09.11.2013 Views

Supplies Catalogue 2006/2007, (pdf; 4,27 MB) - Gerstel

Supplies Catalogue 2006/2007, (pdf; 4,27 MB) - Gerstel

Supplies Catalogue 2006/2007, (pdf; 4,27 MB) - Gerstel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

About this <strong>Catalogue</strong><br />

T<br />

his »Analytical <strong>Supplies</strong>« catalogue provides an extensive<br />

list of consumables, accessories and spare parts that<br />

are essential for the smooth operation of GERSTEL ® systems<br />

for chromatographic analysis. You have the right to demand<br />

the highest quality performance from GERSTEL systems and<br />

we have compiled this list so that this performance can be<br />

maintained throughout the life of your system.<br />

Please use only consumables, accessories and spare parts<br />

provided by GERSTEL. All GERSTEL products are made to<br />

exact specifications. Use of products not approved by GERSTEL<br />

can cause system malfunction or damage and may void the<br />

system’s warranty.<br />

If you have any questions please do not hesitate to contact us.<br />

The most efficient way is to reach us is through our web site at<br />

www.gerstel.com. Your questions can be answered even more<br />

quickly by linking to your local sales office through our site.<br />

2


Table of contents<br />

GRAPHPACK ® 2M connection technology ................................................................4<br />

GRAPHPACK 2M adapters with Swagelok thread, male ........................................6<br />

GRAPHPACK 2M adapters with Swagelok thread, female ........................................7<br />

GRAPHPACK 2M detector adapters .........................................................................8<br />

GRAPHPACK 2M inlet adapters .............................................................................. 10<br />

GRAPHPACK 2M dual column inlet adapter ........................................................... 12<br />

GRAPHPACK 2M MSD adapter .............................................................................. 14<br />

GRAPHPACK 2M dual column interface for MSD ................................................... 15<br />

GRAPHPACK 3D/2 connection technology ............................................................ 16<br />

GRAPHPACK 3D/2 column connector ................................................................... 18<br />

GRAPHPACK 3D/2 column connector with gas connection .................................... 18<br />

GRAPHPACK 3D/2 crosspieces ............................................................................. 19<br />

GERSTEL ® Cooled Injection System, CIS ...............................................................20<br />

GERSTEL Automated Liner Exchange, ALEX...........................................................28<br />

GERSTEL MultiPurpose Sampler, MPS 2 ................................................................30<br />

GERSTEL MultiPurpose Sampler, MPS 3 ................................................................42<br />

GERSTEL Twister ® Desorption Unit, TDU.................................................................48<br />

GERSTEL Twister ....................................................................................................52<br />

GERSTEL Thermal Desorption System, TDS ..........................................................56<br />

GERSTEL Pyrolysis Module, PM 1...........................................................................64<br />

GERSTEL Thermal Extractor, TE 1/2 ......................................................................66<br />

GERSTEL Tube Conditioner, TC 2 ..........................................................................68<br />

GERSTEL Column Switching Systems, MCS ..........................................................70<br />

GERSTEL Preparative Fraction Collector, PFC ........................................................72<br />

GERSTEL Olfactory Detector Port, ODP .................................................................76<br />

GERSTEL ChemSensor System ..............................................................................78<br />

GERSTEL Approved <strong>Supplies</strong> .................................................................................80<br />

Accessories by other leading analytical equipment suppliers ..................................84<br />

Index ......................................................................................................................85<br />

Page<br />

3


GRAPHPACK ® 2M connection technology<br />

Part No.<br />

For the rapid and economical connection of capillary columns to<br />

GC Inlets and Detectors.<br />

The components of the GRAPHPACK 2M connection technology<br />

are the GRAPHPACK 2M ferrule, the GRAPHPACK 2M adapter<br />

and the GRAPHPACK nut.<br />

GRAPHPACK 2M ferrule<br />

The GRAPHPACK 2M ferrule is a<br />

cylindrical metal cartridge packed with<br />

graphite.<br />

Advantages<br />

● Rapid and reliable installation/<br />

changing of capillary columns.<br />

● Rapid mounting and positioning of<br />

the ferrules on the capillary column<br />

outside the oven.<br />

● Leak-free connections are achieved<br />

without excessive tightening.<br />

● Connections remain leak-free with<br />

temperature cycling.<br />

● Self-centering of the ferrule on the<br />

GRAPHPACK 2M adapter.<br />

● The capillary column is always<br />

centered in the inlet or detector.<br />

● No damage to column coating.<br />

● Economical, no more than two<br />

ferrules are required for the life of<br />

a column.<br />

GRAPHPACK 2M<br />

Adapter<br />

Available for all column outside diameters<br />

between 0.2 mm and 0.8 mm.<br />

GRAPHPACK nut<br />

A slotted nut for securing the column to<br />

all GRAPHPACK adapters.<br />

4<br />

GRAPHPACK 2M and GRAPHPACK 3D/2 ferrules<br />

are not interchangeable.


GRAPHPACK ® 5<br />

Column OD / ID<br />

Part No.<br />

GRAPHPACK 2M ferrules<br />

1 package (10 units)<br />

0.20 mm / 0.1 mm 001805-020-00<br />

0.25 mm / 0.1 mm 001805-025-00<br />

0.31 mm / 0.20 mm 001805-031-00<br />

0.40 mm / 0.25 mm 001805-040-00<br />

0.45 mm / 0.32 mm 001805-045-00<br />

0.70 mm / 0.53 mm 001805-007-00<br />

0.80 mm / 0.<strong>27</strong> mm 001805-008-00<br />

(for glass)<br />

GRAPHPACK 2M plug ferrule<br />

1 package (5 units)<br />

0.31 mm / 0.20 mm 011654-031-00<br />

0.45 mm / 0.32 mm 011654-045-00<br />

0.70 mm / 0.53 mm 011654-007-00<br />

GRAPHPACK 2M<br />

mounting tool kit<br />

For mounting and positioning of<br />

GRAPHPACK 2M ferrules on capillary columns.<br />

Complete kit 006829-000-00<br />

Spare parts<br />

GRAPHPACK mounting tool for<br />

GRAPHPACK 2M ferrules<br />

tool body, without insert<br />

004938-000-00<br />

Column OD<br />

Inserts 0.31 mm (red) 006828-031-00<br />

0.40 to 0.45 mm (green) 006828-045-00<br />

0.70 to 0.80 mm (black) 006828-008-00<br />

GRAPHPACK nut<br />

for mounting tool<br />

1 package (5 units)<br />

000980-005-00<br />

OD = Outside diameter<br />

ID = Inside diameter


GRAPHPACK ® 2M adapters with<br />

Swagelok ® thread, female<br />

Part No.<br />

For the conversion of GC systems with Swagelok fittings<br />

to GRAPHPACK 2M technology.<br />

Column OD / ID<br />

Part No.<br />

with 1/4“ Swagelok female thread 0.31 mm / 0.20 mm 006835-031-00<br />

0.45 mm / 0.32 mm 006835-045-00<br />

0.70 mm / 0.53 mm 006835-007-00<br />

with 1/8“ Swagelok female thread 0.31 mm / 0.20 mm 006834-031-00<br />

0.45 mm / 0.32 mm 006834-045-00<br />

0.70 mm / 0.53 mm 006834-007-00<br />

with 1/16“ Swagelok female thread 0.31 mm / 0.20 mm 006833-031-00<br />

0.45 mm / 0.32 mm 006833-045-00<br />

0.70 mm / 0.53 mm 006833-007-00<br />

6<br />

GRAPHPACK 2M ferrules are not included with the GRAPHPACK<br />

detector adapters and must be ordered separately.<br />

When using 0.40 mm OD capillaries, use a 0.45 mm OD adapter in<br />

combination with a 0.40 mm ferrule.


GRAPHPACK ® 7<br />

GRAPHPACK 2M adapters with<br />

Swagelok ® thread, male<br />

Part No.<br />

For the conversion of GC systems with Swagelok fittings to<br />

GRAPHPACK 2M technology.<br />

Column OD / ID<br />

Part No.<br />

with 1/4“ Swagelok male thread<br />

0.31 mm / 0.20 mm 006832-031-00<br />

0.45 mm / 0.32 mm 006832-045-00<br />

0.70 mm / 0.53 mm 006832-007-00<br />

with 1/8“ Swagelok male thread 0.31 mm / 0.20 mm 006831-031-00<br />

0.45 mm / 0.32 mm 006831-045-00<br />

0.70 mm / 0.53 mm 006831-007-00<br />

with 1/16“ Swagelok male thread<br />

0.31 mm / 0.20 mm 006830-031-00<br />

0.45 mm / 0.32 mm 006830-045-00<br />

0.70 mm / 0.53 mm 006830-007-00


GRAPHPACK ® 2M detector adapters<br />

Part No.<br />

For the low-cost conversion of detector connections of various<br />

GC manufacturers to GRAPHPACK 2M connection technology.<br />

Advantages<br />

● Economical, only one sealing technology is used for all detectors.<br />

● No contact with the inside of the detector because of accurate<br />

centering.<br />

Column OD / ID<br />

Part No.<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

HP 5890 A and Series II and Agilent 6850/6890<br />

for FID, NPD<br />

0.31 mm / 0.20 mm 006508-031-00<br />

0.45 mm / 0.32 mm 006508-045-00<br />

0.70 mm / 0.53 mm 006508-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 003962-005-00<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

HP 5890 A and Series II and Agilent 6850/6890<br />

for TCD, FPD<br />

0.45 mm / 0.32 mm 006831-045-00<br />

0.70 mm / 0.53 mm 006831-007-00<br />

Chrompack 9000<br />

0.31 mm / 0.20 mm 006831-031-00<br />

0.45 mm / 0.32 mm 006831-045-00<br />

0.70 mm / 0.53 mm 006831-007-00<br />

Dani Detectors; M4 0.31 mm / 0.20 mm 008189-031-00<br />

0.45 mm / 0.32 mm 008189-045-00<br />

Spare parts<br />

0.70 mm / 0.53 mm 008189-007-00<br />

Silver seal; 1 package (5 units) 001383-005-00<br />

Fisons Series 8000, Trace,<br />

Tremetics, CE 5300, CE 8000<br />

0.31 mm / 0.20 mm 008190-031-00<br />

0.45 mm / 0.32 mm 008190-045-00<br />

0.70 mm / 0.53 mm 008190-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 000976-005-00<br />

8<br />

GRAPHPACK 2M ferrules are not included with the GRAPHPACK detector adapters<br />

and must be ordered separately.


GRAPHPACK ® 9<br />

Column OD / ID<br />

Part No.<br />

O.I. Analytical PID<br />

0.31 mm / 0.20 mm 008005-031-00<br />

0.45 mm / 0.32 mm 008005-045-00<br />

0.70 mm / 0.53 mm 008005-007-00<br />

O.I. Analytical PFPD and XSD<br />

Spare parts<br />

0.31 mm / 0.20 mm 010375-031-00<br />

0.45 mm / 0.32 mm 010375-045-00<br />

0.70 mm / 0.53 mm 010375-007-00<br />

Silver seal; 1 package (5 units) 005249-005-00<br />

Perkin Elmer<br />

Spare parts<br />

0.31 mm / 0.20 mm 008020-031-00<br />

0.45 mm / 0.32 mm 008020-045-00<br />

0.70 mm / 0.53 mm 008020-007-00<br />

Vespel graphite ferrule; 1 package (5 units) 009999-092-00<br />

Siemens RGC 0202<br />

Spare parts<br />

0.31 mm / 0.20 mm 008191-031-00<br />

0.45 mm / 0.32 mm 008191-045-00<br />

0.70 mm / 0.53 mm 008191-007-00<br />

Silver seal; 1 package (5 units) 003962-005-00<br />

Shimadzu 14 A and 17 A<br />

Spare parts<br />

0.31 mm / 0.20 mm 008068-031-00<br />

0.45 mm / 0.32 mm 008068-045-00<br />

0.70 mm / 0.53 mm 008068-007-00<br />

Silver seal; 1 package (5 units) 002841-005-00<br />

Shimadzu 2010<br />

Spare parts<br />

0.31 mm / 0.20 mm 006511-031-00<br />

0.45 mm / 0.32 mm 006511-045-00<br />

0.70 mm / 0.53 mm 006511-007-00<br />

Silver seal; 1 package (10 units) 005249-005-00<br />

Varian 3300 / 3400 / 3500 /<br />

3600 / 3800 / 3900 & Saturn<br />

Spare parts<br />

0.31 mm / 0.20 mm 008192-031-00<br />

0.45 mm / 0.32 mm 008192-045-00<br />

0.70 mm / 0.53 mm 008192-007-00<br />

Silver seal; 1 package (5 units) 001383-005-00<br />

Spare parts<br />

for all GRAPHPACK adapters<br />

GRAPHPACK nut; 1 package (5 units) 001268-005-00


GRAPHPACK ® 2M inlet adapters<br />

Part No.<br />

For the low-cost conversion of inlet<br />

connections of various GC<br />

manufacturers to GRAPHPACK 2M<br />

connection technology.<br />

Advantages<br />

● Economical, only one sealing technology is<br />

used for all inlets.<br />

● No contact with the inlet liner because of<br />

accurate centering.<br />

Column OD / ID<br />

Part No.<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

Split/splitless injector<br />

HP 5890 A and Series II and<br />

Agilent 6850/6890<br />

0.31 mm / 0.20 mm 006509-031-00<br />

0.45 mm / 0.32 mm 006509-045-00<br />

0.70 mm / 0.53 mm 006509-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 001362-005-00<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

HP 5890 A and Series II and<br />

Agilent 6850/6890 for TCD.<br />

0.45 mm / 0.32 mm 006831-045-00<br />

0.70 mm / 0.53 mm 006831-007-00<br />

Fisons Series 8000<br />

Split/splitless injector<br />

0.31 mm / 0.20 mm 007302-031-00<br />

0.45 mm / 0.32 mm 007302-045-00<br />

0.70 mm / 0.53 mm 007302-007-00<br />

Sold without silver seal and nut.<br />

Spare parts<br />

Silver seal. 11.5 mm OD; 1 package (5 units) 007301-005-00<br />

Perkin Elmer<br />

PSS Injector<br />

0.31 mm / 0.20 mm 008021-031-00<br />

0.45 mm / 0.32 mm 008021-045-00<br />

0.70 mm / 0.53 mm 008021-007-00<br />

Spare parts<br />

Vespel ferrule; 1 package (5 units) 009999-093-00<br />

10<br />

When using 0.40 mm OD capillaries, use a 0.45 mm OD adapter in combination with<br />

a 0.40 mm ferrule.


GRAPHPACK ® 11<br />

Column OD / ID<br />

Part No.<br />

Perkin Elmer<br />

Split/splitless injector<br />

0.31 mm / 0.20 mm 007464-031-00<br />

0.45 mm / 0.32 mm 007464-045-00<br />

0.70 mm / 0.53 mm 007464-007-00<br />

Spare parts<br />

Vespel ferrule 1/4“; 1 package (5 units) 009999-091-00<br />

Shimadzu 14 A, 17 A<br />

Split/splitless injector<br />

0.31 mm / 0.20 mm 008068-031-00<br />

0.45 mm / 0.32 mm 008068-045-00<br />

0.70 mm / 0.53 mm 008068-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 002841-005-00<br />

Shimadzu 2010<br />

Split/splitless injector<br />

0.31 mm / 0.20 mm 006511-031-00<br />

0.45 mm / 0.32 mm 006511-045-00<br />

0.70 mm / 0.53 mm 006511-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 005249-005-00<br />

Valco VICI Valve<br />

0.31 mm / 0.20 mm 008019-031-00<br />

0.45 mm / 0.32 mm 008019-045-00<br />

0.70 mm / 0.53 mm 008019-007-00<br />

Varian 3300 / 3400 / 3500 /<br />

3600 / 3800 / 3900 & Saturn<br />

0.31 mm / 0.20 mm 008192-031-00<br />

0.45 mm / 0.32 mm 008192-045-00<br />

0.70 mm / 0.53 mm 008192-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 001383-005-00<br />

Spare parts<br />

for all GRAPHPACK adapters<br />

GRAPHPACK nut; 1 package (5 units) 001268-005-00


GRAPHPACK ® 2M dual column<br />

inlet adapter<br />

Part No.<br />

This dual column inlet adapter permits the simultaneous connection<br />

of two fused silica capillary columns to one inlet. This allows<br />

a sample to be analyzed on two columns simultaneously from a<br />

single injection. Adapters are available for GERSTEL ® inlets as well<br />

as for all major GC manufactures.<br />

Advantages<br />

● Reduction in analysis time.<br />

● Simultaneous analysis using capillary columns with different<br />

polarities.<br />

● No split discrimination due to contact of the capillary column<br />

with the inside wall of the inlet liner thanks to column selfcentering<br />

design.<br />

Column OD / ID<br />

Part No.<br />

GERSTEL Cooled Injection<br />

System CIS 3 and CIS 4<br />

0.31 mm / 0.20 mm 007530-031-00<br />

0.45 mm / 0.32 mm 007530-045-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 002841-005-00<br />

12


GRAPHPACK ® 13<br />

Column OD / ID<br />

Part No.<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

Split/splitless injector<br />

HP 5890 A and Series II and Agilent 6890<br />

0.31 mm / 0.20 mm 007533-031-00<br />

0.45 mm / 0.32 mm 007533-045-00<br />

0.70 mm / 0.53 mm 007533-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 001362-005-00<br />

Fisons Series 8000<br />

Split/splitless injector<br />

0.31 mm / 0.20 mm 008030-031-00<br />

0.45 mm / 0.32 mm 008030-045-00<br />

0.70 mm / 0.53 mm 008030-007-00<br />

Spare parts<br />

Silver seal. 5 mm OD; 1 package (10 units) 001402-010-00<br />

Silver seal. 11.5 mm OD; 1 package (5 units) 007301-005-00<br />

Perkin Elmer<br />

Split/splitless injector<br />

0.31 mm / 0.20 mm 007671-031-00<br />

0.45 mm / 0.32 mm 007671-045-00<br />

0.70 mm / 0.53 mm 007671-007-00<br />

Spare parts<br />

Vespel ferrule 1/4“; 1 package (5 units) 009999-091-00<br />

Carlo Erba CE 5300 0.31 mm / 0.20 mm 009040-031-00<br />

0.45 mm / 0.32 mm 009040-045-00<br />

0.70 mm / 0.53 mm 009040-007-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 000976-005-00<br />

Silver seal; 1 package (10 units) 001402-010-00<br />

When using 0.40 mm OD capillary, use a 0.45 mm OD adapter in combination with a<br />

0.40 mm ferrule.


Part No.<br />

GRAPHPACK ® 2M MSD adapter<br />

For the low-cost conversion of MSD connections of various GC<br />

manufacturers to GRAPHPACK 2M connection technology.<br />

Advantages<br />

● Economical, only one sealing technology is used for the capillary<br />

column.<br />

● Leak-free at elevated or fluctuating temperatures and under high<br />

vacuums.<br />

Column OD / ID<br />

Part No.<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

MSD HP 5971 / 5972,<br />

Agilent 5973A / 5973N /<br />

5973 inert, 5975, HP GCD<br />

0.31 mm / 0.20 mm 006511-031-00<br />

0.40 mm / 0.25 mm 006511-040-00<br />

0.45 mm / 0.32 mm 006511-045-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 005249-005-00<br />

14


GRAPHPACK ® 15<br />

GRAPHPACK 2M dual column<br />

interface for MSD<br />

Part No.<br />

For the simultaneous connection of two capillary columns to a<br />

single MSD<br />

Advantages<br />

● Use of two different polarity capillary columns with one MSD.<br />

Column OD / ID<br />

Part No.<br />

.<br />

Hewlett-Packard<br />

MSD HP 5971/5972<br />

0.31 mm / 0.20 mm 007233-031-00<br />

0.40 mm / 0.25 mm 007233-040-00<br />

0.45 mm / 0.32 mm 007233-045-00<br />

Spare parts<br />

Vespel ferrule; 1 package (5 units) 007348-005-00<br />

Interface nut; 1 package (5 units) 007236-005-00<br />

Agilent Technologies /<br />

Hewlett-Packard<br />

MSD Agilent/HP 5973A,<br />

5973N, 5973 inert, 5975<br />

0.31 mm / 0.20 mm 008599-031-00<br />

0.40 mm / 0.25 mm 008599-040-00<br />

Spare parts<br />

Vespel ferrule; 1 package (5 units) 009999-093-00<br />

Inferface nut; 1 package (5 units) 007236-005-00


GRAPHPACK ®<br />

3D/2 connection<br />

technology<br />

For the rapid, reliable and low-dead-volume<br />

connection of two capillary columns with<br />

the same or different outside diameter, or<br />

of different materials.<br />

The components of the GRAPHPACK 3D/2<br />

connection technology are the GRAPHPACK<br />

3D/2 ferrule, the GRAPHPACK 3D/2 connector<br />

and the GRAPHPACK 3D/2 screw.<br />

Sulfinert ®<br />

Part No.<br />

All GRAPHPACK 3D/2 components which come into contact with analytes are<br />

Sulfinert ® coated. This offers the optimal surface material for every GC analysis.<br />

Sulfinert is the latest in passivation coating technology, the next generation of the<br />

well-known Silcosteel® coating.<br />

The Sulfinert coating is ideal for use in all GC applications such as environmental,<br />

flavour and fragrance, off-odors, food and beverage, chemical and petrochemical,<br />

pharmaceutical and polymers. Sulfinert is stable over a wide pH range and unlike fused<br />

silica coatings, which can dissolve in caustic environments; the Sulfinert coating is<br />

stable when sampling caustic amines as well as acidic sulfur compounds.<br />

Sulfinert provides for the determination of ultra-low levels of organic compounds and<br />

superior inertness for sulfur compounds, simplifying the choice of passivation surface.<br />

When working with GERSTEL ® GRAPHPACK 3D/2 products, there is no need to use<br />

different passivation surfaces for different applications or different analytes.<br />

GERSTEL GRAPHPACK 3D/2 is offered with only one type of surface passivation:<br />

The very best.<br />

1<br />

1<br />

GRAPHPACK 3D/2<br />

ferrule<br />

3<br />

GRAPHPACK 3D/2<br />

screw<br />

2<br />

The GRAPHPACK 3D/2 ferrule<br />

is a cylinder metal packed with<br />

graphite.<br />

Advantages<br />

● Suitable for high pressures and temperatures<br />

as well as high vacuum.<br />

● Rapid mounting and positioning on<br />

the column outside the oven.<br />

● Leak-free connections are achieved<br />

without excessive tightening.<br />

● Connections remain leak-free with<br />

temperature cycling.<br />

● Self-centering of the ferrule in the<br />

connector.<br />

4<br />

The screw secures the<br />

capillary column and the<br />

GRAPHPACK 3D/2 ferrule in<br />

the connector.<br />

GRAPHPACK 3D/2 sealing<br />

ferrule<br />

This is a GRAPHPACK 3D/2 ferrule<br />

with a fixed sealing wire for the low<br />

dead-volume sealing of an<br />

outlet which is not needed on<br />

GRAPHPACK 3D/2 crosspieces<br />

and switching in use.<br />

3<br />

4<br />

2<br />

GRAPHPACK 3D/2<br />

connectors<br />

Column connectors, crosspieces<br />

and switching devices for the<br />

connection of two to four capillary<br />

columns of the same or different<br />

diameters.<br />

Advantages<br />

● No dead volume occurs as the<br />

result of an outlet which is not<br />

needed.<br />

● No graphite enters the<br />

GRAPHPACK 3D/2 crosspiece or<br />

switching device as an appropriate<br />

sealing ferrule is available for every<br />

column diameter.<br />

Advantages<br />

● Low thermal mass.<br />

● Low dead-volume.<br />

16<br />

GRAPHPACK 2M and GRAPHPACK 3D/2 ferrules<br />

are not interchangeable.


GRAPHPACK ® 17<br />

Column OD / ID<br />

Part No.<br />

GRAPHPACK 3D/2 ferrules<br />

1 package (10 units)<br />

0.20 mm / 0.1 mm 001705-020-00<br />

0.25 mm / 0.1 mm 001705-025-00<br />

0.31 mm / 0.20 mm 001705-031-00<br />

0.40 mm / 0.25 mm 001705-040-00<br />

0.45 mm / 0.32 mm 001705-045-00<br />

0.70 mm / 0.53 mm 001705-007-00<br />

0.80 mm / 0.<strong>27</strong> mm 001705-008-00<br />

(glass capillary)<br />

GRAPHPACK 3D/2 screw<br />

1 package (1 units)<br />

0.20 mm / 0.1 mm 005615-020-00<br />

0.25 mm / 0.1 mm 005615-025-00<br />

0.31 mm / 0.20 mm 005615-031-00<br />

0.40 mm / 0.25 mm 005615-040-00<br />

0.45 mm / 0.32 mm 005615-045-00<br />

0.70 mm / 0.53 mm 005615-007-00<br />

0.80 mm / 0.<strong>27</strong> mm 005615-008-00<br />

(glass capillary)<br />

GRAPHPACK 3D/2 sealing<br />

ferrule for GRAPHPACK 3D/2<br />

crosspieces<br />

1 package (5 units)<br />

0.20 mm / 0.1 mm 006520-020-00<br />

0.25 mm / 0.1 mm 006520-025-00<br />

0.31 mm / 0.20 mm 006520-031-00<br />

0.40 mm / 0.25 mm 006520-040-00<br />

0.45 mm / 0.32 mm 006520-045-00<br />

0.70 mm / 0.53 mm 006520-007-00<br />

0.80 mm / 0.<strong>27</strong> mm 006520-008-00<br />

(glass capillary)


Part No.<br />

GRAPHPACK ® 3D/2 column connector Sulfinert ®<br />

For the connection of two capillary columns with the<br />

same or different diameters or of different materials.<br />

Column OD / ID<br />

Column OD / ID<br />

Part No.<br />

from 0.70 / 0.53 mm to<br />

0.31 mm / 0.20 mm 013407-031-00<br />

0.40 mm / 0.25 mm 013407-040-00<br />

0.45 mm / 0.32 mm 013407-045-00<br />

0.70 mm / 0.53 mm 013407-007-00<br />

from 0.45 / 0.32 mm to<br />

0.31 mm / 0.20 mm 013445-031-00<br />

0.40 mm / 0.25 mm 013445-040-00<br />

0.45 mm / 0.32 mm 013445-045-00<br />

from 0.40 / 0.25 mm to<br />

0.40 mm / 0.25 mm 013440-040-00<br />

from 0.31 / 0.20 mm to<br />

0.31 mm / 0.20 mm 013431-031-00<br />

GRAPHPACK 3D/2 column connector Sulfinert ®<br />

with gas connection<br />

GRAPHPACK 3D/2 column connector with gas connection<br />

For the connection of two capillary columns with the same<br />

or different diameters or of different materials and the<br />

connection of make-up gas.<br />

Column OD / ID<br />

Column OD / ID<br />

Spare parts<br />

see page 17<br />

Part No.<br />

from 0.80 to<br />

0.45 mm / 0.32 mm 013508-045-00<br />

from 0.70 / 0.53 mm to<br />

0.31 mm / 0.20 mm 013507-031-00<br />

0.40 mm / 0.25 mm 013507-040-00<br />

0.45 mm / 0.32 mm 013507-045-00<br />

0.70 mm / 0.53 mm 013507-007-00<br />

from 0.45 / 0.32 mm to<br />

from 0.40 / 0.25 mm to<br />

0.31 mm / 0.20 mm 013545-031-00<br />

0.40 mm / 0.25 mm 013545-040-00<br />

0.45 mm / 0.32 mm 013545-045-00<br />

0.40 mm / 0.25 mm 013540-040-00<br />

from 0.31 / 0.20 mm to<br />

0.31 mm / 0.20 mm 013531-031-00<br />

18<br />

GRAPHPACK 3D/2 column connectors with or without one gas connection<br />

include two GRAPHPACK 3D/2 ferrules.


GRAPHPACK ® 19<br />

Part No.<br />

GRAPHPACK 3D/2 crosspieces Sulfinert ®<br />

For the connection up to 4 capillary columns with<br />

the same or different diameters or of different materials.<br />

main column<br />

outside diameter<br />

Part No.<br />

GRAPHPACK 3D/2<br />

crosspiece kit<br />

contains<br />

GRAPHPACK 3D/2 crosspiece<br />

GRAPHPACK 3D/2 ferrules<br />

Universal bracket for crosspiece<br />

GRAPHPACK mounting tool kit<br />

0.31 mm 012224-031-00<br />

0.45 mm 012224-045-00<br />

0.70 mm 012224-007-00<br />

Spare parts<br />

GRAPHPACK 3D/2 crosspiece 0.31 mm 012240-031-00<br />

0.40 mm 012240-040-00<br />

0.45 mm 012240-045-00<br />

0.70 mm 012240-007-00<br />

Universal bracket for crosspiece<br />

006188-000-00<br />

1<br />

1<br />

GRAPHPACK mounting tool kit<br />

for GRAPHPACK 3D/2 column<br />

connectors + crosspieces<br />

Complete kit 013492-000-00<br />

Spare parts<br />

2<br />

GRAPHPACK mounting tool<br />

tool body without insert<br />

003424-000-00<br />

2<br />

3<br />

Insert for 1.2 mm<br />

column mounting depth<br />

Color red 008994-003-00<br />

4<br />

Insert holder<br />

main column<br />

outside diameter<br />

0.20 mm to 0.31 mm 008995-031-00<br />

3<br />

4<br />

0.40 mm to 0.45 mm 008995-045-00<br />

0.70 mm to 0.80 mm 008995-008-00


GERSTEL ® Cooled Injection System, CIS<br />

Part No.<br />

Universal inlet for gas chromatography<br />

The GERSTEL CIS is a temperature<br />

programmable GC inlet. The CIS offers<br />

septumless, cold injection of volumes<br />

of up to 1000 µl for liquid samples. The<br />

integrated split function enables the CIS to<br />

handle ultra-trace concentrations as well<br />

as undiluted samples. Programmed linear<br />

heating ensures quantitative, discrimination-free<br />

transfer of sample components<br />

to the GC column for best possible GC<br />

analysis results.<br />

The CIS is a general purpose, universal<br />

GC inlet. When working with Thermal<br />

Desorption or Headspace techniques,<br />

the CIS is used for enrichment, focusing<br />

and quantitative transfer of analytes to the<br />

capillary column.<br />

An integral part of the CIS is the<br />

GERSTEL MAS controller, which can be<br />

used to control all GERSTEL modules,<br />

thus ensuring easy, cost effective system<br />

upgrades. The CIS can be retrofitted to<br />

existing Agilent Technologies/HP gas<br />

chromatographs.<br />

GERSTEL GRAPHPACK ® technology and<br />

septumless sampling head are standard<br />

features. A choice of liquid CO2, liquid N2<br />

or Peltier cooling is available. Available<br />

CIS models cover the temperature range<br />

from –150 to +600 °C. Compounds<br />

covering a wide boiling range can be<br />

efficiently trapped with subsequent<br />

discrimation-free analyte transfer to the<br />

capillary column. The CIS is compatible<br />

with all GERSTEL autosamplers - and<br />

with autosamplers from all major manufacturers.<br />

20


GERSTEL ® Cooled Injection System, CIS<br />

Part No.<br />

Septumless sampling head (SLH)<br />

for CIS 3 / 4 / 6<br />

(for 23 gauge needles)<br />

For manual or auto-injection<br />

CIS 3 003089-064-00<br />

CIS 4 / CIS 6 007513-064-00<br />

Service kit for SLH<br />

Complete<br />

009999-010-00<br />

3<br />

Contains one unit each of the following items:<br />

1 Plunger 004230-000-00<br />

2 Spring 009999-014-00<br />

3 Inner-O-Ring (Kalrez) 009999-015-00<br />

4 Outer-O-Ring (Viton) * 009999-016-00<br />

2<br />

1<br />

* When reordering only complete original package size is available (5 units).<br />

4<br />

SLH cap<br />

23 gauge needles 006144-064-00<br />

Teflon needle guide for SLH<br />

1 package (10 units)<br />

23 gauge needles 003091-064-00<br />

Carrier gas connection<br />

for SLH<br />

1<br />

4<br />

Complete kit 005610-000-00<br />

2<br />

1<br />

2<br />

3<br />

4<br />

Aluminium seal for SLH 1 package (5 units) 004256-005-00<br />

Screw 1 package (1 units) 001459-003-00<br />

Teflon ferrule 1/16” 1 package (10 units) 001576-010-00<br />

Knurled nut 1 package (5 units) 001117-005-00<br />

3<br />

21


Column OD / ID<br />

Part No.<br />

GRAPHPACK ® 2M adapter<br />

for CIS<br />

CIS 3 / CIS 4<br />

(silver)<br />

0.31 mm / 0.20 mm 007259-031-00<br />

0.45 mm / 0.32 mm 007259-045-00<br />

0.70 mm / 0.53 mm 007259-007-00<br />

Spare parts<br />

CIS 6<br />

(Stainless steel)<br />

0.31 mm / 0.20 mm 013244-031-00<br />

0.45 mm / 0.32 mm 013244-045-00<br />

0.70 mm / 0.53 mm 013244-007-00<br />

Silver seal; 1 package (5 units) 002841-005-00<br />

GRAPHPACK nut; 1 package (5 units) 001268-005-00<br />

Septum head<br />

without septum purge<br />

CIS 3 002835-000-00<br />

CIS 4 / CIS 6 007514-000-00<br />

Septum head<br />

with septum purge<br />

CIS 3 008577-000-00<br />

CIS 4 / CIS 6 008584-000-00<br />

1<br />

Spare parts<br />

2<br />

1<br />

Septum cap 006460-000-00<br />

2<br />

Septum for CIS 3/4, white; 1 package (25 units) 008246-025-00<br />

3<br />

Teflon ferrule 1/16”; 1 package (10 units) 001576-010-00<br />

3<br />

4<br />

Knurled nut; 1 package (5 units) 001117-005-00<br />

4<br />

Adsorption trap<br />

for split outlet<br />

1/16“ inlet, 1/16“ outlet connection,<br />

filled with charcoal<br />

005243-001-00<br />

22


GERSTEL ® Cooled Injection System, CIS<br />

Column OD / ID<br />

Part No.<br />

GRAPHPACK ® 2M dual column<br />

injector adapter<br />

For the simultaneous connection of two<br />

analytical capillary columns to a single CIS<br />

inlet.<br />

0.31 mm / 0.20 mm 007530-031-00<br />

0.45 mm / 0.32 mm 007530-045-00<br />

Spare parts<br />

Silver seal; 1 package (5 units) 002841-005-00<br />

GRAPHPACK nut; 1 package (5 units) 003714-005-00<br />

On Column kit<br />

1<br />

On Column insert; single CIS 3 005532-000-00<br />

CIS 4 / CIS 6 008339-000-00<br />

2<br />

GRAPHPACK 3D ferrule; CIS 3 002426-005-00<br />

1 package (5 units) CIS 4 / CIS 6 007541-005-00<br />

1<br />

2<br />

3<br />

GRAPHPACK 2M adapter CIS 3 / CIS 4 007259-007-00<br />

CIS 6 013244-007-00<br />

4<br />

GRAPHPACK 2M ferrule; 1 package (10 units) 001805-007-00<br />

4<br />

3<br />

5<br />

Silver seal; 1 package (5 units) 002841-005-00<br />

6<br />

Teflon needle guide (0.47 mm); 1 package (10 units) 003091-047-00<br />

5<br />

7<br />

Cap (0.47 mm) 006144-047-00<br />

6<br />

7<br />

23


Part No.<br />

Glass liners for CIS<br />

Part No.<br />

Part No.<br />

packed * deactivated description / typical use units CIS 3 CIS 4 / CIS 6 **<br />

– straight with notch 10 011708-010-00 011709-010-00<br />

Initial system checkout; user custom-packed<br />

liners; hot split/splitless injections<br />

– baffled 10 011710-010-00 011711-010-00<br />

General use liquid injection for<br />

moderate/high boilers, labile compounds,<br />

split injections<br />

– for SPME ID 1mm 10 – 011712-010-00<br />

for injection with MPS 2 with SPME Option<br />

with liquid injection for moderate/high boilers, 10 010849-010-00 010850-010-00<br />

silanized<br />

stable compounds; thermal desorption<br />

glass wool<br />

cryotrapping of stable compounds<br />

with More inert than glass wool; used for trapping 10 008420-010-00 007519-010-00<br />

quartz wool<br />

labile compounds<br />

with glass Provides additional surface area compared 5 – 011714-005-00<br />

beads<br />

to empty liner<br />

with glass beads Trapping volatiles with a wide range of 5 – 011716-005-00<br />

and Carbotrap C<br />

boiling points<br />

with Tenax TA Trapping of C 5 and higher volatiles 5 013249-005-00 013247-005-00<br />

(– 50 °C minimum temperature)<br />

with Carbotrap B Trapping of low boiling volatiles 5 013250-005-00 013248-005-00<br />

– straight with notch 10 002425-010-00 013881-010-00<br />

Initial system checkout; user custom-packed<br />

liners; hot split/splitless injections<br />

– baffled 10 002930-010-00 013882-010-00<br />

General use liquid injection for<br />

moderate/high boilers, labile compounds,<br />

split injections<br />

– ID 2 mm 10 – 013910-010-00<br />

for special applications<br />

with General use liquid injection for moderate/ 10 002931-010-00 014284-010-00<br />

silanized<br />

high boilers, stable compounds; thermal<br />

glass wool<br />

desorption cryotrapping of stable compounds<br />

Quartz liners<br />

Part No.<br />

packed * deactivated description / typical use units CIS 4 / CIS 6<br />

– – straight with notch 1 013238-000-00<br />

For hot split/splitless injection to 650°C 5 013238-005-00<br />

– – baffled 1 013148-000-00<br />

General se liquid injection for moderate/ 5 013148-005-00<br />

high boilers, labile compounds,<br />

split injections to 650 °C<br />

with – Used for trapping labile compounds 1 013605-000-00<br />

quartz wool 5 013605-005-00<br />

24<br />

*<br />

**<br />

All packed liners use the „straight with notch“ liner.<br />

These glass liners are to be used to 450 °C only when working with a CIS 6. For higher temperatures<br />

than 450 °C only quartz liners are allowed !


GERSTEL ® Cooled Injection System, CIS<br />

Part No.<br />

Glass liner kits<br />

consisting of:<br />

Part No.<br />

Part No.<br />

units CIS 3 CIS 4 / CIS 6 **<br />

• straight with notch, deactivated 2 013543-003-00 013543-004-00<br />

• baffled, deactivated 2<br />

• packed with silanized glass wool, deactivated 2<br />

• packed with Tenax 2<br />

• packed with Carbopack B 2<br />

GRAPHPACK ® 3D ferrules for glass liners<br />

1 package (5/10 units)<br />

Part No.<br />

Part No.<br />

units CIS 3 CIS 4 / CIS 6 **<br />

5 002426-005-00 007541-005-00<br />

10 002426-010-00 007541-010-00<br />

Kalrez ferrule (not in conjunction with TDS / TDU)<br />

Part No.<br />

Part No.<br />

units CIS 3 CIS 4 / CIS 6 **<br />

2 - 011868-002-00<br />

GRAPHPACK 3D mounting tool<br />

for glass liners<br />

CIS 3 003079-000-00<br />

CIS 4 / CIS 6 007542-000-00<br />

Cryo tube<br />

2 m<br />

CIS 4 / CIS 6<br />

with CIS adapter 006124-004-00<br />

CIS 4 / CIS 6<br />

1/4 “ Swagelok ® 006124-020-00<br />

25


Part No.<br />

Microliter syringes<br />

injection type system description µL units Part No.<br />

manual injection CIS fixed needle 5 1 009980-040-00<br />

10 1 009996-059-00<br />

25 1 009970-010-00<br />

50 1 009970-011-00<br />

100 1 009970-012-00<br />

manual injection CIS gastight 100 1 009999-019-00<br />

250 1 009999-018-00<br />

500 1 009999-017-00<br />

1000 1 009999-021-00<br />

Spare<br />

TLL needle 3 009999-006-00<br />

26


GERSTEL ® Cooled Injection System, CIS<br />

Part No.<br />

Microliter syringes<br />

injection / sampler system description µL units Part No.<br />

manual injection CIS needle-in-needle 1 1 009999-041-00<br />

Autosampler CIS fixed needle 5 1 009980-028-00<br />

HP 7673 / 5 6 009980-029-00<br />

Agilent 7683 10 1 009980-030-00<br />

10 6 009980-031-00<br />

Autosampler CIS replaceable needle 25 1 009980-032-00<br />

HP 7673 / 50 1 009970-013-00<br />

Agilent 7683 100 1 009970-014-00<br />

Spare<br />

needle 2 009980-033-00<br />

Autosampler CIS fixed needle, 10 1 009999-052-00<br />

HP 7673 /<br />

on-column-injection<br />

Agilent 7683<br />

<strong>27</strong>


Part No.<br />

GERSTEL ®<br />

Automated Liner EXchange, ALEX<br />

For routine GC analysis of samples, that contain large amounts of solid<br />

material. Designed for use with the GERSTEL MultiPurpose Sampler,<br />

MPS 2 and the GERSTEL Cooled Injection System, CIS. GC inlet liners<br />

can be replaced automatically at user-defined intervals in the sequence.<br />

A special ALEX liner tray holds up to 98 prepared liners, enabling<br />

routine analysis of large numbers of dirty samples.<br />

Part No.<br />

Universal syringe holder<br />

Version 2; compatible with ALEX<br />

013822-000-00<br />

ALEX transportion adapter<br />

for CIS 4 Liner<br />

1 units 013795-000-00<br />

10 units 013795-010-00<br />

O ring kit for ALEX<br />

transport adapter<br />

1 package (5 × 4 units)<br />

013934-005-00<br />

28


GERSTEL ® Automated Liner EXchange, ALEX<br />

Part No.<br />

Septa<br />

Ice blue, for liquid injection,<br />

5 mm, 1 package (100 units)<br />

014052-100-00<br />

Allen wrench<br />

for transport adapter screws, 4 mm<br />

009999-204-00<br />

O ring<br />

for ALEX sampling head,<br />

1 package (10 units)<br />

013931-010-00<br />

Glass inserts for ALEX sample tray<br />

10 units 013794-010-00<br />

100 units 013794-100-00<br />

O ring for ALEX sample<br />

tray glass inserts<br />

10 units 014292-010-00<br />

100 units 014292-100-00<br />

29


GERSTEL ® MultiPurpose Sampler, MPS 2<br />

Part No.<br />

The GERSTEL MultiPurpose Sampler,<br />

MPS 2 is a highly flexible and productive<br />

autosampler and sample preparation robot<br />

for GC and GC/MS analysis. The MPS 2<br />

can automate everything from sample<br />

preparation to sample introduction. The<br />

MPS 2 is easily adapted to both new<br />

and existing instruments. The system is<br />

installed on top of the GC, saving valuable<br />

bench space, and is compatible with all<br />

standard laboratory GC systems.<br />

GERSTEL MASter Software enables<br />

integrated control of the MPS 2 and a<br />

GC or GC-MS system from one method<br />

and one integrated sequence list through<br />

the Agilent ® Technologies ChemStation<br />

Software.<br />

The GERSTEL MPS PrepStation is a<br />

dual-rail/dual robot configuration of the<br />

MPS 2 MultiPurpose Sampler.<br />

The PrepStation performs fully<br />

automated sample preparation and<br />

sample introduction. One MPS rail of<br />

the MPS PrepStation is an automated<br />

liquid sample handler that performs<br />

a wide range of sample preparation<br />

functions. The second MPS rail enables<br />

many automated sample introduction<br />

options, including Headspace and SPME<br />

depending upon the selected MPS 2<br />

hardware configuration.<br />

The GERSTEL PrepBuilder Software<br />

enables overlapping sample preparation<br />

and GC analysis. While GC separation<br />

is in progress, the next sample is being<br />

prepared for analysis ensuring maximum<br />

productivity.<br />

Automated sample preparation<br />

steps include:<br />

• Dilution<br />

• Derivatization<br />

• Heating<br />

• Rinsing<br />

• Liquid-liquid extraction<br />

• Standard addition<br />

• Spiking<br />

• Agitation<br />

Automated sample introduction using a<br />

wide range of selectable techniques:<br />

• Standard liquid injection<br />

• Large-volume liquid injection<br />

• Headspace<br />

• SPME<br />

• Twister ® Option<br />

• Twister back-extraction<br />

• Membrane assisted solvent extraction<br />

Other techniques can be automated using<br />

the MPS 2 with special adaptations.<br />

MPS 2<br />

30


GERSTEL ® MultiPurpose Sampler, MPS<br />

Part No.<br />

Sample vials and caps for use with the MPS 2, MPS 2L,<br />

MPS 2XL and MPS PrepStation<br />

1<br />

Crimp cap vials<br />

Sampler Type Vials mL units Part No.<br />

MPS 2 Clear, colorless glass 0.7 100 093640-052-00 *<br />

2 100 1 093640-004-00<br />

10 100 2 093640-005-00<br />

20 100 3 093640-006-00<br />

100 100 093640-062-00<br />

2<br />

Crimp caps with septum for vials<br />

If vials need to be reopened and emptied after analysis,<br />

magnetic vial caps with aluminum edges (Bi-metal) offer<br />

the best solution. The softer edges allow easy crimping and<br />

decrimping using a hand-crimper. If steel caps are used, it is<br />

recommended to use a bench-top crimper.<br />

3<br />

Sampler Type Caps Vial volume (mL) units Part No.<br />

MPS 2<br />

Aluminium with septum<br />

PTFE red / Silicone / PTFE red,<br />

for 8 mm vial 0.7 100 093640-053-00<br />

*<br />

Magnetic, golden with septum<br />

PTFE red / Silicone / PTFE red,<br />

for 11 mm vial 2 100 093640-007-00<br />

Magnetic, golden,<br />

Silicone blue transparent, 10/20 100 093640-008-00<br />

PTFE white, 3 mm, for 20 mm vial 10/20 1000 093640-015-00<br />

Bi-metall, magnetic, red, with septum<br />

Silicone blue transparent,<br />

PTFE white, 3 mm, for 20 mm vial 10/20 100 093640-063-00<br />

Magnetic, with Pharma Fix septum<br />

Silicone/PTFE 10/20 100 093640-064-00<br />

Delivery times upon request *<br />

31


Part No.<br />

Vials for SPME<br />

Special vial with thickened crimp neck for use with 20 mm cap 100 units 093640-035-00<br />

for SPME and 0.5 mm septa, with imprint »SPME«<br />

Crimp caps for SPME<br />

magnetic, golden, with septum<br />

For SPME applications, crimp caps of steel with silicone septa are recommended. If the sample is<br />

analyzed for silicone, it is recommended to use butyl rubber septa or natural rubber septa. For a leakfree<br />

seal, it is recommended to use a bench-top crimper.<br />

Sampler Crimp cap with septum: Vial volume (mL) units Part No.<br />

MPS 2<br />

Silicone creme, PTFE red, 1.5 mm,<br />

55° Shore A, for 20 mm SPME vial 20 100 093640-031-00<br />

Viton, 0.5 mm,<br />

75° Shore A, for 20 mm SPME vial 20 100 093640-032-00<br />

Natural rubber, red-orange / Teflon, 1.3 mm,<br />

55° Shore A, for 20 mm SPME vial 20 100 093640-034-00<br />

Butyl red / PTFE grey, 1.3 mm,<br />

55° Shore A, for 20 mm SPME vial 20 100 093640-050-00<br />

Screw neck vials<br />

Sampler Vials Vial volume (mL) units Part No.<br />

MPS 2 clear, incl. caps and septa, 11 mm 2 100 089355-076-00<br />

clear, for 18 mm screw caps 10 100 093640-038-00<br />

brown, for 18 mm screw caps; 20 100 093640-037-00<br />

without caps and septa<br />

clear, for 18 mm screw caps; 20 100 093640-036-00<br />

without caps and septa<br />

brown, for 18 mm screw caps; 10 100 093640-039-00<br />

without caps and septa<br />

Microliter inserts, clear,<br />

for 2 mL screw cap vials 0.1 100 093640-029-00<br />

Screw caps with septa<br />

magnetic, for 18 mm screw cap vials<br />

Caps with silicone septa, blue, transparent are recommended as standard. If the sample is<br />

analyzed for silicone, it is recommended to use screw-caps with butyl rubber septa or viton septa.<br />

Sampler Screw caps with septum Vial volume (mL) units Part No.<br />

MPS 2<br />

Silicone blue transparent / PTFE white,<br />

1.3 mm, 35° Shore A 10/20 100 093640-040-00<br />

Silicone white / PTFE blue,<br />

1.5 mm, 60° Shore A 10/20 100 093640-041-00<br />

Viton black,<br />

1.0 mm, 75° Shore A 10/20 100 093640-043-00<br />

Butyl red / PTFE grey,<br />

1.6 mm, 55° Shore A 10/20 100 093640-042-00<br />

32


GERSTEL ® MultiPurpose Sampler, MPS<br />

Part No.<br />

Part No.<br />

Septa for screw caps for 10/20 mL screw cap vials<br />

Sampler Septum type units Part No.<br />

MPS 2 Silicone blue transparent / PTFE white, 1.3 mm, 35° Shore A 100 093640-057-00<br />

Silicone white / PTFE blue, 1.5 mm, 60° Shore A 100 093640-056-00<br />

Viton black, 1.0 mm, 75° Shore A 100 093640-059-00<br />

Butyl red / PTFE grey, 1.6 mm, 55° Shore A 100 093640-058-00<br />

Screw cap vials for Twister ® Back Extraction<br />

Sampler Vials Vial volume (mL) units Part No.<br />

MPS 2<br />

for 10 mm Twisters:<br />

screw cap vial 32 x 11.6 mm,<br />

clear, for 11 mm screw cap 1.5 100 093640-046-00<br />

for 10 mm Twisters:<br />

insert 31 x 6 mm, clear 0.2 100 093640-047-00<br />

for 20 mm Twisters:<br />

screw cap vial 32 x 11.6 mm,<br />

clear, for 11 mm screw cap 1.1 100 093640-045-00<br />

Screw caps, blue, with septa, 9 mm.<br />

With embedded magnetic discs.<br />

septum: silicone, white / PTFE, red,<br />

1.0 mm, 55° Shore A. 1 package (100 units) 093640-048-00<br />

Inserts 2 mL, for Agitator<br />

1 package (6 units)<br />

For automated Twister Back Extraction<br />

analysis, 2 mL vials are transferred to the<br />

agitator. This requires special adaptors inside<br />

the agitator.<br />

093631-002-00<br />

*<br />

Delivery times upon request *<br />

33


Part No.<br />

Replacement kit for<br />

Standard wash station<br />

MPS 2 or MPS 2L<br />

consisting of:<br />

10 mL 10CV vials (10 units)<br />

wash cap Polypropylene Snap Cap (10 units)<br />

20-ST101 Silicone/PTFE Septa (10 units)<br />

093632-050-00 *<br />

Solvent bottle 100 mL<br />

includes cap and septum<br />

093631-054-00<br />

Caps and septa<br />

for 100 mL solvent bottle,<br />

1 package (10 units)<br />

093631-055-00<br />

Crimper<br />

for 8 mm crimp caps (0.7 mL vials) 093640-054-00 *<br />

for 11 mm crimp caps (2 mL vials) 093640-000-00<br />

for 20 mm crimp caps (10/20 mL vials) 093640-001-00<br />

Decapper<br />

for 8 mm crimp caps (0.7 mL vials) 093640-053-00 *<br />

for 11 mm crimp caps (2 mL vials) 093640-002-00<br />

for 20 mm crimp caps (10/20 mL vials) 093640-003-00<br />

34<br />

Delivery times upon request *


GERSTEL ® MultiPurpose Sampler, MPS<br />

Part No.<br />

Part No.<br />

Bench-top crimper<br />

For easy crimping and de-crimping<br />

of vials, especially when steel caps<br />

are used or when large numbers of<br />

samples are analyzed.<br />

1<br />

1<br />

for crimp caps 20 mm 093640-009-00<br />

Spare parts / Option<br />

2<br />

Crimper head<br />

Decapper head<br />

Vial guide<br />

for crimp caps<br />

8 mm (0.7 mL vials) 093640-020-00 *<br />

11 mm (2 mL vials) 093640-017-00 *<br />

13 mm (4 mL vials) 093640-023-00 *<br />

20 mm (10/20 mL vials) 093640-010-00 *<br />

8 mm (0.7 mL vials) 093640-021-00 *<br />

11 mm (2 mL vials) 093640-018-00 *<br />

13 mm (4 mL vials) 093640-024-00 *<br />

8 mm (0.7 mL vials) 093640-022-00 *<br />

11 mm (2 mL vials) 093640-019-00 *<br />

13 mm (4 mL vials) 093640-025-00 *<br />

20 mm (10/20 mL vials) 093640-012-00 *<br />

2<br />

Microliter syringe<br />

For MPS 2, MPS 2L and MPS PrepStation, for use with CTC syringe adapter<br />

The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and are<br />

compatible with the GERSTEL ® Septumless Head (SLH). Needles have<br />

conical tips (type C or AS).<br />

1<br />

OD x L (mm)<br />

volume (µL) gastight needle needle dimension units<br />

5 – fixed 0.63 x 50 1 1 009970-001-00<br />

10 – fixed 0.63 x 50 1 009970-002-00<br />

25 fixed 0.63 x 50 1 009970-004-00<br />

100 replaceable 0.63 x 50 1 2 009970-005-00<br />

250 replaceable 0.63 x 50 1 009970-006-00<br />

2<br />

Spare<br />

needles for 100/250 µL syringe 2 009970-007-00<br />

Delivery times upon request *<br />

35


Part No.<br />

Microliter syringes<br />

For MPS 2, MPS 2L and MPS PrepStation, for use with the GERSTEL ®<br />

Universal liquid syringe adapter<br />

The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and are<br />

compatible with the GERSTEL Septumless Head (SLH). Needles have<br />

conical tips (type C or AS).<br />

needle dimensions<br />

volume (µL) gastight needle OD x L (mm) units Part No.<br />

1.2 – needle-in-needle 0.47 x 51.0 1 093611-010-00<br />

5 – fixed 0.63 x 51.7 1 009970-021-00<br />

10 – fixed 0.63 x 51.5 1 009970-024-00<br />

10 fixed 0.63 x 51.5 1 009970-022-00<br />

10 – fixed 0.47 x 51.5 1 009970-058-00<br />

5 – replaceable 0.63 x 51.5 1 009970-015-00<br />

10 replaceable 0.63 x 51.5 1 009970-016-00<br />

100 replaceable 0.63 x 52.0 1 009970-018-00<br />

250 replaceable 0.63 x 52.0 1 009970-019-00<br />

1000 replaceable 0.63 x 53.5 1 009970-020-00<br />

Replacement syringe plungers (gastight)<br />

10 µL syringe with fixed needle 1 009970-030-00<br />

10 µL syringe with replaceable needle 1 009970-031-00<br />

100 µL syringe with replaceable needle 1 009970-032-00<br />

250 µL syringe with replaceable needle 1 009970-033-00<br />

1000 µL syringe with replaceable needle 1 009970-034-00<br />

Replacement needles<br />

5 µL syringe with replaceable needle 2 009970-048-00<br />

10 µL syringe with replaceable needle 2 009970-040-00<br />

100/250 µL syringe with replaceable needle 2 009970-041-00<br />

1000 µL syringe with replaceable needle 2 009970-042-00<br />

On column needle<br />

10 µL syringe with replaceable needle 2 009970-043-00<br />

36


GERSTEL ® MultiPurpose Sampler, MPS<br />

Part No.<br />

Part No.<br />

Microliter syringe<br />

for MPS 2, MPS 2L, MPS 2XL and MPS PrepStation<br />

For use with GERSTEL ® Universal Headspace Syringe Adapter in<br />

combination with heated adapter for liquid injection.<br />

The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and are<br />

compatible with the GERSTEL Septumless Head (SLH). Needles have<br />

conical tips (type C or AS).<br />

needle dimensions<br />

volume (µL) gastight needle OD x L (mm) units Part No.<br />

10 – replaceable 0.63 x 54.2 1 009970-051-00<br />

10 – fixed 0.63 x 54.2 1 009970-057-00<br />

Replacement needle for<br />

10 µL syringe with needle 2 009970-052-00<br />

For use with the GERSTEL Universal Headspace Syringe<br />

Adapter<br />

The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and<br />

are compatible with the GERSTEL Septumless Head (SLH). Needles<br />

have conical tips (type H or 5).<br />

OD x L (mm)<br />

volume [mL] gastight needle needledimension units Part No.<br />

1 replaceable 0.63 x 57.0 1 009980-045-00<br />

2.5 replaceable 0.63 x 57.0 1 009980-044-00<br />

Replacement syringe plungers (gastight)<br />

1 mL headspace syringe 1 009980-047-00<br />

2.5 mL headspace syringe 1 009980-048-00<br />

Replacement needle<br />

1-/2.5 mL headspace syringe 2 009980-046-00<br />

37


Part No.<br />

Dilutor module for<br />

MPS 2, MPS 2 XL and MPS PrepStation<br />

MPS 2 Dilutor syringe<br />

For use with the MPS Dilutor module<br />

volume units Part No.<br />

MPS Dilutor syringe 1 mL 1 093631-091-00<br />

2.5 mL 1 093631-092-00<br />

5 mL 1 093631-093-00<br />

10 mL 1 093631-094-00<br />

Replacement plunger for MPS Dilutor syringe<br />

1 mL 1 093632-038-00<br />

2.5 mL 1 093632-039-00<br />

5 mL 1 093632-040-00<br />

10 mL 1 093632-041-00<br />

PTFE seal for MPS Dilutor syringe 1 093632-045-00 *<br />

Solvent bottle for MPS Dilutor; 1000 mL 1 093632-043-00 *<br />

*<br />

*<br />

*<br />

*<br />

MPS 2 Sideport syringe without needle<br />

For use with MPS sideport syringe adapter (not<br />

compatible with GERSTEL ® Universal Syringe Adapter)<br />

volume units Part No.<br />

MPS Sideport syringe<br />

without needle 20 µL 1 093631-096-00<br />

80 µL 1 093631-095-00<br />

Replacement plunger<br />

for Sideport syringe 20 µL 10 093611-034-00 *<br />

80 µL 10 093611-0<strong>27</strong>-00 *<br />

Needles<br />

Needles for use with MPS 2, MPS 2L, MPS XL and MPS PrepStation.<br />

For use with GC injectors.<br />

23s gauge (OD = 0.63 mm) needle for 20 µL syringe 3 093611-033-00<br />

26 gauge (OD = 0.47 mm) needle for 20 µL syringe 3 093611-029-00<br />

23 gauge (OD = 0.63 mm) needle for 80 µL syringe 3 093611-032-00<br />

26 gauge (OD = 0.47 mm) needle for 80 µL syringe 3 093611-028-00<br />

26 gauge needles are compatible with on-column injection.<br />

38<br />

Delivery times upon request *


GERSTEL ® MultiPurpose Sampler, MPS<br />

Part No.<br />

SPME fiber holder<br />

Designed for mounting SPME fibers for<br />

automated SPME analysis.<br />

093639-000-00<br />

Fibers used for automated SPME analysis have no spring<br />

– in contrast to fibers for manual SPME. Consequently,<br />

there are separate holders for each fiber type. The fibers<br />

listed here are designed exclusively for automated SPME<br />

analysis using the MPS 2. They are not suitable for manual<br />

SPME analysis.<br />

For use with the GERSTEL ® Cooled Injection System, CIS<br />

23 gauge (OD=0.63 mm) fibers and SPME liner are<br />

recommended.<br />

SPME fiber kits<br />

volatiles<br />

100 µm polydimethylsiloxane, non-bonded<br />

non-polar semivolatiles<br />

30 µm polydimethylsiloxane, non-bonded<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639 001-00<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-003-00<br />

non-polar high molecular weight compounds<br />

7 µm polydimethylsiloxane, bonded<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-004-00<br />

volatiles, amines, and nitroaromatic compounds<br />

65 µm polydimethylsiloxane/divinylbenzene,<br />

partially crosslinked<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-005-00<br />

volatiles, amines, and nitroaromatic compounds<br />

65 µm polydimethylsiloxane/divinylbenzene,<br />

highly crosslinked on StableFlex fiber<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-022-00<br />

semivolatiles<br />

85 µm polyacrylate, partially crosslinked<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-023-00<br />

39


Part No.<br />

SPME fiber kits<br />

gases and low molecular compounds<br />

75 µm carboxen/polydimethylsiloxane,<br />

partially crosslinked<br />

gases and low molecular compounds<br />

85 µm carboxen/polydimethylsiloxane,<br />

highly crosslinked on StableFlexTM fiber<br />

alcohols and polar compounds<br />

65 µm carbowax/divinylbenzene,<br />

partially crosslinked<br />

alcohols and polar compounds<br />

70 µm carbowax/divinylbenzene,<br />

highly crosslinked on StableFlexTM fiber<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-009-00<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-024-00<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-025-00<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-013-00<br />

volatiles and semivolatiles<br />

85 µm polyacrylate, 100 µm polydimethylsiloxane,<br />

7 µm polydimethylsiloxane coating<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-028-00<br />

flavors<br />

50/30 µm divinylbenzene/carboxen/<br />

polydimethylsiloxane on StableFlex fiber<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-026-00<br />

flavors<br />

50/30 µm divinylbenzene/carboxen/<br />

polydimethylsiloxane on 2 cm StableFlex fiber 23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-0<strong>27</strong>-00<br />

volatile or polar organics in water<br />

75 µm carboxen/polydimethylsiloxane,<br />

65 µm polydimethylsiloxane/divinylbenzene,<br />

65 µm carbowax/divinylbenzene<br />

flavors and odors<br />

100 µm polydimethylsiloxane,<br />

65 µm polydimethylsiloxane/divinylbenzene,<br />

65 µm carboxen/polydimethylsiloxane<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-029-00<br />

23 gauge (OD=0.63 mm)<br />

1 package (3 units) 093639-030-00<br />

40


GERSTEL ® MultiPurpose Sampler, MPS<br />

Part No.<br />

SPME Stableflex fiber kit<br />

23 gauge (OD = 0.63 mm), 4 fibers<br />

50/30 Divinylbenzene/Carboxen<br />

65 µm Polydimethylsiloxane/Divinylbenzene<br />

85 µm Carboxen/Polydimethylsiloxane<br />

70 µm Carbowax/Divinylbenze 093639-031-00<br />

Sample trays<br />

for 200 vials 0.7/1 mL (VT 200) 093631-007-00 *<br />

for 98 vials 2 mL ( VT 98) 093631-008-00 *<br />

for 32 vials 10/20 mL ( VT 32) 093631-009-00 *<br />

for 54 vials 2 mL for stack (VT 54) 093631-010-00 *<br />

for 54 vials 2 mL for stack, 6 units (VT 54) 093631-086-00 *<br />

Adapter plate to use a microtiter or deepwell plate in cooled trays<br />

093631-084-00 *<br />

Plastic tray cover<br />

for 1 mL vials in Tray 093631-068-00 *<br />

for 2 mL vials in Tray 093631-069-00 *<br />

for deepwell or microtiter plates in cooled trays 093631-080-00 *<br />

Inserts for 2 mL vials for agitator<br />

1 package (6 units)<br />

For use with 2 mL vials in combination<br />

with the MPS 2 agitator e.g. for Twister ® Back Extraction.<br />

093631-002-00 *<br />

Delivery times upon request *<br />

41


GERSTEL ® MultiPurpose Sampler, MPS 3<br />

Part No.<br />

MPS 3/3C/3LC are programmable XYZ<br />

autosamplers and sample preparation<br />

robots for liquid chromatography and<br />

LC/MS. The MPS can automate<br />

everything from sample preparation to<br />

sample introduction.<br />

The MPS 3 and MPS 3C are specially<br />

designed for High Throughput Screening,<br />

HTS. The MPS 3LC is a HPLC<br />

autosampler with fixed configuration.<br />

These systems set the standard for speed,<br />

reliability, accuracy and throughput.<br />

GERSTEL MASter Software enables<br />

integrated control of the MPS 3 and a<br />

LC or LC/MS system. One method and<br />

one integrated sequence controls the<br />

complete system through the Agilent ®<br />

Technologies ChemStation Software.<br />

GERSTEL MASter software is fully<br />

integrated into the ChemStation software:<br />

All sample parameters are saved as<br />

part of ChemStation methods. A single<br />

sequence table ties together all sample<br />

information, autosampler functions,<br />

and data file functions. The GERSTEL<br />

PrepBuilder Software enables overlapping<br />

sample preparation and GC analysis.<br />

While LC separation is in progress,<br />

the next sample is being prepared for<br />

analysis, ensuring maximum productivity.<br />

Automated sample preparation<br />

steps include:<br />

• Standard addition<br />

• Derivatization<br />

• Dilution<br />

• Liquid-liquid extraction<br />

• Twister ® Back Extraction<br />

• Membrane Assisted Solvent Extraction<br />

• Heating<br />

• Rinsing<br />

• Agitation<br />

MPS 3LC<br />

MPS 3<br />

42


GERSTEL ® MultiPurpose Sampler, MPS 3<br />

Part No.<br />

Part No.<br />

Vials and caps for use with MPS 3, MPS 3C and MPS 3LC<br />

sampler description volume units Part No.<br />

MPS 3<br />

Crimp cap vials<br />

Crimp cap vial, clear, for 8 mm caps 0.7 mL 100 093640-052-00<br />

Crimp cap vial, clear, for 11 mm caps 2 mL 100 093640-004-00<br />

*<br />

Crimp caps<br />

Crimp cap, Aluminium with septum,<br />

PTFE red / Silicone / PTFE red , for 8 mm vials 0.7 mL 100 093640-053-00<br />

Crimp cap, magnetic, golden with septum,<br />

PTFE red / Silicone / PTFE red, for 11 mm vials 2 mL 100 093640-007-00<br />

Screw cap vials incl. caps and septa<br />

Screw cap vial, clear, incl.<br />

11 mm cap with septum 2 mL 100 089355-076-00<br />

Microliter inserts for 2 mL Screw cap vials<br />

Inert, clear 100 µL 100 093640-029-00<br />

Screw cap vials for Twister ® Back Extraction<br />

for use with 10 mm Twisters<br />

Screw cap vial 32 x 11.6 mm, clear,<br />

for 11 mm screw cap 1.5 mL 100 093640-046-00<br />

Insert 31 x 6 mm, clear, flat bottom 0.2 mL 100 093640-047-00<br />

for use with 20 mm Twisters<br />

Screw cap vial 32 x 11.6 mm, clear,<br />

for 11 mm screw cap 1.1 mL 100 093640-045-00<br />

Screw cap 9 mm with magnetic disks,<br />

blue, with septum, Silicone white / PTFE red,<br />

1.0 mm, 55° shore A 100 093640-048-00<br />

Solvent bottle 100 mL<br />

incl. cap and septum<br />

*<br />

Caps and septa<br />

for 100 mL solvent bottle<br />

093631-054-00<br />

1 package (10 units) 093631-055-00<br />

Wash solvent bottle<br />

for fast wash station<br />

500 mL 093731-018-00 *<br />

1000 mL 093731-115-00<br />

Delivery times upon request *<br />

43


Part No.<br />

Crimper<br />

for 8 mm crimp vials (0.7 mL vials) 093640-054-00 *<br />

for 11 mm crimp vials (2 mL vials) 093640-000-00<br />

Decapper<br />

for 8 mm crimp vials (0.7 mL vials) 093640-055-00<br />

for 11 mm crimp vials (2 mL vials) 093640-002-00<br />

*<br />

Syringe kits<br />

with syringe detect, consisting of: plunger holder,<br />

syringe adapter and 2 syringes<br />

10 µL 093711-007-00<br />

25 µL 093711-008-00<br />

100 µL 093711-009-00<br />

250 µL 093711-010-00<br />

1000 µL 093711-011-00<br />

2500 µL 093711-012-00<br />

5000 µL 093711-013-00<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

Replacement syringe plunger units<br />

10 µL , gastight 10 093611-026-00<br />

25 µL 10 093611-020-00<br />

100 µL 10 093611-021-00<br />

250 µL 10 093611-022-00<br />

500 µL 1 093711-026-00<br />

1000 µL 1 093711-019-00<br />

2500 µL 1 093711-020-00<br />

5000 µL 1 093711-021-00<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

44<br />

Delivery times upon request *


GERSTEL ® MultiPurpose Sampler, MPS 3<br />

Part No.<br />

Part No.<br />

Microliter syringes for MPS 3, MPS 3C and MPS 3LC<br />

The needle types 22 and 22S both have the same outer diameter: 0.72 mm OD and a straight<br />

needle tip (Type LC or 3). Type 22 and 22S differ only by their internal diameter ( 0.41 mm and<br />

0.15 mm ID respectively); Due to the larger ID, a type 22 needle enables faster syringe filling: Up<br />

to 200 µL/sec for type 22 as opposed to 10 – 20 µL/sec for the 22S.<br />

volume (µL) gastight needle gauge point style units Part No.<br />

10 – fixed 22S 3 1 093711-000-00<br />

10 fixed 22S 3 1 093711-014-00<br />

25 fixed 22S 3 1 093711-001-00<br />

100 fixed 22S 3 1 093711-002-00<br />

100 fixed 22 3 1 093711-028-00<br />

250 fixed 22 3 1 093711-003-00<br />

500 fixed 22 3 1 093711-0<strong>27</strong>-00<br />

1000 fixed 22 3 1 093711-004-00<br />

2500 fixed 22 3 1 093711-005-00<br />

5000 fixed 22 3 1 093711-006-00<br />

The long-life Microliter syringes are much more durable than standard syringes.<br />

This is particularly useful for high-pressure work or when a large number of washcycles<br />

are used per sample.<br />

Long-life syringe kits<br />

Each kit contains a syringe holder, a syringe adapter with syringe type detection and two syringes.<br />

volume (µL) gastight needle gauge point style Part No.<br />

25 fixed 22S 3 093711-040-00<br />

100 fixed 22S 3 093711-041-00<br />

Special long life microliter syringes<br />

volume (µL) gastight needle gauge point style units Part No.<br />

25 fixed 22S 3 1 093711-038-00<br />

100 fixed 22S 3 1 093711-039-00<br />

X-type microliter syringes for LC<br />

For use with original CTC syringe adapters. X-type syringes provide extremely low carry-over as well as very<br />

long life-expectancy.<br />

volume (µL) gastight needle gauge point style units Part No.<br />

25 fixed 22S 3 1 093711-042-00<br />

100 fixed 22S 3 1 093711-043-00<br />

100 fixed 22 3 1 093711-044-00<br />

45


Part No.<br />

Dilutor module<br />

for MPS 3, MPS 3C and MPS 3LC<br />

MPS Dilutor syringe<br />

for MPS 3, MPS 3C and MPS 3LC<br />

volume units Part No.<br />

MPS dilutor syringe 1 mL 1 093631-091-00<br />

2.5 mL 1 093631-092-00<br />

5 mL 1 093631-093-00<br />

10 mL 1 093631-094-00<br />

Replacement<br />

syringe plunger 1 mL 1 093632-038-00 *<br />

for MPS 2.5 mL 1 093632-039-00 *<br />

dilutor syringe 5 mL 1 093632-040-00 *<br />

10 mL 1 093632-041-00 *<br />

PTFE ferrule for MPS dilutor syringe 1 093632-045-00 *<br />

Dilutor solvent bottle 1000 mL 1 093632-043-00 *<br />

MPS sideport syringe without needle<br />

For use with MPS sideport-syringe adapter (not<br />

compatible with GERSTEL ® Universal Syringe Adapter)<br />

volume units Part No.<br />

MPS sideport syringe 20 µL 1 093631-096-00<br />

80 µL 1 093631-095-00<br />

Replacement plunger<br />

for sideport syringes 20 µL 10 093611-034-00<br />

80 µL 10 093611-0<strong>27</strong>-00<br />

Replacement needles for MPS sideport syringes<br />

for use with MPS 3 and MPS 3C,<br />

for use with LC injection valves<br />

22 gauge (OD = 0.72mm) needle for 20 µL syringe 3 093711-023-00<br />

22 gauge (OD = 0.72 mm) needle for 80 µL syringe 3 093711-022-00<br />

*<br />

*<br />

46<br />

Delivery times upon request *


GERSTEL ® MultiPurpose Sampler, MPS 3<br />

Part No.<br />

Sample loops<br />

for VICI HPLC-valve 1/16“;<br />

includes nuts and ferrules<br />

1<br />

2<br />

3<br />

2 µL 093731-049-00<br />

20 µL 093731-011-00 *<br />

50 µL 093731-010-00 *<br />

100 µL 093731-009-00 *<br />

500 µL 093731-008-00 *<br />

1000 µL 093731-007-00 *<br />

1<br />

for VICI HPLC-valve,<br />

Typ DC6WK and DC10WK;<br />

includes nuts and ferrules<br />

200 µL 093731-070-00 *<br />

250 µL 093731-055-00 *<br />

MPS 3<br />

2 µL 093731-049-00<br />

5 µL 093731-050-00<br />

10 µL 093731-051-00<br />

15 µL 093731-052-00<br />

25 µL 093731-053-00<br />

30 µL 093731-054-00<br />

2<br />

for Cheminert Injection-valve<br />

20 µL 093731-034-00<br />

50 µL 093731-033-00<br />

100 µL 093731-032-00<br />

250 µL 093731-031-00<br />

500 µL 093731-030-00<br />

3<br />

Sample trays<br />

for 200 x 0.7/1 mL vials (VT 200) 093631-007-00 *<br />

for 98 x 2 mL vials (VT 98) 093631-008-00 *<br />

for 32 x 10/20 mL vials (VT 32) 093631-009-00 *<br />

for 54 x 2 mL vials for stack (VT 54) 093631-010-00 *<br />

for 54 x 2 mL vials for stack, pack with 6 units (VT 54) 093631-086-00 *<br />

Adapter plate to use a microtiter-<br />

or a deepwell plate in cooled trays 093631-084-00<br />

Plastic tray cover<br />

for 1 mL vials tray 093631-068-00 *<br />

for 2 mL vials tray 093631-069-00 *<br />

for deepwell or microtiter plates in cooled trays 093631-080-00 *<br />

Delivery times upon request *<br />

47


GERSTEL ® Twister Desorption Unit, TDU<br />

Part No.<br />

The GERSTEL ® Twister ® Desorption Unit is a<br />

thermal desorption accessory designed for<br />

use with the GERSTEL Twister. The TDU is<br />

based on the same technology as the proven<br />

GERSTEL Thermal Desorption System, TDS, but<br />

is optimized for desorption of Twisters stir bars.<br />

In combination with the GERSTEL MultiPurpose<br />

Sampler, MPS 2, automated analysis of up<br />

to 196 Twisters can be performed in a single<br />

sequence.<br />

Recommended Kit<br />

consists of:<br />

– Glass inserts kit<br />

– O ring kit for transportation adapters (100 units)<br />

– Twister transportation adapters (10 units)<br />

– GRAPHPACK-3D ferrules (10 units)<br />

– Twisters, film thickness 0.5 mm, length 10 mm (10 units)<br />

– GERSTEL-Twister desorption Liner (100 units)<br />

system<br />

Part No.<br />

TDU / CIS 3 01<strong>27</strong>13-003-00<br />

TDU / CIS 4 01<strong>27</strong>13-004-00<br />

48


GERSTEL ® Twister Desorption Unit, TDU<br />

Part No.<br />

Transportation adapter for<br />

GERSTEL ® Twister ® desorption liner<br />

1 package (10 units) 012423-010-00<br />

1 package (100 units) 012423-100-00<br />

Transportation adapter for liquid<br />

injection<br />

1 package (10 units) 013645-010-00<br />

O-ring set for transportation<br />

adapter<br />

1 package (10 Sets) 012424-010-00<br />

1 package (100 Sets) 012424-100-00<br />

Twister desorption liner<br />

1 package (100 units) 013010-100-00<br />

Glass inserts for Twister sample tray<br />

1 package (100 units) 012565-100-00<br />

O-ring for glass inserts<br />

for Twister sample tray<br />

1 package (10 units) 013032-010-00<br />

1 package (100 units) 013032-100-00<br />

49


Part No.<br />

Glass liners for CIS 3/4 in combination with TDU<br />

Part No.<br />

Part No.<br />

packing deactivated description/use units CIS 3/3 S CIS 4<br />

silanized 1 mm ID, straight 10 – 013409-010-00<br />

glass wool<br />

standard glass liner<br />

empty straight with notch 10 013776-010-00 013775-010-00<br />

Initial system checkout; user custom-packed<br />

liners; hot split/splitless injections<br />

empty baffled 10 012441-010-00 012436-010-00<br />

General use liquid injection for<br />

moderate/high boilers, labile compounds,<br />

split injections<br />

empty 2 mm ID 10 – 013911-010-00<br />

For special applications<br />

silanized General use liquid injection for 10 01<strong>27</strong>41-010-00 01<strong>27</strong>42-010-00<br />

glass wool<br />

moderate/high boilers, stable compounds;<br />

glass wool<br />

thermal desorption cryotrapping<br />

of stable compounds<br />

quartz wool More inert than glass wool; used for trapping 10 012442-010-00 012437-010-00<br />

labile compounds<br />

Tenax TA Elimination of water (40°C most effective); 10 012443-010-00 012438-010-00<br />

Trapping of C 5 and higher volatiles<br />

(-50°C minimum temperature)<br />

Carbotrap B Trapping of low boiling volatiles 10 012444-010-00 012439-010-00<br />

Glass liner kit CIS/TDU<br />

Part No.<br />

Part No.<br />

included glass liners units (each) units (each) CIS 3 CIS 4<br />

CIS 3 CIS 4<br />

empty (baffled) 2 2 012440-003-00 012440-004-00<br />

packed with silanized glass wool 4 2<br />

packed with Tenax TA 2 2<br />

packed with Carbopack B 2 2<br />

1 mm ID, packed with<br />

silanized glass wool – 2<br />

Note<br />

The CIS glass liners listed in the above tables are designed for use only in combination with<br />

a TDU. For all other analyses using a CIS use only the inlet liners listed on page 24.<br />

50


GERSTEL ® Twister Desorption Unit, TDU<br />

Part No.<br />

GRAPHPACK ® 3D ferrules for glass liners<br />

1 package (5/10 units)<br />

Part No.<br />

Part No.<br />

units CIS 3 CIS 4/CIS 6 *<br />

5 002426-005-00 007541-005-00<br />

10 002426-010-00 007541-010-00<br />

Mica coated for improved sealing<br />

Part No.<br />

Part No.<br />

units CIS 3 CIS 4/CIS 6 *<br />

5 002426-105-00 -<br />

10 002426-110-00 -<br />

GRAPHPACK 3D mounting<br />

tool for glass liners<br />

Note<br />

The GRAPHPACK 3D mounting tool is<br />

designed for use only with glass liners used<br />

in combination with a TDU. (see page 50)<br />

TDU/CIS 3 01<strong>27</strong>81-003-00<br />

TDU/CIS 4 01<strong>27</strong>81-004-00<br />

Septum for transportation<br />

adapter for liquid injection<br />

1 package (100 units) 014052-100-00<br />

Allen wrench for transportation<br />

adapter screws, 5 mm<br />

009999-205-00<br />

51


Part No.<br />

GERSTEL Twister ®<br />

The GERSTEL ® Twister ® looks just like a conventional<br />

magnetic stir bar, except for the polydimethylsiloxane<br />

(PDMS) coating. While stirring the aqueous or polar<br />

liquid sample, the Twister efficiently extracts organic<br />

compounds into the PDMS phase. After stirring, the<br />

Twister is transferred to a GERSTEL Thermal Desorption<br />

System. Thermal desorption ensures efficient and<br />

quantitative transfer of analytes to the GC column and<br />

lowest detection limits. Thermally labile analytes can<br />

be desorbed using a liquid solvent for subsequent LC<br />

determination – or for Large Volume Injection GC. Due<br />

to the large volume of PDMS on the Twister and due to<br />

the stirring effiency, it provides much greater capacity<br />

and much lower detection limits than SPME.<br />

Part No.<br />

Book »New Concepts in Sorption Based<br />

Sample Preparation for Chromatography«<br />

by H.A. Baltussen, 241 pages<br />

013745-000-00<br />

GERSTEL Twister ®<br />

for Stir Bar Sorptive Extraction (SBSE)<br />

with polydimethylsiloxane phase (PDMS)<br />

film thickness 0.5 mm,<br />

length 10 mm<br />

10 units 011222-001-00<br />

100 units 011222-002-00<br />

film thickness 1 mm,<br />

length 10 mm<br />

10 units 011333-001-00<br />

100 units 011333-002-00<br />

film thickness 0.5 mm,<br />

length 20 mm<br />

10 units 011444-001-00<br />

100 units 011444-002-00<br />

film thickness 1 mm,<br />

length 20 mm<br />

10 units 011555-001-00<br />

100 units 011555-002-00<br />

52


GERSTEL ® Twister ® 53<br />

Part No.<br />

GERSTEL ® Twister ® kit<br />

Set of Twisters for Stir Bar Sorptive Extraction (SBSE) with<br />

polydimenthylsiloxane (PDMS) phase.<br />

film thickness 0.5 mm, 10 mm length (4 units)<br />

film thickness 1.0 mm, 10 mm length (2 units)<br />

film thickness 0.5 mm, 20 mm length (2 units)<br />

film thickness 1.0 mm, 20 mm length (2 units)<br />

012370-000-00<br />

Desorption tubes for use with TDS,<br />

TDS A2 or Tube Conditioner, TC 1/2<br />

for Twisters with film thickness up to 1 mm,<br />

tube 6 mm OD, 4.5 mm ID, 1 package (10 units)<br />

012518-010-00<br />

Forceps<br />

009999-025-00<br />

Vials<br />

1<br />

2 mL vial<br />

with screw cap and septum,<br />

1 package (100 units) 089355-076-00<br />

1<br />

3<br />

2<br />

3<br />

10 mL vial<br />

1 package (100 units) 093640-005-00<br />

20 mL vial<br />

1 package (100 units) 093640-006-00<br />

2


Part No.<br />

Twister ® Headspace Sorptive Extraction (HSSE),<br />

analyte extraction and concentration from the vapor<br />

phase using the GERSTEL ® Twister.<br />

HSSE is a concentration technique that is much more<br />

sensitive than traditional static headspace analysis.<br />

A Twister is placed in an open adapter inside a closed<br />

headspace vial. The Twister is placed in the vapor<br />

phase above the sample such that analytes are<br />

extracted by, and concentrated into, the PDMS phase<br />

of the Twister. Sorptive extraction and concentration<br />

of organic compounds provides lower detection limits<br />

when combined with a GERSTEL TDS or TDU system<br />

for thermal desorption GC or GC/MS analysis.<br />

TWISTER headspace vials 20 mL<br />

1 package (100 units)<br />

012491-000-00<br />

Inserts for 20 mL Twister headspace vials 20 mL<br />

1 package (100 units)<br />

012492-000-00<br />

Crimp caps<br />

for 10/20 mL vial (100 units)<br />

089280-009-00 *<br />

Septa<br />

for 10/20 mL vial (100 units)<br />

089280-010-00<br />

*<br />

54<br />

Delivery times upon request *


GERSTEL ® Twister ® 55<br />

Part No.<br />

Twister ® Back Extraction Option<br />

for the MPS 3<br />

consists of:<br />

– 1.5 mL vials with caps and 200 µL inserts (100 units<br />

– Opening lock for the Agitator (1 unit)<br />

– Twister Back Extraction sequence software (1 unit)<br />

Requires, but does not include, GERSTEL ® MPS 3<br />

with GERSTEL MASter software.<br />

012195-099-00<br />

Crimper<br />

for 20 mm crimp caps (10/20 mL vials)<br />

093640-001-00<br />

Decapper<br />

for 20 mm crimp caps (10/20 mL vials)<br />

093640-003-00<br />

Mechanical crimper<br />

for 20 mm crimp caps<br />

Spare parts<br />

see page 35<br />

093640-009-00


GERSTEL ® Thermal Desorption System, TDS<br />

Part No.<br />

The GERSTEL ® Thermal Desorption System,<br />

TDS 3 is a highly optimized system for<br />

thermal desorption of Volatile Organic<br />

Compounds (VOCs) and Semi-Volatile<br />

Organic Compounds (SVOCs) followed by<br />

cryofocusing and GC analysis.<br />

Thermal desorption is a powerful concentration<br />

technique providing extremely<br />

low limits of detection. VOCs and SVOCs<br />

from gas-phase samples are trapped and<br />

concentrated on an adsorbent bed in a TDS<br />

tube by pumping a volume of the gas-phase<br />

sample through the tube. Solid and liquid<br />

samples can be placed in the TDS tube<br />

for direct thermal extraction or dynamic<br />

headspace of VOCs and SVOCs.<br />

In the TDS 3, analytes are thermally<br />

desorbed from the TDS tube using<br />

heat and a controlled flow of inert gas.<br />

Following primary desorption, analytes are<br />

concentrated on a second and smaller trap<br />

prior to GC or GC/MS determination.<br />

The GERSTEL Cooled Injection System,<br />

CIS functions as a cryotrap for the TDS 3,<br />

focusing and concentrating the compounds<br />

to be determined, and then transferring<br />

them to the capillary column in a narrow<br />

band for optimal GC separation using rapid,<br />

programmed heating.<br />

With the addition of the TDS A the TDS 3<br />

becomes a fully automated thermal<br />

desorption system capable of unattended,<br />

automated analysis of up to 20 samples. A<br />

separate TDS system, the TDS G on-line, is<br />

designed for continuous on-line analysis of<br />

VOCs and SVOCs in air and gas streams.<br />

TDS A2<br />

TDS 3<br />

TDS G<br />

56


GERSTEL ® TDS family<br />

Part No.<br />

TDS tube adapter for<br />

GERSTEL ® TDS 3<br />

Allows 1/4” OD x 3.5“ L<br />

desorption tubes to be used with the<br />

TDS 3 (stainless steel tubes only)<br />

Vespel cone<br />

Vespel cone for TDS Tube adapter<br />

1 unit 014454-000-00<br />

1 set (21 units) 014454-021-00<br />

1 package (5 units) 014456-005-00<br />

Screw driver SW 1.5<br />

for TDS tube adapter<br />

013329-000-00<br />

Spare parts for TDS 2/3 septum<br />

head for liquid injection<br />

Special needle<br />

for 10 µl syringe, length 115 mm<br />

1 package (5 units) 009970-059-00<br />

Ice blue septa<br />

5 mm<br />

1 package (100 units) 014052-100-00<br />

SLH adapter<br />

for spiking TDS tubes<br />

CIS 3 008871-003-00<br />

CIS 4/6 008871-003-00<br />

Special needle<br />

for 10 µl syringe, length 81 mm<br />

009970-016-00<br />

1 package (2 units) 009970-049-00<br />

Supply kit for TDS 2/3<br />

calibration adapter<br />

includes 5 glass tubes with<br />

GP 3D ferrules and 5 teflon ferrules<br />

SLH / CIS 3 010454-003-00<br />

SLH / CIS 4 010454-004-00<br />

57


Part No.<br />

1<br />

Desorption tubes<br />

6 mm OD, for use with all GERSTEL TDS systems.<br />

Each tube has a unique serial number for identification and traceability.<br />

2<br />

4<br />

3<br />

5<br />

packing conditioned description units Part No.<br />

1<br />

2<br />

Tenax TA 60/80<br />

Tenax GR<br />

–<br />

–<br />

glass tube<br />

glass tube<br />

5<br />

5<br />

012260-005-00<br />

012<strong>27</strong>5-005-00<br />

3 Chromosorb 106 – glass tube 5 012<strong>27</strong>6-005-00<br />

4 Carbosieve – glass tube 5 012<strong>27</strong>7-005-00<br />

Carbotrap 300 – multibed, glass tube 5 012346-005-00<br />

Carbotrap 300 – multibed, glass tube 1 012347-005-00<br />

Tenax TA 60/80 – 1<br />

Tenax GR – 1<br />

Chromosorb 106 – 1<br />

Carbosieve – 1<br />

Carbotrap B 100 mg 1 012458-000-00<br />

Carbotrap C 200 mg<br />

Tenax TA 60/80 in storage container, glass tube 1 009947-000-00<br />

Tenax TA 60/80 in storage container, SS tube 1 010040-000-00<br />

Tenax GR in storage container, glass tube 1 009948-000-00<br />

Tenax GR in storage container, SS tube 1 010041-000-00<br />

Carbosieve in storage container, glass tube 1 009949-000-00<br />

Carbosieve in storage container, SS tube 1 010042-000-00<br />

Carbotrap 300 in storage container, glass tube 1 008357-000-00<br />

Carbotrap 300 in storage container, SS tube 1 010044-000-00<br />

Carbotrap 349 in storage container, glass tube 1 009117-000-00<br />

Carbotrap 217 in storage container, glass tube 1 013115-000-00<br />

5 Tenax / Carboxene – in storage container, glass tube 1 009118-000-00<br />

empty – glass tube 10 010649-010-00<br />

6 empty – glass tube 1 010649-000-00<br />

7 empty – glass tube with glass frit 1 010650-000-00<br />

empty – glass tube with glass frit 10 010650-010-00<br />

6<br />

7<br />

58


GERSTEL ® TDS family<br />

Part No.<br />

GERSTEL ® TDS adsorbent overview<br />

Graphitized Carbon Blacks<br />

Carbotrap/Carbopack Unlike activated charcoals, which<br />

are porous, graphitized carbon blacks (GCBs), such as<br />

Carbotrap and Carbopack, are generally non-porous.<br />

Consequently, the entire surface of these materials is<br />

available for interactions that depend solely on dispersion<br />

(London) forces. These adsorbents offer excellent thermal<br />

stability, which ensures minimal bleed at thermal desorption<br />

temperatures, and their coarse 20/40 and 40/60 mesh particle<br />

size prevents high pressure drop across the tube. Hydrophobic<br />

properties minimize sample displacement by water, enabling<br />

you to obtain accurate samples despite high humidity. Trapped<br />

compounds can be desorbed by solvent or thermal desorption<br />

at virtually 100% desorption efficiency.<br />

Carbopack B is essentially the same adsorbent as Carbotrap;<br />

the only difference is the mesh size (60/80 mesh for Carbopack B<br />

vs. 20/40 mesh for Carbotrap). Both have a specific surface area<br />

of 100 m 2 /g. Carbopack B is often used in narrow bore tubes (1-2<br />

mm ID), for sample refocusing or for very low flow sampling (e.g.,<br />


Part No.<br />

Sorption tubes<br />

1<br />

packing conditioned description units Part No.<br />

PDMS – 1<br />

6 mm OD, glass tube, 1 009171-000-00<br />

for gaseous samples<br />

2<br />

<strong>Supplies</strong> for desorption tubes<br />

OD description units Part No.<br />

3<br />

Storage Container 6 mm 2<br />

single 1 008351-000-00<br />

End cap set 6 mm 3<br />

stainless steel, with PTFE seals 1 008235-060-00<br />

End caps 6 mm stainless steel, with PTFE seals 10 012659-010-00<br />

Storage end caps 1/4 “ 3.5 “ long, brass 20 011754-020-00<br />

TDS empty tubes 1/4 “ 3.5 “ long, stainless steel 1 011619-000-00<br />

Diffusion caps 1/4 “ 3.5 “ long, stainless steel 10 011620-010-00<br />

for TDS tubes<br />

Screens 4<br />

10 008980-010-00<br />

4<br />

Tweezer for handling TDS tubes<br />

009970-050-00<br />

O-rings for TDS A<br />

sample magazine<br />

1 package (10 units)<br />

008174-010-00<br />

Sealing plugs for TDS A/A2<br />

sample magazine<br />

1 package (10 units)<br />

014173-010-00<br />

60


GERSTEL ® TDS family<br />

Part No.<br />

Spare parts for TDS 2/3<br />

locking cone<br />

O-ring set<br />

for TDS 2/3 locking cone manual<br />

007884-000-00<br />

Inner O-ring<br />

for TDS 2/3-TDS A/A2 locking cone,<br />

1 package (5 units)<br />

009095-005-00<br />

Fixing nut for inner O-ring<br />

for TDS 2/3 locking cone<br />

009013-001-00<br />

Spare parts for TDS A/A2 locking cone<br />

1<br />

1<br />

Service kit for TDS A/A2 locking cone 010441-000-00<br />

2<br />

3<br />

Fixing nut for inner O-ring<br />

for TDS A locking cone 009013-000-00<br />

Inner O-ring for TDS 2/3/TDS A/A2 locking cone<br />

1 package (5 units) 009095-005-00<br />

2<br />

3<br />

4<br />

Spindel O-ring<br />

1 package (5 units) 010372-005-00<br />

5<br />

Spindel safety catch<br />

1 package (5 units) 011061-005-00<br />

4<br />

5<br />

61


Part No.<br />

Direct interface<br />

for 0.7 mm OD transfer line<br />

System for transfer line OD units<br />

TDS 2/3 with CIS 3 0.70 mm 1 007823-007-00<br />

TDS 2/3 with CIS 4 0.70 mm 1 008311-007-00<br />

TDS 2/3 – TDS G with CIS 3s 0.70 mm 1 011025-007-00<br />

TDS 2/3 with CIS 3s Tremetics 0.70 mm 1 011628-007-00<br />

Transfer lines<br />

for TDS 2/3 with CIS 3/CIS 4, length 5 m<br />

Version deactivated OD/ID<br />

ProSteel ® 0.67 mm/0.53 mm 008687-005-00<br />

Silcosteel ® 0.74 mm/0.45 mm 010963-005-00<br />

Sulfinert ® 0.74 mm/0.45 mm 012185-005-00<br />

Transfer line kit<br />

for TDS 2/3 with CIS 3/CIS 4, length 1 m<br />

Version deactivated OD units<br />

ProSteel ® 0.67 mm 1<br />

GRAPHPACK ® 2M ferrule 10 011004-000-00<br />

Silcosteel ® 0.74 mm 1<br />

GRAPHPACK 2M ferrule 10 011005-000-00<br />

Sulfinert 0.74 mm 1<br />

GRAPHPACK 2M ferrule 10 012186-000-00<br />

Direct interface<br />

for 0.45 mm OD transfer line<br />

System OD units<br />

TDS 2/3 with CIS 3 0.45 mm 1 007823-045-00<br />

TDS 2/3 with CIS 4 0.45 mm 1 008311-045-00<br />

TDS 2/3 – TDS G with CIS 3s 0.45 mm 1 011025-045-00<br />

TDS 2/3 with CIS 3s Tremetics 0.45 mm 1 011628-045-00<br />

Transfer line<br />

for TDS 2/3 with CIS 3/CIS 4, length 5 m<br />

Version deactivated OD<br />

Fused Silica 0.45 mm 005014-005-00<br />

Transfer line kit<br />

for TDS 2/3 with CIS 3/CIS 4, length 1 m<br />

Version deactivated OD units<br />

Fused Silica 0.45 mm 1<br />

GRAPHPACK 2M ferrule 10 011003-000-00<br />

62


GERSTEL ® TDS family<br />

Part No.<br />

GRAPHPACK ® 2M adapter<br />

for TDS 2/3, for 0.45 mm OD transfer line 007820-045-00<br />

for TDS 2/3 and TDS G, for 0.7 mm OD transfer line 007820-007-00<br />

Silver seal<br />

for GRAPHPACK 2M adapter<br />

for TDS 2/3 and TDS G<br />

1 package (5 units) 007821-005-00<br />

Spare parts for TDS G<br />

GRAPHPACK Micro screw<br />

single, 0.70 mm<br />

007910-007-00<br />

GRAPHPACK Micro ferrule<br />

0.70 mm; 1 package (10 units)<br />

001905-007-00<br />

Adapter for GRAPHPACK Micro screw<br />

in conjunction with Valco Vici valve 1/16”<br />

008688-007-00<br />

GRAPHPACK 2M injector adapter<br />

for Valco Vici valve, 1/16"<br />

008019-045-00<br />

63


GERSTEL ® Pyrolysis Module, PM 1<br />

Part No.<br />

Manual Pyrolysis module for the TDS.<br />

Part No.<br />

Sample tubes<br />

for GERSTEL ® Pyrolysis Module PM1<br />

1 package (10 units) 009250-010-00<br />

1 package (50 units) 009250-050-00<br />

64


GERSTEL ® Pyrolysis module, PM 1<br />

Part No.<br />

Pyrolysis TDS tube<br />

for GERSTEL ® Pyrolysis Module,<br />

6.0 mm OD; 5.0 mm ID<br />

Note<br />

for use with Pyrolysis<br />

Module only<br />

Quartz glass<br />

1 units 009553-100-00<br />

Borosilicate glass<br />

10 units 009553-010-00<br />

Spare parts<br />

O-ring set for TDS 2/3<br />

manual locking cone<br />

007884-000-00<br />

Inner O-ring for<br />

TDS 2/3 locking cone<br />

1 package (5 units)<br />

009095-005-00<br />

Fixing nut for inner O-ring<br />

for TDS A/A2 locking cone<br />

009013-000-00<br />

65


Part No.<br />

GERSTEL ®<br />

Thermal Extractor, TE 1/2<br />

The GERSTEL Thermal Extractor TE 2 enables the analyst<br />

to extract volatile and semi-volatile organic compounds<br />

from liquid or solid samples, trapping the compounds on<br />

a TDS tube for further analysis. For aldehyde analysis,<br />

analytes can be trapped on a DNPH tube for subsequent<br />

liquid elution and LC analysis. The GERSTEL TE 2 has a<br />

larger inner diameter than normal TDS tubes. Larger sample<br />

volumes can be analyzed to obtain lower detection limits.<br />

A larger, more representative sample volume also ensures<br />

better results when analyzing inhomogenous samples.<br />

The GERSTEL TE 2 is completely independent of the TDS<br />

system, eliminating the risk of system contamination when<br />

analyzing unknown samples.<br />

Part No.<br />

O-ring set for tube holder<br />

complete set of inner and outer O-rings<br />

008634-000-00<br />

Inner O-ring for tube holder<br />

1 package (5 units) 009411-005-00<br />

66


GERSTEL ® Thermal Extractor, TE 1<br />

Part No.<br />

Empty tubes for GERSTEL ® TE<br />

1 package (5 units) 008589-005-00<br />

Inner O-ring for TE tube holder<br />

Kalrez (1 units) 008766-000-00<br />

PTFE ferrule for TDS<br />

desorption tube<br />

1 package (5 units) 00<strong>27</strong>32-005-00<br />

Desorption tubes for TDS 2/3<br />

and TDS A/A2<br />

see pages 58 – 60<br />

Screens for TE tube<br />

1 package (10 units) 008590-010-00<br />

67


GERSTEL ® Tube Conditioner, TC 1/2<br />

Part No.<br />

For simultaneous conditioning of up to ten TDS tubes or up to<br />

50 Twister ® s (5 Twisters per TDS tube). Tube conditioning is<br />

performed under a flow of inert gas at elevated temperatures. The<br />

gas flow to each tube is independently controlled allowing full loading<br />

flexibility. The GERSTEL TC 2 operates independently of the analytical<br />

system, eliminating the risk of system contamination and ensuring<br />

maximum productivity.<br />

68


GERSTEL ® Tube Conditioner, TC 1/2<br />

Part No.<br />

O-ring set for TC 1/2 tube holder<br />

1 package (1 sets) 009650-000-00<br />

TDS desorption tubes<br />

for 1 mm film thickness Twisters;<br />

tube 6 mm OD x 4.5 mm ID<br />

1 package (10 units) 012518-010-00<br />

69


Part No.<br />

GERSTEL ®<br />

Column Switching Systems, MCS<br />

The GERSTEL MultiColumn Switching System, MCS enables<br />

the combination of different capillary columns in one system for<br />

improved separation of complex samples. The system enables<br />

venting of solvent and low-boiling compounds, improved overall<br />

separation, targeted separation of a particular section of a<br />

chromatogram on a separate column, and accurate effluent<br />

splitting between detectors such as MSD, FID, FPD and the<br />

GERSTEL Olfactory Detection Port, ODP.<br />

! Important note<br />

Column switching devices are<br />

available only for customers with a<br />

GERSTEL column switching system.<br />

Part No.<br />

GRAPHPACK ® 3D/2 column<br />

switching device for MCS 2,<br />

Sulfinert ®<br />

pre-column OD (mm) – main column OD (mm)<br />

0.45 – 0.45 011645-045-00<br />

GRAPHPACK 3D/2 mounting tool<br />

kit for column switching device<br />

For the rapid creation of low-dead-volume<br />

connections when using GRAPHPACK<br />

3D/2 column switching device. Suitable for<br />

all capillary columns with outside diameters<br />

between 0.2 mm and 0.8 mm.<br />

complete kit 006758-000-00<br />

GRAPHPACK mounting tool<br />

tool body without insert<br />

003424-000-00<br />

70<br />

For GRAPHPACK 3D/2 ferrules and<br />

GRAPHPACK 2M ferrules see GRAPHPACK<br />

section beginning with page 16.


GERSTEL ® Multi Column Switching Systems, MCS<br />

Part No.<br />

Part No.<br />

Insert for 1.5 mm<br />

column mounting depth<br />

Color: gold 008994-004-00<br />

Insert holder<br />

Column OD<br />

0.20 mm to 0.31 mm 008995-031-00<br />

0.40 mm to 0.45 mm 008995-045-00<br />

0.70 mm to 0.80 mm 008995-008-00<br />

GRAPHPACK ® 3D/2 ferrule kit<br />

for MCS 2<br />

007361-000-00<br />

Fixing nut for column<br />

switching device<br />

006530-000-00<br />

Restriction capillary<br />

deactivated column OD / column ID / length units<br />

0.40 mm / 0.05 mm / 0.4 m 5 007304-000-00<br />

0.40 mm / 0.05 mm / 5 m 1 007304-005-00<br />

0.40 mm / 0.05 mm / 10 m 1 007304-010-00<br />

71


GERSTEL ® Preparative Fraction Collector, PFC<br />

Part No.<br />

The GERSTEL PFC is used for purification and<br />

collection of compounds or compound classes<br />

following separation by capillary gas chromatography.<br />

Compounds are automatically and selectively collected<br />

in up to six different traps that can be heated or cooled<br />

depending on the needs for the type of compounds.<br />

Highly accurate switching between the traps enable the<br />

analyst to collect and accumulate compounds with high<br />

purity and high yield from up to 150 GC runs. A seventh<br />

trap is available to collect all compounds not collected<br />

in the main traps. These compounds can be saved for<br />

further analysis or for conducting “subtraction studies” of<br />

key compounds.<br />

72


GERSTEL ® Preparative Fraction Collector, PFC<br />

Part No.<br />

GRAPHPACK ® 3D/2 mounting<br />

tool kit for switching device<br />

For the rapid creation of low-dead-volume<br />

connections when using the PFC switching<br />

device. Suitable for all capillary columns with<br />

outside diameters 0.45 mm.<br />

complete kit 006752-000-00<br />

Spare parts<br />

GRAPHPACK mounting tool<br />

single, without insert 003424-000-00<br />

Insert for 3.0 mm mounting<br />

depth<br />

Color: silver<br />

008994-005-00<br />

Insert holder<br />

Column OD<br />

0.45 mm 008995-045-00<br />

GRAPHPACK 3D/2<br />

sealing ferrule<br />

1 package (5 units)<br />

Column OD (mm)<br />

0.31 006520-031-00<br />

0.40 006520-040-00<br />

0.45 006520-045-00<br />

0.70 006520-007-00<br />

73


Part No.<br />

GRAPHPACK ® 3D/2 ferrule<br />

kit for PFC<br />

006761-000-00<br />

GRAPHPACK 3D/2 switching<br />

device for PFC, Sulfinert ®<br />

complete<br />

! Important note<br />

Switching devices are available only<br />

for customers with a GERSTEL ®<br />

Preparative Fraction Collector.<br />

012218-045-00<br />

GRAPHPACK 3D/2 effluent<br />

splitter for FID, Sulfinert ®<br />

for HP 5890 II, Agilent 6890<br />

column OD 0.70 mm 012219-007-00<br />

Replacement<br />

Fixing nut 006530-000-00<br />

Restriction capillary<br />

deactivated,<br />

0.40 mm OD, 0.05 mm ID<br />

length<br />

80 mm (5 units) 007304-001-00<br />

5 m (1 unit) 007304-005-00<br />

10 m (1 unit) 007304-010-00<br />

Silicone tubing for PFC<br />

for connecting component traps to solenoid<br />

valve<br />

length<br />

10 m 007593-000-00<br />

74


GERSTEL ® Preparative Fraction Collector, PFC<br />

Part No.<br />

Trap adapter<br />

for traps 1 µL – 100 µL<br />

1 unit 011229-000-00<br />

Sample traps<br />

1<br />

1 µL<br />

1 package (10 units) 005507-010-00<br />

1 package (50 units) 005507-050-00<br />

1<br />

2<br />

100 µL<br />

1 package (10 units) 005509-010-00<br />

1 package (50 units) 005509-050-00<br />

2<br />

Teflon ferrules<br />

for sample traps<br />

ID 3.0 mm; for traps<br />

1 µL and 100 µL<br />

1 package (10 units) 005002-010-00<br />

Sample traps, coiled<br />

1 µL<br />

1 package (10 units) 006633-010-00<br />

Teflon ferrules<br />

for sample traps<br />

1 package (10 units)<br />

ID 1.8 mm<br />

for 1 µL, coiled traps 005002-028-00<br />

Transfer capillary<br />

for connecting FID effluent splitter to PFC<br />

switching device, deactivated<br />

OD 0.45 mm<br />

L = 870 mm<br />

1 package (5 units) 005010-000-00<br />

Capillary for sample trap<br />

for connecting switching device to<br />

component traps, deactivated<br />

OD 0.45 mm<br />

180 mm (5 units) 005014-000-00<br />

5 m (1 unit) 005014-005-00<br />

10 m (1 unit) 005014-010-00<br />

75


Part No.<br />

GERSTEL ®<br />

Olfactory Detector Port, ODP 2<br />

The GERSTEL ODP allows olfactory detection of compounds by<br />

the human nose. Olfactory detection is performed in parallel to<br />

GC detection with FID, FPD or MSD detectors as compounds<br />

elute from the GC column. The effluent is split as it leaves the<br />

column, arriving simultaneously at the nose and at the detector,<br />

enabling the analyst to gain additional information on odor-active<br />

compounds. Using a headset with a microphone coupled<br />

to voice recognition software, the analyst can insert spoken<br />

comments directly into the chromatogram for peak annotation<br />

and into the analysis report.<br />

Part No.<br />

1<br />

Nose cones<br />

2<br />

1<br />

2<br />

for use with ODP 1/2 with humidifier 006285-000-00<br />

for use with ODP 1/2 without humidifier 008012-000-00<br />

GRAPHPACK ® 3D/2 column<br />

connector with 1/16”<br />

gas connection, Sulfinert ®<br />

Column OD<br />

from 0.80 mm OD to<br />

0.45 mm 013508-045-00<br />

Silicone tubing for connecting<br />

nose cone and humifidier vial<br />

length<br />

2 m 008647-000-00<br />

76


GERSTEL ® Olfactory Detection Port, ODP 2<br />

Part No.<br />

Part No.<br />

Humidifier vial<br />

008204-000-00<br />

GRAPHPACK ® 3D/2<br />

crosspiece kit, Sulfinert ®<br />

for Agilent GC detectors, allows<br />

simultaneous detection at the nose<br />

and the GC detectors.<br />

Includes: GRAPHPACK adapter for<br />

MSD and FID or TCD<br />

main column OD<br />

splitter/restrictor capillary OD<br />

0.31 mm 0.40 mm 013493-031-00<br />

0.45 mm 0.40 mm 013493-045-00<br />

0.70 mm 0.40 mm 013493-007-00<br />

2<br />

GRAPHPACK 3D/2<br />

crosspiece, Sulfinert ®<br />

1<br />

main column OD<br />

2<br />

splitter/restrictor capillary OD<br />

2<br />

2<br />

0.31 mm 0.40 mm 012240-031-00<br />

0.45 mm 0.40 mm 012240-045-00<br />

0.70 mm 0.40 mm 012240-007-00<br />

1<br />

GRAPHPACK 2M detector adapter<br />

MSD HP 5971/5972 GCD Series G 1800 A 006511-040-00<br />

HP 5890 A and Series II and Agilent 6850/6890 006508-040-00<br />

Spare parts<br />

GRAPHPACK nut<br />

for all GRAPHPACK adapters;<br />

1 package (5 units) 001268-005-00<br />

Splitter/restrictor<br />

capillaries<br />

OD/ID length units<br />

0.36 mm / 0.10 mm 1 m 1 006558-001-00<br />

0.36 mm / 0.10 mm 5 m 1 006558-005-00<br />

10 m 1 006558-010-00<br />

0.35 mm / 0.20 mm 10 m 1 009995-003-00<br />

0.36 mm / 0.15 mm 2 m 1 005344-002-00<br />

0.36 mm / 0.15 mm 5 m 1 005344-005-00<br />

77


GERSTEL ® ChemSensor Systems<br />

Part No.<br />

For classification of compound groups or sample groups based<br />

on chemometric analysis with or without chromatography<br />

separation. Three-dimensional data (intensity, mass fragment<br />

and retention time) obtained with a mass selective detector<br />

MSD is reduced to two dimensions, enabling fast and reliable<br />

classification of samples. Introduction techniques used are<br />

Headspace and SPME.<br />

Part No.<br />

MSD spare parts<br />

CI Filament<br />

for the Agilent 5973/5975 MSD;<br />

1 package (2 units)<br />

089345-092-00 *<br />

78<br />

Delivery times upon request *


GERSTEL ® ChemSensor Systems<br />

Part No.<br />

GERSTEL ® ChemSensor<br />

interface spare parts<br />

Transfer capillary<br />

ID = 0.1 mm, OD = 0.36 mm, l = 1 m 006558-001-00<br />

GRAPHPACK ® 2M ferrule<br />

for column OD 0.4 mm;<br />

1 package (10 units) 001805-040-00<br />

GRAPHPACK 2M blind plug<br />

1 package (10 units) 001805-000-00<br />

GRAPHPACK nut<br />

1 package (5 units) 001268-005-00<br />

Direct interface<br />

for ChemSensor CIS 4 Plus 012301-040-00<br />

Silver seal<br />

for direct interface;<br />

1 package (5 units) 002841-005-00<br />

GRAPHPACK 2M MSD adapter<br />

for Hewlett-Packard or<br />

Agilent Technologies 5971/5972/5973/5973 N/5973 Inert/5975 MSD,<br />

for column OD 0.4 mm 006511-040-00<br />

Silver seal<br />

for GRAPHPACK 2M MSD adapter 1 package (5 units) 005249-005-00<br />

Vials and crimp caps for the<br />

ChemSensor 4440<br />

10 mL Crimp cap vial<br />

clear, with flat bottom for 20 mm caps for<br />

use with the Agilent Technologies 7694<br />

Headspace Autosampler<br />

Crimp caps<br />

Aluminum crimp caps with safety closure,<br />

Silicone / PTFE septum, for 20 mm vials<br />

1 package (100 units) 011912-000-00<br />

1 package (5 units) 011912-002-00<br />

79


GERSTEL ® approved supplies<br />

Part No.<br />

Beside our own supplies for GERSTEL systems we offer a wide<br />

range of supplies from other manufacturers. These products<br />

have been tested by us and have our approval for ensuring<br />

proper operation with GERSTEL systems.<br />

Part No.<br />

SS capillary<br />

1/8", 1 m 003701-000-00<br />

Cu tubing<br />

1/8", 1 m 003702-000-00<br />

Swagelok SS adapter<br />

complete with nuts and ferrules<br />

1 unit<br />

1/16" SW, complete 004921-000-00<br />

1/8" SW, complete 004922-000-00<br />

1/4" SW, complete 004923-000-00<br />

1/16" to 2 mm 005207-000-00<br />

Swagelok set<br />

consisting of nut, ferrule, and back ferrule<br />

1 unit<br />

1/4" SS 007887-004-00<br />

1/8" SS 007887-008-00<br />

1/16" SS 007887-016-00<br />

1 package (10 units)<br />

1/4" MS 013343-004-00<br />

1/8" MS 013343-008-00<br />

1/16" MS 013343-016-00<br />

Tube adapter for VICI actuator<br />

1 package (2 units) 010906-002-00<br />

80


GERSTEL ® approved supplies<br />

Part No.<br />

Tools<br />

Set of mandrels 1 package (5 units) 009999-073-00<br />

Magnifying glass (plastic) 10x 009999-079-00<br />

Diamond file 009999-080-00<br />

Open end wrenches<br />

complete set; 6 units, sw 4 – 8 009999-081-00<br />

SW 8 009999-082-00<br />

SW 7 009999-083-00<br />

SW 6 009999-084-00<br />

SW 5.5 009999-085-00<br />

SW 5 009999-086-00<br />

SW 4 009999-087-00<br />

81


Part No.<br />

Reducing ferrules<br />

1 package (5 units)<br />

Vespel reducing ferrule<br />

1/4" – 6 mm 009999-074-00<br />

1/4" – 1/8" 009999-088-00<br />

1/4" – 1/16" 009999-089-00<br />

1/8" – 1/16" 009999-090-00<br />

Graphite ferrule<br />

40% graphite, 1/4" 009999-091-00<br />

40% graphite. 1/8" 009999-092-00<br />

40% graphite, 1/16" 009999-093-00<br />

1/4" 009999-094-00<br />

1/8" 009999-095-00<br />

1/16" 009999-096-00<br />

Vespel graphite ferrule<br />

1/4" 009999-097-00<br />

1/8" 009999-098-00<br />

1/16" 009999-099-00<br />

Cryo tube<br />

2 m<br />

006124-020-00<br />

Teflon ferrules for cryo tube<br />

1 package (2 units)<br />

00<strong>27</strong>32-002-00<br />

Union nut 7/16” for LN2 cooling<br />

006936-000-00<br />

Al-seal for Agilent/HP mass flow controller<br />

1 package (5 units)<br />

004256-005-00<br />

82


GERSTEL ® approved supplies<br />

Part No.<br />

Part No.<br />

Stainless steel tubing<br />

1/16"<br />

1 m 003700-000-00<br />

2 m 003700-002-00<br />

4 m, purged<br />

with 1/8" adapter 007178-000-00<br />

Reducing capillary<br />

Stainless steel; 1 package (3 units)<br />

1/8" to 1/16", 300 mm 005226-000-00<br />

Fused silica capillary tubing for use as transfer line,<br />

make up gas capillary or splitter capillaries<br />

deactivated OD/ID length units Part No.<br />

0.31 mm/0.20 mm 2 m 1 008654-002-00<br />

5 m 1 008654-005-00<br />

0.35 mm/0.20 mm 10 m 1 009995-003-00<br />

0.45 mm/0.32 mm 10 m 1 009995-001-00<br />

25 m 1 009995-002-00<br />

0.25 mm/0.10 mm 10 m 1 009995-006-00<br />

25 m 1 009995-004-00<br />

0.70 mm/0.53 mm 10 m 1 009995-007-00<br />

25 m 1 009995-005-00<br />

0.31 mm/0.20 mm 10 m 1 009999-063-00<br />

25 m 1 009999-066-00<br />

0.20 mm/0.10 mm 25 m 1 009999-064-00<br />

0.<strong>27</strong> mm/0.10 mm 10 m 1 009999-065-00<br />

0.31 mm/0.20 mm 10 m 1 009999-067-00<br />

83


Trade marks<br />

The following trade marks are property of the companies listed below:<br />

Agilent Technologies ®<br />

Carbograph<br />

CarbotrapC, Carbopack,<br />

Carbowax ®<br />

Carboxen, Carbosieve<br />

Chromosorb ®<br />

Chromasorb;<br />

GERSTEL ®<br />

GRAPHPACK ®<br />

Hewlett Packard ® or HP<br />

Kalrez ®<br />

Microliter ®<br />

PEEK polymer<br />

PerkinElmer<br />

StableFlex <br />

Shimadzu ®<br />

SIEMENS<br />

Silcosteel ® , Sulfinert ® , Stabliwax ®<br />

Solid Phase Microextraction (SPME)<br />

Swagelok ®<br />

Teflon ® ; PTFE ® ; Vespel ®<br />

Tenax ®<br />

Tenax TA<br />

Thermo Finnigan ®<br />

Twister ®<br />

Varian<br />

Valco ®<br />

Viton ®<br />

(Agilent Technologies Inc.)<br />

(LARA s.r.l., Italy)<br />

(Supelco, Inc.)<br />

(Union Carbide)<br />

(Supelco, Inc.)<br />

(Manville Corporation, USA)<br />

(Johns Manville)<br />

(GERSTEL GmbH & Co.KG)<br />

(GERSTEL GmbH & Co.KG)<br />

(Hewlett-Packard Corp.)<br />

(DuPont Dow Elastomers.)<br />

(Hamilton Co.)<br />

(Victrex plc)<br />

(PerkinElmer Corp.)<br />

(Supelco, Inc.)<br />

(Shimadzu Scientific Instruments, Inc.)<br />

(Siemens AG)<br />

(Restek Corporation.)<br />

(Supelco)<br />

(Swagelok Co.)<br />

(E.I.Du Pont de Nemours Co, USA)<br />

(Enka Research Institute, Arnhem)<br />

(Buchem bv, Netherlands)<br />

(Thermo Seperation Products)<br />

(GERSTEL GmbH & Co.KG)<br />

(Varian Analytical Instruments)<br />

(Valco Instruments Co.)<br />

(DuPont Dow Elastomers.)<br />

84


Index<br />

Index<br />

Automated Liner EXchange, ALEX 28<br />

Glass insert for ALEX sample tray 29<br />

Ice blue septa 29<br />

O-rings 28, 29<br />

Tools 29<br />

Transport adapter 28<br />

ChemSensor Systems 78<br />

CI filaments 78<br />

Capillaries 79<br />

Direct interface 79<br />

Ferrules 79<br />

MSD adapter 79<br />

Vials, Caps 79<br />

Column Switching Systems, CS 70<br />

Column switching device 70<br />

Ferrule kit 71<br />

Fixing nut 71<br />

Mounting tool kit 70<br />

Restriction capillary 71<br />

Spare parts 70, 71<br />

GRAPHPACK ® Technique 4<br />

2M 4<br />

Adapter Swagelok female 6<br />

Adapter Swagelok male 7<br />

Detector adapter 8, 9<br />

Dual column injector 12, 13<br />

Dual Column Interface MSD 15<br />

Ferrules 5<br />

Injector adapter 10. 11<br />

Mounting tool 5<br />

Spare parts 5<br />

MSD adapter 14<br />

3D/2 16<br />

Column connector 18<br />

Crosspieces 19<br />

Spare parts 19<br />

Ferrules 17<br />

Mounting tool kit 19<br />

Spare parts 19<br />

Screws 17<br />

Sealing ferrule 17<br />

Cooled Injection Systems, CIS 20<br />

3D ferrule 25<br />

Adapter, 2M 22<br />

Adsorption tubes 22<br />

Cryo tube 25<br />

Dual column injector (GP-2M) 23<br />

Spare parts 23<br />

Fixing caps 21<br />

Glass liners 24, 25<br />

Mounting tool 3D 25<br />

Nut 22<br />

On-Column kit, spare parts 23<br />

Replaceable needles 26, <strong>27</strong><br />

Septum head 22<br />

Spare parts 22<br />

Septumless head 21<br />

Spare parts 21<br />

Silver seal 22<br />

Syringes 26, <strong>27</strong><br />

85


Index<br />

MultiPurpose Sampler, MPS 2 30<br />

Crimp cap vials 31<br />

Crimp caps 31, 32<br />

Crimper 34, 35<br />

Decapper 34<br />

Dilutor module 38<br />

Fiber holder 39<br />

Fibers 39,40. 41<br />

HSS injector syringes 37<br />

Spare parts 37<br />

Inserts for agitator 33, 41<br />

Microliter syringes 35, 36, 37<br />

Spare parts 35, 36, 37<br />

Screw cap vials 32, 33<br />

Screw caps 32, 33<br />

Septa 33<br />

Solvent bottle 34<br />

Caps and septa 60<br />

SPME sample vials 32<br />

Trays 41<br />

Vials 31, 32, 33<br />

MultiPurpose Sampler, MPS 3/3C/3 LC 42<br />

Crimper 44<br />

Dilutor module 46<br />

Microliter syringes 45<br />

Sample loop 47<br />

Sample vials 43<br />

Solvent bottle 43<br />

Caps and septa 43<br />

Syringe kit 44<br />

Spare parts 44<br />

Trays 47<br />

Olfactory Detector Port, ODP 76<br />

Crosspiece, 3D/2 77<br />

Detector adapter 77<br />

Ferrule (GP-2M) 5<br />

Humidifier vial 77<br />

Nose cones 76<br />

Nut 77<br />

Crosspiece kit 77<br />

Spare parts 77<br />

Silicone tubing – purge vial 76<br />

Splitter capillary 77<br />

Preparative Fraction Collector, PFC 72<br />

Capillaries 74, 75<br />

Effluent splitter 74<br />

Ferrule kit 74<br />

Mounting tool kit 73<br />

Sample traps 75<br />

Spare parts 75<br />

Sealing ferrule 73<br />

Switching divice 74<br />

Spare parts 73<br />

Trap adapter 75<br />

Pyrolysis Module, PM 1 64<br />

Spare parts 64, 65<br />

GERSTEL approved supplies 80<br />

Capillaries 83<br />

Cryo tube 82<br />

CU capillaries 80<br />

Reduced capillaries 83<br />

Reduced ferrules 82<br />

SS capillaries 80, 83<br />

Swagelok adapter SS 80<br />

Swagelok set 80<br />

Teflon ferrules 82<br />

Tools 81<br />

Tube adapter for VICI actuator 80<br />

Union nut 82<br />

86


Index<br />

Thermal Desorption System, TDS 56<br />

2M injector adapter 63<br />

Adapter for micro screw 63<br />

Adapters 63<br />

Spare parts 63<br />

Desorption tubes 58<br />

<strong>Supplies</strong> 61<br />

Direct interface 62<br />

Locking cone for TDS 2/3<br />

Spare parts 61<br />

Locking cone for TDS A<br />

Spare parts 61<br />

Micro ferrule 63<br />

Micro screw 63<br />

Sample tray for TDS A/A2<br />

Spare parts 69<br />

Septum head for liquid injection 57<br />

SLH calibration adapter 57<br />

Sorption tubes 60<br />

TDS tube adapter 57<br />

Transferline 62<br />

Twister ® 52<br />

Crimper 55<br />

Desorption tubes 53<br />

Decapper 55<br />

Forceps 53<br />

Mechanical crimper 55<br />

Twister Back Extraction 55<br />

Twister Headspace (HSSE) 54<br />

Vials, caps, septa 53, 54<br />

Twister Desorption Unit, TDU 48<br />

3D ferrule 51<br />

Glas insert for Twister sample tray 49<br />

Glas liners 50<br />

Mounting tool 51<br />

O-rings 49<br />

Recommended kit 48<br />

Septa 51<br />

Tools 51<br />

Transport adapter 49<br />

Twister desorption liner 49<br />

Thermal Extractor, TE 1/TE 2 66<br />

Desorptions tubes 58<br />

Spare parts 67<br />

Tube Conditioner, TC 1 68<br />

Spare parts 69<br />

87


Part No. Seite Part No. Seite Part No. Seite<br />

000976-005-00 8, 13<br />

000980-005-00 5<br />

001117-005-00 21, 22<br />

001268-005-00 9, 11, 22, 77, 79<br />

001362-005-00 10. 13<br />

001383-005-00 8, 9, 11<br />

001402-005-00 13<br />

001402-010-00 13<br />

001459-003-00 21<br />

001576-010-00 21, 22<br />

001705-007-00 17<br />

001705-008-00 17<br />

001705-020-00 17<br />

001705-025-00 17<br />

001705-031-00 17<br />

001705-040-00 17<br />

001705-045-00 17<br />

001805-000-00 79<br />

001805-007-00 5, 23<br />

001805-008-00 5<br />

001805-020-00 5<br />

001805-025-00 5<br />

001805-031-00 5<br />

001805-040-00 5, 79<br />

001805-045-00 5<br />

001905-007-00 63<br />

002425-010-00 24<br />

002426-005-00 23, 25, 51<br />

002426-010-00 25, 51<br />

002426-105-00 51<br />

002426-110-00 51<br />

00<strong>27</strong>32-002-00 82<br />

00<strong>27</strong>32-005-00 67<br />

002835-000-00 22<br />

002841-005-00 9, 11, 12, 22, 23, 79<br />

002930-010-00 24<br />

002931-010-00 24<br />

003079-000-00 25<br />

003089-064-00 21<br />

003091-047-00 23<br />

003091-064-00 21<br />

003424-000-00 19, 74, 73<br />

003700-000-00 83<br />

003700-002-00 83<br />

003701-000-00 80<br />

003702-000-00 80<br />

003714-005-00 23<br />

003962-005-00 8, 9<br />

004230-000-00 21<br />

004256-005-00 21, 82<br />

004921-000-00 80<br />

004922-000-00 80<br />

004923-000-00 80<br />

004938-000-00 5<br />

005002-010-00 75<br />

005002-028-00 75<br />

005010-000-00 75<br />

005014-000-00 75<br />

005014-005-0 0 62, 75<br />

005014-010-00 75<br />

005207-000-00 80<br />

005226-000-00 83<br />

005243-001-00 22<br />

005249-005-00 9, 11, 14, 79<br />

005344-002-00 77<br />

88<br />

005344-005-00 77<br />

005507-010-00 75<br />

005507-050-00 75<br />

005509-010-00 75<br />

005509-050-00 75<br />

005532-000-00 23<br />

005610-000-00 21<br />

005615-007-00 17<br />

005615-008-00 17<br />

005615-020-00 17<br />

005615-025-00 17<br />

005615-031-00 17<br />

005615-040-00 17<br />

005615-045-00 17<br />

006124-004-00 25<br />

006124-020-00 25, 82<br />

006144-047-00 23<br />

006144-064-00 21<br />

006188-000-00 19<br />

006285-000-00 76<br />

006460-000-00 22<br />

006508-007-00 8<br />

006508-031-00 8<br />

006508-040-00 77<br />

006508-045-00 8<br />

006509-007-00 10<br />

006509-031-00 10<br />

006509-045-00 10<br />

006511-007-00 9, 11<br />

006511-031-00 9, 11, 14<br />

006511-040-00 14, 81, 79<br />

006511-045-00 9, 11, 14<br />

006520-007-00 17, 73<br />

006520-008-00 17<br />

006520-020-00 17<br />

006520-025-00 17<br />

006520-031-00 17, 73<br />

006520-040-00 17, 73<br />

006520-045-00 17, 73<br />

006530-000-00 75, 74<br />

006558-001-00 77, 79<br />

006558-005-00 77<br />

006558-010-00 77<br />

006633-010-00 75<br />

006752-000-00 73<br />

006758-000-00 70<br />

006761-000-00 74<br />

006828-008-00 5<br />

006828-031-00 5<br />

006828-045-00 5<br />

006829-000-00 5<br />

006830-007-00 7<br />

006830-031-00 7<br />

006830-045-00 7<br />

006831-007-00 7, 8, 10<br />

006831-031-00 7, 8<br />

006831-045-00 7, 8, 10<br />

006832-007-00 7<br />

006832-031-00 7<br />

006832-045-00 7<br />

006833-007-00 6<br />

006833-031-00 6<br />

006833-045-00 6<br />

006834-007-00 6<br />

006834-031-00 6<br />

006834-045-00 6<br />

006835-007-00 6<br />

006835-031-00 6<br />

006835-045-00 6<br />

006936-000-00 82<br />

007178-000-00 83<br />

007233-031-00 15<br />

007233-040-00 15<br />

007233-045-00 15<br />

007236-005-00 15<br />

007259-007-00 22, 23<br />

007259-031-00 22<br />

007259-045-00 22<br />

007301-005-00 10. 13<br />

007302-007-00 10<br />

007302-031-00 10<br />

007302-045-00 10<br />

007304-000-00 75<br />

007304-001-00 78<br />

007304-005-00 71, 74<br />

007304-010-00 71, 74<br />

007348-005-00 15<br />

007361-000-00 71<br />

007464-007-00 11<br />

007464-031-00 11<br />

007464-045-00 11<br />

007513-064-00 21<br />

007514-000-00 22<br />

007519-010-00 24<br />

007530-031-00 12, 23<br />

007530-045-00 12, 23<br />

007533-007-00 13<br />

007533-031-00 13<br />

007533-045-00 13<br />

007541-005-00 23, 25, 51<br />

007541-010-00 25, 51<br />

007542-000-00 25<br />

007593-000-00 74<br />

007671-007-00 13<br />

007671-031-00 13<br />

007671-045-00 13<br />

007820-007-00 63<br />

007820-045-00 63<br />

007821-005-00 63<br />

007823-007-00 62<br />

007823-045-00 62<br />

007884-000-00 61, 65<br />

007887-004-00 80<br />

007887-008-00 80<br />

007887-016-00 80<br />

007910-007-00 63<br />

008005-007-00 9<br />

008005-031-00 9<br />

008005-045-00 9<br />

008012-000-00 76<br />

008019-007-00 11<br />

008019-031-00 11<br />

008019-045-00 11, 63<br />

008020-007-00 9<br />

008020-031-00 9<br />

008020-045-00 9<br />

008021-007-00 10<br />

008021-031-00 10<br />

008021-045-00 10<br />

008030-007-00 13


Part number index<br />

Part No. Seite Part No. Seite Part No. Seite<br />

008030-031-00 13<br />

008030-045-00 13<br />

008068-007-00 9, 11<br />

008068-031-00 9, 11<br />

008068-045-00 9, 11<br />

008174-010-00 60<br />

008189-007-00 8<br />

008189-031-00 8<br />

008189-045-00 8<br />

008190-007-00 8<br />

008190-031-00 8<br />

008190-045-00 8<br />

008191-007-00 9<br />

008191-031-00 9<br />

008191-045-00 9<br />

008192-007-00 9, 11<br />

008192-031-00 9, 11<br />

008192-045-00 9, 11<br />

008204-000-00 77<br />

008235-060-00 60<br />

008246-025-00 22<br />

008311-007-00 62<br />

008311-045-00 62<br />

008339-000-00 23<br />

008351-000-00 60<br />

008357-000-00 58<br />

008420-010-00 24<br />

008577-000-00 22<br />

008584-000-00 22<br />

008589-005-00 67<br />

008590-010-00 67<br />

008599-031-00 15<br />

008599-040-00 15<br />

008634-000-00 70<br />

008647-000-00 76<br />

008654-002-00 83<br />

008654-005-00 83<br />

008687-005-00 62<br />

008688-007-00 62<br />

008766-000-00 67<br />

008980-010-00 60<br />

008994-003-00 19<br />

008994-004-00 71<br />

008994-005-00 73<br />

008995-008-00 19, 71<br />

008995-031-00 19, 71<br />

008995-045-00 19, 71, 73<br />

009013-000-00 61, 65<br />

009013-001-00 61<br />

009040-007-00 13<br />

009040-031-00 13<br />

009040-045-00 13<br />

009095-005-00 61, 65<br />

009117-000-00 58<br />

009118-000-00 58<br />

009171-000-00 60<br />

009250-010-00 64<br />

009250-050-00 64<br />

009411-005-00 66<br />

009553-010-00 65<br />

009650-000-00 69<br />

009947-000-00 58<br />

009948-000-00 58<br />

009949-000-00 58<br />

009970-001-00 35<br />

009970-002-00 35<br />

009970-004-00 35<br />

009970-005-00 35<br />

009970-006-00 35<br />

009970-007-00 35<br />

009970-010-00 26<br />

009970-011-00 26<br />

009970-012-00 26<br />

009970-013-00 <strong>27</strong><br />

009970-014-00 <strong>27</strong><br />

009970-015-00 36<br />

009970-018-00 36<br />

009970-019-00 36<br />

009970-020-00 36<br />

009970-021-00 36<br />

009970-022-00 36<br />

009970-024-00 36<br />

009970-030-00 36<br />

009970-031-00 36<br />

009970-032-00 36<br />

009970-033-00 36<br />

009970-034-00 36<br />

009970-040-00 36<br />

009970-041-00 36<br />

009970-042-00 36<br />

009970-043-00 36<br />

009970-048-00 36<br />

009970-049-00 57<br />

009970-050-00 60<br />

009970-051-00 37<br />

009970-052-00 37<br />

009970-057-00 37<br />

009970-058-00 36<br />

009970-059-00 57<br />

009980-028-00 <strong>27</strong><br />

009980-029-00 <strong>27</strong><br />

009980-030-00 <strong>27</strong><br />

009980-031-00 <strong>27</strong><br />

009980-032-00 <strong>27</strong><br />

009980-033-00 <strong>27</strong><br />

009980-040-00 26<br />

009980-044-00 37<br />

009980-045-00 37<br />

009980-046-00 37<br />

009980-047-00 37<br />

009980-048-00 37<br />

009995-001-00 83<br />

009995-002-00 83<br />

009995-003-00 77, 83<br />

009995-004-00 83<br />

009995-005-00 83<br />

009995-006-00 83<br />

009995-007-00 83<br />

009996-059-00 26<br />

009999-006-00 26<br />

009999-010-00 21<br />

009999-014-00 21<br />

009999-015-00 21<br />

009999-016-00 21<br />

009999-017-00 26<br />

009999-018-00 26<br />

009999-019-00 26<br />

009999-021-00 26<br />

009999-025-00 53<br />

009999-041-00 <strong>27</strong><br />

009999-052-00 <strong>27</strong><br />

009999-063-00 83<br />

009999-064-00 83<br />

009999-065-00 87<br />

009999-066-00 83<br />

009999-067-00 83<br />

009999-073-00 81<br />

009999-074-00 82<br />

009999-079-00 81<br />

009999-080-00 81<br />

009999-081-00 81<br />

009999-082-00 81<br />

009999-083-00 81<br />

009999-084-00 81<br />

009999-085-00 81<br />

009999-086-00 81<br />

009999-087-00 81<br />

009999-088-00 82<br />

009999-089-00 82<br />

009999-090-00 82<br />

009999-091-00 11, 13, 82<br />

009999-092-00 9, 82<br />

009999-093-00 10. 15, 82<br />

009999-094-00 82<br />

009999-095-00 82<br />

009999-096-00 82<br />

009999-097-00 82<br />

009999-098-00 82<br />

009999-099-00 82<br />

009999-204-00 29, 51<br />

010040-000-00 58<br />

010041-000-00 58<br />

010042-000-00 58<br />

010044-000-00 58<br />

010372-005-00 61<br />

010375-007-00 9<br />

010375-031-00 9<br />

010375-045-00 9<br />

010441-000-00 61<br />

010454-003-00 57<br />

010454-004-00 57<br />

010649-000-00 58<br />

010649-010-00 58<br />

010650-000-00 58<br />

010650-010-00 58<br />

010849-010-00 24<br />

010850-010-00 24<br />

010906-002-00 80<br />

010963-005-00 62<br />

011003-000-00 62<br />

011004-000-00 62<br />

011005-000-00 62<br />

011025-007-00 62<br />

011025-045-00 62<br />

011061-005-00 61<br />

011222-001-00 52<br />

011222-002-00 52<br />

011229-000-00 75<br />

011333-001-00 52<br />

011333-002-00 52<br />

011444-001-00 52<br />

011444-002-00 52<br />

011555-001-00 52<br />

011555-002-00 52<br />

011619-000-00 60<br />

89


Part No. Seite Part No. Seite Part No. Seite<br />

011620-010-00 60<br />

011628-007-00 62<br />

011628-045-00 62<br />

011645-045-00 70<br />

011654-007-00 5<br />

011654-031-00 5<br />

011654-045-00 5<br />

011708-010-00 24<br />

011709-010-00 24<br />

011710-010-00 24<br />

011711-010-00 24<br />

011712-010-00 24<br />

011714-005-00 24<br />

011716-005-00 24<br />

011754-020-00 60<br />

011868-002-00 25<br />

011912-000-00 79<br />

011912-002-00 79<br />

012185-005-00 62<br />

012186-000-00 62<br />

012195-099-00 55<br />

012218-045-00 74<br />

012219-007-00 74<br />

012224-007-00 19<br />

012224-031-00 19<br />

012224-045-00 19<br />

012240-007-00 19, 77<br />

012240-031-00 19, 77<br />

012240-040-00 19<br />

012240-045-00 19, 77<br />

012260-005-00 58<br />

012<strong>27</strong>5-005-00 58<br />

012<strong>27</strong>6-005-00 58<br />

012<strong>27</strong>7-005-00 58<br />

012301-040-00 79<br />

012346-005-00 58<br />

012347-005-00 58<br />

012370-000-00 53<br />

012423-010-00 49<br />

012423-100-00 49<br />

012424-010-00 49<br />

012424-100-00 49<br />

012436-010-00 50<br />

012437-010-00 50<br />

012438-010-00 50<br />

012439-010-00 50<br />

012440-003-00 50<br />

012440-004-00 50<br />

012441-010-00 50<br />

012442-010-00 50<br />

012443-010-00 50<br />

012444-010-00 50<br />

012458-000-00 58<br />

012491-000-00 54<br />

012492-000-00 54<br />

012518-010-00 53, 69<br />

012565-100-00 49<br />

012659-010-00 60<br />

01<strong>27</strong>13-003-00 48<br />

01<strong>27</strong>13-004-00 48<br />

01<strong>27</strong>41-010-00 50<br />

01<strong>27</strong>42-010-00 50<br />

01<strong>27</strong>81-003-00 51<br />

90<br />

01<strong>27</strong>81-004-00 51<br />

013010-100-00 49<br />

013032-010-00 49<br />

013032-100-00 49<br />

013115-000-00 58<br />

013148-000-00 24<br />

013148-005-00 24<br />

013238-000-00 24<br />

013238-005-00 24<br />

013244-007-00 22, 23<br />

013244-031-00 22<br />

013244-045-00 22<br />

013247-005-00 24<br />

013248-005-00 24<br />

013249-005-00 24<br />

013250-005-00 24<br />

013329-000-00 57<br />

013343-004-00 80<br />

013343-008-00 80<br />

013343-016-00 80<br />

013407-007-00 18<br />

013407-031-00 18<br />

013407-040-00 18<br />

013407-045-00 18<br />

013409-010-00 50<br />

013431-031-00 18<br />

013440-040-00 18<br />

013445-031-00 18<br />

013445-040-00 18<br />

013445-045-00 18<br />

013492-000-00 19<br />

013493-007-00 77<br />

013493-031-00 77<br />

013493-045-00 77<br />

013507-007-00 18<br />

013507-031-00 18<br />

013507-040-00 18<br />

013507-045-00 18<br />

013508-045-00 18, 76<br />

013531-031-00 18<br />

013540-040-00 18<br />

013543-003-00 25<br />

013543-004-00 25<br />

013545-031-00 18<br />

013545-040-00 18<br />

013545-045-00 18<br />

013605-000-00 24<br />

013605-005-00 24<br />

013645-010-00 49<br />

013745-000-00 52<br />

013775-010-00 50<br />

013776-010-00 50<br />

013794-010-00 29<br />

013794-100-00 29<br />

013795-000-00 28<br />

013795-010-00 28<br />

013822-000-00 28<br />

013881-010-00 24<br />

013882-010-00 24<br />

013910-010-00 24<br />

013911-010-00 50<br />

013931-010-00 29<br />

013934-005-00 28<br />

014052-100-00 29, 51, 57<br />

014173-010-00 60<br />

014284-010-00 24<br />

014292-010-00 29<br />

014292-100-00 29<br />

014454-000-00 57<br />

014454-021-00 57<br />

014456-005-00 57<br />

089280-009-00 54<br />

089280-010-00 54<br />

089345-092-00 78<br />

089355-076-00 32, 43, 53<br />

093611-010-00 36<br />

093611-020-00 44<br />

093611-021-00 44<br />

093611-022-00 44<br />

093611-026-00 44<br />

093611-0<strong>27</strong>-00 38, 46<br />

093611-028-00 38<br />

093611-029-00 38<br />

093611-032-00 38<br />

093611-033-00 38<br />

093611-034-00 38, 46<br />

093631-002-00 33, 41<br />

093631-007-00 41, 47<br />

093631-008-00 41, 47<br />

093631-009-00 41, 47<br />

093631-010-00 47<br />

093631-054-00 34, 43<br />

093631-055-00 34, 43<br />

093631-068-00 41, 47<br />

093631-069-00 41, 47<br />

093631-080-00 41, 47<br />

093631-084-00 41, 47<br />

093631-086-00 41, 47<br />

093631-091-00 38, 46<br />

093631-092-00 38, 46<br />

093631-093-00 38, 46<br />

093631-094-00 38, 46<br />

093631-095-00 38, 46<br />

093631-096-00 38, 46<br />

093632-038-00 38, 46<br />

093632-039-00 38, 46<br />

093632-040-00 38, 46<br />

093632-041-00 38, 46<br />

093632-043-00 38, 46<br />

093632-045-00 38, 46<br />

093632-050-00 34<br />

093639-000-00 39<br />

093639-001-00 39<br />

093639-005-00 39<br />

093639-009-00 40<br />

093639-013-00 40<br />

093639-020-00 39<br />

093639-021-00 39<br />

093639-022-00 39<br />

093639-023-00 39<br />

093639-024-00 40<br />

093639-025-00 40<br />

093639-026-00 40<br />

093639-0<strong>27</strong>-00 40<br />

093639-028-00 40<br />

093639-029-00 40


Part number index<br />

Part No. Seite Part No. Seite Part No. Seite<br />

093639-030-00 40<br />

093639-031-00 41<br />

093640-000-00 34, 44<br />

093640-001-00 34, 55<br />

093640-002-00 34, 44<br />

093640-003-00 34, 55<br />

093640-004-00 31, 43<br />

093640-005-00 31, 53<br />

093640-006-00 31, 53<br />

093640-007-00 31, 43<br />

093640-008-00 31<br />

093640-009-00 55<br />

093640-010-00 35<br />

093640-012-00 35<br />

093640-015-00 31<br />

093640-017-00 35<br />

093640-018-00 35<br />

093640-019-00 35<br />

093640-020-00 35<br />

093640-021-00 35<br />

093640-022-00 35<br />

093640-023-00 35<br />

093640-024-00 35<br />

093640-025-00 35<br />

093640-029-00 32, 43<br />

093640-031-00 32<br />

093640-032-00 32<br />

093640-034-00 32<br />

093640-035-00 32<br />

093640-036-00 32<br />

093640-037-00 32<br />

093640-038-00 32<br />

093640-039-00 32<br />

093640-040-00 32<br />

093640-041-00 32<br />

093640-042-00 32<br />

093640-043-00 32<br />

093640-045-00 33, 43<br />

093640-046-00 33, 43<br />

093640-047-00 33, 43<br />

093640-048-00 33, 43<br />

093640-050-00 32<br />

093640-052-00 31, 43<br />

093640-053-00 31, 43<br />

093640-054-00 34, 44<br />

093640-055-00 34<br />

093640-056-00 33<br />

093640-057-00 33<br />

093640-058-00 33, 44<br />

093640-059-00 33<br />

093640-062-00 31<br />

093640-063-00 31<br />

093640-064-00 31<br />

093711-000-00 45<br />

093711-001-00 45<br />

093711-002-00 45<br />

093711-003-00 45<br />

093711-004-00 45<br />

093711-005-00 45<br />

093711-006-00 45<br />

093711-007-00 44<br />

093711-008-00 44<br />

093711-009-00 44<br />

093711-010-00 44<br />

093711-011-00 44<br />

093711-012-00 44<br />

093711-013-00 44<br />

093711-014-00 45<br />

093711-019-00 44<br />

093711-020-00 44<br />

093711-021-00 44<br />

093711-022-00 46<br />

093711-023-00 46<br />

093711-026-00 44<br />

093711-0<strong>27</strong>-00 45<br />

093711-028-00 45<br />

093711-038-00 45<br />

093711-039-00 45<br />

093711-040-00 45<br />

093711-041-00 45<br />

093711-042-00 45<br />

093711-043-00 45<br />

093711-044-00 45<br />

91

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!