System <strong>Galaxy</strong> Quick Guide for <strong>Bioscrypt</strong> / L‐1 <strong>Setup</strong> <strong>and</strong> <strong>Enrollment</strong> System <strong>Galaxy</strong> Quick Guide<br />

INTEGRATION REQUIREMENTS (order dependent)<br />

1. System <strong>Galaxy</strong> & SecureAdmin Databases are both compatible with SQL Server 2005 or 2008<br />

2. System <strong>Galaxy</strong> 10.0 server/database should be installed before the SecureAdmin Server.<br />

3. SecureAdmin software 4.1.10 is only supported on Windows XP<br />

4. SecureAdmin server / client 4.1.10 must be installed using the setup.exe - found in the Installers/L1 folder<br />

on the <strong>Galaxy</strong> DVD (disk 1).<br />

5. During the SecureAdmin server install, select DEFAULT CERTIFICATE.<br />

6. <strong>Systems</strong> must be properly configured to support SQL Server connection:<br />

a) For shared SQL Server Instance (default option): choose to install on existing SQL server. Supply<br />

the SysGal database connection parameters when prompted by SecureAdmin install program.<br />

b) For Linked Server: you can install SecureAdmin on separate servers <strong>and</strong> use a connection string to link<br />

the databases. Insert the SQL connection path in SysGal’s SADB_PATH column of the<br />

L1_SADB_INFO table. You must also enter a 1 in the L1_ENABLE column.<br />

String example: [server_name\instance_name].[database_name].[owner_name]<br />

7. Each L-1 Reader must be registered via server in the SecureAdmin software before SG can connect.<br />

a) Secure Registration is done with the USB Cable that comes with the reader.<br />

When the Device Driver Wizard opens, you must browse to the 4gserial folder (located on<br />

the SecureAdmin server in Program Files\<strong>Bioscrypt</strong>\SA\SecureAdmin Server\4gserial.<br />

b) The reader must be configured for TCP/IP communication using valid IP settings for the same<br />

broadcast domain as the <strong>Galaxy</strong> enrollment workstation.<br />

8. In SecureAdmin, each reader must be configured for the correct card format (“26bit Pass-thru”, HID Corp<br />

1000, <strong>and</strong> custom “<strong>Galaxy</strong> 32bit Wieg<strong>and</strong>” are supported).<br />

9. You must enroll fingers from the System <strong>Galaxy</strong> cardholder screen.<br />

10. Templates are stored in BLOB format in the <strong>Galaxy</strong> database.<br />

11. System <strong>Galaxy</strong> 10.0 supports enrollment <strong>and</strong> interoperation using IDENTIFY (finger-only) <strong>and</strong> VERIFY<br />

(prox+finger in reader) modes with the Base <strong>and</strong> Prox models of the V-flex <strong>and</strong> V-station. SG 10.0 does not<br />

support Smart Card enrollment. SG 10.0 does not support PIN modes or memory expansion in the Vstation.<br />

12. SG must be registered for Biometric Support (Corporate or Enterprise) in System Registration.<br />

13. SG must have L-1 Solutions chosen as the biometric system in System Settings screen.<br />

14. SG must have L-1 Solutions chosen for the reader technology, <strong>and</strong> the specific L-1 Reader Name must be<br />

assigned to the door in the Reader Properties screen. Load Templates must be “checked”.<br />

15. System <strong>Galaxy</strong> must be able to connect to the SADB when it starts up <strong>and</strong> operator signs in. If unable to<br />

connect, the software displays a warning that the L1 Features will be disabled,<br />

16. You can capture from 1 to 10 prints per card. Prints are captured in the <strong>Enrollment</strong> screen <strong>and</strong> held in<br />

memory until the APPLY button is pressed in the main Cardholder screen.<br />

17. Authorized templates are sent to each reader when the Cardholder APPLY button is pressed. Likewise,<br />

templates are removed from each reader when the APPLY button is pressed.<br />

“Authorized templates” must have (a) valid loop privileges, (b) valid access group, <strong>and</strong> (c) the<br />

Send Templates option “checked” in the Cardholder screen.<br />

NOTICE: the Load Templates option must be “checked” in the reader properties.<br />

18. The L1 Load Utility will ‘bulk’ load all authorized templates on a per reader basis.<br />