-1111F<br />

96443973<br />

96443974<br />

96446977<br />

96446978<br />

AR<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 8-5 A-PV/V/C-F-1111F<br />

Side-fitted DMS 8-5 A-PV/V/C-S-1111F<br />

96437462<br />

96437463<br />

96446979<br />

96446980<br />

7.5<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4<br />

Front-fitted DMS 8-5 A-SS/V/SS-F-11AAF<br />

Side-fitted DMS 8-5 A-SS/V/SS-S-11AAF<br />

96437470<br />

96437471<br />

96446981<br />

96446982<br />

5.4<br />

PP EPDM Ceramic 4/6, 6/9 Front-fitted DMS 8-5 B-PP/E/C-F-1111F 96437476 -<br />

PP FKM Ceramic 4/6, 6/9 Front-fitted DMS 8-5 B-PP/V/C-F-1111F 96443979 -<br />

B PVDF FKM Ceramic 4/6, 6/9 Front-fitted DMS 8-5 B-PV/V/C-F-1111F 96437 80 -<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 Front-fitted DMS 8-5 B-SS/V/SS-F-11AAF 96437484 -<br />

PP EPDM Ceramic 4/6, 6/9 x DMS8-5 D-PP/E/C-X-1111F 96476540<br />

PP FKM Ceramic 4/6, 6/9 x DMS8-5 D-PP/V/C-X-1111F 96476541<br />

8.7 D PVDF FKM Ceramic 4/6, 6/9 x DMS8-5 D-PV/V/C-X-1111F 96476542<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 x DMS8- 5 D-SS/V/SS-X-11AAF 96476543<br />

PP EPDM Ceramic 4/6, 6/9<br />

Front-fitted DMS 12-3 A-PP/E/C-F-1111F<br />

Side-fitted DMS 12-3 A-PP/E/C-S-1111F<br />

96437456<br />

96437457<br />

96446951<br />

96446952<br />

A<br />

PP FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 12-3 A-PP/V/C-F-1111F<br />

Side-fitted DMS 12-3 A-PP/V/C-S-1111F<br />

96443975<br />

96443976<br />

96446953<br />

96446954<br />

AR<br />

PVDF FKM Ceramic 4/6, 6/9<br />

Front-fitted DMS 12-3 A-PV/V/C-F-1111F<br />

Side-fitted DMS 12-3 A-PV/V/C-S-1111F<br />

96437464<br />

96437465<br />

96446955<br />

96446956<br />

12<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4<br />

Front-fitted DMS 12-3 A-SS/V/SS-F-11AAF<br />

Side-fitted DMS 12-3 A-SS/V/SS-S-11AAF<br />

96437472<br />

96437473<br />

96446957<br />

96446958<br />

3.4<br />

PP EPDM Ceramic 4/6, 6/9 Front-fitted DMS 12-3 B-PP/E/C-F-1111F 96437477 -<br />

PP FKM Ceramic 4/6, 6/9 Front-fitted DMS 12-3 B-PP/V/C-F-1111F 96443980 -<br />

B PVDF FKM Ceramic 4/6, 6/9 Front-fitted DMS 12-3 B-PV/V/C-F-1111F 96437481 -<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 Front-fitted DMS 12-3 B-SS/V/SS-F-11AAF 96437485 -<br />

PP EPDM Ceramic 4/6, 6/9 x DMS 12-3 D-PP/E/C-X-1111F 96473184<br />

PP FKM Ceramic 4/6, 6/9 x DMS 12-3 D-PP/V/C-X-1111F 96476544<br />

13.7 D PVDF FKM Ceramic 4/6, 6/9 x DMS 12-3 D-PV/V/C-X-1111F 96476545<br />

Stainl. steel<br />

1.4401<br />

FKM<br />

Stainl. steel<br />

1.4401<br />

Rp 1/4 x DMS 12-3 D-SS/V/SS-X-11AAF 96476546<br />

1 See description of control variants on page 5.<br />

2 See list of pumped liquids on page 37.<br />

3 Underlined sizes are factory-fitted connections; others are supplied with the pump as standard.<br />

4/6 and 6/9 are compression fittings for inner/outer tubing diameters stated in mm.<br />

Rp 1/4 connection have inner thread for pipe connection.<br />

4 Also available in AR version.<br />

Variant<br />

D<br />

35


36<br />

Pump selection<br />

Non-standard range, DMS<br />

Example in bold: DMS 4-7 A-PP/V/C-S-1244F<br />

Max.<br />

capacity and<br />

pressure 2<br />

Control<br />

variant<br />

Materials of pump head,<br />

gaskets and valve balls<br />

[l/h] - [bar] See page 6 Dosing head:<br />

PP = Polypropylene<br />

PV = PVDF<br />

SS = Stainl. steel 1.4401<br />

DMS Pump<br />

head<br />

2-11<br />

4-7<br />

8-5<br />

12-3<br />

A-<br />

AR<br />

B<br />

D<br />

2 2-11: 2.5 l/h, 11 bar<br />

4-7: 4 l/h, 7 bar<br />

8-5: 7.5 l/h, 5.4 bar<br />

12-3: 12 l/h, 3.4 bar<br />

Gaskets:<br />

E = EPDM<br />

V = FKM<br />

T = PTFE<br />

Valve balls:<br />

C = Ceramic<br />

SS = Stainl. steel 1.4401<br />

T = PTFE<br />

PP<br />

PV<br />

SS<br />

PP<br />

PV<br />

SS<br />

PP<br />

PV<br />

SS<br />

Gasket Ball<br />

E<br />

V<br />

T<br />

V<br />

E<br />

E<br />

V<br />

T<br />

V<br />

E<br />

E<br />

V<br />

T<br />

V<br />

E<br />

C<br />

SS<br />

T<br />

SS<br />

C<br />

SS<br />

T<br />

Control panel<br />

position<br />

F = Front-fitted<br />

S = Side-fitted<br />

-F-<br />

-S-<br />

-F-<br />

-S-<br />

-F-<br />

SS -F-<br />

C<br />

SS<br />

T<br />

-X-<br />

SS -X-<br />

Motor<br />

voltage<br />

Valves<br />

1 =<br />

1 = Standard<br />

1 x 230 V, 50 Hz 2 = Spring-loaded<br />

2 =<br />

1 x 120 V, 60 Hz<br />

1 2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

1<br />

2<br />

Suction/discharge<br />

connection<br />

1 = Tubing 4/6+6/9<br />

2 = Tubing 6/9+6/12+9/12<br />

3 = Tubing 4/6<br />

4 = Tubing 6/9<br />

5 = Tubing 6/12<br />

6 = Tubing 9/12<br />

T = Tubing 0.17"/0.25"<br />

R = Tubing 0.25"/0.375"<br />

S = Tubing 0.375"/0.5"<br />

A = Threaded Rp 1/4<br />

B = Threaded Rp 3/8<br />

E = Cementing d.10<br />

F = Cementing d.12<br />

1<br />

2<br />

3<br />

4 5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A<br />

B<br />

V<br />

Y<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A<br />

B<br />

V<br />

Y<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A<br />

B<br />

V<br />

Y<br />

1<br />

2<br />

3<br />

4 5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A<br />

B<br />

V<br />

Y<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A<br />

B<br />

V<br />

Y<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

T<br />

R<br />

S<br />

A (PVC)<br />

E (PVC)<br />

F (PVC)<br />

A<br />

B<br />

V<br />

Y<br />

DME and DMS<br />

Mains<br />

plug<br />

F = EU<br />

B = USA+CAN<br />

G = UK<br />

I = AU<br />

E = CH<br />

J= JP<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

B<br />

G<br />

I<br />

E<br />

J<br />

F<br />

J<br />

F<br />

J


Pumped liquids<br />

List of pumped liquids<br />

The resistance table below is intended as a general<br />

guide for material resistance (at room temperature),<br />

and does not replace testing of the chemicals and pump<br />

materials under specific working conditions.<br />

Pumped liquid 20°C<br />

Concentration<br />

%<br />

PP<br />

DME and DMS<br />

The data shown are based upon information from<br />

various sources available, but many factors (purity,<br />

temperature, abrasive particles, etc.) may affect the<br />

chemical resistance of a given material.<br />

Note: Some of the liquids in this table may be toxic,<br />

corrosive or hazardous.<br />

Please be careful when handling these liquids.<br />

Pump housing<br />

Materials<br />

Gasket Ball<br />

PVDF<br />

25 – <br />

Acetic acid CH3COOH 60 – – <br />

85 – – – – <br />

Aluminium chloride AlCl3 40 – <br />

Aluminium sulphate Al2 (SO4 ) 3 60 <br />

Ammonia, aqueous NH4OH 28 – –<br />

Calcium hydroxide 7 Ca(OH) 2 –<br />

Calcium hypochlorite Ca(OCl) 2 20 – <br />

Chromic acid 5 10 <br />

H2CrO4 30<br />

40<br />

–<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

50 – – – <br />

Copper sulphate CuSO4 30 <br />

Ferric chloride3 FeCl3 100 – <br />

Ferric sulphate3 Fe2 (SO4 ) 3 100 <br />

Ferrous chloride FeCl2 100 – <br />

Ferrous sulphate FeSO4 50 <br />

Hydrochloric acid HCl<br />

< 25<br />

25-37<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Hydrogen peroxide H2O2 30 <br />

10 <br />

Nitric acid HNO3 30<br />

40<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

70 – – – – – <br />

Peracetic acid CH3COOOH 5 – – <br />

Potassium hydroxide KOH 50 – – –<br />

Potassium permanganate KMnO4 10 – <br />

Sodium chlorate NaClO3 30 <br />

Sodium chloride NaCl 30 – <br />

Sodium chlorite NaClO2 20 – – <br />

20 –<br />

Sodium hydroxide NaOH<br />

30 – –<br />

50 – –<br />

Sodium hypochlorite NaOCl 20 – <br />

Sodium sulphide Na2S 30 –<br />

Sodium sulphite 6 Na2SO3 20 –<br />

Sulphurous acid H2SO3 6 <br />

Sulphuric acid 4 H2SO4 < 80<br />

80-98<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

Suitable. 3 Risk of crystallisation.<br />

Stainl. steel<br />

1.4401<br />

Limited.<br />

4 Reacts violently with water and generates much heat.<br />

(Pump should be absolutely dry before dosing sulphuric acid.)<br />

– Not suitable. 5 Must be fluoride-free when glass balls are used.<br />

6 In neutral solutions.<br />

7 Saturated solution 0.1%.<br />

PVC<br />

FKM<br />

EPDM<br />

CSM<br />

PTFE<br />

Centellen C<br />

Ceramic<br />

Glass<br />

37


38<br />

<strong>Accessories</strong><br />

<strong>Accessories</strong><br />

Grundfos offers a comprehensive range of accessories<br />

covering every need when dosing with Grundfos dosing<br />

pumps.<br />

Overview<br />

Rigid suction line<br />

See page 53<br />

Foot valve<br />

See page 43<br />

Water meter<br />

see page 77<br />

Flow indicator<br />

See page 50<br />

Installation kit<br />

See page 39<br />

Counter-pressure or relief/<br />

isolating valve<br />

See page 57<br />

Automatic vent valve<br />

See page 62<br />

Multifunction valve<br />

See page 48<br />

Priming aid<br />

See page 67<br />

Tubing<br />

See page 42<br />

Rigid suction line<br />

with level sensors<br />

See page 53<br />

Level control unit<br />

See page 55<br />

Injection valve<br />

See page 45<br />

Pulsation dampener<br />

See page 64<br />

Pressure gauge<br />

See page 66<br />

Connector for pulsation dampener<br />

See page 65<br />

Pump connections<br />

See page 51<br />

Cable and plug<br />

See page 40<br />

Wall bracket<br />

See page 76<br />

Dosing monitor<br />

See page 49<br />

Tank<br />

See page 69<br />

Hand mixer<br />

See page 73<br />

Electric mixer<br />

See page 74<br />

Overview<br />

TM02 2099 3301


<strong>Accessories</strong><br />

Installation kit<br />

The installation kit includes:<br />

• foot non-return valve with strainer and weight<br />

• injection non-return valve, spring-loaded<br />

• 6 m PE discharge tubing<br />

• 2 m PVC suction tubing<br />

• 2 m PVC vent tubing.<br />

For pump types Size<br />

DME 2<br />

DME 8<br />

DME 12<br />

DMS 2<br />

DMS 4<br />

DMS 8<br />

DMS 12<br />

DME 19<br />

DME 48<br />

DN 4<br />

DN 8<br />

TM01 8956 0900<br />

Max. 2 metres<br />

Installation kit<br />

Max. 6 metres<br />

Max. 2 metres<br />

Valve materials Inner/outer tubing diameters Product<br />

number<br />

Housing Gasket Ball Suction Discharge Vent<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PVDF FKM Ceramic<br />

4/6 4/6 4/6 96457109<br />

6/9 6/9 4/6 96434858<br />

0.17"/1/4" 0.17"/1/4" 96480670<br />

1/4"/3/8" 1/4"/3/8" 96479881<br />

6/9 6/9 4/6 96446723<br />

4/6 4/6 4/6 96457110<br />

0.17"/1/4" 0.17"/1/4" 96480674<br />

1/4"/3/8" 1/4"/3/8" 96479898<br />

6/9 6/9 4/6 96434859<br />

4/6 4/6 4/6 96457111<br />

0.17"/1/4" 0.17"/1/4" 96480675<br />

1/4"/3/8" 1/4"/3/8" 96479899<br />

9/12 9/12 4/6 96440445<br />

3/8"/1/2" 3/8"/1/2" 96479947<br />

9/12 9/12 4/6 96446724<br />

3/8"/1/2" 3/8"/1/2" 96479949<br />

9/12 9/12 4/6 96440446<br />

3/8"/1/2" 3/8"/1/2" 96479948<br />

TM02 21083401<br />

39


40<br />

<strong>Accessories</strong><br />

Cable and plug<br />

Cable and plug for connection of pump to external<br />

control devices, such as process controllers, flow<br />

meters, start/stop contacts, and level sensors.<br />

Grundfos level control units are factory-fitted with cable<br />

and plug connection for Grundfos dosing pumps.<br />

The cables and plugs fit all dosing pumps, types DME<br />

and DMS-A.<br />

Cable material: PUR (0.34 mm 2 )<br />

Plug type: M12.<br />

Signal<br />

Number of<br />

poles<br />

Pulse, 0/4-20 mA, start/stop 5<br />

Dual-level 4<br />

Cable moulded with plug<br />

Type<br />

Cable length<br />

[m]<br />

Cable and plug<br />

TM01 8955 0900<br />

Product number<br />

2 96440447<br />

5 96440448<br />

2 96440450 1)<br />

5 96440451 1)<br />

Cable moulded with plug<br />

5 Stop dosing input and dosing output 1)<br />

3 Alarm relay cable with plug<br />

2<br />

5<br />

96527109<br />

96527111<br />

1)<br />

2<br />

5<br />

96534214<br />

96534215<br />

- 4 Extension cable 2 96483235<br />

Pulse, 0/4-20 mA, start/stop<br />

Dual-level<br />

1)<br />

Only DME 60-940 l/h<br />

5<br />

4<br />

Plug with terminals without cable<br />

-<br />

-<br />

96440449<br />

96440452


<strong>Accessories</strong><br />

Diaphragm leakage sensor (60 - 940 l/h)<br />

Optoelectronic leakage sensor to be inserted in the<br />

drain hole behind the diaphragm for sensing diaphragm<br />

breakage or leakage.<br />

The sensor unit consists of:<br />

• Transmitter receiver<br />

• Holder for fitting sensor in the drain hole of backplate<br />

• M12 plug and wire to transmit signal to pump.<br />

When the liquid gets into contact with the sensor, the<br />

light refraction changes, causing the sensor to emit a<br />

signal.<br />

The signal emitted from the sensor triggers the pump<br />

to stop dosing and give pump output alarm.<br />

Pump type Size Type Cable length [m] Product number<br />

DME (60-940 l/h) M12<br />

Leakage sensor<br />

M12<br />

GR 8211p<br />

0.5 m 96534443<br />

Diaphragm leakage sensor<br />

41


42<br />

<strong>Accessories</strong><br />

Tubing<br />

Tubing in various materials, sizes and lengths.<br />

TM01 8958 0900<br />

Tubing<br />

Inner/outer diameters [mm] Material Maximum pressure [bar] Length [m] Product number<br />

4/6<br />

6/9<br />

9/12<br />

PE<br />

PVC<br />

ETFE<br />

PE<br />

PVC<br />

ETFE<br />

PE<br />

PVC<br />

16 10 96441188<br />

16 50 96441190<br />

0.5 10 96441189<br />

0.5 50 96441191<br />

20 10 96441351<br />

20 50 96441352<br />

13 10 96441192<br />

13 50 96441195<br />

0.5 10 96441193<br />

0.5 50 96441194<br />

20 10 96441353<br />

20 50 96441354<br />

13 10 96441196<br />

13 50 96441198<br />

0.5 2 96535083<br />

0.5 10 96441197<br />

0,5 50 96441199<br />

ETFE<br />

20<br />

20<br />

10<br />

50<br />

96441355<br />

96441356<br />

12/19 PVC, textile-reinforced 15 10 96534489<br />

15/20 PVC 0,5 2 96535081<br />

16/24<br />

14 10 96441200<br />

19/27 10 5 96574383<br />

19/27 10 10 96574385<br />

25/34 PVC, textile-reinforced<br />

10 10 96441201<br />

25/34 10 5 96535070<br />

32/41 9 5 96535077<br />

32/41 9 10 96535079


<strong>Accessories</strong><br />

Foot valve<br />

Foot valve complete with non-return valve, strainer and<br />

tube or pipe connection.<br />

Dimensions<br />

Max. flow<br />

rate [l/h]<br />

15 DN 4<br />

72 DN 8<br />

TM01 9285 1600/GR8109<br />

DN 4, DN 8 DN 6, DN 10, DN 15, DN 20, DN 25<br />

Tubing/non-return valve Hose clamp Pipe cementing<br />

Non-return valve<br />

TM01 9276 1600/TM02 6433<br />

Materials Connection Dimensions<br />

Size Housing Gasket Ball Type<br />

PP EPDM Ceramic Tubing<br />

PP FKM Ceramic Tubing<br />

PV FKM Ceramic Tubing<br />

PP EPDM Ceramic Tubing<br />

PP FKM Ceramic Tubing<br />

PV FKM Ceramic Tubing<br />

Inner/outer<br />

tubing or pipe<br />

diameters<br />

TM01 2201 1600<br />

d ø<br />

[mm]<br />

L<br />

[mm]<br />

Product<br />

number<br />

4/6 - 36 72 96440526<br />

6/9 - 36 72 96440527<br />

0.17"/1/4" - 36 72 96480503<br />

1/4"/3/8" - 36 72 96479782<br />

4/6 - 36 72 96446860<br />

6/9 - 36 72 96446861<br />

0.17"/1/4" - 36 72 96480589<br />

1/4"/3/8" - 36 72 96479784<br />

4/6 - 36 72 96440529<br />

6/9 - 36 72 96440530<br />

0.17"/1/4" - 36 72 96480620<br />

1/4"/3/8" - 36 72 96479787<br />

6/9 - 36 72 96441841<br />

9/12 - 36 72 96440528<br />

1/4"/3/8" - 36 72 96480621<br />

3/8"/1/2" - 36 72 96479798<br />

6/9 - 36 72 96446865<br />

9/12 - 36 72 96446864<br />

1/4"/3/8" - 36 72 96480622<br />

3/8"/1/2" - 36 72 96480623<br />

6/9 - 36 72 96441842<br />

9/12 - 36 72 96440531<br />

1/4"/3/8" - 36 72 96480624<br />

3/8"/1/2" - 36 72 96479801<br />

Foot valve<br />

TM01 9277 1600<br />

Valve kit<br />

96499704<br />

96499705<br />

96499708<br />

96499706<br />

96499707<br />

96499709<br />

43


44<br />

<strong>Accessories</strong><br />

Max. flow<br />

rate [l/h]<br />

48 DN 6<br />

150 DN 10<br />

375 DN 15<br />

940<br />

DN 20<br />

DN 25<br />

PVC - Glass Pipe cementing -/12 12 32 37 96440535<br />

Stainl.<br />

steel<br />

CSM Stainl. steel<br />

Hose clamp 6/- 7 32 74 96446862<br />

Threaded<br />

-/Rp 1/4" Rp 1/4" 32 37 96446863<br />

-/NPT 1/4" NPT 1/4" 32 37 96479794<br />

PP EPDM<br />

22/26 39 115 96527112<br />

19/27<br />

PP<br />

Ceramics Hose clamp<br />

22/26 39 115 96527113<br />

FKM<br />

25/34<br />

PVDF 22/26 39 115 96527114<br />

PVC FKM Glass<br />

Stainl.<br />

steel<br />

FKM<br />

CSM<br />

Stainl. steel<br />

PVC FKM Glass<br />

Stainl.<br />

steel<br />

CSM Stainl. steel<br />

Hose clamp 9/- 10 50 86 96440532<br />

Pipe cementing -/16 16 50 56 96440536<br />

Threaded RP 3/4" RP 3/4" 39 115 96534450<br />

Hose clamp 9/- 10 50 86 96446727<br />

Threaded<br />

-/Rp 1/2" Rp 1/2" 50 56 96446855<br />

-/NPT 1/2" NPT 1/2" 50 56 96480625<br />

Hose clamp 16/- 17 64 135 96440533<br />

Pipe cementing -/20 20 64 94 96440537<br />

Hose clamp 16/- 16 64 135 96446856<br />

Threaded<br />

-/Rp 1/2" Rp 1/2" 64 94 96446857<br />

-/NPT 1/2" NPT 1/2" 64 94 96480627<br />

PP EPDM<br />

33/42 57 167 96527115<br />

PP FKM Glass Hose clamp<br />

32/41<br />

38/48<br />

33/42 57 167 96527116<br />

PVDF FKM 33/42 57 167 96527118<br />

Stainl.<br />

steel<br />

FKM Stainl. steel Threaded RP 1 1/4" RP 1 1/4" 57 167 96534454<br />

PVC FKM Glass<br />

Stainl.<br />

steel<br />

Materials Connection Dimensions<br />

Size Housing Gasket Ball Type<br />

CSM Stainl. steel<br />

Hose clamp 25/- 26 90 175 96440534<br />

Pipe cementing -/32 32 90 120 96440538<br />

Hose clamp 25/- 26 90 175 96446858<br />

Threaded<br />

Inner/outer<br />

tubing or pipe<br />

diameters<br />

d ø<br />

[mm]<br />

L<br />

[mm]<br />

Product<br />

number<br />

-/Rp 1" Rp 1" 90 120 96446859<br />

-/NPT 1" NPT 1" 90 120 96480628<br />

Foot valve<br />

Valve kit


<strong>Accessories</strong><br />

Injection valve<br />

Injection valve complete with spring-loaded non-return<br />

valve, injection pipe and tube or pipe connection.<br />

Spring material: Hastelloy C22<br />

Opening pressure:<br />

DN 4, DN 8: 0.7 bar<br />

DN 6, DN 10,<br />

DN 15, DN 25: 1.1 bar.<br />

Maximum temperature:<br />

PP, PVDF: 50°C<br />

PVC: 40°C<br />

Stainless steel: 80°C.<br />

Dimensions<br />

d<br />

Max. flow rate<br />

[l/h]<br />

DN 4, DN 8 DN 6, DN 10, DN 15, DN 20, DN 25<br />

L<br />

Size<br />

12 DN 4<br />

Non-return valve<br />

TM01 9278 3100 - TM02 6434<br />

Material Connection Dimensions<br />

Housing Gasket Ball Type<br />

PP EPDM Ceramic Tubing<br />

PP FKM Ceramic Tubing<br />

PV FKM Ceramic Tubing<br />

TM01 9279 1600<br />

Inner/outer tubing or<br />

pipe diameters<br />

d<br />

L<br />

[mm]<br />

Injection valve<br />

Product<br />

number<br />

4/6 G 1/2" 33 96440576<br />

6/9 G 1/2" 33 96440577<br />

0.17"/1/4" NPT 1/2" 33 96480641<br />

1/4"/3/8" NPT 1/2" 33 96479805<br />

4/6 G 1/2" 33 96446739<br />

6/9 G 1/2" 33 96446740<br />

0.17"/1/4" NPT 1/2" 33 96480642<br />

1/4"/3/8" NPT 1/2" 33 96479806<br />

4/6 G 1/2" 33 96440581<br />

6/9 G 1/2" 33 96440582<br />

0.17"/1/4" NPT 1/2" 33 96480643<br />

1/4"/3/8" NPT 1/2" 33 96479807<br />

GR8107 - GR7098<br />

Valve kit<br />

96499608<br />

96499609<br />

96499600<br />

45


46<br />

<strong>Accessories</strong><br />

Max. flow rate<br />

[l/h]<br />

72 DN 8<br />

72 DN6<br />

150 DN 10<br />

940<br />

Size<br />

PP EPDM Ceramic<br />

PP FKM Ceramic<br />

PV FKM Ceramic<br />

Stainl.<br />

steel<br />

AF<br />

Stainl.<br />

steel<br />

Tubing<br />

Pipe cementing<br />

Tubing<br />

Tubing<br />

Pipe cementing<br />

Tubing<br />

Tubing<br />

Pipe cementing<br />

Tubing<br />

6/9 G 1/2" 33 96446736<br />

9/12 G 1/2" 33 96440578<br />

-/10 G 1/2" 33 96440574<br />

-/12 G 1/2" 33 96440575<br />

1/4"/3/8" NPT 1/2" 33 96480644<br />

3/8"/1/2" NPT 1/2" 33 96480645<br />

6/9 G 1/2" 33 96446741<br />

9/12 G 1/2" 33 96446880<br />

-/10 G 1/2" 33 96446737<br />

-/12 G 1/2" 33 96446738<br />

1/4"/3/8" NPT 1/2" 33 96480646<br />

3/8"/1/2" NPT 1/2" 33 96479808<br />

6/9 G 1/2" 33 96446742<br />

9/12 G 1/2" 33 96440583<br />

-/10 G 1/2" 33 96440579<br />

-/12 G 1/2" 33 96440580<br />

1/4"/3/8" NPT 1/2" 33 96480647<br />

3/8"/1/2" NPT 1/2" 33 96479809<br />

Hose clamp 6/- G 1/2" 100 96446878<br />

Threaded<br />

-/Rp 1/4" G 1/2" 100 96446879<br />

-/NPT 1/4" NPT 1/2" 100 96479804<br />

-/NPT 1/2" NPT 1/2" 100 96480629<br />

PP EPDM<br />

G 3/4" 105 96527119<br />

PP FKM Ceramics Hose clamp<br />

19/27<br />

25/34<br />

G 3/4" 105 96527120<br />

PVDF FKM G 3/4" 105 96527121<br />

PVC FKM Glass<br />

Stainl<br />

steel<br />

FKM<br />

Stainl<br />

steel<br />

Hose clamp<br />

Pipe cementing<br />

9/- G 1" 100 96440568<br />

16/- G 1" 100 96440567<br />

-/12 G 1" 100 96440565<br />

-/16 G 1" 100 96440566<br />

Threaded RP 3/4" G 3/4" 105 96534457<br />

Hose clamp 9/- G 1" 100 96446875<br />

AF<br />

Threaded<br />

-/Rp 3/8"<br />

-/Rp 1/2"<br />

G 1"<br />

G 1"<br />

100<br />

100<br />

96446876<br />

96446877<br />

-/3/8"NPT NPT 1" 100 96480640<br />

Hose clamp 16/- G 1" 100 96440571<br />

375 DN 15 PVC FKM Glass<br />

Pipe cementing<br />

-/16<br />

-/20<br />

G 1"<br />

G 1"<br />

100<br />

100<br />

96440569<br />

96440570<br />

PP EPDM<br />

G 1" 98 96527122<br />

DN20<br />

PP<br />

PVDF<br />

FKM<br />

FKM<br />

Glass Hose clamp<br />

32/41<br />

38/48<br />

G 1"<br />

G 1"<br />

98<br />

98<br />

96527123<br />

96527124<br />

Stainl<br />

steel<br />

FKM<br />

Stainl<br />

steel<br />

Threaded RP 1 1/4" G 1" 98 96534459<br />

DN 25 PVC FKM PVDF<br />

Material Connection Dimensions<br />

Housing Gasket Ball Type<br />

Hose clamp<br />

Pipe cementing<br />

Inner/outer tubing or<br />

pipe diameters<br />

d<br />

L<br />

[mm]<br />

25/- G 1 1/2" 100 96440573<br />

25"/- NPT NPT 1.5" 100 96480649<br />

-/32 G 1 1/2" 100 96440572<br />

-/32" NPT NPT 1.5" 100 96480648<br />

Injection valve<br />

Product<br />

number<br />

Valve kit<br />

96499601<br />

96499602<br />

96499603


<strong>Accessories</strong><br />

Hot injection valve<br />

Complete hot injection valve kit assembly with shut-off<br />

valve, pipe and tubing connection fitting for chemical<br />

injection into steam and hot water application.<br />

The hot injection valve assembly allows for direkt<br />

dosing injection into systems with temperature of max.<br />

150°C at the injection valve point.<br />

The hot injection valve kit is delivered non-assembled<br />

to facilitate adaptation to the actual application.<br />

Materials:<br />

Shut-off ball valve SS 1.4401<br />

Pipe SS 1.4401<br />

Pipe connection SS 1.4401<br />

Tubing connection PVDF<br />

Max. injection point temperature<br />

Dimensions:<br />

150°C<br />

Shut-off ball valve 1/2"<br />

Pipe 8/10 mm<br />

Pipe connection 1/2"<br />

Tubing connection 6/9.<br />

GR 7506<br />

Hot injection valve<br />

Max. flow rate [l/h] Size<br />

Connection<br />

Material<br />

Gasket Ball Type<br />

Connection<br />

Tubing diameter<br />

Product number<br />

20 DN 4 PVDF FKM Ceramic Tubing 6/9 96534472<br />

47


48<br />

<strong>Accessories</strong><br />

Multifunction valve<br />

Compact valve unit for direct mounting on the pump<br />

discharge connection. The valve has four functions:<br />

1. Constant counter-pressure<br />

2. Anti-siphoning<br />

3. Pump protection<br />

4. Manual pressure relief.<br />

Relief pressure: 11 bar<br />

Constant counter pressure: 1.5 bar<br />

Maximum volume: 50 l/h.<br />

Dimensions<br />

Pump type<br />

DME and DMS a)<br />

DME and DMS<br />

up to 48 l/h<br />

Multifunction valve<br />

Housing<br />

Materials<br />

Gasket Diaphragm A<br />

Dimensions<br />

E<br />

Product number<br />

PVDF FKM FKM M28 x 2 M28 x 2 96497411<br />

PP<br />

EPDM<br />

FKM<br />

EPDM<br />

FKM<br />

M30 x 3.5<br />

M30 x 3.5<br />

M30 x 3.5<br />

M30 x 3.5<br />

96440584<br />

96440585<br />

PVDF FKM FKM M30 x 3.5 M30 x 3.5 96440586<br />

PVC<br />

a) M28 x 2 fits stainless steel pump heads.<br />

EPDM EPDM M30 x 3.5 M30 x 3.5 96496470<br />

FKM FKM M30 x 3.5 M30 x 3.5 96446752<br />

TM01 9583 2100 - TM01 8961 0900<br />

TM01 2220 1498


<strong>Accessories</strong><br />

Dosing monitor<br />

The dosing monitor is used in connection with the<br />

dosing monitoring function of DME and DMS-A, AR<br />

pumps.<br />

The monitor sends a pulse signal (closed contact) for<br />

every measured dosing stroke.<br />

As the DME pump will often operate without pulsation<br />

on the discharge side, the monitor must always be<br />

installed on the suction side.<br />

The monitor for a DMS pump can be installed on both<br />

suction and discharge side.<br />

Maximum pressure: 10 bar<br />

Maximum volume: 50 l/h<br />

Maximum liquid temperature: 35°C<br />

Maximum liquid viscosity: 20 mPas<br />

Maximum load of pulse<br />

transmitter (reed contact): 48 VAC/VDC, 0.5 A<br />

Materials in contact with liquid: PMMA/PVC/FKM.<br />

Selection table<br />

Dosing stroke<br />

measured<br />

Monitor mounted on suction<br />

side (DME and DMS)<br />

Dosing stroke<br />

measured<br />

Monitor mounted on discharge<br />

side (DMS only)<br />

Dosing stroke<br />

measured<br />

Monitor mounted in dosing tube.<br />

In discharge tube: DMS<br />

In suction tube: DME and DMS<br />

Dosing monitor<br />

Mounting Pump head Gasket Connection kit Product number<br />

In-line PP, PVDF<br />

Discharge side a) PP, PVDF<br />

Suction side PP, PVDF<br />

a) Not suitable for DME pumps.<br />

Not suitable for stainless steel pump heads.<br />

FKM<br />

4/6, 6/9, 9/12 mm<br />

0.17"/1/4", 1/4"/3/8", 3/8"/1/2"<br />

96470722<br />

96470726<br />

FKM 4/6, 6/9, 9/12 mm 96470721<br />

FKM<br />

EPPM<br />

0.17"/1/4", 1/4"/3/8", 3/8"/1/2"<br />

96470725<br />

96493010<br />

FKM Not needed<br />

96470723<br />

EPPM Pump connection is used for monitor<br />

96492899<br />

FKM Not needed<br />

96470724<br />

EPPM Pump connection is used for monitor<br />

96493011<br />

TM02 2472 4401<br />

TM02 2029 3201 - TM02 2030 3201 - TM02 2031 320 1<br />

49


50<br />

<strong>Accessories</strong><br />

Flow indicator<br />

The flow indicator is used for discharge monitoring.<br />

When the dosing pump is discharging liquid, the white<br />

ball will jump in the transparent pipe. Each dosing<br />

stroke causes a ball jump. The design of the flow indicator<br />

allows ball movements to be seen at flow rates<br />

from 0.1 to 45 l/h.<br />

At a steady flow, the ball will always be in the top position.<br />

The flow indicator installs and retrofits easily.<br />

Material: PVC grey, PVC transparent,<br />

PVDF, FKM, ceramic AI2O3. Maximum pressure: 10 bar<br />

Maximum pulsed flow: 45 l/h.<br />

Dimensions<br />

Pump type<br />

DME and DMS<br />

up to 48 l/h<br />

TM01 9791 3100<br />

TM01 9800 3200<br />

Dimensions<br />

A B C [mm] D [mm]<br />

Flow indicator<br />

Product number<br />

M30 x 3.5 M30 x 3.5 44 55 96446763


<strong>Accessories</strong><br />

Pump connections<br />

Separate, retrofit pump connections for adapting<br />

standard Grundfos pumps to installation-specific<br />

tubing, pipe types and sizes.<br />

The product number includes one connection with<br />

union.<br />

GR6987<br />

Pump connections<br />

For pump type Connection type Inner/outer tubing or pipe diameters/thread Material Product number<br />

DME 2<br />

DME 8<br />

DME 12<br />

DME 19<br />

DME 48<br />

DMS 2<br />

DMS 4<br />

DMS 8<br />

DMS 12<br />

Tubing<br />

Pipe cementing<br />

Inner thread<br />

4/6<br />

6/9<br />

6/12<br />

9/12<br />

DME 60-150 Hose clamp 19/27 + 25/34<br />

DME 375-940 Hose clamp 32/41 + 38/48<br />

Fits only stainless steel pumps.<br />

Polypropylene 96440468<br />

PVDF 96440469<br />

Polypropylene 96440470<br />

PVDF 96440471<br />

Polypropylene 96440472<br />

PVDF 96440473<br />

Polypropylene 96440474<br />

PVDF 96440475<br />

–/10 PVC 96440462<br />

–/12 PVC 96440464<br />

PVC 96440456<br />

–/Rp 1/4"<br />

PVDF<br />

St. steel 1.4401<br />

96440457<br />

964846 70<br />

St. steel 1.4401 96440458 *<br />

–/Rp 3/8" St. steel 1.4401 96440461 *<br />

PP 96535096<br />

PVDF 96535102<br />

PP 96535103<br />

PVDF 96535104<br />

51


52<br />

<strong>Accessories</strong><br />

Adaptor<br />

The adaptors are used for the connection of DME and<br />

DMS pumps to suction and discharge tubing sizes other<br />

than Grundfos standard sizes.<br />

The product number comprises two sets.<br />

Inner/outer tubing<br />

diameter<br />

Connection<br />

type<br />

Material<br />

Product<br />

number<br />

4/6<br />

PP<br />

PVDF<br />

96434861<br />

96434862<br />

6/9<br />

PP<br />

PVDF<br />

96434863<br />

96434865<br />

6/12<br />

PP<br />

PVDF<br />

96460449<br />

96460450<br />

9/12<br />

PP<br />

PVDF<br />

96460447<br />

96460448<br />

5/8<br />

Tubing<br />

PP<br />

PVDF<br />

96460434<br />

96460435<br />

6/8<br />

PP<br />

PVDF<br />

96460436<br />

96460437<br />

0.17"/1/4"<br />

PP<br />

PVDF<br />

96460438<br />

96460439<br />

1/4"/3/8"<br />

PP<br />

PVDF<br />

96460443<br />

96460444<br />

3/8"/1/2"<br />

PP<br />

PVDF<br />

96460445<br />

96460446<br />

12/-<br />

PP<br />

PVDF<br />

96534491<br />

96534493<br />

19/27<br />

Hose PP 96535109<br />

25/34<br />

clamp PVDF 96535110<br />

32/41<br />

PP 96535111<br />

38/48<br />

PVDF 96535112<br />

Rp 3/4"<br />

PVC 96533886<br />

Rp 1 1/4" PVC 96534799<br />

Rp 3/4” SS 96575256<br />

Rp 1 1/4” Inner SS 96575258<br />

NPT 3/4” thread PVC 96537892<br />

NPT 1 1/4” PVC 96567893<br />

NPT 3/4” SS 96537894<br />

NPT 1 1/4” SS 96537895<br />

TM02 2470 4401<br />

Adaptor


<strong>Accessories</strong><br />

Rigid suction line<br />

Pre-assembled rigid suction line with adjustable length<br />

for mounting in a tank. The suction line consists of foot<br />

valve with strainer, rigid suction pipe, tank connection<br />

thread and suction tube.<br />

For control variant A, the suction line is available with<br />

level sensors (NO-contacts) for warning and emptytank<br />

signals, supplied complete with cable and plug for<br />

pump connection.<br />

Material: PVC<br />

Material, wetted parts: PVC, glass<br />

Suction tubing length: 1.5 m, PVC-tube<br />

Level cable length: 1.5 m<br />

Level plug type: M12, 4-pole<br />

Maximum flow: 50 l/h<br />

Maximum load of<br />

level contacts: 50 V, 0.5 A<br />

Function of level contacts:<br />

Low level/empty tank = closed contact<br />

Black PE screw cap for ø33.5: 96483418.<br />

TM02 4551 1102/TM01 9288 1600<br />

Rigid suction line<br />

53


54<br />

<strong>Accessories</strong><br />

Dimensions<br />

With level sensors Without level sensors<br />

Maximum length L [mm] For Grundfos tank size [l] Inner/outer suction tubing diameters [mm]<br />

540 60<br />

750 100<br />

800 200<br />

900 300<br />

1125 500<br />

1250 1000<br />

TM01 2202 4701<br />

TM01 2377 1498<br />

Rigid suction line<br />

Product number<br />

With level sensors Without level sensors<br />

4/6 96441230 96417398<br />

6/9 96441236 96417401<br />

9/12 96449875 96449869<br />

0.17"/1/4" 96480729 96480710<br />

1/4"/3/8" 96479974 96480716<br />

3/8"/1/2" 96480737 96480723<br />

4/6 96441231 96446734<br />

6/9 96441237 96446735<br />

9/12 96449876 96449870<br />

0.17"/1/4" 96480730 96480711<br />

1/4"/3/8" 96480734 96480717<br />

3/8"/1/2" 96480738 96480724<br />

4/6 96441232 96417399<br />

6/9 96441238 96417402<br />

9/12 96449877 96449871<br />

0.17"/1/4" 96480731 96480712<br />

1/4"/3/8" 96479975 96480718<br />

3/8"/1/2" 96480739 96480725<br />

4/6 96441233 96441222<br />

6/9 96441239 96441224<br />

9/12 96449878 96449872<br />

0.17"/1/4" 96480732 96480713<br />

1/4"/3/8" 96480735 96480719<br />

3/8"/1/2" 96480000 96480726<br />

4/6 96441228 96421285<br />

6/9 96441234 96421286<br />

9/12 96449873 96449867<br />

0.17"/1/4" 96480727 96480707<br />

1/4"/3/8" 96479973 96480714<br />

3/8"/1/2" 96479999 96480720<br />

4/6 96441229 96417400<br />

6/9 96441235 96417403<br />

9/12 96449874 96449868<br />

0.17"/1/4" 96480728 96480709<br />

1/4"/3/8" 96480733 96480715<br />

3/8"/1/2" 96480736 96480721


<strong>Accessories</strong><br />

Level control unit<br />

For dosing pumps with level control input (variant A),<br />

complete with level sensors (NO-contacts), ceramic<br />

weight, cable and plug for pump connection.<br />

Material: PVC<br />

Level cable length: 2.5 m<br />

Level plug type: M12, 4-pole<br />

Maximum load of<br />

level contacts: 50 V, 0.5 A<br />

Function of level contacts:<br />

Low level/empty tank = closed contact<br />

Product number: 96440539.<br />

TM01 9587 2100<br />

Dimensions<br />

Level control unit<br />

TM01 9567 1600<br />

55


56<br />

<strong>Accessories</strong><br />

Counter-pressure or relief valve<br />

Adjustable valve for installation in the discharge tube.<br />

• Installed in-line, the valve functions as a counterpressure<br />

valve optimising dosing accuracy into systems<br />

with fluctuating pressure or as anti-siphoning<br />

valve when dosing into pressureless systems.<br />

• Installed in a T-connection with the valve outlet connected<br />

to the tank, the valve functions as a pressure<br />

relief valve or a safety valve, protecting the pump<br />

and the discharge tube against excessive pressures.<br />

Pressure range: 0-10 bar<br />

Diaphragm material: PTFE.<br />

Counter-pressure or relief valve<br />

TM01 9289 1600


<strong>Accessories</strong><br />

Counter-pressure or relief valve<br />

Size<br />

DN 6, DN 10, DN 15 DN 25, DN 32, DN 40<br />

Maximum<br />

flow rate [l/h]<br />

DN 6 25 Rp 1/4" 40 142<br />

DN 10 75 Rp 3/8" 55 147<br />

TM01 9290 1600<br />

A<br />

Dimensions<br />

C [mm] H [mm]<br />

Housing material<br />

Type<br />

PVC<br />

PVDF<br />

Counter-pressure or relief valve<br />

Connections<br />

TM01 9291 1600<br />

Inner/outer tubing or pipe<br />

diameters/thread<br />

Product number<br />

4/6 96440823<br />

6/9 96440825<br />

6/12 96440824<br />

Tubing<br />

9/12 96489009<br />

0.17"/1/4" 96487951<br />

1/4"/3/8" 96487906<br />

1/4"/1/2" 96487905<br />

Pipe cementing -/10 96440821<br />

Inner thread<br />

-/Rp 1/4" 96440822<br />

1/4" NPT 96487950<br />

4/6 96440828<br />

6/9 96440830<br />

Tubing<br />

6/12<br />

0.17"/1/4"<br />

96440829<br />

96487908<br />

1/4"/3/8" 96487972<br />

1/4"/1/2" 96487970<br />

Pipe cementing -/10 96440826<br />

Inner thread<br />

St. steel 1.4571 Inner thread<br />

PVC<br />

PVDF<br />

St. steel 1.4571<br />

-/Rp 1/4" 96440827<br />

1/4" NPT 96487907<br />

-/Rp 1/4" 96440831<br />

-1/4" NPT 96487973<br />

6/9 96449892<br />

Tubing<br />

6/12 96504917<br />

1/4"/3/8" 96487899<br />

Hose clamp 9/- 96440799<br />

Pipe cementing<br />

Inner thread<br />

-/12 96440796<br />

-/16 96440797<br />

-/Rp 3/8" 96440798<br />

-/3/8" NPT 96487898<br />

Tubing<br />

6/9<br />

1/4"/3/8"<br />

96449893<br />

96487941<br />

Hose clamp 9/- 96440803<br />

Pipe cementing<br />

Inner thread<br />

-/12 96440800<br />

-/16 96440801<br />

-/Rp 3/8" 96440802<br />

-/3/8" NPT 96487940<br />

Hose clamp 9/- 96440805<br />

Inner thread<br />

-/Rp 3/8" 96440804<br />

-3/8" NPT 96487942<br />

57


58<br />

<strong>Accessories</strong><br />

Size<br />

Maximum<br />

flow rate [l/h]<br />

DN 15 210 Rp 1/2" 75<br />

152<br />

130<br />

DN 25 390 Rp 1 140 240<br />

DN 32 640 Rp 1 1/4" 140<br />

DN 40 990 Rp 11/2" 152<br />

For stainless steel 1.4571<br />

A<br />

Dimensions<br />

C [mm] H [mm]<br />

Housing material<br />

Type<br />

242<br />

165<br />

252<br />

180<br />

PVC<br />

PVDF<br />

Counter-pressure or relief valve<br />

Hose clamp 16/- 96440807<br />

Pipe cementing -/20 96440806<br />

Inner thread<br />

-/Rp 1/2" 96440808<br />

-/1/2" NPT 96487943<br />

Hose clamp 16/- 96440810<br />

Pipe cementing -/20 96440809<br />

Inner thread<br />

St. steel 1.4571 Hose clamp<br />

PP<br />

-/Rp 1/2" 96440811<br />

-/1/2" NPT 96487944<br />

16/- 96440812<br />

-/Rp 1/2" 96440813<br />

-/1/2" NPT 96487945<br />

Hose clamp 25/- 96440815<br />

Inner thread<br />

St. steel 1.4571 Inner thread<br />

Connections<br />

Inner/outer tubing or pipe<br />

diameters/thread<br />

Product number<br />

-/Rp 1 96440814<br />

1/2" NPT 96487897<br />

-1"/ NPT 96487946<br />

-/Rp 1 96440816<br />

-/1" NPT 96487947<br />

PP Inner thread<br />

-/Rp 1 1/4"<br />

-/1 1/4" NPT<br />

96440817<br />

96487948<br />

St. steel 1.4571 Flange DN 32 96440818<br />

PP Inner thread<br />

-/Rp 1 1/2"<br />

-/1 1/2" NPT<br />

96440819<br />

96487949<br />

St. steel 1.4571 Flange DN 40 96440820


<strong>Accessories</strong><br />

Valve assembly<br />

Complete assembly of:<br />

• counter-pressure and relief valve or<br />

• relief and isolating valve.<br />

Valve diaphragm material: PTFE<br />

Pressure range of counter-pressure and relief valve:<br />

0-10 bar.<br />

TM01 9588 2100<br />

Valve assembly<br />

59


60<br />

<strong>Accessories</strong><br />

Counter-pressure and isolating valve/relief valve<br />

Valve functions Size<br />

Counter-pressure<br />

and isolating valve<br />

Counter-pressure<br />

and relief valve<br />

TM01 9589 1600<br />

TM01 9590 2100<br />

Maximum<br />

flow rate<br />

[l/h]<br />

DN6 25<br />

DN10 75<br />

DN15 210<br />

DN6 25<br />

DN10 75<br />

DN15 210<br />

Housing<br />

material<br />

TM01 9292 1600<br />

Counter-pressure and isolating valve/relief valve<br />

Type<br />

Connections Dimensions<br />

Inner/outer tubing or<br />

pipe diameters/<br />

thread<br />

A<br />

H<br />

[mm]<br />

TM01 9293 1600<br />

Product<br />

number<br />

4/6<br />

96440643<br />

PVC<br />

Tubing<br />

6/9<br />

6/12<br />

9/12 Rp 1/4" 155<br />

96440645<br />

96440644<br />

96488892<br />

Pipe cementing -/10 96440641<br />

Inner thread -/Rp 1/4" 96440642<br />

St.steel 1.4571 Inner thread -/Rp 1/4" 96440646<br />

PVC<br />

St.steel 1.4571<br />

PVC<br />

St.steel 1.4571<br />

Tubing 6/9<br />

96449895<br />

Hose clamp 9/- 96440596<br />

Pipe cementing<br />

-/12<br />

-/16 Rp 3/8"<br />

174<br />

96440593<br />

96440594<br />

Inner thread -/Rp 3/4" 96440595<br />

Hose clamp -/Rp 3/8" 96440598<br />

Inner thread -/Rp 1/4" 166 96440597<br />

Hose clamp 16/-<br />

96440600<br />

Pipe cementing<br />

Inner thread<br />

-/20<br />

-/Rp 1/2" Rp 1/2"<br />

180<br />

96440599<br />

96440601<br />

Hose clamp 16/- 96440602<br />

Inner thread -/Rp 1/2" 163 96440603<br />

4/6<br />

96440845<br />

PVC<br />

Tubing<br />

6/9<br />

6/12<br />

9/12 Rp 1/4" 155<br />

96440847<br />

96440846<br />

96489142<br />

Pipe cementing -/10 96440843<br />

Inner thread -/Rp 1/4" 96440844<br />

St.steel 1.4571 Inner thread -/Rp 1/4" 96440848<br />

PVC<br />

St.steel 1.4571<br />

PVC<br />

St.steel 1.4571<br />

Tubing 6/9<br />

96449894<br />

Hose clamp 9/- 96440835<br />

Pipe cementing<br />

-/12<br />

-/16 Rp 3/8"<br />

174<br />

96440832<br />

96440833<br />

Inner thread -/Rp 3/8" 96440834<br />

Hose clamp 9/- 96440837<br />

Inner thread -/Rp 3/8" 166 96440836<br />

Hose clamp 16/-<br />

96440839<br />

Pipe cementing<br />

Inner thread<br />

-/20<br />

-/Rp 1/2" Rp 1/2"<br />

180<br />

96440838<br />

96440840<br />

Hose clamp 16/- 96440841<br />

Inner thread -/Rp 1/2" 163 96440842


<strong>Accessories</strong><br />

Vent valve<br />

Manual vent valve for direct fiting into the DME and<br />

DMS pump heads up to 48 l/h.<br />

Pump type<br />

DME 2, DME 8<br />

DME 12, DME 19<br />

DME 48<br />

DMS 2, DMS 4<br />

DMS 8, DMS 12<br />

GR 8210<br />

Valve materials<br />

Housing Gasket Ball<br />

Venting valve<br />

Vent pipe Product number<br />

PP EPDM<br />

96534792<br />

PP FKM<br />

Ceramic 4/6<br />

96534794<br />

PV FKM 96534796<br />

61


62<br />

<strong>Accessories</strong><br />

Automatic vent valve<br />

Automatic vent valve for direct fitting on the pump<br />

discharge connection.<br />

Valve housing material: PMMA/PVC<br />

O-ring material: FKM<br />

Valve ball material: Glass<br />

Valve seat material: PVDF<br />

Pump head material: PP/PVDF<br />

Power cable length: 1.5 m<br />

Opening pressure: 10 bar<br />

Maximum flow: 45 l/h<br />

Supply voltage: 115/230 V, 50/60 Hz<br />

Plug type: EU (Schuko).<br />

The valve is available with and without timer.<br />

With timer:<br />

The valve is continuously connected to the power<br />

supply. The opening time and opening intervals are set<br />

on the timer.<br />

Without timer:<br />

The valve will open when power is supplied to the valve.<br />

This version is ideal for operation in connection with a<br />

dosing monitor.<br />

TM01 9591 2100/TM01 9592 2100<br />

Automatic vent valve


<strong>Accessories</strong><br />

Automatic vent valve (with timer)<br />

Pump type<br />

DME DMS<br />

up to 48 l/h<br />

A<br />

B<br />

Dimensions<br />

A + B<br />

M30 x 3.5<br />

Voltage Plug<br />

Automatic vent valve (with timer)<br />

Product number<br />

With timer Without timer<br />

Schuko (DIN) 96441085 96471079<br />

1 x 230 V, 50-60 Hz<br />

Switzerland<br />

UK<br />

96470743<br />

96471067<br />

96471080<br />

96471083<br />

Australia 96470744 96471085<br />

1 x 120 V, 50-60 Hz US 96441084 96471086<br />

TM01 2218 1498<br />

63


64<br />

<strong>Accessories</strong><br />

Pulsation dampener<br />

For the installation in the suction and the discharge<br />

tube, the pulsation pressure surges, and ensuring a<br />

steady flow. The dampener is particularly suitable for<br />

long discharge tubes and/or lines with a small diameter.<br />

Installed in the discharge tube, the dampener can be<br />

used for optimising dosing accuracy and for protection<br />

of pump and discharge line against pressure surges.<br />

Depending on the system pressure, it may be necessary<br />

to install a counter-pressure valve after the dampener<br />

to optimise its function.<br />

Maximum pressure: 10 bar.<br />

TM01 9593 2100<br />

Pulsation dampener


<strong>Accessories</strong><br />

Pulsation dampener<br />

Size<br />

Maximum<br />

flow rate<br />

[l/h]<br />

80 60<br />

250 150<br />

750 375<br />

2500 940<br />

Pulsation dampener<br />

Size 80 Size 250 Sizes 750 and 2500<br />

TM01 2206 1498<br />

Materials Connections Dimensions [mm]<br />

Housing Diaphragm Type<br />

PP<br />

PVC<br />

PP<br />

PVC<br />

PP<br />

PVC<br />

PP<br />

PVC<br />

Inner/outer tubing<br />

or pipe diameters/<br />

thread<br />

TM01 2207 1498<br />

A B C D E<br />

TM01 22081498<br />

Product<br />

number<br />

CSM Tubing<br />

6/9<br />

9/12<br />

96441075<br />

96488893<br />

FKM Tubing 6/9 96441074<br />

CSM Tubing<br />

FKM Tubing<br />

CSM<br />

FKM<br />

CSM<br />

FKM<br />

CSM<br />

FKM<br />

CSM<br />

FKM<br />

6/9 172 G 3/4" M6 50 96441077<br />

1/4"/3/8" 96480706<br />

6/9 96441076<br />

1/4"/3/8" 96479972<br />

Inner thread -/Rp 1/2"<br />

96440850<br />

Inner thread -/1/2" NPT 96480694<br />

Inner thread -/Rp 1/2" 96440849<br />

Inner thread<br />

Inner thread<br />

-/1/2" NPT<br />

-/Rp 1/2"<br />

314 140 G 1 1/4" M8 58<br />

96480693<br />

96440854<br />

Inner thread -/1/2" NPT 96480696<br />

Inner thread -/Rp 1/2" 96440852<br />

Inner thread -/1/2" NPT 96480695<br />

Inner thread -/Rp 1/2"<br />

96441071<br />

Inner thread -/1/2" NPT 96480700<br />

Inner thread -/Rp 1/2" 96441070<br />

Inner thread<br />

Inner thread<br />

-/1/2" NPT<br />

-/Rp 1/2"<br />

363 347 G 1 1/4" ø9 72<br />

96480698<br />

96441073<br />

Inner thread -/1/2" NPT 96480704<br />

Inner thread -/Rp 1/2" 96441072<br />

Inner thread -/1/2" NPT 96480703<br />

CSM Pipe cementing -/40<br />

96440856<br />

FKM<br />

CSM<br />

Pipe cementing<br />

Pipe cementing<br />

-/40<br />

-/40<br />

541 525 G 2 ø11 126<br />

96440855<br />

96440858<br />

FKM Pipe cementing -/40 96440857<br />

65


66<br />

<strong>Accessories</strong><br />

<strong>Accessories</strong> for pulsation dampeners<br />

Connector<br />

For direct fitting of pulsation dampener size 80 to pump<br />

discharge connection.<br />

Pump type A B C Product number<br />

DME<br />

DMS<br />

Rp 3/4" M30 32 96441089<br />

Dummy plug<br />

For installation of pulsation dampener in T-piece<br />

connection.<br />

Pulsation dampener<br />

size<br />

Dimension [mm]<br />

A<br />

Product number<br />

80 Rp 3/4" 96441092<br />

250, 750 Rp 1 1/4" 96441091<br />

2500 Rp 2 96441090<br />

Pressure gauge<br />

For measuring gas pressure in pulsation dampener.<br />

Pressure range Product number<br />

0-6 bar 96441096<br />

0-16 bar 96441095<br />

TM01 9596 2100<br />

TM01 2209 1498<br />

<strong>Accessories</strong> for pulsation dampeners<br />

TM01 9594 2100<br />

TM01 9595 2100<br />

TM01 2212 1498<br />

TM01 2211 1498


<strong>Accessories</strong><br />

Priming aid<br />

The priming aid is a transparent, air-tight collector with<br />

a screw cap on top. It is mounted between the tank and<br />

the pump. The inlet from the tank and the outlet to the<br />

pump are both at the bottom of the collector.<br />

The priming aid is supplied with a bracket for wall<br />

mounting and a rod for mounting on top of the tank.<br />

The priming aid has the following functions:<br />

• Priming.<br />

The priming aid facilitates priming in case of frequent<br />

stops and/or high suction lifts by eliminating<br />

or reducing the dry-suction phase.<br />

• Gas trap.<br />

Gas occurring in the suction tube is trapped in the<br />

top of the priming aid to prevent it from entering the<br />

dosing head.<br />

• Pulsation dampening.<br />

The dampening gas cushion in the top of the priming<br />

aid reduces pressure surges, resulting in optimum<br />

dosing accuracy and reduced risk of<br />

cavitation.<br />

Material: PVC.<br />

TM01 9597 2100<br />

Priming aid<br />

67


68<br />

<strong>Accessories</strong><br />

Priming aid<br />

Size/priming capacity [ml]<br />

95<br />

250<br />

Size 95 Size 250<br />

TM01 2214 1498<br />

Connections<br />

Type Inner/outer tubing diameters<br />

Tubing<br />

TM01 2216 1498<br />

Priming aid<br />

Product number<br />

4/6 96441079<br />

6/9 96441080<br />

0.17"/1/4" 96480692<br />

1/4"/3/8" 96479970<br />

6/9 96441078<br />

9/12 96483949<br />

1/4"/3/8" 96480690


<strong>Accessories</strong><br />

Tank<br />

Closed cylindrical tank with screw cap and threaded<br />

connection for rigid suction line.<br />

Material: PE.<br />

Liquid temperature: Minimum: –20°C.<br />

Maximum: +45°C.<br />

Pump mounting plate:<br />

The DME and DMS pumps can be mounted direct on<br />

the tank top by means of adapter plates.<br />

Material: PP.<br />

DME 2 to DME 12 and DMS: 96446765.<br />

DME 19 and DME 48: 96446766.<br />

Floor mounting bracket:<br />

Material: PE.<br />

Set of four: 96446767.<br />

TM01 9598 2100<br />

Tank<br />

69


70<br />

<strong>Accessories</strong><br />

Dimensions<br />

Floor mounting bracket<br />

Tank size [l]<br />

D<br />

Dimensions [mm]<br />

H<br />

Weight [kg] Product number<br />

60 415 575 4.5 96417362<br />

100 470 790 7.0 96417363<br />

200 600 845 13.0 96417364<br />

300 675 950 15.0 96441296<br />

500 815 1080 27.0 96417365<br />

1000<br />

Without pump mounting holes.<br />

1080 1358 39.0 96417366<br />

Tank<br />

TM01 2219 1498


<strong>Accessories</strong><br />

100-litre tank<br />

Closed square tank with screw cap and mounting platform<br />

for single or parallel pump mounting.<br />

The pump mounting platform is raised above the screw<br />

cap to protect pumps and connections when filling<br />

chemical into the tank.<br />

The height difference also allows for direct mounting of<br />

the dosing monitor on the suction side.<br />

Material: MDPE<br />

Weight: 15 kg<br />

Max. material temperature: +50°C<br />

Liquid temperature: Minimum –20°C<br />

Maximum +45°C.<br />

Mounting platform<br />

DME and DMS pumps can be fitted direct on the platform<br />

by means of brass inserts moulded into the platform.<br />

Mounting combination<br />

Single or parallel mounting of DME 0-48 l/h and DMS.<br />

The tank is prepared for the fitting of a 3/4" RG draining<br />

plug.<br />

Material thickness: 4 mm.<br />

Tank size Product number<br />

100 l 96489271<br />

GR7309<br />

100-litres tank<br />

71


72<br />

<strong>Accessories</strong><br />

Dimensions [mm]<br />

500 540<br />

ø152<br />

500<br />

137<br />

192<br />

670<br />

M5<br />

98<br />

98<br />

98<br />

TM02 6616 1103<br />

100-litres tank


<strong>Accessories</strong><br />

Hand mixer<br />

Hand mixer with adjustable length for mixing of chemicals<br />

in a tank. The mixer is designed for Grundfos<br />

chemical tanks.<br />

Material: PVC.<br />

Dimensions<br />

Tank size<br />

[l]<br />

Maximum length, L<br />

[mm]<br />

Product number<br />

60 450 96417377<br />

100 600 96417378<br />

200 750 96417379<br />

300 850 96446784<br />

500 950 96417380<br />

1000 1200 96417381<br />

TM01 9599 2100<br />

TM01 2222 1498<br />

Hand mixer<br />

73


74<br />

<strong>Accessories</strong><br />

Electric mixer<br />

Electric mixers ensure homogeneous mixing of the<br />

chemical solution in the tank. Mixing is essential for<br />

dissolving powder additives or liquid additives, which<br />

are not easily dilutable.<br />

The mixer is equipped with a single or three-phase<br />

motor, an mixer shaft connected to the motor shaft and<br />

a three-blade mixing propeller.<br />

The selection of the mixer size depends on whether<br />

readily-soluble substances, or permanently poorly<br />

miscible emulsions or insoluble suspensions are to be<br />

stabilised. The latter requires higher power input and, if<br />

necessary, continuous operation instead of intermittent<br />

operation.<br />

The shaft and the propeller must be submerged into the<br />

liquid during operation. The mixer must be protected<br />

against dry-running.<br />

Mixer shaft material: PTFE-coated, stainless<br />

steel<br />

DIN W.-Nr.1.4571<br />

Propeller material: PVDF<br />

Motor insulation class: F<br />

Enclosure class: IP 55.<br />

Shaft length<br />

L [mm]<br />

500<br />

700<br />

800<br />

900<br />

1000<br />

Voltage, frequency<br />

Motor size<br />

[kW]<br />

If the mixer is mounted on a Grundfos tank, a mounting<br />

plate must be used:<br />

Speed<br />

[min -1 ]<br />

Electric mixer<br />

Product number<br />

PTFE-coated stainless steel Stainless steel<br />

1 x 230 V, 50 Hz 0.09 1420 96446789 96449515<br />

3 x 400 V, 50 Hz 0.12 1370 96446796 96449522<br />

1 x 230 V, 50 Hz 0.09 1420 96446790 96449516<br />

3 x 400 V, 50 Hz 0.12 1370 96446797 96449523<br />

1 x 230 V, 50 Hz 0.09 1420 96446791 96449517<br />

3 x 400 V, 50 Hz 0.12 1370 96446798 96449524<br />

1 x 230 V, 50 Hz<br />

0.09<br />

0.18<br />

1420<br />

1450<br />

96446792<br />

96446793<br />

96449518<br />

96449519<br />

3 x 400 V, 50 Hz<br />

0.12<br />

0.25<br />

1370<br />

1420<br />

96446800<br />

96446801<br />

96449525<br />

96449526<br />

1 x 230 V, 50 Hz<br />

0.09<br />

0.18<br />

1420<br />

1450<br />

96446794<br />

96446795<br />

96449520<br />

96449521<br />

3 x 400 V, 50 Hz<br />

0.12<br />

0.25<br />

1370<br />

1420<br />

96446802<br />

96446804<br />

96449527<br />

96449528<br />

Tank size [l] Product number<br />

60 96467256<br />

100 96467257<br />

200 96467258<br />

300 96467259<br />

500 96467330<br />

1000 96471403<br />

TM01 9790 3100


<strong>Accessories</strong><br />

Dimensions<br />

Motor size<br />

[kW]<br />

0.09<br />

0.12<br />

0.18<br />

0.25<br />

Sealing flange<br />

Dimensions [mm]<br />

A B C D E F G H<br />

140 115 95 15 9 9.5 100 195<br />

160 130 110 - 9 9.5 100 220<br />

When mixing aggressive liquids, the use of a sealing<br />

flange for protection of the motor is recommended.<br />

Product number 96446805. The sealing flange is made<br />

of polypropylene and sealed with a V-ring.<br />

Note: The sealing flange fits 0.09 and 0.12 kW mixers.<br />

Other flanges are available on request.<br />

TM01 9806 3200<br />

Electric mixer<br />

75


76<br />

<strong>Accessories</strong><br />

Wall bracket<br />

Wall bracket for easy installation of the dosing pump on<br />

a wall.<br />

Dimensions<br />

A<br />

A<br />

221<br />

133<br />

75<br />

121<br />

123.5<br />

A-A<br />

ø5<br />

Pump type Material Product number<br />

DME and DMS<br />

up to 48 l/h<br />

PPO 96441202<br />

ø3.5<br />

TM02 4360 0602<br />

TM02 4306 0402<br />

Wall bracket


<strong>Accessories</strong><br />

Water meter<br />

In-line water meter with potential-free pulse signal for<br />

use in flow-proportional dosing applications.<br />

Qn 1.5 and Qn 2.5 meters are of the multi-jet, dry dial<br />

type for cold water up to 30°C or hot water up to 90°C.<br />

Qn 15 meters and up are of the helical vane type for<br />

cold water up to 50°C or hot water up to 120°C.<br />

Max. pressure: 16 bar.<br />

If the water meter is to be connected to the pump pulse<br />

input, a control plug should be used.<br />

Product number of control plug: 96440449.<br />

Qn 1.5 to Qn 15 meters are threaded.<br />

Qn 40 to Qn 150 meters are flanged.<br />

Cable length: 3 metres<br />

Maximum load, reed contact: 30 VAC/VDC, 0.2 A.<br />

Qn<br />

[m 3 /h]<br />

Pulse rate<br />

[l/pulse]<br />

Dimensions<br />

Maximum<br />

shortperiod<br />

capacity<br />

[m 3 /h]<br />

Maximum<br />

pressure<br />

[bar]<br />

Transitional<br />

capacity with<br />

error<br />

± 2% [l/h]<br />

Minimum<br />

capacity<br />

with error<br />

± 5% [l/h]<br />

Product number<br />

Maximum water temperature<br />

Water meter<br />

30°C 50°C 90°C 120°C<br />

1.5 1 3 16 120 50 96446846 - 96446897 -<br />

2.5 2.5 5 16 200 70 96446847 - 96446898 -<br />

15 10 30 16 3000 450 - 96446848 - 96446899<br />

1.5 0.25 3 16 120 50 96482640 - 96482643 -<br />

2.5 0.25 5 16 200 70 96482641 - 96482644 -<br />

15 2.5 30 16 3000 450 96482642 - 96482645 -<br />

40 100 80 10 4000 700 - 96446849 - 96446900<br />

60 25 120 10 6000 1200 - 96446850 - 96446901<br />

150 100 300 10 12000 3000 - 96446851 - 96446902<br />

Size Meter connections Installation kit connections<br />

Meter port-to-port length<br />

[mm]<br />

Port-to-port length incl. kit<br />

[mm]<br />

Threaded connections<br />

Qn 1.5 G 3/4" Rp 1/2" 165 245<br />

Qn 2.5 G 1" Rp 3/4" 190 288<br />

Qn 15<br />

Flanged connections<br />

G 2.5" Rp 2" 300 438<br />

Qn 40 DN 80 - 225 -<br />

Qn 60 DN 100 - 250 -<br />

Qn 150 DN 150 - 300 -<br />

GR5806p<br />

77


V7164097 0305<br />

Repl.: V7 16 40 97 03 04<br />

www.grundfos.com<br />

GB<br />

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark<br />

Telephone: +45 87 50 14 00.<br />

Being responsible is our foundation<br />

Thinking ahead makes it possible<br />

Innovation is the essence<br />

Subject to alterations.