Frequently Asked Questions<br />

Q. Can the stove be flued directly off the back?<br />

A. Yes, using the standard low level horizontal kit.<br />

Q. Can I use a bend directly off the top of the stove?<br />

A. No, the stove adapter is only designed to fit the telescopic starter length and straight lengths, bends will not<br />

seal to the flue outlet.<br />

Q. Can I fit the stove in the corner of a room?<br />

A. Yes, there is no problem in doing this using the top to horizontal flue kit, but it must be remembered that if<br />

the corner is also the corner of the property that the termination must be 600mm from any corner. See diagram<br />

page 5.<br />

Q. Can the vertical flue be passed through a combustible roof, such as a polycarbonate roof in a conservatory?<br />

A. Yes, as long as allowances are made for the type of roofing material and suitable insulation is provided. See<br />

the section on flueing through a combustible roof.<br />

Q. Can the stove be fitted into a bedroom?<br />

A. Yes, the stoves are room sealed and below 14kW input.<br />

Q. Can I cut the lengths of flue pipe?<br />

A. Yes, however the differential between the inner and outer length has to be maintained. It would be preferable<br />

to use an adjustable length<br />

Q. Does the flue terminal need to be guarded?<br />

A. If the flue terminal is to be sited less than two meters above level ground,<br />

a balcony or a flat roof where people have access, a guard must be fitted. Local<br />

by-laws may also require a further minimum height where the terminal is sited<br />

adjoining a public footpath.<br />

Q. If I have a high level horizontal kit can I then terminate it vertically?<br />

A. Yes, there is a vertical terminal with a crimped end which will fit to the<br />

flue system.<br />

Q. Do I need an air brick or other ventilation for supplying free air to the<br />

stove?<br />

A. No, the stove is room sealed and does not have any requirement for free<br />

air.<br />

Q. Does it matter how far out of the wall the terminal is fitted on a horizontal flue kit?<br />

A. Yes, there should be 12mm of flue pipe visible before the start of the flue terminal. Any greater length can<br />

upset the balanced flues operation.<br />

Q. What colours are the flue pipe available in?<br />

A. The flue pipe is supplied in one colour, a matt grey finish, which closely matches the cast finished stoves and<br />

complements the enamel finished stove. It is possible to change the colour using heat resistant paint.<br />

Q. To what wind speed are the terminals tested to?<br />

A. The maximum wind used is 12.5 m/s with 10% error. (28mph).<br />

Vertical terminal with<br />

crimped end<br />

Size Part No:<br />

150mm MS91047<br />

180MM MS91048<br />

Q. What is the maximum length the flue can travel horizontaly from the rear outlet of the stove?<br />

A. The standard low level horizontal flue kit gives a maximum extension of 440mm. No additional lengths or<br />

bends should be fitted.<br />

© EUROHEAT DISTRIBUTORS (H.B.S) LTD. 17<br />

Technical <strong>Guide</strong> IN1105 Ed 5 May 2009