Section 12: Sequence of Operation<br />

Energizing the PROCESSOR<br />

Sequence of Operation<br />

The following actions occur when the PROCESSOR energizes:<br />

1. The HOST COMPUTER energizes and initiates the main control program which controls all the<br />

functions and the maintenance of the PROCESSOR.<br />

2. The main computer program checks the status of:<br />

• HOST<br />

• PROCESSOR<br />

• REPLENISHER RACK<br />

• TEMPERATURE CONTROLLER<br />

• REEXPOSURE PRINTERS<br />

• COMPUTERS<br />

3. The PROCESSOR COMPUTER energizes and initiates the PROCESSOR program.<br />

4. The REEXPOSURE PRINTERS de-energizes and waits for commands from the main computer<br />

program.<br />

5. The processor program sets the CHILLER BYPASS SOLENOID VALVE to the bypass position<br />

to keep the chilled water out of the PROCESSOR.<br />

6. The following components in the PROCESSOR de-energize:<br />

• TEMPERATURE CONTROLLER<br />

• REEXPOSURE PRINTERS<br />

7. The REPLENISHER RACK COMPUTER energizes and initiates the replenisher program.<br />

8. The REPLENISHER program stops the flow of water from the INTELLIFAUCET to the WASH<br />

TANKS in the PROCESSOR.<br />

9. The REPLENISHER program de-energizes all PUMPS.<br />

TG2044-1 – 06APR99 37