Appendix C - Helpful NetScaler CLI<br />

Commands<br />

The NetScaler Application switch can also be managed and configured via CLI Commands, by connecting to the Serial port or a SSH<br />

connection to the NSIP. The following commands can be used in lieu of the NetScaler GUI for operations detailed in this deployment guide.<br />

> nsconfig (configns)<br />

> show rpcnodes<br />

> set rpcnode -password <br />

> disable interface <br />

> set interface -hamonitor OFF<br />

> add node <br />

> set node -hastatus STAYSECONDARY<br />

> set node -hastatus ENABLE<br />

> show node<br />

> force HA sync<br />

> force HA failover<br />

> set ha node –hasync DISABLE<br />

> set ha node –hasync ENABLE<br />

> show ip<br />

> show interface<br />