Physical data<br />

50PZ 015 025 030 031 040 045 055 065 075<br />

Nominal cooling capacity* kW 13.42 21.81 28.50 27.70 34.36 43.60 52.51 61.94 72.58<br />

Nominal heating capacity** kW 15.76 25.02 30.58 30.20 39.15 50.18 57.43 66.60 83.06<br />

Weight kg<br />

50PZ 238 400 412 427 638 864 919 968 1058<br />

40PZ 78 140 150 150 230 297 317 335 365<br />

38PZ 160 260 262 277 408 567 602 633 693<br />

Compressor (R-407C) Hermetic reciprocating Scroll<br />

Indoor/outdoor coil (40PZ/38PZ) Copper tubes, pretreated aluminium fins<br />

Indoor coil fan (40PZ) Double inlet centrifugal type<br />

Quantity 1 2 2 2 2 2 2 2 2<br />

Nominal air flow l/s 960 1490 1690 1690 2190 2640 2910 3140 3530<br />

Outdoor coil fan (38PZ) Double inlet centrifugal type<br />

Quantity 1 2 2 2 2 2 2 2 2<br />

Nominal air flow l/s 1470 3020 2780 2780 3610 4580 5080 6030 6890<br />

* Based on an outdoor air temperature of 35°C db and an indoor air temperature of 19°C wb.<br />

** Based on an outdoor air temperature of 6°C wb and an indoor air temperature of 20°C db.<br />

Electrical data<br />

50PZ (40PZ/38PZ) 015 025 030 031 040 045 055 065 075<br />

Nominal voltage* V 400 400 400 400 400 400 400 400 400<br />

Nominal power input kW<br />

Cooling** 7.2 11.2 13.6 14.6 18.1 21.6 25.4 30.2 38.5<br />

Heating*** 6.6 11.1 12.4 12.7 17.5 20.8 23.7 27.1 34.3<br />

Nominal current drawn A<br />

Cooling** 13.7 19.2 22.2 26.6 31.8 38.2 42.4 50.9 68.6<br />

Heating*** 13.0 19.2 20.7 24.0 30.2 36.8 40.9 47.4 63.5<br />

Starting current A 80.0 106.3 133.3 95.3 134.0 156.7 187.8 219.0 256.0<br />

* All units are built for 3-phase, 50 Hz supply.<br />

** Based on an outdoor air dry bulb temperature of 35°C and an indoor air wet bulb temperature of 19°C.<br />

*** Based on an outdoor air temperature of 6°C wb and an indoor air temperature of 21°C db.<br />

Dimensions, mm<br />

50PZ A B C<br />

015 910 850 1688<br />

025 1350 883 1890<br />

030, 031 1350 883 1940<br />

040 1600 993 2095<br />

045, 055 2126 1154 2158<br />

065, 075 2526 1154 2158<br />

38PZ A B C<br />

015 910 785 1180<br />

025 1350 809 1280<br />

030, 031 1350 809 1280<br />

040 1600 919 1435<br />

045, 055 2126 1080 1498<br />

065, 075 2526 1080 1498<br />

40PZ A B C<br />

015 910 850 588<br />

025 1350 883 690<br />

030, 031 1350 883 740<br />

040 1600 993 740<br />

045, 055 2126 1154 750<br />

065, 075 2526 1154 750<br />

50PZ<br />

A<br />

B<br />

C<br />

131<br />

Operating limits<br />

50PZ (40PZ/38PZ)<br />

Cooling Heating<br />

Zone Dry bulb Wet bulb Dry bulb Wet bulb<br />

Indoor air temperature °C<br />

Maximum 35 21 27 -<br />

Minimum 19 14 - -<br />

Outdoor air temperature °C<br />

Maximum 46 - 24 18<br />

Minimum 19* - -15 -<br />

* With optional head pressure control, the unit will operate at temperatures below 19°C.<br />

40PZ<br />

38PZ<br />

C<br />

Clearances required<br />

A<br />

A B<br />

C<br />

B