Functions<br />

Functional description, DME<br />

The electronically controlled variable-speed motor of<br />

the DME pumps provides optimum control of the stroke<br />

speed. As shown in the figure below, the duration of<br />

each suction stroke is constant while the duration of<br />

each discharge stroke varies according to the capacity<br />

set, resulting in optimum discharge flow in any operating<br />

situation.<br />

The advantages are as follows:<br />

• The pump is always operating at full stroke length,<br />

irrespective of the capacity set, for optimum accuracy,<br />

priming and suction.<br />

• A capacity range of 1:1000 (0-48 l/h) for each pump<br />

size.<br />

Capacity<br />

setting<br />

100%<br />

50%<br />

10%<br />

Discharge<br />

Discharge<br />

Discharge<br />

Functional description, DMS<br />

The electronically controlled synchronous motor of the<br />

DMS pumps offers almost the same advantages as<br />

those of DME pumps. As shown in the figure below, the<br />

suction and discharge stroke speeds are constant while<br />

the stroke frequency varies according to the capacity<br />

set. The sinusoidal movement of the diaphragm offers<br />

the following advantages:<br />

• The pump is always operating at full stroke length,<br />

irrespective of the capacity set, for optimum accuracy,<br />

priming and suction.<br />

Capacity<br />

Discharge<br />

setting<br />

100%<br />

50%<br />

10%<br />

Suction<br />

Suction<br />

Suction<br />

Suction<br />

Discharge<br />

Suction<br />

Discharge<br />

Suction<br />

DME and DMS<br />

• A capacity range of 1:800 (60-940 l/h) for each<br />

pump size.<br />

• Even and constant dosing ensuring an optimum<br />

mixing ratio at the injection point.<br />

• Significant reduction of pressure surges, preventing<br />

mechanical stress on diaphragm, tubes, connections<br />

and other dosing parts exposed to leakage<br />

and wear.<br />

• The installation is less affected by long suction and<br />

discharge lines.<br />

• Easier dosing of highly viscous and gas-containing<br />

liquids.<br />

The optimum dosing control shown below takes place<br />

in any operating mode.<br />

duration<br />

duration<br />

duration<br />

• A capacity range of 1:100 for each pump size.<br />

• Reduction of pressure surges, preventing mechanical<br />

stress on diaphragm, tubes, connections and<br />

other dosing parts exposed to leakage and wear.<br />

• The installation is less affected by long suction and<br />

discharge lines.<br />

• Easier dosing of highly viscous and gas-containing<br />

liquids.<br />

duration<br />

duration<br />

duration<br />

TM01 8944 0900<br />

TM01 8945 0900