09.11.2013 Views

Drive Solutions for the Global Oil and Gas Industry ... - GE Energy

Drive Solutions for the Global Oil and Gas Industry ... - GE Energy

Drive Solutions for the Global Oil and Gas Industry ... - GE Energy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TMdrive-XL85 Adjustable Speed <strong>Drive</strong><br />

Converter:<br />

• Low harmonic distortion<br />

• Input from six windings<br />

• 36-pulse diode converter<br />

Converter<br />

(Source)<br />

Compartment<br />

1 of 3 phases shown in detail<br />

C (W)<br />

B (V)<br />

A (U)<br />

C (W)<br />

B (V)<br />

A (U)<br />

Inverter Compartment<br />

Phase-Leg<br />

Assemblies<br />

Inverter:<br />

• Low harmonic distortion<br />

• Five-level GCT circuit<br />

Synchronous motor <strong>for</strong><br />

high power levels.<br />

Voltage 7.6 kV<br />

M<br />

Trans<strong>for</strong>mer<br />

Redundant TMdrive-XL85 Configuration<br />

A redundant configuration of <strong>the</strong> TMdrive-XL85 can be<br />

built using four active channels (blocks) connected as<br />

shown in <strong>the</strong> diagram. The system has:<br />

• Four trans<strong>for</strong>mers <strong>and</strong> four TMdrive-XL85<br />

channels.<br />

• Four parallel connections.<br />

• A very clean wave<strong>for</strong>m.<br />

• Contacts to isolate any one channel.<br />

The redundant function is as follows:<br />

1. A problem is detected in one channel.<br />

2. The suspect channel is isolated <strong>and</strong> stopped.<br />

3. The three o<strong>the</strong>r channels continue operation <strong>and</strong><br />

deliver full power to <strong>the</strong> motor.<br />

4. The out-of-service channel is repaired <strong>and</strong><br />

brought back on line.<br />

Trans<strong>for</strong>mers<br />

T C I<br />

T C I<br />

T C I<br />

T C I<br />

TMdrive-85<br />

<strong>Drive</strong>s<br />

Simplified Block Diagram of Redundant ASD<br />

SM<br />

Synchronous<br />

Motor<br />

Revised: 5-22-09 © 2009 TMEIC <strong>GE</strong> Automation Systems. All Rights Reserved.<br />

Page 29 of 32

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!