8. Remove the washers <strong>and</strong> tubular spacers from the mounting studs, then pull the inner covers<br />
straight out toward you until clear of the mounting studs.<br />
9. Grasp the burner firmly <strong>and</strong> pull it toward you until it clears the burner channels, taking care not<br />
to damage the ceramic tiles in the process.<br />
10. Clean all debris from the burner channels <strong>and</strong> combustion area.<br />
11. Inspect the upper <strong>and</strong> lower burner rails for cracked or burned out welds.<br />
a. If the welds in the lower rail are cracked or burned out, the frypot must be replaced. Refer to<br />
Section 1.6.10 for instructions.<br />
b. If the welds in the upper rail are cracked or burned out, the upper rail must be replaced.<br />
Refer to Section 1.6.11 for instructions.<br />
12. Place a new insulating strip along the top, rear, <strong>and</strong> bottom edge of the burner <strong>and</strong> carefully slide<br />
it straight into the rails. NOTE: Use P/N 826-0931 for full-vat frypots <strong>and</strong> P/N 826-0932 for<br />
dual-vat frypots.<br />
13. Reverse steps 1 through 9 to reassemble the components.<br />
14. Fill the frypot with oil. Turn the fryer on, turn off or bypass the melt cycle, <strong>and</strong> operate the unit<br />
for at least 10 minutes.<br />
15. Visually examine the burner flame. The color <strong>and</strong> intensity on both sides should be the same.<br />
16. Use an inspection mirror to check for leaks in areas that cannot be directly observed.<br />
17. If a leak is detected, tighten all the lower insulation retainer nuts, allow the frypot to run for five<br />
additional minutes, <strong>and</strong> repeat steps 15 <strong>and</strong> 16.<br />
18. If the leak persists, use a rubber hammer <strong>and</strong> a small block of wood to tap the corners of the<br />
lower combustion chamber insulation retainers. Repeat steps 15 through 17. Repeat this step<br />
until no leakage is detected.<br />
1.6.9 Replacing the Filter Motor, Filter Pump, or Filter Pump Solenoid Valve<br />
1. Disconnect the unit from the electrical power supply.<br />
2. Remove the filter pan from the unit <strong>and</strong> drain the frypots into a Shortening Disposal Unit (SDU)<br />
or other appropriate metal container.<br />
DANGER<br />
DO NOT attempt to drain more than one full frypot or two split frypots into the SDU<br />
at one time.<br />
1-15