Vacuum impurities away from the uncovered<br />

inner area and the side openings.<br />

Re-assemble the stove in reverse order.<br />

Cleaning the Flue Main Duct<br />

The flue main duct should be cleaned at least twice a year or after approx. 700 kg pellets.<br />

The flue main duct is located in the lower section of the combustion chamber.<br />

After removing the front panels as described in the section<br />

“Disassembly of Casing Panels”.<br />

Open the combustion chamber door.<br />

Remove the cleaning cover by opening the two outer<br />

hexagonal head screws.<br />

Vacuum away any residues from the main flue duct.<br />

Re-assemble the parts in reverse order.<br />

Observe the condition of any seals and replace if worn or<br />

damaged. Failure to do so may allow air into the stove and<br />

this may lead to incomplete combustion and the possibility<br />

of the pellets piling up in the chute which is a burnback<br />

hazard.<br />

28<br />