TRIPOINT METHOD<br />

When shafts have a limited rotation or can only be rotated in one direction.<br />

Select the Tripoint method in the Application Set-up.<br />

NOTE: The shafts should be coupled during the measurement using the<br />

Tripoint TM method in order to achieve as reliable and accurate results as<br />

possible.<br />

TIP: The larger angle over which the three points are measured, the fewer<br />

moves and repeat measurements will have to be made. Minimum angle<br />

between readings is 30°.<br />

Measurement Procedure<br />

The screen displays the movable machine. Enter dimensions as for the Clock<br />

method. Set the TD units so that they are approximately parallel.<br />

33