1.11 Wiring Diagrams<br />
1.11.1 <strong>Pro</strong> <strong>H50</strong>/<strong>55</strong>-<strong>Series</strong> Fryer, Multi-vat<br />
SENSE 2<br />
ALARM(GND)<br />
VALVE(GND)<br />
24VAC(GND)<br />
24VAC<br />
SPARK 2<br />
SENSE 1<br />
ALARM<br />
VALVE<br />
GND<br />
(BURNER)<br />
SPARK 1<br />
SOUND DEVICE<br />
SOUND<br />
1<br />
GND 2<br />
3<br />
J2<br />
12V<br />
GND<br />
AIR<br />
J1<br />
J3<br />
K1<br />
K4<br />
GND GV LEFT RIGHT<br />
GV<br />
V2D<br />
PWR<br />
BL<br />
RELAY<br />
BL GND<br />
RELAY V1D<br />
AD<br />
AS LEFT DV<br />
PWR<br />
HEAT &<br />
V2S BLOWER<br />
RELAY<br />
GND<br />
K2<br />
PWR<br />
FV OR<br />
ALR<br />
24V RIGHT DV<br />
HEAT & V1S<br />
BLOWER PWR<br />
RELAY GND<br />
K3<br />
COMPUTER GROUND<br />
DETAIL<br />
A A<br />
SOUND DEVICE LEFT IGNITOR RIGHT IGNITOR<br />
OIL RETURN HEATER FRONT<br />
1 2<br />
1<br />
GND<br />
3<br />
J2<br />
12V<br />
GND<br />
AIR<br />
J1<br />
J3<br />
GV<br />
2<br />
SOUND<br />
K1<br />
K4<br />
GND GV LEFT<br />
V2D BL<br />
PWR RELAY<br />
RIGHT<br />
BL GND<br />
RELAY V1D<br />
AD<br />
AS LEFT DV<br />
PWR<br />
HEAT &<br />
V2S BLOWER<br />
RELAY<br />
GND<br />
K2<br />
PWR<br />
FV OR<br />
ALR<br />
24V RIGHT DV<br />
HEAT & V1S<br />
BLOWER PWR<br />
RELAY GND<br />
K3<br />
LEFT IGNITOR<br />
TO J3 PIN12<br />
WHITE<br />
BLOWER<br />
COMPUTER OR CONTROLLER<br />
COMPUTER GROUND<br />
DETAIL<br />
A A<br />
RIGHT IGNITOR<br />
TO C2 PIN1<br />
TO C2 PIN12<br />
TO C2 PIN3<br />
GV<br />
GND<br />
V1D<br />
PWR<br />
ALR<br />
V1S<br />
PWR<br />
8051315C<br />
T1 T2<br />
FUSE<br />
TO J2<br />
LINE VOLTAGE (L1)<br />
LINE VOLTAGE(COM)<br />
1-41<br />
SENSE 2<br />
ALARM(GND) ALARM<br />
VALVE(GND) VALVE<br />
24VAC(GND)<br />
24VAC<br />
SPARK 2<br />
SENSE 1<br />
GND<br />
(BURNER)<br />
SPARK 1<br />
FULL VAT<br />
SENSE 2<br />
ALARM(GND)<br />
VALVE(GND)<br />
24VAC(GND)<br />
24VAC<br />
SPARK 2<br />
SENSE 1<br />
ALARM<br />
VALVE<br />
GND<br />
(BURNER)<br />
SPARK 1<br />
DUAL VAT<br />
DETAIL A-A<br />
ALARM(GND)<br />
VALVE(GND)<br />
24VAC(GND)<br />
24VAC<br />
INSET<br />
HONG KONG<br />
UNITS ONLY<br />
TO J3 PIN9<br />
TO J3 PIN6<br />
TO J3 PIN2<br />
BLK<br />
RED<br />
WHT<br />
BLK<br />
BLK<br />
BLK<br />
NC<br />
NO COM<br />
FOR UNITS WITH NO<br />
SAFETY DRAIN SWITCH<br />
ADD IN-LINE SPLICE<br />
BLK MV<br />
FULL VAT<br />
GAS<br />
VALVE<br />
Refer to "PRINCIPAL WIRING CONNECTIONS"<br />
on Page 1-41 for detail of connection points<br />
J1, J2, J3, C2, C3, <strong>and</strong> C5.<br />
MV<br />
DUAL VAT<br />
TEMP<br />
PROBE<br />
TEMP<br />
PROBE<br />
HIGH<br />
LIMIT<br />
SAFETY<br />
DRAIN<br />
SWITCH<br />
TO J1 PIN2<br />
WHT<br />
TO J1 PIN8<br />
TO J1 PIN9<br />
RED<br />
HIGH<br />
LIMIT BLK<br />
GAS<br />
VALVE<br />
SAFETY<br />
DRAIN<br />
SWITCH<br />
NC<br />
NO<br />
COM<br />
FOR UNITS WITH NO<br />
SAFETY DRAIN SWITCH<br />
ADD IN-LINE SPLICE<br />
MV<br />
MV<br />
BLK<br />
BLK<br />
BLK<br />
BLK