CHILLER<br />
CHILLER<br />
(includes PUMP<br />
and RESEVOIR)<br />
G128_0422GCA<br />
G128_0422GC<br />
Components<br />
Caution<br />
De-energize the CHILLER before removing any HOSES.<br />
The CHILLER SYSTEM provides a constant thermal load to work against the HEATERS. This increases the<br />
stability of the developer solutions. The CHILLER cools the water to 24°C (75°F) and recirculates this water through<br />
metal CHILLER TUBES in the bottom of the DEVELOPER TANKS. This is a closed-loop system with a small<br />
reservoir. Any time the CHILLER energizes, water PUMPS through the system. The PUMP drains the CHILLER in<br />
a very short time. When reassembling the CHILLER SYSTEM during servicing, check that the RESERVOIR is<br />
filled correctly.<br />
The CHILLER delivers 25°C (77°F) water to cool the 4 developers in the PROCESSOR. The circulation of the<br />
chilled water helps the TEMPERATURE CONTROLLER maintain the setpoint temperatures of the processing<br />
solutions.<br />