powder coated tubing to meet the requirements <strong>of</strong> FMVSS 210. Installation <strong>of</strong> the seats shall meet the<br />

requirements <strong>of</strong> FMVSS 207.Seats covering shall be Level 4 or approved equal, 32 ounce anti-microbial<br />

fire block type vinyl upholstery, with heat sealed vertical seams. Foam shall be contoured, dense, transit<br />

grade polyurethane with a minimum thickness <strong>of</strong> one and half (1 ½) inches. All fixed forward facing seats<br />

shall provide at least 17 inches <strong>of</strong> seating support. Top <strong>of</strong> uncompressed seat cushion to floor shall be<br />

between 19 inches and 21. Color shall be selected after contract award.<br />

23.4 Seat cover upholstery materials and padding shall meet or exceed the applicable flammability and<br />

smoke emission performance requirements specified in FMVSS 302.<br />

23.5 Any flip seat requested as an option shall be equipped with a spring-loaded automatic latching<br />

device to prevent the bottom seat cushion from returning to the horizontal position. The locking device<br />

shall be constructed to be manually released to avoid accidental return during use. The width <strong>of</strong> the flip<br />

seat in the stored position shall not exceed eleven and one half (11 ½) inches. Additionally, flip seats<br />

shall be upholstered with the same quality and color material as the standard passenger seats. The<br />

design <strong>of</strong> the flip seat shall complement the standard passenger seats and be from the same<br />

manufacturer or approved equal. The seat shall also lock in the seated position. As an option, a nonlocking<br />

(in the seated position) flip seat shall be <strong>of</strong>fered.<br />

23.6 Each seat position shall be equipped with a self-retracting passenger restraint system, which meets<br />

current FMVSS requirements, intended to hold passengers in a secure seated position during normal<br />

operations. Seat belts shall be anchored through the floor structure, independent <strong>of</strong> the seat, or bolted<br />

to the seat frame assembly. Each restraint belt and installation shall meet all applicable FMVSS<br />

standards including 208, 209 and 210. The installation <strong>of</strong> the seat belts shall have no twisting, binding or<br />

bunching <strong>of</strong> the seat belt web material. The retractor shall be mounted to the seat frame. Six (6) seat<br />

belt extensions shall be provided with each bus.<br />

23.7 All wall-mounted belt securement points must be mounted into a reinforced sidewall. Wall<br />

mounting into the standard sidewall is unacceptable. The belt securement system shall feature an<br />

integrated restraint tie-down system securing belts not in use.<br />

23.8 The forward most row <strong>of</strong> seats on both sides <strong>of</strong> the bus shall be equipped with DOT/FMVSS<br />

approved child seat anchors in each seating positions.<br />

23.9 Seat Dimensions<br />

24 WIRING<br />

1. Seat width per person: 17.5 inches minimum<br />

2. Seat depth: 17 inches minimum<br />

3. Seat back: 24 inches minimum<br />

4. Seat back angle 10 to 15 degrees<br />

5. Hip to knee room: 27 inches nominal (maximum available)<br />

6. Aisle width: 18* inches minimum (maximum available)<br />

* To be measured at seated passenger hip height.<br />

24.1 Original manufacturer’s vehicle wiring shall remain unchanged to the greatest extent practicable<br />

consistent with the requirements <strong>of</strong> these specifications. All add-on electrical components controlling<br />

the power to the bus body electrical circuits shall be located in a separate electrical junction box. The<br />

junction box shall be easily accessible through a hinged lockable door. The junction box shall be suitably<br />

sized to allow for ease <strong>of</strong> maintenance, repair and ten (10) percent additional space for the installation<br />

<strong>of</strong> future electrical components. The junction box shall be located within accessible reach <strong>of</strong> the driver.<br />

All body harnesses shall join on a terminal strip made <strong>of</strong> a high strength dielectric material. All circuits<br />

PAGE 21 OF 40