Vacuum impurities away from the uncovered<br />
inner area and the side openings.<br />
Re-assemble the stove in reverse order.<br />
Cleaning the Flue Main Duct<br />
The flue main duct should be cleaned at least twice a year or after approx. 700 kg pellets.<br />
The flue main duct is located in the lower section of the combustion chamber.<br />
After removing the front panels as described in the section<br />
“Disassembly of Casing Panels”.<br />
Open the combustion chamber door.<br />
Remove the cleaning cover by opening the two outer<br />
hexagonal head screws.<br />
Vacuum away any residues from the main flue duct.<br />
Re-assemble the parts in reverse order.<br />
Observe the condition of any seals and replace if worn or<br />
damaged. Failure to do so may allow air into the stove and<br />
this may lead to incomplete combustion and the possibility<br />
of the pellets piling up in the chute which is a burnback<br />
hazard.<br />
28<br />
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2011 <strong>Instruct</strong>ions Part Number IN1228 Ed 1