1.6.5 Replacing an Ignitor Assembly<br />

DANGER<br />

Drain the frypot or remove the h<strong>and</strong>le from the drain valve before proceeding further.<br />

1. Disconnect the fryer from the electrical supply.<br />

2. Disconnect the flame sensor wire by carefully pulling its push-on terminal from the terminal<br />

strip on the ignitor. Disconnect the gas enrichment tube at the ignitor-end compression fitting.<br />

Disconnect the ignition cable from the ignitor by grasping its boot <strong>and</strong> gently pulling toward<br />

you.<br />

3. Remove the sheet metal screws securing the ignitor to the mounting plate <strong>and</strong> pull the ignitor<br />

from the fryer.<br />

4. Reverse the procedure to install the replacement ignitor.<br />

1.6.6 Replacing or Cleaning a Combustion Air Blower<br />

1. Disconnect the blower wiring harness, remove the blower assembly mounting nuts, <strong>and</strong> remove<br />

the blower assembly from the fryer. If cleaning the motor, continue with Step 2; otherwise,<br />

install the replacement blower, reconnect the wiring harness, <strong>and</strong> then go to Step 6.<br />

Wiring connection Blower assembly<br />

mounting nuts<br />

1-10<br />

Flame Sensor Wire<br />

<strong>Gas</strong> Enrichment Tube<br />

Ignition Cable