Hydraulics Pr<strong>of</strong>. B.S. Thandaveswara<br />

They are held by vertical rigid rods fixed with the axis <strong>of</strong> the current meters parallel to<br />

the tank wall.<br />

Threshold Velocity<br />

The current meter is towed at very low speed range from 0.02 ms -1 in steps <strong>of</strong> 0.010 ms -<br />

1 till the current meter begins rotating after overcoming the inertia and the corresponding<br />

velocity is taken as threshold velocity.<br />

Rating Run<br />

The rating <strong>of</strong> the current meter is carried out in still water. The rating run length at<br />

constant velocities are<br />

(i) 10 m for velocities less than 0.60 ms -1 and<br />

(ii) 20 m to 30 m for velocities above 0.60 ms -1 .<br />

The carriage runs are made in the forward direction at selected velocities. The velocity<br />

<strong>of</strong> the carriage is changed from 0.20 to 3.60 ms -1 in steps <strong>of</strong> 0.2 ms -1 initially and then<br />

0.3 ms -1 so as to obtain about 14 readings. The accuracy <strong>of</strong> rating is <strong>of</strong> the order <strong>of</strong><br />

±0.5%.<br />

Evaluation <strong>of</strong> the Data<br />

From the readings, the actual value <strong>of</strong> the velocity <strong>of</strong> the carriage, V (ms -1 ) and the<br />

corresponding revolution per second <strong>of</strong> the cup/propeller 'N' are calculated and plotted.<br />

One or more straight lines are manually fitted through the data points as necessitated<br />

and the corresponding equation(s) are determined. The graphical plot will also be<br />

provided with the report for reference.<br />

Tabulation<br />

Using the rating equation(s) determined as above, the current meter rating tables are<br />

prepared on a digital computer. Special remarks if any are noted in the rating chart<br />

(Table 1).<br />