Type Range Refrigerant Cooling capacity, kW Page<br />
Air-cooled units, axial fan<br />
With scroll or rotary compressors 30RB 008-015 R-410A 8-14 32<br />
30AWH R-410A 3-16 34<br />
30RB 017-033 R-410A 16-33 36<br />
30RBY 017-033 R-410A 16-32 38<br />
30RBS 039-160 “A” R-410A 39-157 40<br />
30RBSY 039-160 “A” R-410A 38-154 42<br />
30RB 162-802 R-410A 162-774 44<br />
With screw compressors 30XAS “A” R-134a 232-486 46<br />
30XA “A” R-134a 267-1682 48<br />
Water-cooled/condenserless units<br />
With scroll compressors 30WG/30WGA R-410A (30WG) 23-95 50<br />
30RW/30RWA R-407C 109-315 52<br />
With screw compressors 30HXC R-134a 287-1302 54<br />
30XW R-134a 273-1756 56<br />
30XW-V R-134a 587-1741 58<br />
23XRV R-134a 970-1880 60<br />
Air-cooled condensers<br />
With axial fan 09SO R-404A 13-353 62<br />
09TE R-404A 102-1092 64<br />
09AL R-404A 106-1602 66<br />
Fluid coolers<br />
With axial fan 09FCSO 11-327 62<br />
09FCTE 90-1008 64<br />
09FCAL 89-1498 66<br />
Application of the new EN14511 : 2011 chiller and heat pump performance standard:<br />
Chiller and heat pump performances are calculated in accordance with the EN14511 : 2011 calculation standard and certified by Eurovent.<br />
31<br />
Index<br />
The latest version of EN14511 was ratified on July 19th, 2011. It uses a different method to take into account the contribution of water pumps, or heat exchanger pressure drops in the unit performances. The efficiency of<br />
the pump is no longer a default value, but a function of the required hydraulic power. In January 2012, the Eurovent Certification Company decided that this method is more realistic and it is fully applied starting<br />
from the 2012 certification campaign. The performances declared based on the new version of the standard were published on the ECC website www.eurovent-certification.com at the end of March 2012.<br />
IMPORTANT: Only 2012 performances rated according the new EN14511 : 2011, taking in account water pump and heat exchanger pressure drop are certified by Eurovent. For units declared before 2012, the<br />
previous gross EER and COP values without pump correction (for units with integral pump - measured with the pump not running) and the corresponding energy classes are available on ECC website.<br />
Application rating conditions<br />
Air conditioning applications (AC) - condition 1 Cooling and heating floor applications (CHF) - condition 2<br />
Air-cooled cooling Evaporator EWT/LWT 12°C/7°C<br />
Evaporator EWT/LWT 23°C/18°C<br />
OAT 35°C<br />
OAT 35°C<br />
Water-cooled cooling Evaporator EWT/LWT 12°C/7°C<br />
Evaporator EWT/LWT 23°C/18°C<br />
Condenser EWT/LWT 30°C/35°C<br />
Condenser EWT/LWT 30°C/35°C<br />
(1) Gross performances, not in accordance with EN14511-3:2011. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump<br />
to overcome the internal pressure drop in the heat exchanger.<br />
Legend<br />
EWT Entering water temperature<br />
LWT Leaving water temperature<br />
OAT Outdoor air temperature