DOUBLE-EFFECT STEAM-FIRED<br />

ABSORPTION CHILLERS<br />

Display and control board<br />

1<br />

2<br />

9<br />

10<br />

11<br />

12<br />

STOP RUN<br />

CHILLER / HEATER<br />

#1ABS PUMP<br />

#2ABS PUMP<br />

REF PUMP<br />

PURGE PUMP<br />

BURNER<br />

STAND BY COOLING<br />

DILUTION HEATING<br />

SAFETY CIRCUIT<br />

COMBUSTION<br />

CHILLER/HEATER ALARM<br />

BURNER ALARM<br />

POWER<br />

8<br />

SET BACK<br />

BUZZER STOP<br />

REMOTE<br />

LOCAL<br />

OPERATION<br />

STOP RUN<br />

symbol<br />

Name<br />

1 Operation indication lamp<br />

Lamp color<br />

Red<br />

2<br />

3 4<br />

4 5<br />

Stop indication lamp Stop indication<br />

Alarm indication lamp<br />

Alarm Combustion indication indication lamp<br />

Combustion Cooling / Heating indication<br />

lamp<br />

Green<br />

Orange<br />

Red<br />

Orange<br />

6 5<br />

7<br />

6 8<br />

7 9<br />

Remote / Local select button with lamp Cooling/heating indication<br />

Operation select button with lamp<br />

Remote/local Data display select button<br />

Operation Stand by indication mode lamp selection<br />

Red<br />

Red<br />

7segment LED(Red)<br />

Red<br />

10 Dilution indication lamp 8 Data display<br />

11 Safety circuit indication lamp<br />

9 12 Stand-by Power indication indication lamp<br />

10 GL Dilution Purger indication indication lamp<br />

43P Purge pump on - off switch<br />

11 Safety circuit indication<br />

43ES Emergency stop switch<br />

Orange<br />

Red<br />

White<br />

Green<br />

12 Power indication<br />

5<br />

6<br />

4<br />

7<br />

3<br />

Industrial<br />

SUPER ABSORPTION<br />

Features<br />

• Eighteen sizes with nominal cooling capacities from 345 to 4652 kW.<br />

• The 16NK absorption chillers are designed for cooling applications where<br />

low-pressure steam is available as waste heat.<br />

• Can tie into district steam systems.<br />

• Allows diversification of critical cooling requirements. Critical cooling loads<br />

are met with minimal electrical power input.<br />

• Allows use of smaller emergency generators since the electrical load associated<br />

with an absorption chiller is minimal.<br />

• Ozone-friendly and CFC-free.<br />

• Minimises global warming effect by greatly reducing power consumption and<br />

eliminating the generation of greenhouse gases.<br />

• Reduced noise and vibration levels. The absorption chiller does not use a large<br />

motor-compressor, leading to quiet, vibration-free operation.<br />

• Small footprint. The high efficiency associated with double-effect chillers<br />

results in a reduction of the required installation space.<br />

• Auto-diagnosis system monitors operating conditions, predicts chiller information<br />

and maintains stable operation.<br />

• Advanced high-precision control system.<br />

• Absorption pump with inverter control for efficient, energy-saving operation.<br />

• High-performance purge system minimises maintenance requirements.<br />

• State-of-the-art protection devices guarantee enhanced operating safety.<br />

152<br />