Electric motors<br />

The choice of an operation type determines the<br />

selection of a motor for each function.<br />

The IEC 34 recommendation has defined several<br />

types of actuator standard duty cycles for determining<br />

the use conditions of an electric motor.<br />

IEC 34 STANDARD<br />

S1 : Continuous duty<br />

Operation with constant load over a sufficient duration for reaching<br />

a thermal equilibrium.<br />

S2 : Short time duty<br />

Short time operation, total cooling between each start.<br />

S3 : Intermittent periodic duty<br />

The starting current has no significant effect on temperature rise.<br />

To be followed by the max. operating time.<br />

S4 : Intermittent duty with starting<br />

Repetition of cycles including :<br />

● starting period D,<br />

● period of constant speed N,<br />

● rest period R.<br />

MODULATING<br />

To be followed by the duty factor in %, as well as the number of starts per hour.<br />

Our choice : S4<br />

13<br />

USER’S<br />

GUIDE<br />

CHOOSING<br />

THE RANGE<br />

Mechanical and<br />

electrical features<br />

The only duty cycle corresponding to the required<br />

actuator operation is S4. Its parameters will be<br />

optimised to fit each application.<br />

DUTY OBJECTIVE TYPE OF MOTOR TYPE OF DUTY FREQUENCY<br />

● Operating time Asynchronous AC : 360 starts/hour<br />

ON / OFF ● Successive starts 3 phase or single phase S4 - 30 % DC : 60 starts/hour<br />

Direct current<br />

● Operating time Asynchronous<br />

CLASS III ● Repetition of starts 3 phase or single phase S4 - 50 % 1 200 starts/hour<br />

(Direct current possible)<br />

● High number Asynchronous 3 phase<br />

CLASS II l of starts (Single phase possible) S4 - 100 % 1 800 starts/hour<br />

● Low inertia<br />

● Speed variation Brushless direct current<br />

CLASS I ● Continuous operation with servo drive S4 - 100 % NO LIMITS<br />

General technical data<br />

of AC motors<br />

➜ SQUIRREL CAGE type<br />

➜ Insulation CLASS F<br />

➜ Watertight enclosure<br />

➜ Built-in thermal protection<br />

General technical data<br />

of DC motors<br />

Applicable only for ON / OFF and Class III duty<br />

➜ <strong>CO</strong>MPOUND type winding<br />

➜ Insulation CLASS F<br />

➜ Watertight enclosure<br />

➜ Built-in thermal protection