CHILLER<br />

CHILLER<br />

(includes PUMP<br />

and RESEVOIR)<br />

G128_0422GCA<br />

G128_0422GC<br />

Components<br />

Caution<br />

De-energize the CHILLER before removing any HOSES.<br />

The CHILLER SYSTEM provides a constant thermal load to work against the HEATERS. This increases the<br />

stability of the developer solutions. The CHILLER cools the water to 24°C (75°F) and recirculates this water through<br />

metal CHILLER TUBES in the bottom of the DEVELOPER TANKS. This is a closed-loop system with a small<br />

reservoir. Any time the CHILLER energizes, water PUMPS through the system. The PUMP drains the CHILLER in<br />

a very short time. When reassembling the CHILLER SYSTEM during servicing, check that the RESERVOIR is<br />

filled correctly.<br />

The CHILLER delivers 25°C (77°F) water to cool the 4 developers in the PROCESSOR. The circulation of the<br />

chilled water helps the TEMPERATURE CONTROLLER maintain the setpoint temperatures of the processing<br />

solutions.<br />

TG2044-1 – 06APR99 11