3<br />
OUTLINES AND DIMENSIONS<br />
PKFY-P08NHMU-E2<br />
PKFY-P12NHMU-E2<br />
PKFY-P15NHMU-E2<br />
PKFY-P18NHMU-E2<br />
Sleeve<br />
(purchased locally)<br />
7/16(12.5)<br />
OCH515<br />
2-1/2~3-1/8<br />
(65~80)<br />
A<br />
1-11/16(43)<br />
D<br />
Through hole<br />
2-1/2~3-1/8<br />
(65~80)<br />
Knockout hole for piping<br />
2-3/16(56)<br />
Left side<br />
Knockout hole<br />
for left piping<br />
C<br />
1-3/4(46)<br />
2-3/16(56)<br />
3/16(6)<br />
77-3/16(5.1)<br />
Tapping<br />
screw hole<br />
0<br />
5/8(16)<br />
1-1/16(28.5)<br />
1-9/16(41)<br />
3-1/16(78.5)<br />
3-9/16(91)<br />
4-1/16(103.5)<br />
4-9/16(116)<br />
6-1/2(166)<br />
7(178.5)<br />
8(203.5)<br />
9-1/8(232.5)<br />
9-15/16(253.5)<br />
1-11/16(43)<br />
Wall hole for<br />
left rear piping<br />
2-11/16(69)<br />
7-3/4(197)<br />
Knockout hole<br />
for lower piping<br />
11-9/16(295)<br />
5/16(8)<br />
2-3/16(56)<br />
3/16(6)<br />
2-1/8<br />
(55)<br />
4-5/16(9) Bolt hole<br />
14-5/8(372.3)<br />
14(356.3)<br />
12-7/8(327.5)<br />
11-7/16(291.5)<br />
10-3/8(265)<br />
8-13/16(225)<br />
7-13/16(200)<br />
17-5/8(449)<br />
1-3/4(46)<br />
2-5/16(60)<br />
C<br />
15-1/2(394)<br />
Vane(auto)<br />
10-15/16(278.3)<br />
9-5/16(238)<br />
8-3/8(213)<br />
6-13/16(174)<br />
D<br />
1-11/16(43)<br />
1-11/16(43)<br />
15-3/16(387) 7-1/2(192)<br />
Louver(manual)<br />
2-5/16(59)<br />
B<br />
Front side(Grille open)<br />
4-7/8(125)<br />
27-1/16(688)<br />
17-15/16(457)Gas pipe<br />
21-3/16(539)Liquid pipe<br />
7<br />
2-3/4(70)<br />
23-9/16(599)<br />
35-5/16(898)<br />
0<br />
9/16(15)<br />
0<br />
9/16(15)<br />
0<br />
2-1/4(58)<br />
Knockout hole for<br />
rear piping<br />
2-3/4×12-3/16(70×310)<br />
2-3/4(70)<br />
5/32(3.8)<br />
4-7/8(125)<br />
Center measurement hole 3/32(2.5)<br />
Mount board<br />
4-1/2(115)<br />
5-1/2(140)<br />
6-9/16(167)<br />
7-1/16(180.3)<br />
7-9/16(193.5)<br />
7-13/16(200)<br />
8-13/16(225)<br />
9-5/16(238)<br />
10-3/8(265)<br />
11-7/16(291.5)<br />
12-7/8(237.5)<br />
14(356.3)<br />
14-5/8(372.3)<br />
11-1/16(281)<br />
6-5/8(169)<br />
6-3/16(158)<br />
24(610)Drain hose 7-3/16(184)<br />
Under side<br />
24-1/16(612)<br />
Min.1/4(7)<br />
Knockout hole<br />
for lower piping<br />
Operation lamp<br />
Required space(Indoor unit)<br />
Min.1-31/32(50)<br />
B<br />
Top side<br />
Front side<br />
6-1/16(155)<br />
Wall hole for<br />
right rear piping<br />
Refrigerart<br />
Piping<br />
Liquid pipe<br />
Gas pipe<br />
Drain hose<br />
Indoor unit outline<br />
17-5/8(449)<br />
Min.8-5/8<br />
(220)<br />
Terminal block for power supply<br />
Terminal block for transmission<br />
Terminal block for<br />
MA-remote controller<br />
Emergency operation switch<br />
(cooling/heating)<br />
DEFROST/STAND BY lamp<br />
Receiver<br />
13/16(21.8)<br />
0<br />
3/4(20)<br />
1-1/4(32.7)<br />
2-1/16(53.5)<br />
2-9/16(66)<br />
5(128.5)<br />
6(153.5)<br />
9-1/16(231.5)<br />
10-3/4(273.2)<br />
Knockout hole<br />
for right piping<br />
Air inlet<br />
Air inlet<br />
Right side<br />
Min.5-7/8(150)<br />
Mount board<br />
9-3/4(249)<br />
Air outlet<br />
Unit : inch (mm)<br />
A<br />
1/4F (6.35)<br />
1/2F (12.7)<br />
5/8 (16) I.D<br />
3/16(5)<br />
Min.1-31/32(50)<br />
Min.9-13/16(250)