OPERATION PROCEDURE<br />

9. REMOVING THE HEAT EXCHANGER AND LEV<br />

(1) Remove the front panel (Refer to procedure 2) and the<br />

corner panel at right lower side.<br />

(2) Remove the electrical box (Refer to procedure 4) and the<br />

nozzle assembly (Refer to procedure 5).<br />

(3) Remove the motor band.<br />

(4) Remove the pipe thermistors (Refer to procedure 8).<br />

(5) Disconnect the connector (CN60) on the indoor controller<br />

board and the connector for ground wire. (See Photo 5)<br />

(6) Remove the screws fixing the left side of the heat<br />

exchanger. (See Photo 10)<br />

(7) Remove the heat exchanger with LEV.<br />

10. REMOVING THE ROOM TEMPERATURE THERMISTOR<br />

(1) Remove the front panel (Refer to procedure 2).<br />

(2) Remove the electrical box cover.<br />

(3) Remove the room temperature thermistor.<br />

(4) Disconnect the connector (CN20) on the indoor controller<br />

board.<br />

NOTE: When room temp. thermistor is replaced, be sure<br />

to use service parts No. R01 N20 202.<br />

Photo 16<br />

Screw (top cover)<br />

Water cover<br />

Nozzle assembly<br />

OCH515<br />

Screw (side cover)<br />

Switch holder<br />

Electrical box<br />

cover (top)<br />

Electrical box<br />

cover (side)<br />

Room temp.<br />

thermistor<br />

(TH21)<br />

Thermistor<br />

holder<br />

Screw<br />

(side cover)<br />

Holder of wireless<br />

controller board<br />

25<br />

Photo 13<br />

Screw (top cover)<br />

Water cover<br />

Nozzle assembly<br />

Photo 14<br />

Heat<br />

exchanger<br />

Photo 15<br />

Terminal<br />

block (TB2)<br />

Terminal<br />

block (TB5)<br />

Terminal<br />

block (TB15)<br />

PHOTOS<br />

Screw (side cover)<br />

Switch holder<br />

Fixture<br />

(right)<br />

Ground wire<br />

Electrical box<br />

cover (top)<br />

LEV<br />

Indoor controller board (I.B)<br />

Room temp. thermistor (TH21)<br />

Electrical box<br />

cover (side)<br />

Room temp.<br />

thermistor<br />

(TH21)<br />

Thermistor<br />

holder<br />

Screw<br />

(side cover)<br />

Holder of wireless<br />

controller board<br />

Fixture<br />

(right)