For espresso only:<br />
Coffee is dispensed too<br />
slowly and it tastes<br />
burnt.<br />
For espresso only:<br />
The coffee lacks body<br />
and is dispensed too<br />
quickly.<br />
The mixers clog up<br />
Excessive coffee dose or ground too finely. The dose is calculated using an algorithm that<br />
counts the number revolutions of the grinder,<br />
and the doses are dispensed correctly if the<br />
grinder is adjusted with the correct grade of<br />
grinding.<br />
Check that the distance between the grinding<br />
wheels is the factory default one.<br />
Coffee dose too small, or ground too<br />
coarsely.<br />
Failed rotation of the mixer.<br />
Excessive instant product dose.<br />
Steam exhaust box clogged.<br />
Water to powder ratio not correct.<br />
NW Global Vending – TECHNICAL MANUAL<br />
This document was produced by MARK AC for the exclusive use of the technical personnel in the after-sales <strong>service</strong>.<br />
. No part of this document may be divulged to a third party or reproduced partially or entirely without the prior permission of NW GLOBAL VENDING<br />
. All rights reserved.<br />
The dose is calculated using an algorithm that<br />
counts the number revolutions of the grinder,<br />
and the doses are dispensed correctly if the<br />
grinder is adjusted with the correct grade of<br />
grinding.<br />
The dispensing time must remain constant.<br />
Check that the distance between the grinding<br />
wheels is the factory default one; with use the<br />
grinding wheels are subject to wear and it will<br />
be necessary to reset the correct measurement<br />
periodically.<br />
Check for the motor overheat protection trigger,<br />
if necessary check the cause of such trigger.<br />
Empty the powder removal box, adjust and<br />
check the correct water to powder ratio.<br />
Check the logic of the cycles.<br />
Check the activation of relay K3.<br />