141<br />

Index<br />

Type Range Refrigerant Cooling capacity, Heating capacity, Page<br />

Water-cooled chillers<br />

kW<br />

kW<br />

With screw compressors 30XW brine unit R-134a 298-705 - 142<br />

With centrifugal compressors<br />

Absorption chillers<br />

Single-effect<br />

19XR/XRV R-134a 1000-5300 - 144<br />

Steam-fired absorption chillers 16TJ 352-2461 - 146<br />

Hot water-fired absorption chillers<br />

Double-effect<br />

16LJ 264-1846 - 148<br />

Direct-fired absorption chillers/heaters 16DJ 352-5274 268-4026 150<br />

Steam-fired absorption chillers 16NK 345-4652 - 152<br />

Application of the new EN14511 : 2011 chiller and heat pump performance standard:<br />

Chiller and heat pump performances are calculated in accordance with the EN14511 : 2011 calculation standard and certified by Eurovent.<br />

The latest version of EN14511 was ratified on July 19th, 2011. It uses a different method to take into account the contribution of water pumps, or heat exchanger pressure drops in the unit performances. The efficiency of<br />

the pump is no longer a default value, but a function of the required hydraulic power. In January 2012, the Eurovent Certification Company decided that this method is more realistic and it is fully applied starting<br />

from the 2012 certification campaign. The performances declared based on the new version of the standard were published on the ECC website www.eurovent-certification.com at the end of March 2012.<br />

IMPORTANT: Only 2012 performances rated according the new EN14511 : 2011, taking in account water pump and heat exchanger pressure drop are certified by Eurovent. For units declared before 2012, the<br />

previous gross EER and COP values without pump correction (for units with integral pump - measured with the pump not running) and the corresponding energy classes are available on ECC website.<br />

Application rating conditions<br />

Air conditioning applications (AC) Medium brine applications (MB)<br />

Air-cooled cooling Evaporator EWT/LWT 12°C/7°C<br />

Evaporator EWT/LWT 0°C/-5°C<br />

OAT 35°C<br />

OAT 35°C<br />

Water-cooled cooling Evaporator EWT/LWT 12°C/7°C<br />

Evaporator EWT/LWT 0°C/-5°C<br />

Condenser EWT/LWT 30°C/35°C<br />

Condenser EWT/LWT 30°C/35°C<br />

(1) Gross adjusted performances, not taking into account the water pump and heat exchanger pressure drops, are not certified by Eurovent for 2012, but used for the 2011 gross declaration and given as a<br />

reference for comparison.<br />

Legend<br />

EWT Entering water temperature<br />

LWT Leaving water temperature<br />

OAT Outdoor air temperature