09.11.2013 Views

Drive Solutions for the Global Oil and Gas Industry ... - GE Energy

Drive Solutions for the Global Oil and Gas Industry ... - GE Energy

Drive Solutions for the Global Oil and Gas Industry ... - GE Energy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

LCI Control Features:<br />

• Load commutation above 10% base speed<br />

• Sensorless speed control<br />

• Speed control range: 10-150% of base speed<br />

with logic to prevent reverse operation<br />

• Built-in regeneration <strong>for</strong> smooth control of<br />

loads<br />

Cabinet Lineup:<br />

Length - 158 in (4,000 mm) <strong>for</strong> 7,000 hp<br />

version.<br />

- 220 in (5,600 mm) <strong>for</strong> 18,000 hp<br />

version.<br />

Height - 100 in (2,500 mm) <strong>for</strong> all cabinets.<br />

Depth - 55 in (1,400 mm) <strong>for</strong> all cabinets.<br />

Cooling System<br />

In <strong>the</strong> closed loop cooling system, coolant<br />

circulates from <strong>the</strong> pump discharge, to <strong>the</strong> heat<br />

exchanger, to <strong>the</strong> power conversion bridges, <strong>and</strong><br />

back to <strong>the</strong> pump. Pumps can be switched over<br />

<strong>and</strong> changed without interrupting cooling.<br />

1<br />

N<br />

AC<br />

Voltage<br />

Input<br />

N +1 SCR<br />

redundancy<br />

Color Touch<br />

Screen<br />

Source Bridge<br />

DC Link<br />

Reactor<br />

Main<br />

Control<br />

Module<br />

VersaMax<br />

I/O Modules<br />

Load Bridge<br />

AC<br />

Voltage<br />

Output<br />

Optional<br />

Transf ormer<br />

Sy nchronous<br />

Motor<br />

Excitation<br />

Voltage<br />

Controller<br />

Optional Tach Signal<br />

LCI Source <strong>and</strong> Load Bridge Configuration<br />

SCR water<br />

cooling hoses<br />

Source bridge<br />

with series SCR<br />

cells <strong>and</strong> heat<br />

sinks<br />

Cell replacement without<br />

opening water cooling loop<br />

Revised: 5-22-09 © 2009 TMEIC <strong>GE</strong> Automation Systems. All Rights Reserved.<br />

Page 23 of 32