GENERAL CAtALoGuE 2013 - Carrier Portugal
GENERAL CAtALoGuE 2013 - Carrier Portugal
GENERAL CAtALoGuE 2013 - Carrier Portugal
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
DIRECT-FIRED DOUBLE-EFFECT<br />
ABSORPTION CHILLERS/HEATERS<br />
Display and control board<br />
1<br />
2<br />
9<br />
10<br />
11<br />
12<br />
STOP RUN<br />
CHILLER / HEATER<br />
#1ABS PUMP<br />
#2ABS PUMP<br />
REF PUMP<br />
PURGE PUMP<br />
BURNER<br />
STAND BY COOLING<br />
DILUTION HEATING<br />
SAFETY CIRCUIT<br />
COMBUSTION<br />
CHILLER/HEATER ALARM<br />
BURNER ALARM<br />
POWER<br />
8<br />
SET BACK<br />
BUZZER STOP<br />
REMOTE<br />
LOCAL<br />
OPERATION<br />
STOP RUN<br />
symbol<br />
Name Lamp color<br />
1<br />
2 3<br />
3 4<br />
Operation indication lamp Operation indication<br />
Stop indication lamp<br />
Stop Alarm indication<br />
lamp<br />
Alarm Combustion indication<br />
lamp<br />
Red<br />
Green<br />
Orange<br />
Red<br />
5<br />
4<br />
6<br />
5 7<br />
Cooling / Heating indication lamp<br />
Combustion indication<br />
Remote / Local select button with lamp<br />
Cooling/heating Operation select button indication<br />
with lamp<br />
Orange<br />
Red<br />
Red<br />
6 8 Remote/local Data display select button 7segment LED(Red)<br />
9<br />
7<br />
10<br />
8 11<br />
Stand by indication lamp<br />
Operation mode selection<br />
Dilution indication lamp<br />
Data Safety display circuit indication lamp<br />
Red<br />
Orange<br />
Red<br />
9 12 Stand-by Power indication indication lamp White<br />
GL Purger indication lamp<br />
10 Dilution indication<br />
43P Purge pump on - off switch<br />
11 43ES Safety Emergency circuit stop switch indication<br />
Green<br />
12 Power indication<br />
5<br />
6<br />
4<br />
7<br />
3<br />
SUPER ABSORPTION<br />
Features<br />
• Twenty-three sizes with nominal cooling capacities from 352 to 5274 kW and<br />
heating capacities from 268 to 4026 kW.<br />
• The 16DJ absorption chillers/heaters offer building owners a better solution for<br />
many new and retrofit applications. Installation of a direct-fired chiller/heater<br />
eliminates the need for a boiler, reducing the initial cost of the system.<br />
• Excellent for peak shaving during high electrical demand periods.<br />
• Allows diversification of critical cooling requirements. Critical loads are met<br />
with minimal electrical power input.<br />
• Allows use of smaller emergency generators since the electrical load associated<br />
with an absorption chiller is minimal.<br />
• Ozone-friendly and CFC-free.<br />
• Minimises global warming effect by greatly reducing power consumption.<br />
• Reduced noise and vibration levels. The absorption chiller does not use a large<br />
motor-compressor, leading to quiet, vibration-free operation.<br />
• Small footprint. The high efficiency associated with double-effect chillers<br />
results in reducing the required installation space.<br />
• Auto-diagnosis system monitors operating conditions, predicts chiller information<br />
and maintains stable operation.<br />
• Advanced high-precision control system.<br />
• Absorption pump with inverter control for efficient, energy-saving operation.<br />
• High-performance purge system minimises maintenance requirements.<br />
• State-of-the-art protection devices guarantee enhanced operating safety.<br />
150<br />
Industrial<br />
16DJ