Supplies Catalogue 2006/2007, (pdf; 4,27 MB) - Gerstel
Supplies Catalogue 2006/2007, (pdf; 4,27 MB) - Gerstel
Supplies Catalogue 2006/2007, (pdf; 4,27 MB) - Gerstel
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
About this <strong>Catalogue</strong><br />
T<br />
his »Analytical <strong>Supplies</strong>« catalogue provides an extensive<br />
list of consumables, accessories and spare parts that<br />
are essential for the smooth operation of GERSTEL ® systems<br />
for chromatographic analysis. You have the right to demand<br />
the highest quality performance from GERSTEL systems and<br />
we have compiled this list so that this performance can be<br />
maintained throughout the life of your system.<br />
Please use only consumables, accessories and spare parts<br />
provided by GERSTEL. All GERSTEL products are made to<br />
exact specifications. Use of products not approved by GERSTEL<br />
can cause system malfunction or damage and may void the<br />
system’s warranty.<br />
If you have any questions please do not hesitate to contact us.<br />
The most efficient way is to reach us is through our web site at<br />
www.gerstel.com. Your questions can be answered even more<br />
quickly by linking to your local sales office through our site.<br />
2
Table of contents<br />
GRAPHPACK ® 2M connection technology ................................................................4<br />
GRAPHPACK 2M adapters with Swagelok thread, male ........................................6<br />
GRAPHPACK 2M adapters with Swagelok thread, female ........................................7<br />
GRAPHPACK 2M detector adapters .........................................................................8<br />
GRAPHPACK 2M inlet adapters .............................................................................. 10<br />
GRAPHPACK 2M dual column inlet adapter ........................................................... 12<br />
GRAPHPACK 2M MSD adapter .............................................................................. 14<br />
GRAPHPACK 2M dual column interface for MSD ................................................... 15<br />
GRAPHPACK 3D/2 connection technology ............................................................ 16<br />
GRAPHPACK 3D/2 column connector ................................................................... 18<br />
GRAPHPACK 3D/2 column connector with gas connection .................................... 18<br />
GRAPHPACK 3D/2 crosspieces ............................................................................. 19<br />
GERSTEL ® Cooled Injection System, CIS ...............................................................20<br />
GERSTEL Automated Liner Exchange, ALEX...........................................................28<br />
GERSTEL MultiPurpose Sampler, MPS 2 ................................................................30<br />
GERSTEL MultiPurpose Sampler, MPS 3 ................................................................42<br />
GERSTEL Twister ® Desorption Unit, TDU.................................................................48<br />
GERSTEL Twister ....................................................................................................52<br />
GERSTEL Thermal Desorption System, TDS ..........................................................56<br />
GERSTEL Pyrolysis Module, PM 1...........................................................................64<br />
GERSTEL Thermal Extractor, TE 1/2 ......................................................................66<br />
GERSTEL Tube Conditioner, TC 2 ..........................................................................68<br />
GERSTEL Column Switching Systems, MCS ..........................................................70<br />
GERSTEL Preparative Fraction Collector, PFC ........................................................72<br />
GERSTEL Olfactory Detector Port, ODP .................................................................76<br />
GERSTEL ChemSensor System ..............................................................................78<br />
GERSTEL Approved <strong>Supplies</strong> .................................................................................80<br />
Accessories by other leading analytical equipment suppliers ..................................84<br />
Index ......................................................................................................................85<br />
Page<br />
3
GRAPHPACK ® 2M connection technology<br />
Part No.<br />
For the rapid and economical connection of capillary columns to<br />
GC Inlets and Detectors.<br />
The components of the GRAPHPACK 2M connection technology<br />
are the GRAPHPACK 2M ferrule, the GRAPHPACK 2M adapter<br />
and the GRAPHPACK nut.<br />
GRAPHPACK 2M ferrule<br />
The GRAPHPACK 2M ferrule is a<br />
cylindrical metal cartridge packed with<br />
graphite.<br />
Advantages<br />
● Rapid and reliable installation/<br />
changing of capillary columns.<br />
● Rapid mounting and positioning of<br />
the ferrules on the capillary column<br />
outside the oven.<br />
● Leak-free connections are achieved<br />
without excessive tightening.<br />
● Connections remain leak-free with<br />
temperature cycling.<br />
● Self-centering of the ferrule on the<br />
GRAPHPACK 2M adapter.<br />
● The capillary column is always<br />
centered in the inlet or detector.<br />
● No damage to column coating.<br />
● Economical, no more than two<br />
ferrules are required for the life of<br />
a column.<br />
GRAPHPACK 2M<br />
Adapter<br />
Available for all column outside diameters<br />
between 0.2 mm and 0.8 mm.<br />
GRAPHPACK nut<br />
A slotted nut for securing the column to<br />
all GRAPHPACK adapters.<br />
4<br />
GRAPHPACK 2M and GRAPHPACK 3D/2 ferrules<br />
are not interchangeable.
GRAPHPACK ® 5<br />
Column OD / ID<br />
Part No.<br />
GRAPHPACK 2M ferrules<br />
1 package (10 units)<br />
0.20 mm / 0.1 mm 001805-020-00<br />
0.25 mm / 0.1 mm 001805-025-00<br />
0.31 mm / 0.20 mm 001805-031-00<br />
0.40 mm / 0.25 mm 001805-040-00<br />
0.45 mm / 0.32 mm 001805-045-00<br />
0.70 mm / 0.53 mm 001805-007-00<br />
0.80 mm / 0.<strong>27</strong> mm 001805-008-00<br />
(for glass)<br />
GRAPHPACK 2M plug ferrule<br />
1 package (5 units)<br />
0.31 mm / 0.20 mm 011654-031-00<br />
0.45 mm / 0.32 mm 011654-045-00<br />
0.70 mm / 0.53 mm 011654-007-00<br />
GRAPHPACK 2M<br />
mounting tool kit<br />
For mounting and positioning of<br />
GRAPHPACK 2M ferrules on capillary columns.<br />
Complete kit 006829-000-00<br />
Spare parts<br />
GRAPHPACK mounting tool for<br />
GRAPHPACK 2M ferrules<br />
tool body, without insert<br />
004938-000-00<br />
Column OD<br />
Inserts 0.31 mm (red) 006828-031-00<br />
0.40 to 0.45 mm (green) 006828-045-00<br />
0.70 to 0.80 mm (black) 006828-008-00<br />
GRAPHPACK nut<br />
for mounting tool<br />
1 package (5 units)<br />
000980-005-00<br />
OD = Outside diameter<br />
ID = Inside diameter
GRAPHPACK ® 2M adapters with<br />
Swagelok ® thread, female<br />
Part No.<br />
For the conversion of GC systems with Swagelok fittings<br />
to GRAPHPACK 2M technology.<br />
Column OD / ID<br />
Part No.<br />
with 1/4“ Swagelok female thread 0.31 mm / 0.20 mm 006835-031-00<br />
0.45 mm / 0.32 mm 006835-045-00<br />
0.70 mm / 0.53 mm 006835-007-00<br />
with 1/8“ Swagelok female thread 0.31 mm / 0.20 mm 006834-031-00<br />
0.45 mm / 0.32 mm 006834-045-00<br />
0.70 mm / 0.53 mm 006834-007-00<br />
with 1/16“ Swagelok female thread 0.31 mm / 0.20 mm 006833-031-00<br />
0.45 mm / 0.32 mm 006833-045-00<br />
0.70 mm / 0.53 mm 006833-007-00<br />
6<br />
GRAPHPACK 2M ferrules are not included with the GRAPHPACK<br />
detector adapters and must be ordered separately.<br />
When using 0.40 mm OD capillaries, use a 0.45 mm OD adapter in<br />
combination with a 0.40 mm ferrule.
GRAPHPACK ® 7<br />
GRAPHPACK 2M adapters with<br />
Swagelok ® thread, male<br />
Part No.<br />
For the conversion of GC systems with Swagelok fittings to<br />
GRAPHPACK 2M technology.<br />
Column OD / ID<br />
Part No.<br />
with 1/4“ Swagelok male thread<br />
0.31 mm / 0.20 mm 006832-031-00<br />
0.45 mm / 0.32 mm 006832-045-00<br />
0.70 mm / 0.53 mm 006832-007-00<br />
with 1/8“ Swagelok male thread 0.31 mm / 0.20 mm 006831-031-00<br />
0.45 mm / 0.32 mm 006831-045-00<br />
0.70 mm / 0.53 mm 006831-007-00<br />
with 1/16“ Swagelok male thread<br />
0.31 mm / 0.20 mm 006830-031-00<br />
0.45 mm / 0.32 mm 006830-045-00<br />
0.70 mm / 0.53 mm 006830-007-00
GRAPHPACK ® 2M detector adapters<br />
Part No.<br />
For the low-cost conversion of detector connections of various<br />
GC manufacturers to GRAPHPACK 2M connection technology.<br />
Advantages<br />
● Economical, only one sealing technology is used for all detectors.<br />
● No contact with the inside of the detector because of accurate<br />
centering.<br />
Column OD / ID<br />
Part No.<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
HP 5890 A and Series II and Agilent 6850/6890<br />
for FID, NPD<br />
0.31 mm / 0.20 mm 006508-031-00<br />
0.45 mm / 0.32 mm 006508-045-00<br />
0.70 mm / 0.53 mm 006508-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 003962-005-00<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
HP 5890 A and Series II and Agilent 6850/6890<br />
for TCD, FPD<br />
0.45 mm / 0.32 mm 006831-045-00<br />
0.70 mm / 0.53 mm 006831-007-00<br />
Chrompack 9000<br />
0.31 mm / 0.20 mm 006831-031-00<br />
0.45 mm / 0.32 mm 006831-045-00<br />
0.70 mm / 0.53 mm 006831-007-00<br />
Dani Detectors; M4 0.31 mm / 0.20 mm 008189-031-00<br />
0.45 mm / 0.32 mm 008189-045-00<br />
Spare parts<br />
0.70 mm / 0.53 mm 008189-007-00<br />
Silver seal; 1 package (5 units) 001383-005-00<br />
Fisons Series 8000, Trace,<br />
Tremetics, CE 5300, CE 8000<br />
0.31 mm / 0.20 mm 008190-031-00<br />
0.45 mm / 0.32 mm 008190-045-00<br />
0.70 mm / 0.53 mm 008190-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 000976-005-00<br />
8<br />
GRAPHPACK 2M ferrules are not included with the GRAPHPACK detector adapters<br />
and must be ordered separately.
GRAPHPACK ® 9<br />
Column OD / ID<br />
Part No.<br />
O.I. Analytical PID<br />
0.31 mm / 0.20 mm 008005-031-00<br />
0.45 mm / 0.32 mm 008005-045-00<br />
0.70 mm / 0.53 mm 008005-007-00<br />
O.I. Analytical PFPD and XSD<br />
Spare parts<br />
0.31 mm / 0.20 mm 010375-031-00<br />
0.45 mm / 0.32 mm 010375-045-00<br />
0.70 mm / 0.53 mm 010375-007-00<br />
Silver seal; 1 package (5 units) 005249-005-00<br />
Perkin Elmer<br />
Spare parts<br />
0.31 mm / 0.20 mm 008020-031-00<br />
0.45 mm / 0.32 mm 008020-045-00<br />
0.70 mm / 0.53 mm 008020-007-00<br />
Vespel graphite ferrule; 1 package (5 units) 009999-092-00<br />
Siemens RGC 0202<br />
Spare parts<br />
0.31 mm / 0.20 mm 008191-031-00<br />
0.45 mm / 0.32 mm 008191-045-00<br />
0.70 mm / 0.53 mm 008191-007-00<br />
Silver seal; 1 package (5 units) 003962-005-00<br />
Shimadzu 14 A and 17 A<br />
Spare parts<br />
0.31 mm / 0.20 mm 008068-031-00<br />
0.45 mm / 0.32 mm 008068-045-00<br />
0.70 mm / 0.53 mm 008068-007-00<br />
Silver seal; 1 package (5 units) 002841-005-00<br />
Shimadzu 2010<br />
Spare parts<br />
0.31 mm / 0.20 mm 006511-031-00<br />
0.45 mm / 0.32 mm 006511-045-00<br />
0.70 mm / 0.53 mm 006511-007-00<br />
Silver seal; 1 package (10 units) 005249-005-00<br />
Varian 3300 / 3400 / 3500 /<br />
3600 / 3800 / 3900 & Saturn<br />
Spare parts<br />
0.31 mm / 0.20 mm 008192-031-00<br />
0.45 mm / 0.32 mm 008192-045-00<br />
0.70 mm / 0.53 mm 008192-007-00<br />
Silver seal; 1 package (5 units) 001383-005-00<br />
Spare parts<br />
for all GRAPHPACK adapters<br />
GRAPHPACK nut; 1 package (5 units) 001268-005-00
GRAPHPACK ® 2M inlet adapters<br />
Part No.<br />
For the low-cost conversion of inlet<br />
connections of various GC<br />
manufacturers to GRAPHPACK 2M<br />
connection technology.<br />
Advantages<br />
● Economical, only one sealing technology is<br />
used for all inlets.<br />
● No contact with the inlet liner because of<br />
accurate centering.<br />
Column OD / ID<br />
Part No.<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
Split/splitless injector<br />
HP 5890 A and Series II and<br />
Agilent 6850/6890<br />
0.31 mm / 0.20 mm 006509-031-00<br />
0.45 mm / 0.32 mm 006509-045-00<br />
0.70 mm / 0.53 mm 006509-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 001362-005-00<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
HP 5890 A and Series II and<br />
Agilent 6850/6890 for TCD.<br />
0.45 mm / 0.32 mm 006831-045-00<br />
0.70 mm / 0.53 mm 006831-007-00<br />
Fisons Series 8000<br />
Split/splitless injector<br />
0.31 mm / 0.20 mm 007302-031-00<br />
0.45 mm / 0.32 mm 007302-045-00<br />
0.70 mm / 0.53 mm 007302-007-00<br />
Sold without silver seal and nut.<br />
Spare parts<br />
Silver seal. 11.5 mm OD; 1 package (5 units) 007301-005-00<br />
Perkin Elmer<br />
PSS Injector<br />
0.31 mm / 0.20 mm 008021-031-00<br />
0.45 mm / 0.32 mm 008021-045-00<br />
0.70 mm / 0.53 mm 008021-007-00<br />
Spare parts<br />
Vespel ferrule; 1 package (5 units) 009999-093-00<br />
10<br />
When using 0.40 mm OD capillaries, use a 0.45 mm OD adapter in combination with<br />
a 0.40 mm ferrule.
GRAPHPACK ® 11<br />
Column OD / ID<br />
Part No.<br />
Perkin Elmer<br />
Split/splitless injector<br />
0.31 mm / 0.20 mm 007464-031-00<br />
0.45 mm / 0.32 mm 007464-045-00<br />
0.70 mm / 0.53 mm 007464-007-00<br />
Spare parts<br />
Vespel ferrule 1/4“; 1 package (5 units) 009999-091-00<br />
Shimadzu 14 A, 17 A<br />
Split/splitless injector<br />
0.31 mm / 0.20 mm 008068-031-00<br />
0.45 mm / 0.32 mm 008068-045-00<br />
0.70 mm / 0.53 mm 008068-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 002841-005-00<br />
Shimadzu 2010<br />
Split/splitless injector<br />
0.31 mm / 0.20 mm 006511-031-00<br />
0.45 mm / 0.32 mm 006511-045-00<br />
0.70 mm / 0.53 mm 006511-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 005249-005-00<br />
Valco VICI Valve<br />
0.31 mm / 0.20 mm 008019-031-00<br />
0.45 mm / 0.32 mm 008019-045-00<br />
0.70 mm / 0.53 mm 008019-007-00<br />
Varian 3300 / 3400 / 3500 /<br />
3600 / 3800 / 3900 & Saturn<br />
0.31 mm / 0.20 mm 008192-031-00<br />
0.45 mm / 0.32 mm 008192-045-00<br />
0.70 mm / 0.53 mm 008192-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 001383-005-00<br />
Spare parts<br />
for all GRAPHPACK adapters<br />
GRAPHPACK nut; 1 package (5 units) 001268-005-00
GRAPHPACK ® 2M dual column<br />
inlet adapter<br />
Part No.<br />
This dual column inlet adapter permits the simultaneous connection<br />
of two fused silica capillary columns to one inlet. This allows<br />
a sample to be analyzed on two columns simultaneously from a<br />
single injection. Adapters are available for GERSTEL ® inlets as well<br />
as for all major GC manufactures.<br />
Advantages<br />
● Reduction in analysis time.<br />
● Simultaneous analysis using capillary columns with different<br />
polarities.<br />
● No split discrimination due to contact of the capillary column<br />
with the inside wall of the inlet liner thanks to column selfcentering<br />
design.<br />
Column OD / ID<br />
Part No.<br />
GERSTEL Cooled Injection<br />
System CIS 3 and CIS 4<br />
0.31 mm / 0.20 mm 007530-031-00<br />
0.45 mm / 0.32 mm 007530-045-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 002841-005-00<br />
12
GRAPHPACK ® 13<br />
Column OD / ID<br />
Part No.<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
Split/splitless injector<br />
HP 5890 A and Series II and Agilent 6890<br />
0.31 mm / 0.20 mm 007533-031-00<br />
0.45 mm / 0.32 mm 007533-045-00<br />
0.70 mm / 0.53 mm 007533-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 001362-005-00<br />
Fisons Series 8000<br />
Split/splitless injector<br />
0.31 mm / 0.20 mm 008030-031-00<br />
0.45 mm / 0.32 mm 008030-045-00<br />
0.70 mm / 0.53 mm 008030-007-00<br />
Spare parts<br />
Silver seal. 5 mm OD; 1 package (10 units) 001402-010-00<br />
Silver seal. 11.5 mm OD; 1 package (5 units) 007301-005-00<br />
Perkin Elmer<br />
Split/splitless injector<br />
0.31 mm / 0.20 mm 007671-031-00<br />
0.45 mm / 0.32 mm 007671-045-00<br />
0.70 mm / 0.53 mm 007671-007-00<br />
Spare parts<br />
Vespel ferrule 1/4“; 1 package (5 units) 009999-091-00<br />
Carlo Erba CE 5300 0.31 mm / 0.20 mm 009040-031-00<br />
0.45 mm / 0.32 mm 009040-045-00<br />
0.70 mm / 0.53 mm 009040-007-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 000976-005-00<br />
Silver seal; 1 package (10 units) 001402-010-00<br />
When using 0.40 mm OD capillary, use a 0.45 mm OD adapter in combination with a<br />
0.40 mm ferrule.
Part No.<br />
GRAPHPACK ® 2M MSD adapter<br />
For the low-cost conversion of MSD connections of various GC<br />
manufacturers to GRAPHPACK 2M connection technology.<br />
Advantages<br />
● Economical, only one sealing technology is used for the capillary<br />
column.<br />
● Leak-free at elevated or fluctuating temperatures and under high<br />
vacuums.<br />
Column OD / ID<br />
Part No.<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
MSD HP 5971 / 5972,<br />
Agilent 5973A / 5973N /<br />
5973 inert, 5975, HP GCD<br />
0.31 mm / 0.20 mm 006511-031-00<br />
0.40 mm / 0.25 mm 006511-040-00<br />
0.45 mm / 0.32 mm 006511-045-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 005249-005-00<br />
14
GRAPHPACK ® 15<br />
GRAPHPACK 2M dual column<br />
interface for MSD<br />
Part No.<br />
For the simultaneous connection of two capillary columns to a<br />
single MSD<br />
Advantages<br />
● Use of two different polarity capillary columns with one MSD.<br />
Column OD / ID<br />
Part No.<br />
.<br />
Hewlett-Packard<br />
MSD HP 5971/5972<br />
0.31 mm / 0.20 mm 007233-031-00<br />
0.40 mm / 0.25 mm 007233-040-00<br />
0.45 mm / 0.32 mm 007233-045-00<br />
Spare parts<br />
Vespel ferrule; 1 package (5 units) 007348-005-00<br />
Interface nut; 1 package (5 units) 007236-005-00<br />
Agilent Technologies /<br />
Hewlett-Packard<br />
MSD Agilent/HP 5973A,<br />
5973N, 5973 inert, 5975<br />
0.31 mm / 0.20 mm 008599-031-00<br />
0.40 mm / 0.25 mm 008599-040-00<br />
Spare parts<br />
Vespel ferrule; 1 package (5 units) 009999-093-00<br />
Inferface nut; 1 package (5 units) 007236-005-00
GRAPHPACK ®<br />
3D/2 connection<br />
technology<br />
For the rapid, reliable and low-dead-volume<br />
connection of two capillary columns with<br />
the same or different outside diameter, or<br />
of different materials.<br />
The components of the GRAPHPACK 3D/2<br />
connection technology are the GRAPHPACK<br />
3D/2 ferrule, the GRAPHPACK 3D/2 connector<br />
and the GRAPHPACK 3D/2 screw.<br />
Sulfinert ®<br />
Part No.<br />
All GRAPHPACK 3D/2 components which come into contact with analytes are<br />
Sulfinert ® coated. This offers the optimal surface material for every GC analysis.<br />
Sulfinert is the latest in passivation coating technology, the next generation of the<br />
well-known Silcosteel® coating.<br />
The Sulfinert coating is ideal for use in all GC applications such as environmental,<br />
flavour and fragrance, off-odors, food and beverage, chemical and petrochemical,<br />
pharmaceutical and polymers. Sulfinert is stable over a wide pH range and unlike fused<br />
silica coatings, which can dissolve in caustic environments; the Sulfinert coating is<br />
stable when sampling caustic amines as well as acidic sulfur compounds.<br />
Sulfinert provides for the determination of ultra-low levels of organic compounds and<br />
superior inertness for sulfur compounds, simplifying the choice of passivation surface.<br />
When working with GERSTEL ® GRAPHPACK 3D/2 products, there is no need to use<br />
different passivation surfaces for different applications or different analytes.<br />
GERSTEL GRAPHPACK 3D/2 is offered with only one type of surface passivation:<br />
The very best.<br />
1<br />
1<br />
GRAPHPACK 3D/2<br />
ferrule<br />
3<br />
GRAPHPACK 3D/2<br />
screw<br />
2<br />
The GRAPHPACK 3D/2 ferrule<br />
is a cylinder metal packed with<br />
graphite.<br />
Advantages<br />
● Suitable for high pressures and temperatures<br />
as well as high vacuum.<br />
● Rapid mounting and positioning on<br />
the column outside the oven.<br />
● Leak-free connections are achieved<br />
without excessive tightening.<br />
● Connections remain leak-free with<br />
temperature cycling.<br />
● Self-centering of the ferrule in the<br />
connector.<br />
4<br />
The screw secures the<br />
capillary column and the<br />
GRAPHPACK 3D/2 ferrule in<br />
the connector.<br />
GRAPHPACK 3D/2 sealing<br />
ferrule<br />
This is a GRAPHPACK 3D/2 ferrule<br />
with a fixed sealing wire for the low<br />
dead-volume sealing of an<br />
outlet which is not needed on<br />
GRAPHPACK 3D/2 crosspieces<br />
and switching in use.<br />
3<br />
4<br />
2<br />
GRAPHPACK 3D/2<br />
connectors<br />
Column connectors, crosspieces<br />
and switching devices for the<br />
connection of two to four capillary<br />
columns of the same or different<br />
diameters.<br />
Advantages<br />
● No dead volume occurs as the<br />
result of an outlet which is not<br />
needed.<br />
● No graphite enters the<br />
GRAPHPACK 3D/2 crosspiece or<br />
switching device as an appropriate<br />
sealing ferrule is available for every<br />
column diameter.<br />
Advantages<br />
● Low thermal mass.<br />
● Low dead-volume.<br />
16<br />
GRAPHPACK 2M and GRAPHPACK 3D/2 ferrules<br />
are not interchangeable.
GRAPHPACK ® 17<br />
Column OD / ID<br />
Part No.<br />
GRAPHPACK 3D/2 ferrules<br />
1 package (10 units)<br />
0.20 mm / 0.1 mm 001705-020-00<br />
0.25 mm / 0.1 mm 001705-025-00<br />
0.31 mm / 0.20 mm 001705-031-00<br />
0.40 mm / 0.25 mm 001705-040-00<br />
0.45 mm / 0.32 mm 001705-045-00<br />
0.70 mm / 0.53 mm 001705-007-00<br />
0.80 mm / 0.<strong>27</strong> mm 001705-008-00<br />
(glass capillary)<br />
GRAPHPACK 3D/2 screw<br />
1 package (1 units)<br />
0.20 mm / 0.1 mm 005615-020-00<br />
0.25 mm / 0.1 mm 005615-025-00<br />
0.31 mm / 0.20 mm 005615-031-00<br />
0.40 mm / 0.25 mm 005615-040-00<br />
0.45 mm / 0.32 mm 005615-045-00<br />
0.70 mm / 0.53 mm 005615-007-00<br />
0.80 mm / 0.<strong>27</strong> mm 005615-008-00<br />
(glass capillary)<br />
GRAPHPACK 3D/2 sealing<br />
ferrule for GRAPHPACK 3D/2<br />
crosspieces<br />
1 package (5 units)<br />
0.20 mm / 0.1 mm 006520-020-00<br />
0.25 mm / 0.1 mm 006520-025-00<br />
0.31 mm / 0.20 mm 006520-031-00<br />
0.40 mm / 0.25 mm 006520-040-00<br />
0.45 mm / 0.32 mm 006520-045-00<br />
0.70 mm / 0.53 mm 006520-007-00<br />
0.80 mm / 0.<strong>27</strong> mm 006520-008-00<br />
(glass capillary)
Part No.<br />
GRAPHPACK ® 3D/2 column connector Sulfinert ®<br />
For the connection of two capillary columns with the<br />
same or different diameters or of different materials.<br />
Column OD / ID<br />
Column OD / ID<br />
Part No.<br />
from 0.70 / 0.53 mm to<br />
0.31 mm / 0.20 mm 013407-031-00<br />
0.40 mm / 0.25 mm 013407-040-00<br />
0.45 mm / 0.32 mm 013407-045-00<br />
0.70 mm / 0.53 mm 013407-007-00<br />
from 0.45 / 0.32 mm to<br />
0.31 mm / 0.20 mm 013445-031-00<br />
0.40 mm / 0.25 mm 013445-040-00<br />
0.45 mm / 0.32 mm 013445-045-00<br />
from 0.40 / 0.25 mm to<br />
0.40 mm / 0.25 mm 013440-040-00<br />
from 0.31 / 0.20 mm to<br />
0.31 mm / 0.20 mm 013431-031-00<br />
GRAPHPACK 3D/2 column connector Sulfinert ®<br />
with gas connection<br />
GRAPHPACK 3D/2 column connector with gas connection<br />
For the connection of two capillary columns with the same<br />
or different diameters or of different materials and the<br />
connection of make-up gas.<br />
Column OD / ID<br />
Column OD / ID<br />
Spare parts<br />
see page 17<br />
Part No.<br />
from 0.80 to<br />
0.45 mm / 0.32 mm 013508-045-00<br />
from 0.70 / 0.53 mm to<br />
0.31 mm / 0.20 mm 013507-031-00<br />
0.40 mm / 0.25 mm 013507-040-00<br />
0.45 mm / 0.32 mm 013507-045-00<br />
0.70 mm / 0.53 mm 013507-007-00<br />
from 0.45 / 0.32 mm to<br />
from 0.40 / 0.25 mm to<br />
0.31 mm / 0.20 mm 013545-031-00<br />
0.40 mm / 0.25 mm 013545-040-00<br />
0.45 mm / 0.32 mm 013545-045-00<br />
0.40 mm / 0.25 mm 013540-040-00<br />
from 0.31 / 0.20 mm to<br />
0.31 mm / 0.20 mm 013531-031-00<br />
18<br />
GRAPHPACK 3D/2 column connectors with or without one gas connection<br />
include two GRAPHPACK 3D/2 ferrules.
GRAPHPACK ® 19<br />
Part No.<br />
GRAPHPACK 3D/2 crosspieces Sulfinert ®<br />
For the connection up to 4 capillary columns with<br />
the same or different diameters or of different materials.<br />
main column<br />
outside diameter<br />
Part No.<br />
GRAPHPACK 3D/2<br />
crosspiece kit<br />
contains<br />
GRAPHPACK 3D/2 crosspiece<br />
GRAPHPACK 3D/2 ferrules<br />
Universal bracket for crosspiece<br />
GRAPHPACK mounting tool kit<br />
0.31 mm 012224-031-00<br />
0.45 mm 012224-045-00<br />
0.70 mm 012224-007-00<br />
Spare parts<br />
GRAPHPACK 3D/2 crosspiece 0.31 mm 012240-031-00<br />
0.40 mm 012240-040-00<br />
0.45 mm 012240-045-00<br />
0.70 mm 012240-007-00<br />
Universal bracket for crosspiece<br />
006188-000-00<br />
1<br />
1<br />
GRAPHPACK mounting tool kit<br />
for GRAPHPACK 3D/2 column<br />
connectors + crosspieces<br />
Complete kit 013492-000-00<br />
Spare parts<br />
2<br />
GRAPHPACK mounting tool<br />
tool body without insert<br />
003424-000-00<br />
2<br />
3<br />
Insert for 1.2 mm<br />
column mounting depth<br />
Color red 008994-003-00<br />
4<br />
Insert holder<br />
main column<br />
outside diameter<br />
0.20 mm to 0.31 mm 008995-031-00<br />
3<br />
4<br />
0.40 mm to 0.45 mm 008995-045-00<br />
0.70 mm to 0.80 mm 008995-008-00
GERSTEL ® Cooled Injection System, CIS<br />
Part No.<br />
Universal inlet for gas chromatography<br />
The GERSTEL CIS is a temperature<br />
programmable GC inlet. The CIS offers<br />
septumless, cold injection of volumes<br />
of up to 1000 µl for liquid samples. The<br />
integrated split function enables the CIS to<br />
handle ultra-trace concentrations as well<br />
as undiluted samples. Programmed linear<br />
heating ensures quantitative, discrimination-free<br />
transfer of sample components<br />
to the GC column for best possible GC<br />
analysis results.<br />
The CIS is a general purpose, universal<br />
GC inlet. When working with Thermal<br />
Desorption or Headspace techniques,<br />
the CIS is used for enrichment, focusing<br />
and quantitative transfer of analytes to the<br />
capillary column.<br />
An integral part of the CIS is the<br />
GERSTEL MAS controller, which can be<br />
used to control all GERSTEL modules,<br />
thus ensuring easy, cost effective system<br />
upgrades. The CIS can be retrofitted to<br />
existing Agilent Technologies/HP gas<br />
chromatographs.<br />
GERSTEL GRAPHPACK ® technology and<br />
septumless sampling head are standard<br />
features. A choice of liquid CO2, liquid N2<br />
or Peltier cooling is available. Available<br />
CIS models cover the temperature range<br />
from –150 to +600 °C. Compounds<br />
covering a wide boiling range can be<br />
efficiently trapped with subsequent<br />
discrimation-free analyte transfer to the<br />
capillary column. The CIS is compatible<br />
with all GERSTEL autosamplers - and<br />
with autosamplers from all major manufacturers.<br />
20
GERSTEL ® Cooled Injection System, CIS<br />
Part No.<br />
Septumless sampling head (SLH)<br />
for CIS 3 / 4 / 6<br />
(for 23 gauge needles)<br />
For manual or auto-injection<br />
CIS 3 003089-064-00<br />
CIS 4 / CIS 6 007513-064-00<br />
Service kit for SLH<br />
Complete<br />
009999-010-00<br />
3<br />
Contains one unit each of the following items:<br />
1 Plunger 004230-000-00<br />
2 Spring 009999-014-00<br />
3 Inner-O-Ring (Kalrez) 009999-015-00<br />
4 Outer-O-Ring (Viton) * 009999-016-00<br />
2<br />
1<br />
* When reordering only complete original package size is available (5 units).<br />
4<br />
SLH cap<br />
23 gauge needles 006144-064-00<br />
Teflon needle guide for SLH<br />
1 package (10 units)<br />
23 gauge needles 003091-064-00<br />
Carrier gas connection<br />
for SLH<br />
1<br />
4<br />
Complete kit 005610-000-00<br />
2<br />
1<br />
2<br />
3<br />
4<br />
Aluminium seal for SLH 1 package (5 units) 004256-005-00<br />
Screw 1 package (1 units) 001459-003-00<br />
Teflon ferrule 1/16” 1 package (10 units) 001576-010-00<br />
Knurled nut 1 package (5 units) 001117-005-00<br />
3<br />
21
Column OD / ID<br />
Part No.<br />
GRAPHPACK ® 2M adapter<br />
for CIS<br />
CIS 3 / CIS 4<br />
(silver)<br />
0.31 mm / 0.20 mm 007259-031-00<br />
0.45 mm / 0.32 mm 007259-045-00<br />
0.70 mm / 0.53 mm 007259-007-00<br />
Spare parts<br />
CIS 6<br />
(Stainless steel)<br />
0.31 mm / 0.20 mm 013244-031-00<br />
0.45 mm / 0.32 mm 013244-045-00<br />
0.70 mm / 0.53 mm 013244-007-00<br />
Silver seal; 1 package (5 units) 002841-005-00<br />
GRAPHPACK nut; 1 package (5 units) 001268-005-00<br />
Septum head<br />
without septum purge<br />
CIS 3 002835-000-00<br />
CIS 4 / CIS 6 007514-000-00<br />
Septum head<br />
with septum purge<br />
CIS 3 008577-000-00<br />
CIS 4 / CIS 6 008584-000-00<br />
1<br />
Spare parts<br />
2<br />
1<br />
Septum cap 006460-000-00<br />
2<br />
Septum for CIS 3/4, white; 1 package (25 units) 008246-025-00<br />
3<br />
Teflon ferrule 1/16”; 1 package (10 units) 001576-010-00<br />
3<br />
4<br />
Knurled nut; 1 package (5 units) 001117-005-00<br />
4<br />
Adsorption trap<br />
for split outlet<br />
1/16“ inlet, 1/16“ outlet connection,<br />
filled with charcoal<br />
005243-001-00<br />
22
GERSTEL ® Cooled Injection System, CIS<br />
Column OD / ID<br />
Part No.<br />
GRAPHPACK ® 2M dual column<br />
injector adapter<br />
For the simultaneous connection of two<br />
analytical capillary columns to a single CIS<br />
inlet.<br />
0.31 mm / 0.20 mm 007530-031-00<br />
0.45 mm / 0.32 mm 007530-045-00<br />
Spare parts<br />
Silver seal; 1 package (5 units) 002841-005-00<br />
GRAPHPACK nut; 1 package (5 units) 003714-005-00<br />
On Column kit<br />
1<br />
On Column insert; single CIS 3 005532-000-00<br />
CIS 4 / CIS 6 008339-000-00<br />
2<br />
GRAPHPACK 3D ferrule; CIS 3 002426-005-00<br />
1 package (5 units) CIS 4 / CIS 6 007541-005-00<br />
1<br />
2<br />
3<br />
GRAPHPACK 2M adapter CIS 3 / CIS 4 007259-007-00<br />
CIS 6 013244-007-00<br />
4<br />
GRAPHPACK 2M ferrule; 1 package (10 units) 001805-007-00<br />
4<br />
3<br />
5<br />
Silver seal; 1 package (5 units) 002841-005-00<br />
6<br />
Teflon needle guide (0.47 mm); 1 package (10 units) 003091-047-00<br />
5<br />
7<br />
Cap (0.47 mm) 006144-047-00<br />
6<br />
7<br />
23
Part No.<br />
Glass liners for CIS<br />
Part No.<br />
Part No.<br />
packed * deactivated description / typical use units CIS 3 CIS 4 / CIS 6 **<br />
– straight with notch 10 011708-010-00 011709-010-00<br />
Initial system checkout; user custom-packed<br />
liners; hot split/splitless injections<br />
– baffled 10 011710-010-00 011711-010-00<br />
General use liquid injection for<br />
moderate/high boilers, labile compounds,<br />
split injections<br />
– for SPME ID 1mm 10 – 011712-010-00<br />
for injection with MPS 2 with SPME Option<br />
with liquid injection for moderate/high boilers, 10 010849-010-00 010850-010-00<br />
silanized<br />
stable compounds; thermal desorption<br />
glass wool<br />
cryotrapping of stable compounds<br />
with More inert than glass wool; used for trapping 10 008420-010-00 007519-010-00<br />
quartz wool<br />
labile compounds<br />
with glass Provides additional surface area compared 5 – 011714-005-00<br />
beads<br />
to empty liner<br />
with glass beads Trapping volatiles with a wide range of 5 – 011716-005-00<br />
and Carbotrap C<br />
boiling points<br />
with Tenax TA Trapping of C 5 and higher volatiles 5 013249-005-00 013247-005-00<br />
(– 50 °C minimum temperature)<br />
with Carbotrap B Trapping of low boiling volatiles 5 013250-005-00 013248-005-00<br />
– straight with notch 10 002425-010-00 013881-010-00<br />
Initial system checkout; user custom-packed<br />
liners; hot split/splitless injections<br />
– baffled 10 002930-010-00 013882-010-00<br />
General use liquid injection for<br />
moderate/high boilers, labile compounds,<br />
split injections<br />
– ID 2 mm 10 – 013910-010-00<br />
for special applications<br />
with General use liquid injection for moderate/ 10 002931-010-00 014284-010-00<br />
silanized<br />
high boilers, stable compounds; thermal<br />
glass wool<br />
desorption cryotrapping of stable compounds<br />
Quartz liners<br />
Part No.<br />
packed * deactivated description / typical use units CIS 4 / CIS 6<br />
– – straight with notch 1 013238-000-00<br />
For hot split/splitless injection to 650°C 5 013238-005-00<br />
– – baffled 1 013148-000-00<br />
General se liquid injection for moderate/ 5 013148-005-00<br />
high boilers, labile compounds,<br />
split injections to 650 °C<br />
with – Used for trapping labile compounds 1 013605-000-00<br />
quartz wool 5 013605-005-00<br />
24<br />
*<br />
**<br />
All packed liners use the „straight with notch“ liner.<br />
These glass liners are to be used to 450 °C only when working with a CIS 6. For higher temperatures<br />
than 450 °C only quartz liners are allowed !
GERSTEL ® Cooled Injection System, CIS<br />
Part No.<br />
Glass liner kits<br />
consisting of:<br />
Part No.<br />
Part No.<br />
units CIS 3 CIS 4 / CIS 6 **<br />
• straight with notch, deactivated 2 013543-003-00 013543-004-00<br />
• baffled, deactivated 2<br />
• packed with silanized glass wool, deactivated 2<br />
• packed with Tenax 2<br />
• packed with Carbopack B 2<br />
GRAPHPACK ® 3D ferrules for glass liners<br />
1 package (5/10 units)<br />
Part No.<br />
Part No.<br />
units CIS 3 CIS 4 / CIS 6 **<br />
5 002426-005-00 007541-005-00<br />
10 002426-010-00 007541-010-00<br />
Kalrez ferrule (not in conjunction with TDS / TDU)<br />
Part No.<br />
Part No.<br />
units CIS 3 CIS 4 / CIS 6 **<br />
2 - 011868-002-00<br />
GRAPHPACK 3D mounting tool<br />
for glass liners<br />
CIS 3 003079-000-00<br />
CIS 4 / CIS 6 007542-000-00<br />
Cryo tube<br />
2 m<br />
CIS 4 / CIS 6<br />
with CIS adapter 006124-004-00<br />
CIS 4 / CIS 6<br />
1/4 “ Swagelok ® 006124-020-00<br />
25
Part No.<br />
Microliter syringes<br />
injection type system description µL units Part No.<br />
manual injection CIS fixed needle 5 1 009980-040-00<br />
10 1 009996-059-00<br />
25 1 009970-010-00<br />
50 1 009970-011-00<br />
100 1 009970-012-00<br />
manual injection CIS gastight 100 1 009999-019-00<br />
250 1 009999-018-00<br />
500 1 009999-017-00<br />
1000 1 009999-021-00<br />
Spare<br />
TLL needle 3 009999-006-00<br />
26
GERSTEL ® Cooled Injection System, CIS<br />
Part No.<br />
Microliter syringes<br />
injection / sampler system description µL units Part No.<br />
manual injection CIS needle-in-needle 1 1 009999-041-00<br />
Autosampler CIS fixed needle 5 1 009980-028-00<br />
HP 7673 / 5 6 009980-029-00<br />
Agilent 7683 10 1 009980-030-00<br />
10 6 009980-031-00<br />
Autosampler CIS replaceable needle 25 1 009980-032-00<br />
HP 7673 / 50 1 009970-013-00<br />
Agilent 7683 100 1 009970-014-00<br />
Spare<br />
needle 2 009980-033-00<br />
Autosampler CIS fixed needle, 10 1 009999-052-00<br />
HP 7673 /<br />
on-column-injection<br />
Agilent 7683<br />
<strong>27</strong>
Part No.<br />
GERSTEL ®<br />
Automated Liner EXchange, ALEX<br />
For routine GC analysis of samples, that contain large amounts of solid<br />
material. Designed for use with the GERSTEL MultiPurpose Sampler,<br />
MPS 2 and the GERSTEL Cooled Injection System, CIS. GC inlet liners<br />
can be replaced automatically at user-defined intervals in the sequence.<br />
A special ALEX liner tray holds up to 98 prepared liners, enabling<br />
routine analysis of large numbers of dirty samples.<br />
Part No.<br />
Universal syringe holder<br />
Version 2; compatible with ALEX<br />
013822-000-00<br />
ALEX transportion adapter<br />
for CIS 4 Liner<br />
1 units 013795-000-00<br />
10 units 013795-010-00<br />
O ring kit for ALEX<br />
transport adapter<br />
1 package (5 × 4 units)<br />
013934-005-00<br />
28
GERSTEL ® Automated Liner EXchange, ALEX<br />
Part No.<br />
Septa<br />
Ice blue, for liquid injection,<br />
5 mm, 1 package (100 units)<br />
014052-100-00<br />
Allen wrench<br />
for transport adapter screws, 4 mm<br />
009999-204-00<br />
O ring<br />
for ALEX sampling head,<br />
1 package (10 units)<br />
013931-010-00<br />
Glass inserts for ALEX sample tray<br />
10 units 013794-010-00<br />
100 units 013794-100-00<br />
O ring for ALEX sample<br />
tray glass inserts<br />
10 units 014292-010-00<br />
100 units 014292-100-00<br />
29
GERSTEL ® MultiPurpose Sampler, MPS 2<br />
Part No.<br />
The GERSTEL MultiPurpose Sampler,<br />
MPS 2 is a highly flexible and productive<br />
autosampler and sample preparation robot<br />
for GC and GC/MS analysis. The MPS 2<br />
can automate everything from sample<br />
preparation to sample introduction. The<br />
MPS 2 is easily adapted to both new<br />
and existing instruments. The system is<br />
installed on top of the GC, saving valuable<br />
bench space, and is compatible with all<br />
standard laboratory GC systems.<br />
GERSTEL MASter Software enables<br />
integrated control of the MPS 2 and a<br />
GC or GC-MS system from one method<br />
and one integrated sequence list through<br />
the Agilent ® Technologies ChemStation<br />
Software.<br />
The GERSTEL MPS PrepStation is a<br />
dual-rail/dual robot configuration of the<br />
MPS 2 MultiPurpose Sampler.<br />
The PrepStation performs fully<br />
automated sample preparation and<br />
sample introduction. One MPS rail of<br />
the MPS PrepStation is an automated<br />
liquid sample handler that performs<br />
a wide range of sample preparation<br />
functions. The second MPS rail enables<br />
many automated sample introduction<br />
options, including Headspace and SPME<br />
depending upon the selected MPS 2<br />
hardware configuration.<br />
The GERSTEL PrepBuilder Software<br />
enables overlapping sample preparation<br />
and GC analysis. While GC separation<br />
is in progress, the next sample is being<br />
prepared for analysis ensuring maximum<br />
productivity.<br />
Automated sample preparation<br />
steps include:<br />
• Dilution<br />
• Derivatization<br />
• Heating<br />
• Rinsing<br />
• Liquid-liquid extraction<br />
• Standard addition<br />
• Spiking<br />
• Agitation<br />
Automated sample introduction using a<br />
wide range of selectable techniques:<br />
• Standard liquid injection<br />
• Large-volume liquid injection<br />
• Headspace<br />
• SPME<br />
• Twister ® Option<br />
• Twister back-extraction<br />
• Membrane assisted solvent extraction<br />
Other techniques can be automated using<br />
the MPS 2 with special adaptations.<br />
MPS 2<br />
30
GERSTEL ® MultiPurpose Sampler, MPS<br />
Part No.<br />
Sample vials and caps for use with the MPS 2, MPS 2L,<br />
MPS 2XL and MPS PrepStation<br />
1<br />
Crimp cap vials<br />
Sampler Type Vials mL units Part No.<br />
MPS 2 Clear, colorless glass 0.7 100 093640-052-00 *<br />
2 100 1 093640-004-00<br />
10 100 2 093640-005-00<br />
20 100 3 093640-006-00<br />
100 100 093640-062-00<br />
2<br />
Crimp caps with septum for vials<br />
If vials need to be reopened and emptied after analysis,<br />
magnetic vial caps with aluminum edges (Bi-metal) offer<br />
the best solution. The softer edges allow easy crimping and<br />
decrimping using a hand-crimper. If steel caps are used, it is<br />
recommended to use a bench-top crimper.<br />
3<br />
Sampler Type Caps Vial volume (mL) units Part No.<br />
MPS 2<br />
Aluminium with septum<br />
PTFE red / Silicone / PTFE red,<br />
for 8 mm vial 0.7 100 093640-053-00<br />
*<br />
Magnetic, golden with septum<br />
PTFE red / Silicone / PTFE red,<br />
for 11 mm vial 2 100 093640-007-00<br />
Magnetic, golden,<br />
Silicone blue transparent, 10/20 100 093640-008-00<br />
PTFE white, 3 mm, for 20 mm vial 10/20 1000 093640-015-00<br />
Bi-metall, magnetic, red, with septum<br />
Silicone blue transparent,<br />
PTFE white, 3 mm, for 20 mm vial 10/20 100 093640-063-00<br />
Magnetic, with Pharma Fix septum<br />
Silicone/PTFE 10/20 100 093640-064-00<br />
Delivery times upon request *<br />
31
Part No.<br />
Vials for SPME<br />
Special vial with thickened crimp neck for use with 20 mm cap 100 units 093640-035-00<br />
for SPME and 0.5 mm septa, with imprint »SPME«<br />
Crimp caps for SPME<br />
magnetic, golden, with septum<br />
For SPME applications, crimp caps of steel with silicone septa are recommended. If the sample is<br />
analyzed for silicone, it is recommended to use butyl rubber septa or natural rubber septa. For a leakfree<br />
seal, it is recommended to use a bench-top crimper.<br />
Sampler Crimp cap with septum: Vial volume (mL) units Part No.<br />
MPS 2<br />
Silicone creme, PTFE red, 1.5 mm,<br />
55° Shore A, for 20 mm SPME vial 20 100 093640-031-00<br />
Viton, 0.5 mm,<br />
75° Shore A, for 20 mm SPME vial 20 100 093640-032-00<br />
Natural rubber, red-orange / Teflon, 1.3 mm,<br />
55° Shore A, for 20 mm SPME vial 20 100 093640-034-00<br />
Butyl red / PTFE grey, 1.3 mm,<br />
55° Shore A, for 20 mm SPME vial 20 100 093640-050-00<br />
Screw neck vials<br />
Sampler Vials Vial volume (mL) units Part No.<br />
MPS 2 clear, incl. caps and septa, 11 mm 2 100 089355-076-00<br />
clear, for 18 mm screw caps 10 100 093640-038-00<br />
brown, for 18 mm screw caps; 20 100 093640-037-00<br />
without caps and septa<br />
clear, for 18 mm screw caps; 20 100 093640-036-00<br />
without caps and septa<br />
brown, for 18 mm screw caps; 10 100 093640-039-00<br />
without caps and septa<br />
Microliter inserts, clear,<br />
for 2 mL screw cap vials 0.1 100 093640-029-00<br />
Screw caps with septa<br />
magnetic, for 18 mm screw cap vials<br />
Caps with silicone septa, blue, transparent are recommended as standard. If the sample is<br />
analyzed for silicone, it is recommended to use screw-caps with butyl rubber septa or viton septa.<br />
Sampler Screw caps with septum Vial volume (mL) units Part No.<br />
MPS 2<br />
Silicone blue transparent / PTFE white,<br />
1.3 mm, 35° Shore A 10/20 100 093640-040-00<br />
Silicone white / PTFE blue,<br />
1.5 mm, 60° Shore A 10/20 100 093640-041-00<br />
Viton black,<br />
1.0 mm, 75° Shore A 10/20 100 093640-043-00<br />
Butyl red / PTFE grey,<br />
1.6 mm, 55° Shore A 10/20 100 093640-042-00<br />
32
GERSTEL ® MultiPurpose Sampler, MPS<br />
Part No.<br />
Part No.<br />
Septa for screw caps for 10/20 mL screw cap vials<br />
Sampler Septum type units Part No.<br />
MPS 2 Silicone blue transparent / PTFE white, 1.3 mm, 35° Shore A 100 093640-057-00<br />
Silicone white / PTFE blue, 1.5 mm, 60° Shore A 100 093640-056-00<br />
Viton black, 1.0 mm, 75° Shore A 100 093640-059-00<br />
Butyl red / PTFE grey, 1.6 mm, 55° Shore A 100 093640-058-00<br />
Screw cap vials for Twister ® Back Extraction<br />
Sampler Vials Vial volume (mL) units Part No.<br />
MPS 2<br />
for 10 mm Twisters:<br />
screw cap vial 32 x 11.6 mm,<br />
clear, for 11 mm screw cap 1.5 100 093640-046-00<br />
for 10 mm Twisters:<br />
insert 31 x 6 mm, clear 0.2 100 093640-047-00<br />
for 20 mm Twisters:<br />
screw cap vial 32 x 11.6 mm,<br />
clear, for 11 mm screw cap 1.1 100 093640-045-00<br />
Screw caps, blue, with septa, 9 mm.<br />
With embedded magnetic discs.<br />
septum: silicone, white / PTFE, red,<br />
1.0 mm, 55° Shore A. 1 package (100 units) 093640-048-00<br />
Inserts 2 mL, for Agitator<br />
1 package (6 units)<br />
For automated Twister Back Extraction<br />
analysis, 2 mL vials are transferred to the<br />
agitator. This requires special adaptors inside<br />
the agitator.<br />
093631-002-00<br />
*<br />
Delivery times upon request *<br />
33
Part No.<br />
Replacement kit for<br />
Standard wash station<br />
MPS 2 or MPS 2L<br />
consisting of:<br />
10 mL 10CV vials (10 units)<br />
wash cap Polypropylene Snap Cap (10 units)<br />
20-ST101 Silicone/PTFE Septa (10 units)<br />
093632-050-00 *<br />
Solvent bottle 100 mL<br />
includes cap and septum<br />
093631-054-00<br />
Caps and septa<br />
for 100 mL solvent bottle,<br />
1 package (10 units)<br />
093631-055-00<br />
Crimper<br />
for 8 mm crimp caps (0.7 mL vials) 093640-054-00 *<br />
for 11 mm crimp caps (2 mL vials) 093640-000-00<br />
for 20 mm crimp caps (10/20 mL vials) 093640-001-00<br />
Decapper<br />
for 8 mm crimp caps (0.7 mL vials) 093640-053-00 *<br />
for 11 mm crimp caps (2 mL vials) 093640-002-00<br />
for 20 mm crimp caps (10/20 mL vials) 093640-003-00<br />
34<br />
Delivery times upon request *
GERSTEL ® MultiPurpose Sampler, MPS<br />
Part No.<br />
Part No.<br />
Bench-top crimper<br />
For easy crimping and de-crimping<br />
of vials, especially when steel caps<br />
are used or when large numbers of<br />
samples are analyzed.<br />
1<br />
1<br />
for crimp caps 20 mm 093640-009-00<br />
Spare parts / Option<br />
2<br />
Crimper head<br />
Decapper head<br />
Vial guide<br />
for crimp caps<br />
8 mm (0.7 mL vials) 093640-020-00 *<br />
11 mm (2 mL vials) 093640-017-00 *<br />
13 mm (4 mL vials) 093640-023-00 *<br />
20 mm (10/20 mL vials) 093640-010-00 *<br />
8 mm (0.7 mL vials) 093640-021-00 *<br />
11 mm (2 mL vials) 093640-018-00 *<br />
13 mm (4 mL vials) 093640-024-00 *<br />
8 mm (0.7 mL vials) 093640-022-00 *<br />
11 mm (2 mL vials) 093640-019-00 *<br />
13 mm (4 mL vials) 093640-025-00 *<br />
20 mm (10/20 mL vials) 093640-012-00 *<br />
2<br />
Microliter syringe<br />
For MPS 2, MPS 2L and MPS PrepStation, for use with CTC syringe adapter<br />
The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and are<br />
compatible with the GERSTEL ® Septumless Head (SLH). Needles have<br />
conical tips (type C or AS).<br />
1<br />
OD x L (mm)<br />
volume (µL) gastight needle needle dimension units<br />
5 – fixed 0.63 x 50 1 1 009970-001-00<br />
10 – fixed 0.63 x 50 1 009970-002-00<br />
25 fixed 0.63 x 50 1 009970-004-00<br />
100 replaceable 0.63 x 50 1 2 009970-005-00<br />
250 replaceable 0.63 x 50 1 009970-006-00<br />
2<br />
Spare<br />
needles for 100/250 µL syringe 2 009970-007-00<br />
Delivery times upon request *<br />
35
Part No.<br />
Microliter syringes<br />
For MPS 2, MPS 2L and MPS PrepStation, for use with the GERSTEL ®<br />
Universal liquid syringe adapter<br />
The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and are<br />
compatible with the GERSTEL Septumless Head (SLH). Needles have<br />
conical tips (type C or AS).<br />
needle dimensions<br />
volume (µL) gastight needle OD x L (mm) units Part No.<br />
1.2 – needle-in-needle 0.47 x 51.0 1 093611-010-00<br />
5 – fixed 0.63 x 51.7 1 009970-021-00<br />
10 – fixed 0.63 x 51.5 1 009970-024-00<br />
10 fixed 0.63 x 51.5 1 009970-022-00<br />
10 – fixed 0.47 x 51.5 1 009970-058-00<br />
5 – replaceable 0.63 x 51.5 1 009970-015-00<br />
10 replaceable 0.63 x 51.5 1 009970-016-00<br />
100 replaceable 0.63 x 52.0 1 009970-018-00<br />
250 replaceable 0.63 x 52.0 1 009970-019-00<br />
1000 replaceable 0.63 x 53.5 1 009970-020-00<br />
Replacement syringe plungers (gastight)<br />
10 µL syringe with fixed needle 1 009970-030-00<br />
10 µL syringe with replaceable needle 1 009970-031-00<br />
100 µL syringe with replaceable needle 1 009970-032-00<br />
250 µL syringe with replaceable needle 1 009970-033-00<br />
1000 µL syringe with replaceable needle 1 009970-034-00<br />
Replacement needles<br />
5 µL syringe with replaceable needle 2 009970-048-00<br />
10 µL syringe with replaceable needle 2 009970-040-00<br />
100/250 µL syringe with replaceable needle 2 009970-041-00<br />
1000 µL syringe with replaceable needle 2 009970-042-00<br />
On column needle<br />
10 µL syringe with replaceable needle 2 009970-043-00<br />
36
GERSTEL ® MultiPurpose Sampler, MPS<br />
Part No.<br />
Part No.<br />
Microliter syringe<br />
for MPS 2, MPS 2L, MPS 2XL and MPS PrepStation<br />
For use with GERSTEL ® Universal Headspace Syringe Adapter in<br />
combination with heated adapter for liquid injection.<br />
The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and are<br />
compatible with the GERSTEL Septumless Head (SLH). Needles have<br />
conical tips (type C or AS).<br />
needle dimensions<br />
volume (µL) gastight needle OD x L (mm) units Part No.<br />
10 – replaceable 0.63 x 54.2 1 009970-051-00<br />
10 – fixed 0.63 x 54.2 1 009970-057-00<br />
Replacement needle for<br />
10 µL syringe with needle 2 009970-052-00<br />
For use with the GERSTEL Universal Headspace Syringe<br />
Adapter<br />
The listed syringes all have 23 Gauge needles (OD = 0.63 mm) and<br />
are compatible with the GERSTEL Septumless Head (SLH). Needles<br />
have conical tips (type H or 5).<br />
OD x L (mm)<br />
volume [mL] gastight needle needledimension units Part No.<br />
1 replaceable 0.63 x 57.0 1 009980-045-00<br />
2.5 replaceable 0.63 x 57.0 1 009980-044-00<br />
Replacement syringe plungers (gastight)<br />
1 mL headspace syringe 1 009980-047-00<br />
2.5 mL headspace syringe 1 009980-048-00<br />
Replacement needle<br />
1-/2.5 mL headspace syringe 2 009980-046-00<br />
37
Part No.<br />
Dilutor module for<br />
MPS 2, MPS 2 XL and MPS PrepStation<br />
MPS 2 Dilutor syringe<br />
For use with the MPS Dilutor module<br />
volume units Part No.<br />
MPS Dilutor syringe 1 mL 1 093631-091-00<br />
2.5 mL 1 093631-092-00<br />
5 mL 1 093631-093-00<br />
10 mL 1 093631-094-00<br />
Replacement plunger for MPS Dilutor syringe<br />
1 mL 1 093632-038-00<br />
2.5 mL 1 093632-039-00<br />
5 mL 1 093632-040-00<br />
10 mL 1 093632-041-00<br />
PTFE seal for MPS Dilutor syringe 1 093632-045-00 *<br />
Solvent bottle for MPS Dilutor; 1000 mL 1 093632-043-00 *<br />
*<br />
*<br />
*<br />
*<br />
MPS 2 Sideport syringe without needle<br />
For use with MPS sideport syringe adapter (not<br />
compatible with GERSTEL ® Universal Syringe Adapter)<br />
volume units Part No.<br />
MPS Sideport syringe<br />
without needle 20 µL 1 093631-096-00<br />
80 µL 1 093631-095-00<br />
Replacement plunger<br />
for Sideport syringe 20 µL 10 093611-034-00 *<br />
80 µL 10 093611-0<strong>27</strong>-00 *<br />
Needles<br />
Needles for use with MPS 2, MPS 2L, MPS XL and MPS PrepStation.<br />
For use with GC injectors.<br />
23s gauge (OD = 0.63 mm) needle for 20 µL syringe 3 093611-033-00<br />
26 gauge (OD = 0.47 mm) needle for 20 µL syringe 3 093611-029-00<br />
23 gauge (OD = 0.63 mm) needle for 80 µL syringe 3 093611-032-00<br />
26 gauge (OD = 0.47 mm) needle for 80 µL syringe 3 093611-028-00<br />
26 gauge needles are compatible with on-column injection.<br />
38<br />
Delivery times upon request *
GERSTEL ® MultiPurpose Sampler, MPS<br />
Part No.<br />
SPME fiber holder<br />
Designed for mounting SPME fibers for<br />
automated SPME analysis.<br />
093639-000-00<br />
Fibers used for automated SPME analysis have no spring<br />
– in contrast to fibers for manual SPME. Consequently,<br />
there are separate holders for each fiber type. The fibers<br />
listed here are designed exclusively for automated SPME<br />
analysis using the MPS 2. They are not suitable for manual<br />
SPME analysis.<br />
For use with the GERSTEL ® Cooled Injection System, CIS<br />
23 gauge (OD=0.63 mm) fibers and SPME liner are<br />
recommended.<br />
SPME fiber kits<br />
volatiles<br />
100 µm polydimethylsiloxane, non-bonded<br />
non-polar semivolatiles<br />
30 µm polydimethylsiloxane, non-bonded<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639 001-00<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-003-00<br />
non-polar high molecular weight compounds<br />
7 µm polydimethylsiloxane, bonded<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-004-00<br />
volatiles, amines, and nitroaromatic compounds<br />
65 µm polydimethylsiloxane/divinylbenzene,<br />
partially crosslinked<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-005-00<br />
volatiles, amines, and nitroaromatic compounds<br />
65 µm polydimethylsiloxane/divinylbenzene,<br />
highly crosslinked on StableFlex fiber<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-022-00<br />
semivolatiles<br />
85 µm polyacrylate, partially crosslinked<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-023-00<br />
39
Part No.<br />
SPME fiber kits<br />
gases and low molecular compounds<br />
75 µm carboxen/polydimethylsiloxane,<br />
partially crosslinked<br />
gases and low molecular compounds<br />
85 µm carboxen/polydimethylsiloxane,<br />
highly crosslinked on StableFlexTM fiber<br />
alcohols and polar compounds<br />
65 µm carbowax/divinylbenzene,<br />
partially crosslinked<br />
alcohols and polar compounds<br />
70 µm carbowax/divinylbenzene,<br />
highly crosslinked on StableFlexTM fiber<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-009-00<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-024-00<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-025-00<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-013-00<br />
volatiles and semivolatiles<br />
85 µm polyacrylate, 100 µm polydimethylsiloxane,<br />
7 µm polydimethylsiloxane coating<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-028-00<br />
flavors<br />
50/30 µm divinylbenzene/carboxen/<br />
polydimethylsiloxane on StableFlex fiber<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-026-00<br />
flavors<br />
50/30 µm divinylbenzene/carboxen/<br />
polydimethylsiloxane on 2 cm StableFlex fiber 23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-0<strong>27</strong>-00<br />
volatile or polar organics in water<br />
75 µm carboxen/polydimethylsiloxane,<br />
65 µm polydimethylsiloxane/divinylbenzene,<br />
65 µm carbowax/divinylbenzene<br />
flavors and odors<br />
100 µm polydimethylsiloxane,<br />
65 µm polydimethylsiloxane/divinylbenzene,<br />
65 µm carboxen/polydimethylsiloxane<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-029-00<br />
23 gauge (OD=0.63 mm)<br />
1 package (3 units) 093639-030-00<br />
40
GERSTEL ® MultiPurpose Sampler, MPS<br />
Part No.<br />
SPME Stableflex fiber kit<br />
23 gauge (OD = 0.63 mm), 4 fibers<br />
50/30 Divinylbenzene/Carboxen<br />
65 µm Polydimethylsiloxane/Divinylbenzene<br />
85 µm Carboxen/Polydimethylsiloxane<br />
70 µm Carbowax/Divinylbenze 093639-031-00<br />
Sample trays<br />
for 200 vials 0.7/1 mL (VT 200) 093631-007-00 *<br />
for 98 vials 2 mL ( VT 98) 093631-008-00 *<br />
for 32 vials 10/20 mL ( VT 32) 093631-009-00 *<br />
for 54 vials 2 mL for stack (VT 54) 093631-010-00 *<br />
for 54 vials 2 mL for stack, 6 units (VT 54) 093631-086-00 *<br />
Adapter plate to use a microtiter or deepwell plate in cooled trays<br />
093631-084-00 *<br />
Plastic tray cover<br />
for 1 mL vials in Tray 093631-068-00 *<br />
for 2 mL vials in Tray 093631-069-00 *<br />
for deepwell or microtiter plates in cooled trays 093631-080-00 *<br />
Inserts for 2 mL vials for agitator<br />
1 package (6 units)<br />
For use with 2 mL vials in combination<br />
with the MPS 2 agitator e.g. for Twister ® Back Extraction.<br />
093631-002-00 *<br />
Delivery times upon request *<br />
41
GERSTEL ® MultiPurpose Sampler, MPS 3<br />
Part No.<br />
MPS 3/3C/3LC are programmable XYZ<br />
autosamplers and sample preparation<br />
robots for liquid chromatography and<br />
LC/MS. The MPS can automate<br />
everything from sample preparation to<br />
sample introduction.<br />
The MPS 3 and MPS 3C are specially<br />
designed for High Throughput Screening,<br />
HTS. The MPS 3LC is a HPLC<br />
autosampler with fixed configuration.<br />
These systems set the standard for speed,<br />
reliability, accuracy and throughput.<br />
GERSTEL MASter Software enables<br />
integrated control of the MPS 3 and a<br />
LC or LC/MS system. One method and<br />
one integrated sequence controls the<br />
complete system through the Agilent ®<br />
Technologies ChemStation Software.<br />
GERSTEL MASter software is fully<br />
integrated into the ChemStation software:<br />
All sample parameters are saved as<br />
part of ChemStation methods. A single<br />
sequence table ties together all sample<br />
information, autosampler functions,<br />
and data file functions. The GERSTEL<br />
PrepBuilder Software enables overlapping<br />
sample preparation and GC analysis.<br />
While LC separation is in progress,<br />
the next sample is being prepared for<br />
analysis, ensuring maximum productivity.<br />
Automated sample preparation<br />
steps include:<br />
• Standard addition<br />
• Derivatization<br />
• Dilution<br />
• Liquid-liquid extraction<br />
• Twister ® Back Extraction<br />
• Membrane Assisted Solvent Extraction<br />
• Heating<br />
• Rinsing<br />
• Agitation<br />
MPS 3LC<br />
MPS 3<br />
42
GERSTEL ® MultiPurpose Sampler, MPS 3<br />
Part No.<br />
Part No.<br />
Vials and caps for use with MPS 3, MPS 3C and MPS 3LC<br />
sampler description volume units Part No.<br />
MPS 3<br />
Crimp cap vials<br />
Crimp cap vial, clear, for 8 mm caps 0.7 mL 100 093640-052-00<br />
Crimp cap vial, clear, for 11 mm caps 2 mL 100 093640-004-00<br />
*<br />
Crimp caps<br />
Crimp cap, Aluminium with septum,<br />
PTFE red / Silicone / PTFE red , for 8 mm vials 0.7 mL 100 093640-053-00<br />
Crimp cap, magnetic, golden with septum,<br />
PTFE red / Silicone / PTFE red, for 11 mm vials 2 mL 100 093640-007-00<br />
Screw cap vials incl. caps and septa<br />
Screw cap vial, clear, incl.<br />
11 mm cap with septum 2 mL 100 089355-076-00<br />
Microliter inserts for 2 mL Screw cap vials<br />
Inert, clear 100 µL 100 093640-029-00<br />
Screw cap vials for Twister ® Back Extraction<br />
for use with 10 mm Twisters<br />
Screw cap vial 32 x 11.6 mm, clear,<br />
for 11 mm screw cap 1.5 mL 100 093640-046-00<br />
Insert 31 x 6 mm, clear, flat bottom 0.2 mL 100 093640-047-00<br />
for use with 20 mm Twisters<br />
Screw cap vial 32 x 11.6 mm, clear,<br />
for 11 mm screw cap 1.1 mL 100 093640-045-00<br />
Screw cap 9 mm with magnetic disks,<br />
blue, with septum, Silicone white / PTFE red,<br />
1.0 mm, 55° shore A 100 093640-048-00<br />
Solvent bottle 100 mL<br />
incl. cap and septum<br />
*<br />
Caps and septa<br />
for 100 mL solvent bottle<br />
093631-054-00<br />
1 package (10 units) 093631-055-00<br />
Wash solvent bottle<br />
for fast wash station<br />
500 mL 093731-018-00 *<br />
1000 mL 093731-115-00<br />
Delivery times upon request *<br />
43
Part No.<br />
Crimper<br />
for 8 mm crimp vials (0.7 mL vials) 093640-054-00 *<br />
for 11 mm crimp vials (2 mL vials) 093640-000-00<br />
Decapper<br />
for 8 mm crimp vials (0.7 mL vials) 093640-055-00<br />
for 11 mm crimp vials (2 mL vials) 093640-002-00<br />
*<br />
Syringe kits<br />
with syringe detect, consisting of: plunger holder,<br />
syringe adapter and 2 syringes<br />
10 µL 093711-007-00<br />
25 µL 093711-008-00<br />
100 µL 093711-009-00<br />
250 µL 093711-010-00<br />
1000 µL 093711-011-00<br />
2500 µL 093711-012-00<br />
5000 µL 093711-013-00<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
Replacement syringe plunger units<br />
10 µL , gastight 10 093611-026-00<br />
25 µL 10 093611-020-00<br />
100 µL 10 093611-021-00<br />
250 µL 10 093611-022-00<br />
500 µL 1 093711-026-00<br />
1000 µL 1 093711-019-00<br />
2500 µL 1 093711-020-00<br />
5000 µL 1 093711-021-00<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
44<br />
Delivery times upon request *
GERSTEL ® MultiPurpose Sampler, MPS 3<br />
Part No.<br />
Part No.<br />
Microliter syringes for MPS 3, MPS 3C and MPS 3LC<br />
The needle types 22 and 22S both have the same outer diameter: 0.72 mm OD and a straight<br />
needle tip (Type LC or 3). Type 22 and 22S differ only by their internal diameter ( 0.41 mm and<br />
0.15 mm ID respectively); Due to the larger ID, a type 22 needle enables faster syringe filling: Up<br />
to 200 µL/sec for type 22 as opposed to 10 – 20 µL/sec for the 22S.<br />
volume (µL) gastight needle gauge point style units Part No.<br />
10 – fixed 22S 3 1 093711-000-00<br />
10 fixed 22S 3 1 093711-014-00<br />
25 fixed 22S 3 1 093711-001-00<br />
100 fixed 22S 3 1 093711-002-00<br />
100 fixed 22 3 1 093711-028-00<br />
250 fixed 22 3 1 093711-003-00<br />
500 fixed 22 3 1 093711-0<strong>27</strong>-00<br />
1000 fixed 22 3 1 093711-004-00<br />
2500 fixed 22 3 1 093711-005-00<br />
5000 fixed 22 3 1 093711-006-00<br />
The long-life Microliter syringes are much more durable than standard syringes.<br />
This is particularly useful for high-pressure work or when a large number of washcycles<br />
are used per sample.<br />
Long-life syringe kits<br />
Each kit contains a syringe holder, a syringe adapter with syringe type detection and two syringes.<br />
volume (µL) gastight needle gauge point style Part No.<br />
25 fixed 22S 3 093711-040-00<br />
100 fixed 22S 3 093711-041-00<br />
Special long life microliter syringes<br />
volume (µL) gastight needle gauge point style units Part No.<br />
25 fixed 22S 3 1 093711-038-00<br />
100 fixed 22S 3 1 093711-039-00<br />
X-type microliter syringes for LC<br />
For use with original CTC syringe adapters. X-type syringes provide extremely low carry-over as well as very<br />
long life-expectancy.<br />
volume (µL) gastight needle gauge point style units Part No.<br />
25 fixed 22S 3 1 093711-042-00<br />
100 fixed 22S 3 1 093711-043-00<br />
100 fixed 22 3 1 093711-044-00<br />
45
Part No.<br />
Dilutor module<br />
for MPS 3, MPS 3C and MPS 3LC<br />
MPS Dilutor syringe<br />
for MPS 3, MPS 3C and MPS 3LC<br />
volume units Part No.<br />
MPS dilutor syringe 1 mL 1 093631-091-00<br />
2.5 mL 1 093631-092-00<br />
5 mL 1 093631-093-00<br />
10 mL 1 093631-094-00<br />
Replacement<br />
syringe plunger 1 mL 1 093632-038-00 *<br />
for MPS 2.5 mL 1 093632-039-00 *<br />
dilutor syringe 5 mL 1 093632-040-00 *<br />
10 mL 1 093632-041-00 *<br />
PTFE ferrule for MPS dilutor syringe 1 093632-045-00 *<br />
Dilutor solvent bottle 1000 mL 1 093632-043-00 *<br />
MPS sideport syringe without needle<br />
For use with MPS sideport-syringe adapter (not<br />
compatible with GERSTEL ® Universal Syringe Adapter)<br />
volume units Part No.<br />
MPS sideport syringe 20 µL 1 093631-096-00<br />
80 µL 1 093631-095-00<br />
Replacement plunger<br />
for sideport syringes 20 µL 10 093611-034-00<br />
80 µL 10 093611-0<strong>27</strong>-00<br />
Replacement needles for MPS sideport syringes<br />
for use with MPS 3 and MPS 3C,<br />
for use with LC injection valves<br />
22 gauge (OD = 0.72mm) needle for 20 µL syringe 3 093711-023-00<br />
22 gauge (OD = 0.72 mm) needle for 80 µL syringe 3 093711-022-00<br />
*<br />
*<br />
46<br />
Delivery times upon request *
GERSTEL ® MultiPurpose Sampler, MPS 3<br />
Part No.<br />
Sample loops<br />
for VICI HPLC-valve 1/16“;<br />
includes nuts and ferrules<br />
1<br />
2<br />
3<br />
2 µL 093731-049-00<br />
20 µL 093731-011-00 *<br />
50 µL 093731-010-00 *<br />
100 µL 093731-009-00 *<br />
500 µL 093731-008-00 *<br />
1000 µL 093731-007-00 *<br />
1<br />
for VICI HPLC-valve,<br />
Typ DC6WK and DC10WK;<br />
includes nuts and ferrules<br />
200 µL 093731-070-00 *<br />
250 µL 093731-055-00 *<br />
MPS 3<br />
2 µL 093731-049-00<br />
5 µL 093731-050-00<br />
10 µL 093731-051-00<br />
15 µL 093731-052-00<br />
25 µL 093731-053-00<br />
30 µL 093731-054-00<br />
2<br />
for Cheminert Injection-valve<br />
20 µL 093731-034-00<br />
50 µL 093731-033-00<br />
100 µL 093731-032-00<br />
250 µL 093731-031-00<br />
500 µL 093731-030-00<br />
3<br />
Sample trays<br />
for 200 x 0.7/1 mL vials (VT 200) 093631-007-00 *<br />
for 98 x 2 mL vials (VT 98) 093631-008-00 *<br />
for 32 x 10/20 mL vials (VT 32) 093631-009-00 *<br />
for 54 x 2 mL vials for stack (VT 54) 093631-010-00 *<br />
for 54 x 2 mL vials for stack, pack with 6 units (VT 54) 093631-086-00 *<br />
Adapter plate to use a microtiter-<br />
or a deepwell plate in cooled trays 093631-084-00<br />
Plastic tray cover<br />
for 1 mL vials tray 093631-068-00 *<br />
for 2 mL vials tray 093631-069-00 *<br />
for deepwell or microtiter plates in cooled trays 093631-080-00 *<br />
Delivery times upon request *<br />
47
GERSTEL ® Twister Desorption Unit, TDU<br />
Part No.<br />
The GERSTEL ® Twister ® Desorption Unit is a<br />
thermal desorption accessory designed for<br />
use with the GERSTEL Twister. The TDU is<br />
based on the same technology as the proven<br />
GERSTEL Thermal Desorption System, TDS, but<br />
is optimized for desorption of Twisters stir bars.<br />
In combination with the GERSTEL MultiPurpose<br />
Sampler, MPS 2, automated analysis of up<br />
to 196 Twisters can be performed in a single<br />
sequence.<br />
Recommended Kit<br />
consists of:<br />
– Glass inserts kit<br />
– O ring kit for transportation adapters (100 units)<br />
– Twister transportation adapters (10 units)<br />
– GRAPHPACK-3D ferrules (10 units)<br />
– Twisters, film thickness 0.5 mm, length 10 mm (10 units)<br />
– GERSTEL-Twister desorption Liner (100 units)<br />
system<br />
Part No.<br />
TDU / CIS 3 01<strong>27</strong>13-003-00<br />
TDU / CIS 4 01<strong>27</strong>13-004-00<br />
48
GERSTEL ® Twister Desorption Unit, TDU<br />
Part No.<br />
Transportation adapter for<br />
GERSTEL ® Twister ® desorption liner<br />
1 package (10 units) 012423-010-00<br />
1 package (100 units) 012423-100-00<br />
Transportation adapter for liquid<br />
injection<br />
1 package (10 units) 013645-010-00<br />
O-ring set for transportation<br />
adapter<br />
1 package (10 Sets) 012424-010-00<br />
1 package (100 Sets) 012424-100-00<br />
Twister desorption liner<br />
1 package (100 units) 013010-100-00<br />
Glass inserts for Twister sample tray<br />
1 package (100 units) 012565-100-00<br />
O-ring for glass inserts<br />
for Twister sample tray<br />
1 package (10 units) 013032-010-00<br />
1 package (100 units) 013032-100-00<br />
49
Part No.<br />
Glass liners for CIS 3/4 in combination with TDU<br />
Part No.<br />
Part No.<br />
packing deactivated description/use units CIS 3/3 S CIS 4<br />
silanized 1 mm ID, straight 10 – 013409-010-00<br />
glass wool<br />
standard glass liner<br />
empty straight with notch 10 013776-010-00 013775-010-00<br />
Initial system checkout; user custom-packed<br />
liners; hot split/splitless injections<br />
empty baffled 10 012441-010-00 012436-010-00<br />
General use liquid injection for<br />
moderate/high boilers, labile compounds,<br />
split injections<br />
empty 2 mm ID 10 – 013911-010-00<br />
For special applications<br />
silanized General use liquid injection for 10 01<strong>27</strong>41-010-00 01<strong>27</strong>42-010-00<br />
glass wool<br />
moderate/high boilers, stable compounds;<br />
glass wool<br />
thermal desorption cryotrapping<br />
of stable compounds<br />
quartz wool More inert than glass wool; used for trapping 10 012442-010-00 012437-010-00<br />
labile compounds<br />
Tenax TA Elimination of water (40°C most effective); 10 012443-010-00 012438-010-00<br />
Trapping of C 5 and higher volatiles<br />
(-50°C minimum temperature)<br />
Carbotrap B Trapping of low boiling volatiles 10 012444-010-00 012439-010-00<br />
Glass liner kit CIS/TDU<br />
Part No.<br />
Part No.<br />
included glass liners units (each) units (each) CIS 3 CIS 4<br />
CIS 3 CIS 4<br />
empty (baffled) 2 2 012440-003-00 012440-004-00<br />
packed with silanized glass wool 4 2<br />
packed with Tenax TA 2 2<br />
packed with Carbopack B 2 2<br />
1 mm ID, packed with<br />
silanized glass wool – 2<br />
Note<br />
The CIS glass liners listed in the above tables are designed for use only in combination with<br />
a TDU. For all other analyses using a CIS use only the inlet liners listed on page 24.<br />
50
GERSTEL ® Twister Desorption Unit, TDU<br />
Part No.<br />
GRAPHPACK ® 3D ferrules for glass liners<br />
1 package (5/10 units)<br />
Part No.<br />
Part No.<br />
units CIS 3 CIS 4/CIS 6 *<br />
5 002426-005-00 007541-005-00<br />
10 002426-010-00 007541-010-00<br />
Mica coated for improved sealing<br />
Part No.<br />
Part No.<br />
units CIS 3 CIS 4/CIS 6 *<br />
5 002426-105-00 -<br />
10 002426-110-00 -<br />
GRAPHPACK 3D mounting<br />
tool for glass liners<br />
Note<br />
The GRAPHPACK 3D mounting tool is<br />
designed for use only with glass liners used<br />
in combination with a TDU. (see page 50)<br />
TDU/CIS 3 01<strong>27</strong>81-003-00<br />
TDU/CIS 4 01<strong>27</strong>81-004-00<br />
Septum for transportation<br />
adapter for liquid injection<br />
1 package (100 units) 014052-100-00<br />
Allen wrench for transportation<br />
adapter screws, 5 mm<br />
009999-205-00<br />
51
Part No.<br />
GERSTEL Twister ®<br />
The GERSTEL ® Twister ® looks just like a conventional<br />
magnetic stir bar, except for the polydimethylsiloxane<br />
(PDMS) coating. While stirring the aqueous or polar<br />
liquid sample, the Twister efficiently extracts organic<br />
compounds into the PDMS phase. After stirring, the<br />
Twister is transferred to a GERSTEL Thermal Desorption<br />
System. Thermal desorption ensures efficient and<br />
quantitative transfer of analytes to the GC column and<br />
lowest detection limits. Thermally labile analytes can<br />
be desorbed using a liquid solvent for subsequent LC<br />
determination – or for Large Volume Injection GC. Due<br />
to the large volume of PDMS on the Twister and due to<br />
the stirring effiency, it provides much greater capacity<br />
and much lower detection limits than SPME.<br />
Part No.<br />
Book »New Concepts in Sorption Based<br />
Sample Preparation for Chromatography«<br />
by H.A. Baltussen, 241 pages<br />
013745-000-00<br />
GERSTEL Twister ®<br />
for Stir Bar Sorptive Extraction (SBSE)<br />
with polydimethylsiloxane phase (PDMS)<br />
film thickness 0.5 mm,<br />
length 10 mm<br />
10 units 011222-001-00<br />
100 units 011222-002-00<br />
film thickness 1 mm,<br />
length 10 mm<br />
10 units 011333-001-00<br />
100 units 011333-002-00<br />
film thickness 0.5 mm,<br />
length 20 mm<br />
10 units 011444-001-00<br />
100 units 011444-002-00<br />
film thickness 1 mm,<br />
length 20 mm<br />
10 units 011555-001-00<br />
100 units 011555-002-00<br />
52
GERSTEL ® Twister ® 53<br />
Part No.<br />
GERSTEL ® Twister ® kit<br />
Set of Twisters for Stir Bar Sorptive Extraction (SBSE) with<br />
polydimenthylsiloxane (PDMS) phase.<br />
film thickness 0.5 mm, 10 mm length (4 units)<br />
film thickness 1.0 mm, 10 mm length (2 units)<br />
film thickness 0.5 mm, 20 mm length (2 units)<br />
film thickness 1.0 mm, 20 mm length (2 units)<br />
012370-000-00<br />
Desorption tubes for use with TDS,<br />
TDS A2 or Tube Conditioner, TC 1/2<br />
for Twisters with film thickness up to 1 mm,<br />
tube 6 mm OD, 4.5 mm ID, 1 package (10 units)<br />
012518-010-00<br />
Forceps<br />
009999-025-00<br />
Vials<br />
1<br />
2 mL vial<br />
with screw cap and septum,<br />
1 package (100 units) 089355-076-00<br />
1<br />
3<br />
2<br />
3<br />
10 mL vial<br />
1 package (100 units) 093640-005-00<br />
20 mL vial<br />
1 package (100 units) 093640-006-00<br />
2
Part No.<br />
Twister ® Headspace Sorptive Extraction (HSSE),<br />
analyte extraction and concentration from the vapor<br />
phase using the GERSTEL ® Twister.<br />
HSSE is a concentration technique that is much more<br />
sensitive than traditional static headspace analysis.<br />
A Twister is placed in an open adapter inside a closed<br />
headspace vial. The Twister is placed in the vapor<br />
phase above the sample such that analytes are<br />
extracted by, and concentrated into, the PDMS phase<br />
of the Twister. Sorptive extraction and concentration<br />
of organic compounds provides lower detection limits<br />
when combined with a GERSTEL TDS or TDU system<br />
for thermal desorption GC or GC/MS analysis.<br />
TWISTER headspace vials 20 mL<br />
1 package (100 units)<br />
012491-000-00<br />
Inserts for 20 mL Twister headspace vials 20 mL<br />
1 package (100 units)<br />
012492-000-00<br />
Crimp caps<br />
for 10/20 mL vial (100 units)<br />
089280-009-00 *<br />
Septa<br />
for 10/20 mL vial (100 units)<br />
089280-010-00<br />
*<br />
54<br />
Delivery times upon request *
GERSTEL ® Twister ® 55<br />
Part No.<br />
Twister ® Back Extraction Option<br />
for the MPS 3<br />
consists of:<br />
– 1.5 mL vials with caps and 200 µL inserts (100 units<br />
– Opening lock for the Agitator (1 unit)<br />
– Twister Back Extraction sequence software (1 unit)<br />
Requires, but does not include, GERSTEL ® MPS 3<br />
with GERSTEL MASter software.<br />
012195-099-00<br />
Crimper<br />
for 20 mm crimp caps (10/20 mL vials)<br />
093640-001-00<br />
Decapper<br />
for 20 mm crimp caps (10/20 mL vials)<br />
093640-003-00<br />
Mechanical crimper<br />
for 20 mm crimp caps<br />
Spare parts<br />
see page 35<br />
093640-009-00
GERSTEL ® Thermal Desorption System, TDS<br />
Part No.<br />
The GERSTEL ® Thermal Desorption System,<br />
TDS 3 is a highly optimized system for<br />
thermal desorption of Volatile Organic<br />
Compounds (VOCs) and Semi-Volatile<br />
Organic Compounds (SVOCs) followed by<br />
cryofocusing and GC analysis.<br />
Thermal desorption is a powerful concentration<br />
technique providing extremely<br />
low limits of detection. VOCs and SVOCs<br />
from gas-phase samples are trapped and<br />
concentrated on an adsorbent bed in a TDS<br />
tube by pumping a volume of the gas-phase<br />
sample through the tube. Solid and liquid<br />
samples can be placed in the TDS tube<br />
for direct thermal extraction or dynamic<br />
headspace of VOCs and SVOCs.<br />
In the TDS 3, analytes are thermally<br />
desorbed from the TDS tube using<br />
heat and a controlled flow of inert gas.<br />
Following primary desorption, analytes are<br />
concentrated on a second and smaller trap<br />
prior to GC or GC/MS determination.<br />
The GERSTEL Cooled Injection System,<br />
CIS functions as a cryotrap for the TDS 3,<br />
focusing and concentrating the compounds<br />
to be determined, and then transferring<br />
them to the capillary column in a narrow<br />
band for optimal GC separation using rapid,<br />
programmed heating.<br />
With the addition of the TDS A the TDS 3<br />
becomes a fully automated thermal<br />
desorption system capable of unattended,<br />
automated analysis of up to 20 samples. A<br />
separate TDS system, the TDS G on-line, is<br />
designed for continuous on-line analysis of<br />
VOCs and SVOCs in air and gas streams.<br />
TDS A2<br />
TDS 3<br />
TDS G<br />
56
GERSTEL ® TDS family<br />
Part No.<br />
TDS tube adapter for<br />
GERSTEL ® TDS 3<br />
Allows 1/4” OD x 3.5“ L<br />
desorption tubes to be used with the<br />
TDS 3 (stainless steel tubes only)<br />
Vespel cone<br />
Vespel cone for TDS Tube adapter<br />
1 unit 014454-000-00<br />
1 set (21 units) 014454-021-00<br />
1 package (5 units) 014456-005-00<br />
Screw driver SW 1.5<br />
for TDS tube adapter<br />
013329-000-00<br />
Spare parts for TDS 2/3 septum<br />
head for liquid injection<br />
Special needle<br />
for 10 µl syringe, length 115 mm<br />
1 package (5 units) 009970-059-00<br />
Ice blue septa<br />
5 mm<br />
1 package (100 units) 014052-100-00<br />
SLH adapter<br />
for spiking TDS tubes<br />
CIS 3 008871-003-00<br />
CIS 4/6 008871-003-00<br />
Special needle<br />
for 10 µl syringe, length 81 mm<br />
009970-016-00<br />
1 package (2 units) 009970-049-00<br />
Supply kit for TDS 2/3<br />
calibration adapter<br />
includes 5 glass tubes with<br />
GP 3D ferrules and 5 teflon ferrules<br />
SLH / CIS 3 010454-003-00<br />
SLH / CIS 4 010454-004-00<br />
57
Part No.<br />
1<br />
Desorption tubes<br />
6 mm OD, for use with all GERSTEL TDS systems.<br />
Each tube has a unique serial number for identification and traceability.<br />
2<br />
4<br />
3<br />
5<br />
packing conditioned description units Part No.<br />
1<br />
2<br />
Tenax TA 60/80<br />
Tenax GR<br />
–<br />
–<br />
glass tube<br />
glass tube<br />
5<br />
5<br />
012260-005-00<br />
012<strong>27</strong>5-005-00<br />
3 Chromosorb 106 – glass tube 5 012<strong>27</strong>6-005-00<br />
4 Carbosieve – glass tube 5 012<strong>27</strong>7-005-00<br />
Carbotrap 300 – multibed, glass tube 5 012346-005-00<br />
Carbotrap 300 – multibed, glass tube 1 012347-005-00<br />
Tenax TA 60/80 – 1<br />
Tenax GR – 1<br />
Chromosorb 106 – 1<br />
Carbosieve – 1<br />
Carbotrap B 100 mg 1 012458-000-00<br />
Carbotrap C 200 mg<br />
Tenax TA 60/80 in storage container, glass tube 1 009947-000-00<br />
Tenax TA 60/80 in storage container, SS tube 1 010040-000-00<br />
Tenax GR in storage container, glass tube 1 009948-000-00<br />
Tenax GR in storage container, SS tube 1 010041-000-00<br />
Carbosieve in storage container, glass tube 1 009949-000-00<br />
Carbosieve in storage container, SS tube 1 010042-000-00<br />
Carbotrap 300 in storage container, glass tube 1 008357-000-00<br />
Carbotrap 300 in storage container, SS tube 1 010044-000-00<br />
Carbotrap 349 in storage container, glass tube 1 009117-000-00<br />
Carbotrap 217 in storage container, glass tube 1 013115-000-00<br />
5 Tenax / Carboxene – in storage container, glass tube 1 009118-000-00<br />
empty – glass tube 10 010649-010-00<br />
6 empty – glass tube 1 010649-000-00<br />
7 empty – glass tube with glass frit 1 010650-000-00<br />
empty – glass tube with glass frit 10 010650-010-00<br />
6<br />
7<br />
58
GERSTEL ® TDS family<br />
Part No.<br />
GERSTEL ® TDS adsorbent overview<br />
Graphitized Carbon Blacks<br />
Carbotrap/Carbopack Unlike activated charcoals, which<br />
are porous, graphitized carbon blacks (GCBs), such as<br />
Carbotrap and Carbopack, are generally non-porous.<br />
Consequently, the entire surface of these materials is<br />
available for interactions that depend solely on dispersion<br />
(London) forces. These adsorbents offer excellent thermal<br />
stability, which ensures minimal bleed at thermal desorption<br />
temperatures, and their coarse 20/40 and 40/60 mesh particle<br />
size prevents high pressure drop across the tube. Hydrophobic<br />
properties minimize sample displacement by water, enabling<br />
you to obtain accurate samples despite high humidity. Trapped<br />
compounds can be desorbed by solvent or thermal desorption<br />
at virtually 100% desorption efficiency.<br />
Carbopack B is essentially the same adsorbent as Carbotrap;<br />
the only difference is the mesh size (60/80 mesh for Carbopack B<br />
vs. 20/40 mesh for Carbotrap). Both have a specific surface area<br />
of 100 m 2 /g. Carbopack B is often used in narrow bore tubes (1-2<br />
mm ID), for sample refocusing or for very low flow sampling (e.g.,<br />
Part No.<br />
Sorption tubes<br />
1<br />
packing conditioned description units Part No.<br />
PDMS – 1<br />
6 mm OD, glass tube, 1 009171-000-00<br />
for gaseous samples<br />
2<br />
<strong>Supplies</strong> for desorption tubes<br />
OD description units Part No.<br />
3<br />
Storage Container 6 mm 2<br />
single 1 008351-000-00<br />
End cap set 6 mm 3<br />
stainless steel, with PTFE seals 1 008235-060-00<br />
End caps 6 mm stainless steel, with PTFE seals 10 012659-010-00<br />
Storage end caps 1/4 “ 3.5 “ long, brass 20 011754-020-00<br />
TDS empty tubes 1/4 “ 3.5 “ long, stainless steel 1 011619-000-00<br />
Diffusion caps 1/4 “ 3.5 “ long, stainless steel 10 011620-010-00<br />
for TDS tubes<br />
Screens 4<br />
10 008980-010-00<br />
4<br />
Tweezer for handling TDS tubes<br />
009970-050-00<br />
O-rings for TDS A<br />
sample magazine<br />
1 package (10 units)<br />
008174-010-00<br />
Sealing plugs for TDS A/A2<br />
sample magazine<br />
1 package (10 units)<br />
014173-010-00<br />
60
GERSTEL ® TDS family<br />
Part No.<br />
Spare parts for TDS 2/3<br />
locking cone<br />
O-ring set<br />
for TDS 2/3 locking cone manual<br />
007884-000-00<br />
Inner O-ring<br />
for TDS 2/3-TDS A/A2 locking cone,<br />
1 package (5 units)<br />
009095-005-00<br />
Fixing nut for inner O-ring<br />
for TDS 2/3 locking cone<br />
009013-001-00<br />
Spare parts for TDS A/A2 locking cone<br />
1<br />
1<br />
Service kit for TDS A/A2 locking cone 010441-000-00<br />
2<br />
3<br />
Fixing nut for inner O-ring<br />
for TDS A locking cone 009013-000-00<br />
Inner O-ring for TDS 2/3/TDS A/A2 locking cone<br />
1 package (5 units) 009095-005-00<br />
2<br />
3<br />
4<br />
Spindel O-ring<br />
1 package (5 units) 010372-005-00<br />
5<br />
Spindel safety catch<br />
1 package (5 units) 011061-005-00<br />
4<br />
5<br />
61
Part No.<br />
Direct interface<br />
for 0.7 mm OD transfer line<br />
System for transfer line OD units<br />
TDS 2/3 with CIS 3 0.70 mm 1 007823-007-00<br />
TDS 2/3 with CIS 4 0.70 mm 1 008311-007-00<br />
TDS 2/3 – TDS G with CIS 3s 0.70 mm 1 011025-007-00<br />
TDS 2/3 with CIS 3s Tremetics 0.70 mm 1 011628-007-00<br />
Transfer lines<br />
for TDS 2/3 with CIS 3/CIS 4, length 5 m<br />
Version deactivated OD/ID<br />
ProSteel ® 0.67 mm/0.53 mm 008687-005-00<br />
Silcosteel ® 0.74 mm/0.45 mm 010963-005-00<br />
Sulfinert ® 0.74 mm/0.45 mm 012185-005-00<br />
Transfer line kit<br />
for TDS 2/3 with CIS 3/CIS 4, length 1 m<br />
Version deactivated OD units<br />
ProSteel ® 0.67 mm 1<br />
GRAPHPACK ® 2M ferrule 10 011004-000-00<br />
Silcosteel ® 0.74 mm 1<br />
GRAPHPACK 2M ferrule 10 011005-000-00<br />
Sulfinert 0.74 mm 1<br />
GRAPHPACK 2M ferrule 10 012186-000-00<br />
Direct interface<br />
for 0.45 mm OD transfer line<br />
System OD units<br />
TDS 2/3 with CIS 3 0.45 mm 1 007823-045-00<br />
TDS 2/3 with CIS 4 0.45 mm 1 008311-045-00<br />
TDS 2/3 – TDS G with CIS 3s 0.45 mm 1 011025-045-00<br />
TDS 2/3 with CIS 3s Tremetics 0.45 mm 1 011628-045-00<br />
Transfer line<br />
for TDS 2/3 with CIS 3/CIS 4, length 5 m<br />
Version deactivated OD<br />
Fused Silica 0.45 mm 005014-005-00<br />
Transfer line kit<br />
for TDS 2/3 with CIS 3/CIS 4, length 1 m<br />
Version deactivated OD units<br />
Fused Silica 0.45 mm 1<br />
GRAPHPACK 2M ferrule 10 011003-000-00<br />
62
GERSTEL ® TDS family<br />
Part No.<br />
GRAPHPACK ® 2M adapter<br />
for TDS 2/3, for 0.45 mm OD transfer line 007820-045-00<br />
for TDS 2/3 and TDS G, for 0.7 mm OD transfer line 007820-007-00<br />
Silver seal<br />
for GRAPHPACK 2M adapter<br />
for TDS 2/3 and TDS G<br />
1 package (5 units) 007821-005-00<br />
Spare parts for TDS G<br />
GRAPHPACK Micro screw<br />
single, 0.70 mm<br />
007910-007-00<br />
GRAPHPACK Micro ferrule<br />
0.70 mm; 1 package (10 units)<br />
001905-007-00<br />
Adapter for GRAPHPACK Micro screw<br />
in conjunction with Valco Vici valve 1/16”<br />
008688-007-00<br />
GRAPHPACK 2M injector adapter<br />
for Valco Vici valve, 1/16"<br />
008019-045-00<br />
63
GERSTEL ® Pyrolysis Module, PM 1<br />
Part No.<br />
Manual Pyrolysis module for the TDS.<br />
Part No.<br />
Sample tubes<br />
for GERSTEL ® Pyrolysis Module PM1<br />
1 package (10 units) 009250-010-00<br />
1 package (50 units) 009250-050-00<br />
64
GERSTEL ® Pyrolysis module, PM 1<br />
Part No.<br />
Pyrolysis TDS tube<br />
for GERSTEL ® Pyrolysis Module,<br />
6.0 mm OD; 5.0 mm ID<br />
Note<br />
for use with Pyrolysis<br />
Module only<br />
Quartz glass<br />
1 units 009553-100-00<br />
Borosilicate glass<br />
10 units 009553-010-00<br />
Spare parts<br />
O-ring set for TDS 2/3<br />
manual locking cone<br />
007884-000-00<br />
Inner O-ring for<br />
TDS 2/3 locking cone<br />
1 package (5 units)<br />
009095-005-00<br />
Fixing nut for inner O-ring<br />
for TDS A/A2 locking cone<br />
009013-000-00<br />
65
Part No.<br />
GERSTEL ®<br />
Thermal Extractor, TE 1/2<br />
The GERSTEL Thermal Extractor TE 2 enables the analyst<br />
to extract volatile and semi-volatile organic compounds<br />
from liquid or solid samples, trapping the compounds on<br />
a TDS tube for further analysis. For aldehyde analysis,<br />
analytes can be trapped on a DNPH tube for subsequent<br />
liquid elution and LC analysis. The GERSTEL TE 2 has a<br />
larger inner diameter than normal TDS tubes. Larger sample<br />
volumes can be analyzed to obtain lower detection limits.<br />
A larger, more representative sample volume also ensures<br />
better results when analyzing inhomogenous samples.<br />
The GERSTEL TE 2 is completely independent of the TDS<br />
system, eliminating the risk of system contamination when<br />
analyzing unknown samples.<br />
Part No.<br />
O-ring set for tube holder<br />
complete set of inner and outer O-rings<br />
008634-000-00<br />
Inner O-ring for tube holder<br />
1 package (5 units) 009411-005-00<br />
66
GERSTEL ® Thermal Extractor, TE 1<br />
Part No.<br />
Empty tubes for GERSTEL ® TE<br />
1 package (5 units) 008589-005-00<br />
Inner O-ring for TE tube holder<br />
Kalrez (1 units) 008766-000-00<br />
PTFE ferrule for TDS<br />
desorption tube<br />
1 package (5 units) 00<strong>27</strong>32-005-00<br />
Desorption tubes for TDS 2/3<br />
and TDS A/A2<br />
see pages 58 – 60<br />
Screens for TE tube<br />
1 package (10 units) 008590-010-00<br />
67
GERSTEL ® Tube Conditioner, TC 1/2<br />
Part No.<br />
For simultaneous conditioning of up to ten TDS tubes or up to<br />
50 Twister ® s (5 Twisters per TDS tube). Tube conditioning is<br />
performed under a flow of inert gas at elevated temperatures. The<br />
gas flow to each tube is independently controlled allowing full loading<br />
flexibility. The GERSTEL TC 2 operates independently of the analytical<br />
system, eliminating the risk of system contamination and ensuring<br />
maximum productivity.<br />
68
GERSTEL ® Tube Conditioner, TC 1/2<br />
Part No.<br />
O-ring set for TC 1/2 tube holder<br />
1 package (1 sets) 009650-000-00<br />
TDS desorption tubes<br />
for 1 mm film thickness Twisters;<br />
tube 6 mm OD x 4.5 mm ID<br />
1 package (10 units) 012518-010-00<br />
69
Part No.<br />
GERSTEL ®<br />
Column Switching Systems, MCS<br />
The GERSTEL MultiColumn Switching System, MCS enables<br />
the combination of different capillary columns in one system for<br />
improved separation of complex samples. The system enables<br />
venting of solvent and low-boiling compounds, improved overall<br />
separation, targeted separation of a particular section of a<br />
chromatogram on a separate column, and accurate effluent<br />
splitting between detectors such as MSD, FID, FPD and the<br />
GERSTEL Olfactory Detection Port, ODP.<br />
! Important note<br />
Column switching devices are<br />
available only for customers with a<br />
GERSTEL column switching system.<br />
Part No.<br />
GRAPHPACK ® 3D/2 column<br />
switching device for MCS 2,<br />
Sulfinert ®<br />
pre-column OD (mm) – main column OD (mm)<br />
0.45 – 0.45 011645-045-00<br />
GRAPHPACK 3D/2 mounting tool<br />
kit for column switching device<br />
For the rapid creation of low-dead-volume<br />
connections when using GRAPHPACK<br />
3D/2 column switching device. Suitable for<br />
all capillary columns with outside diameters<br />
between 0.2 mm and 0.8 mm.<br />
complete kit 006758-000-00<br />
GRAPHPACK mounting tool<br />
tool body without insert<br />
003424-000-00<br />
70<br />
For GRAPHPACK 3D/2 ferrules and<br />
GRAPHPACK 2M ferrules see GRAPHPACK<br />
section beginning with page 16.
GERSTEL ® Multi Column Switching Systems, MCS<br />
Part No.<br />
Part No.<br />
Insert for 1.5 mm<br />
column mounting depth<br />
Color: gold 008994-004-00<br />
Insert holder<br />
Column OD<br />
0.20 mm to 0.31 mm 008995-031-00<br />
0.40 mm to 0.45 mm 008995-045-00<br />
0.70 mm to 0.80 mm 008995-008-00<br />
GRAPHPACK ® 3D/2 ferrule kit<br />
for MCS 2<br />
007361-000-00<br />
Fixing nut for column<br />
switching device<br />
006530-000-00<br />
Restriction capillary<br />
deactivated column OD / column ID / length units<br />
0.40 mm / 0.05 mm / 0.4 m 5 007304-000-00<br />
0.40 mm / 0.05 mm / 5 m 1 007304-005-00<br />
0.40 mm / 0.05 mm / 10 m 1 007304-010-00<br />
71
GERSTEL ® Preparative Fraction Collector, PFC<br />
Part No.<br />
The GERSTEL PFC is used for purification and<br />
collection of compounds or compound classes<br />
following separation by capillary gas chromatography.<br />
Compounds are automatically and selectively collected<br />
in up to six different traps that can be heated or cooled<br />
depending on the needs for the type of compounds.<br />
Highly accurate switching between the traps enable the<br />
analyst to collect and accumulate compounds with high<br />
purity and high yield from up to 150 GC runs. A seventh<br />
trap is available to collect all compounds not collected<br />
in the main traps. These compounds can be saved for<br />
further analysis or for conducting “subtraction studies” of<br />
key compounds.<br />
72
GERSTEL ® Preparative Fraction Collector, PFC<br />
Part No.<br />
GRAPHPACK ® 3D/2 mounting<br />
tool kit for switching device<br />
For the rapid creation of low-dead-volume<br />
connections when using the PFC switching<br />
device. Suitable for all capillary columns with<br />
outside diameters 0.45 mm.<br />
complete kit 006752-000-00<br />
Spare parts<br />
GRAPHPACK mounting tool<br />
single, without insert 003424-000-00<br />
Insert for 3.0 mm mounting<br />
depth<br />
Color: silver<br />
008994-005-00<br />
Insert holder<br />
Column OD<br />
0.45 mm 008995-045-00<br />
GRAPHPACK 3D/2<br />
sealing ferrule<br />
1 package (5 units)<br />
Column OD (mm)<br />
0.31 006520-031-00<br />
0.40 006520-040-00<br />
0.45 006520-045-00<br />
0.70 006520-007-00<br />
73
Part No.<br />
GRAPHPACK ® 3D/2 ferrule<br />
kit for PFC<br />
006761-000-00<br />
GRAPHPACK 3D/2 switching<br />
device for PFC, Sulfinert ®<br />
complete<br />
! Important note<br />
Switching devices are available only<br />
for customers with a GERSTEL ®<br />
Preparative Fraction Collector.<br />
012218-045-00<br />
GRAPHPACK 3D/2 effluent<br />
splitter for FID, Sulfinert ®<br />
for HP 5890 II, Agilent 6890<br />
column OD 0.70 mm 012219-007-00<br />
Replacement<br />
Fixing nut 006530-000-00<br />
Restriction capillary<br />
deactivated,<br />
0.40 mm OD, 0.05 mm ID<br />
length<br />
80 mm (5 units) 007304-001-00<br />
5 m (1 unit) 007304-005-00<br />
10 m (1 unit) 007304-010-00<br />
Silicone tubing for PFC<br />
for connecting component traps to solenoid<br />
valve<br />
length<br />
10 m 007593-000-00<br />
74
GERSTEL ® Preparative Fraction Collector, PFC<br />
Part No.<br />
Trap adapter<br />
for traps 1 µL – 100 µL<br />
1 unit 011229-000-00<br />
Sample traps<br />
1<br />
1 µL<br />
1 package (10 units) 005507-010-00<br />
1 package (50 units) 005507-050-00<br />
1<br />
2<br />
100 µL<br />
1 package (10 units) 005509-010-00<br />
1 package (50 units) 005509-050-00<br />
2<br />
Teflon ferrules<br />
for sample traps<br />
ID 3.0 mm; for traps<br />
1 µL and 100 µL<br />
1 package (10 units) 005002-010-00<br />
Sample traps, coiled<br />
1 µL<br />
1 package (10 units) 006633-010-00<br />
Teflon ferrules<br />
for sample traps<br />
1 package (10 units)<br />
ID 1.8 mm<br />
for 1 µL, coiled traps 005002-028-00<br />
Transfer capillary<br />
for connecting FID effluent splitter to PFC<br />
switching device, deactivated<br />
OD 0.45 mm<br />
L = 870 mm<br />
1 package (5 units) 005010-000-00<br />
Capillary for sample trap<br />
for connecting switching device to<br />
component traps, deactivated<br />
OD 0.45 mm<br />
180 mm (5 units) 005014-000-00<br />
5 m (1 unit) 005014-005-00<br />
10 m (1 unit) 005014-010-00<br />
75
Part No.<br />
GERSTEL ®<br />
Olfactory Detector Port, ODP 2<br />
The GERSTEL ODP allows olfactory detection of compounds by<br />
the human nose. Olfactory detection is performed in parallel to<br />
GC detection with FID, FPD or MSD detectors as compounds<br />
elute from the GC column. The effluent is split as it leaves the<br />
column, arriving simultaneously at the nose and at the detector,<br />
enabling the analyst to gain additional information on odor-active<br />
compounds. Using a headset with a microphone coupled<br />
to voice recognition software, the analyst can insert spoken<br />
comments directly into the chromatogram for peak annotation<br />
and into the analysis report.<br />
Part No.<br />
1<br />
Nose cones<br />
2<br />
1<br />
2<br />
for use with ODP 1/2 with humidifier 006285-000-00<br />
for use with ODP 1/2 without humidifier 008012-000-00<br />
GRAPHPACK ® 3D/2 column<br />
connector with 1/16”<br />
gas connection, Sulfinert ®<br />
Column OD<br />
from 0.80 mm OD to<br />
0.45 mm 013508-045-00<br />
Silicone tubing for connecting<br />
nose cone and humifidier vial<br />
length<br />
2 m 008647-000-00<br />
76
GERSTEL ® Olfactory Detection Port, ODP 2<br />
Part No.<br />
Part No.<br />
Humidifier vial<br />
008204-000-00<br />
GRAPHPACK ® 3D/2<br />
crosspiece kit, Sulfinert ®<br />
for Agilent GC detectors, allows<br />
simultaneous detection at the nose<br />
and the GC detectors.<br />
Includes: GRAPHPACK adapter for<br />
MSD and FID or TCD<br />
main column OD<br />
splitter/restrictor capillary OD<br />
0.31 mm 0.40 mm 013493-031-00<br />
0.45 mm 0.40 mm 013493-045-00<br />
0.70 mm 0.40 mm 013493-007-00<br />
2<br />
GRAPHPACK 3D/2<br />
crosspiece, Sulfinert ®<br />
1<br />
main column OD<br />
2<br />
splitter/restrictor capillary OD<br />
2<br />
2<br />
0.31 mm 0.40 mm 012240-031-00<br />
0.45 mm 0.40 mm 012240-045-00<br />
0.70 mm 0.40 mm 012240-007-00<br />
1<br />
GRAPHPACK 2M detector adapter<br />
MSD HP 5971/5972 GCD Series G 1800 A 006511-040-00<br />
HP 5890 A and Series II and Agilent 6850/6890 006508-040-00<br />
Spare parts<br />
GRAPHPACK nut<br />
for all GRAPHPACK adapters;<br />
1 package (5 units) 001268-005-00<br />
Splitter/restrictor<br />
capillaries<br />
OD/ID length units<br />
0.36 mm / 0.10 mm 1 m 1 006558-001-00<br />
0.36 mm / 0.10 mm 5 m 1 006558-005-00<br />
10 m 1 006558-010-00<br />
0.35 mm / 0.20 mm 10 m 1 009995-003-00<br />
0.36 mm / 0.15 mm 2 m 1 005344-002-00<br />
0.36 mm / 0.15 mm 5 m 1 005344-005-00<br />
77
GERSTEL ® ChemSensor Systems<br />
Part No.<br />
For classification of compound groups or sample groups based<br />
on chemometric analysis with or without chromatography<br />
separation. Three-dimensional data (intensity, mass fragment<br />
and retention time) obtained with a mass selective detector<br />
MSD is reduced to two dimensions, enabling fast and reliable<br />
classification of samples. Introduction techniques used are<br />
Headspace and SPME.<br />
Part No.<br />
MSD spare parts<br />
CI Filament<br />
for the Agilent 5973/5975 MSD;<br />
1 package (2 units)<br />
089345-092-00 *<br />
78<br />
Delivery times upon request *
GERSTEL ® ChemSensor Systems<br />
Part No.<br />
GERSTEL ® ChemSensor<br />
interface spare parts<br />
Transfer capillary<br />
ID = 0.1 mm, OD = 0.36 mm, l = 1 m 006558-001-00<br />
GRAPHPACK ® 2M ferrule<br />
for column OD 0.4 mm;<br />
1 package (10 units) 001805-040-00<br />
GRAPHPACK 2M blind plug<br />
1 package (10 units) 001805-000-00<br />
GRAPHPACK nut<br />
1 package (5 units) 001268-005-00<br />
Direct interface<br />
for ChemSensor CIS 4 Plus 012301-040-00<br />
Silver seal<br />
for direct interface;<br />
1 package (5 units) 002841-005-00<br />
GRAPHPACK 2M MSD adapter<br />
for Hewlett-Packard or<br />
Agilent Technologies 5971/5972/5973/5973 N/5973 Inert/5975 MSD,<br />
for column OD 0.4 mm 006511-040-00<br />
Silver seal<br />
for GRAPHPACK 2M MSD adapter 1 package (5 units) 005249-005-00<br />
Vials and crimp caps for the<br />
ChemSensor 4440<br />
10 mL Crimp cap vial<br />
clear, with flat bottom for 20 mm caps for<br />
use with the Agilent Technologies 7694<br />
Headspace Autosampler<br />
Crimp caps<br />
Aluminum crimp caps with safety closure,<br />
Silicone / PTFE septum, for 20 mm vials<br />
1 package (100 units) 011912-000-00<br />
1 package (5 units) 011912-002-00<br />
79
GERSTEL ® approved supplies<br />
Part No.<br />
Beside our own supplies for GERSTEL systems we offer a wide<br />
range of supplies from other manufacturers. These products<br />
have been tested by us and have our approval for ensuring<br />
proper operation with GERSTEL systems.<br />
Part No.<br />
SS capillary<br />
1/8", 1 m 003701-000-00<br />
Cu tubing<br />
1/8", 1 m 003702-000-00<br />
Swagelok SS adapter<br />
complete with nuts and ferrules<br />
1 unit<br />
1/16" SW, complete 004921-000-00<br />
1/8" SW, complete 004922-000-00<br />
1/4" SW, complete 004923-000-00<br />
1/16" to 2 mm 005207-000-00<br />
Swagelok set<br />
consisting of nut, ferrule, and back ferrule<br />
1 unit<br />
1/4" SS 007887-004-00<br />
1/8" SS 007887-008-00<br />
1/16" SS 007887-016-00<br />
1 package (10 units)<br />
1/4" MS 013343-004-00<br />
1/8" MS 013343-008-00<br />
1/16" MS 013343-016-00<br />
Tube adapter for VICI actuator<br />
1 package (2 units) 010906-002-00<br />
80
GERSTEL ® approved supplies<br />
Part No.<br />
Tools<br />
Set of mandrels 1 package (5 units) 009999-073-00<br />
Magnifying glass (plastic) 10x 009999-079-00<br />
Diamond file 009999-080-00<br />
Open end wrenches<br />
complete set; 6 units, sw 4 – 8 009999-081-00<br />
SW 8 009999-082-00<br />
SW 7 009999-083-00<br />
SW 6 009999-084-00<br />
SW 5.5 009999-085-00<br />
SW 5 009999-086-00<br />
SW 4 009999-087-00<br />
81
Part No.<br />
Reducing ferrules<br />
1 package (5 units)<br />
Vespel reducing ferrule<br />
1/4" – 6 mm 009999-074-00<br />
1/4" – 1/8" 009999-088-00<br />
1/4" – 1/16" 009999-089-00<br />
1/8" – 1/16" 009999-090-00<br />
Graphite ferrule<br />
40% graphite, 1/4" 009999-091-00<br />
40% graphite. 1/8" 009999-092-00<br />
40% graphite, 1/16" 009999-093-00<br />
1/4" 009999-094-00<br />
1/8" 009999-095-00<br />
1/16" 009999-096-00<br />
Vespel graphite ferrule<br />
1/4" 009999-097-00<br />
1/8" 009999-098-00<br />
1/16" 009999-099-00<br />
Cryo tube<br />
2 m<br />
006124-020-00<br />
Teflon ferrules for cryo tube<br />
1 package (2 units)<br />
00<strong>27</strong>32-002-00<br />
Union nut 7/16” for LN2 cooling<br />
006936-000-00<br />
Al-seal for Agilent/HP mass flow controller<br />
1 package (5 units)<br />
004256-005-00<br />
82
GERSTEL ® approved supplies<br />
Part No.<br />
Part No.<br />
Stainless steel tubing<br />
1/16"<br />
1 m 003700-000-00<br />
2 m 003700-002-00<br />
4 m, purged<br />
with 1/8" adapter 007178-000-00<br />
Reducing capillary<br />
Stainless steel; 1 package (3 units)<br />
1/8" to 1/16", 300 mm 005226-000-00<br />
Fused silica capillary tubing for use as transfer line,<br />
make up gas capillary or splitter capillaries<br />
deactivated OD/ID length units Part No.<br />
0.31 mm/0.20 mm 2 m 1 008654-002-00<br />
5 m 1 008654-005-00<br />
0.35 mm/0.20 mm 10 m 1 009995-003-00<br />
0.45 mm/0.32 mm 10 m 1 009995-001-00<br />
25 m 1 009995-002-00<br />
0.25 mm/0.10 mm 10 m 1 009995-006-00<br />
25 m 1 009995-004-00<br />
0.70 mm/0.53 mm 10 m 1 009995-007-00<br />
25 m 1 009995-005-00<br />
0.31 mm/0.20 mm 10 m 1 009999-063-00<br />
25 m 1 009999-066-00<br />
0.20 mm/0.10 mm 25 m 1 009999-064-00<br />
0.<strong>27</strong> mm/0.10 mm 10 m 1 009999-065-00<br />
0.31 mm/0.20 mm 10 m 1 009999-067-00<br />
83
Trade marks<br />
The following trade marks are property of the companies listed below:<br />
Agilent Technologies ®<br />
Carbograph<br />
CarbotrapC, Carbopack,<br />
Carbowax ®<br />
Carboxen, Carbosieve<br />
Chromosorb ®<br />
Chromasorb;<br />
GERSTEL ®<br />
GRAPHPACK ®<br />
Hewlett Packard ® or HP<br />
Kalrez ®<br />
Microliter ®<br />
PEEK polymer<br />
PerkinElmer<br />
StableFlex <br />
Shimadzu ®<br />
SIEMENS<br />
Silcosteel ® , Sulfinert ® , Stabliwax ®<br />
Solid Phase Microextraction (SPME)<br />
Swagelok ®<br />
Teflon ® ; PTFE ® ; Vespel ®<br />
Tenax ®<br />
Tenax TA<br />
Thermo Finnigan ®<br />
Twister ®<br />
Varian<br />
Valco ®<br />
Viton ®<br />
(Agilent Technologies Inc.)<br />
(LARA s.r.l., Italy)<br />
(Supelco, Inc.)<br />
(Union Carbide)<br />
(Supelco, Inc.)<br />
(Manville Corporation, USA)<br />
(Johns Manville)<br />
(GERSTEL GmbH & Co.KG)<br />
(GERSTEL GmbH & Co.KG)<br />
(Hewlett-Packard Corp.)<br />
(DuPont Dow Elastomers.)<br />
(Hamilton Co.)<br />
(Victrex plc)<br />
(PerkinElmer Corp.)<br />
(Supelco, Inc.)<br />
(Shimadzu Scientific Instruments, Inc.)<br />
(Siemens AG)<br />
(Restek Corporation.)<br />
(Supelco)<br />
(Swagelok Co.)<br />
(E.I.Du Pont de Nemours Co, USA)<br />
(Enka Research Institute, Arnhem)<br />
(Buchem bv, Netherlands)<br />
(Thermo Seperation Products)<br />
(GERSTEL GmbH & Co.KG)<br />
(Varian Analytical Instruments)<br />
(Valco Instruments Co.)<br />
(DuPont Dow Elastomers.)<br />
84
Index<br />
Index<br />
Automated Liner EXchange, ALEX 28<br />
Glass insert for ALEX sample tray 29<br />
Ice blue septa 29<br />
O-rings 28, 29<br />
Tools 29<br />
Transport adapter 28<br />
ChemSensor Systems 78<br />
CI filaments 78<br />
Capillaries 79<br />
Direct interface 79<br />
Ferrules 79<br />
MSD adapter 79<br />
Vials, Caps 79<br />
Column Switching Systems, CS 70<br />
Column switching device 70<br />
Ferrule kit 71<br />
Fixing nut 71<br />
Mounting tool kit 70<br />
Restriction capillary 71<br />
Spare parts 70, 71<br />
GRAPHPACK ® Technique 4<br />
2M 4<br />
Adapter Swagelok female 6<br />
Adapter Swagelok male 7<br />
Detector adapter 8, 9<br />
Dual column injector 12, 13<br />
Dual Column Interface MSD 15<br />
Ferrules 5<br />
Injector adapter 10. 11<br />
Mounting tool 5<br />
Spare parts 5<br />
MSD adapter 14<br />
3D/2 16<br />
Column connector 18<br />
Crosspieces 19<br />
Spare parts 19<br />
Ferrules 17<br />
Mounting tool kit 19<br />
Spare parts 19<br />
Screws 17<br />
Sealing ferrule 17<br />
Cooled Injection Systems, CIS 20<br />
3D ferrule 25<br />
Adapter, 2M 22<br />
Adsorption tubes 22<br />
Cryo tube 25<br />
Dual column injector (GP-2M) 23<br />
Spare parts 23<br />
Fixing caps 21<br />
Glass liners 24, 25<br />
Mounting tool 3D 25<br />
Nut 22<br />
On-Column kit, spare parts 23<br />
Replaceable needles 26, <strong>27</strong><br />
Septum head 22<br />
Spare parts 22<br />
Septumless head 21<br />
Spare parts 21<br />
Silver seal 22<br />
Syringes 26, <strong>27</strong><br />
85
Index<br />
MultiPurpose Sampler, MPS 2 30<br />
Crimp cap vials 31<br />
Crimp caps 31, 32<br />
Crimper 34, 35<br />
Decapper 34<br />
Dilutor module 38<br />
Fiber holder 39<br />
Fibers 39,40. 41<br />
HSS injector syringes 37<br />
Spare parts 37<br />
Inserts for agitator 33, 41<br />
Microliter syringes 35, 36, 37<br />
Spare parts 35, 36, 37<br />
Screw cap vials 32, 33<br />
Screw caps 32, 33<br />
Septa 33<br />
Solvent bottle 34<br />
Caps and septa 60<br />
SPME sample vials 32<br />
Trays 41<br />
Vials 31, 32, 33<br />
MultiPurpose Sampler, MPS 3/3C/3 LC 42<br />
Crimper 44<br />
Dilutor module 46<br />
Microliter syringes 45<br />
Sample loop 47<br />
Sample vials 43<br />
Solvent bottle 43<br />
Caps and septa 43<br />
Syringe kit 44<br />
Spare parts 44<br />
Trays 47<br />
Olfactory Detector Port, ODP 76<br />
Crosspiece, 3D/2 77<br />
Detector adapter 77<br />
Ferrule (GP-2M) 5<br />
Humidifier vial 77<br />
Nose cones 76<br />
Nut 77<br />
Crosspiece kit 77<br />
Spare parts 77<br />
Silicone tubing – purge vial 76<br />
Splitter capillary 77<br />
Preparative Fraction Collector, PFC 72<br />
Capillaries 74, 75<br />
Effluent splitter 74<br />
Ferrule kit 74<br />
Mounting tool kit 73<br />
Sample traps 75<br />
Spare parts 75<br />
Sealing ferrule 73<br />
Switching divice 74<br />
Spare parts 73<br />
Trap adapter 75<br />
Pyrolysis Module, PM 1 64<br />
Spare parts 64, 65<br />
GERSTEL approved supplies 80<br />
Capillaries 83<br />
Cryo tube 82<br />
CU capillaries 80<br />
Reduced capillaries 83<br />
Reduced ferrules 82<br />
SS capillaries 80, 83<br />
Swagelok adapter SS 80<br />
Swagelok set 80<br />
Teflon ferrules 82<br />
Tools 81<br />
Tube adapter for VICI actuator 80<br />
Union nut 82<br />
86
Index<br />
Thermal Desorption System, TDS 56<br />
2M injector adapter 63<br />
Adapter for micro screw 63<br />
Adapters 63<br />
Spare parts 63<br />
Desorption tubes 58<br />
<strong>Supplies</strong> 61<br />
Direct interface 62<br />
Locking cone for TDS 2/3<br />
Spare parts 61<br />
Locking cone for TDS A<br />
Spare parts 61<br />
Micro ferrule 63<br />
Micro screw 63<br />
Sample tray for TDS A/A2<br />
Spare parts 69<br />
Septum head for liquid injection 57<br />
SLH calibration adapter 57<br />
Sorption tubes 60<br />
TDS tube adapter 57<br />
Transferline 62<br />
Twister ® 52<br />
Crimper 55<br />
Desorption tubes 53<br />
Decapper 55<br />
Forceps 53<br />
Mechanical crimper 55<br />
Twister Back Extraction 55<br />
Twister Headspace (HSSE) 54<br />
Vials, caps, septa 53, 54<br />
Twister Desorption Unit, TDU 48<br />
3D ferrule 51<br />
Glas insert for Twister sample tray 49<br />
Glas liners 50<br />
Mounting tool 51<br />
O-rings 49<br />
Recommended kit 48<br />
Septa 51<br />
Tools 51<br />
Transport adapter 49<br />
Twister desorption liner 49<br />
Thermal Extractor, TE 1/TE 2 66<br />
Desorptions tubes 58<br />
Spare parts 67<br />
Tube Conditioner, TC 1 68<br />
Spare parts 69<br />
87
Part No. Seite Part No. Seite Part No. Seite<br />
000976-005-00 8, 13<br />
000980-005-00 5<br />
001117-005-00 21, 22<br />
001268-005-00 9, 11, 22, 77, 79<br />
001362-005-00 10. 13<br />
001383-005-00 8, 9, 11<br />
001402-005-00 13<br />
001402-010-00 13<br />
001459-003-00 21<br />
001576-010-00 21, 22<br />
001705-007-00 17<br />
001705-008-00 17<br />
001705-020-00 17<br />
001705-025-00 17<br />
001705-031-00 17<br />
001705-040-00 17<br />
001705-045-00 17<br />
001805-000-00 79<br />
001805-007-00 5, 23<br />
001805-008-00 5<br />
001805-020-00 5<br />
001805-025-00 5<br />
001805-031-00 5<br />
001805-040-00 5, 79<br />
001805-045-00 5<br />
001905-007-00 63<br />
002425-010-00 24<br />
002426-005-00 23, 25, 51<br />
002426-010-00 25, 51<br />
002426-105-00 51<br />
002426-110-00 51<br />
00<strong>27</strong>32-002-00 82<br />
00<strong>27</strong>32-005-00 67<br />
002835-000-00 22<br />
002841-005-00 9, 11, 12, 22, 23, 79<br />
002930-010-00 24<br />
002931-010-00 24<br />
003079-000-00 25<br />
003089-064-00 21<br />
003091-047-00 23<br />
003091-064-00 21<br />
003424-000-00 19, 74, 73<br />
003700-000-00 83<br />
003700-002-00 83<br />
003701-000-00 80<br />
003702-000-00 80<br />
003714-005-00 23<br />
003962-005-00 8, 9<br />
004230-000-00 21<br />
004256-005-00 21, 82<br />
004921-000-00 80<br />
004922-000-00 80<br />
004923-000-00 80<br />
004938-000-00 5<br />
005002-010-00 75<br />
005002-028-00 75<br />
005010-000-00 75<br />
005014-000-00 75<br />
005014-005-0 0 62, 75<br />
005014-010-00 75<br />
005207-000-00 80<br />
005226-000-00 83<br />
005243-001-00 22<br />
005249-005-00 9, 11, 14, 79<br />
005344-002-00 77<br />
88<br />
005344-005-00 77<br />
005507-010-00 75<br />
005507-050-00 75<br />
005509-010-00 75<br />
005509-050-00 75<br />
005532-000-00 23<br />
005610-000-00 21<br />
005615-007-00 17<br />
005615-008-00 17<br />
005615-020-00 17<br />
005615-025-00 17<br />
005615-031-00 17<br />
005615-040-00 17<br />
005615-045-00 17<br />
006124-004-00 25<br />
006124-020-00 25, 82<br />
006144-047-00 23<br />
006144-064-00 21<br />
006188-000-00 19<br />
006285-000-00 76<br />
006460-000-00 22<br />
006508-007-00 8<br />
006508-031-00 8<br />
006508-040-00 77<br />
006508-045-00 8<br />
006509-007-00 10<br />
006509-031-00 10<br />
006509-045-00 10<br />
006511-007-00 9, 11<br />
006511-031-00 9, 11, 14<br />
006511-040-00 14, 81, 79<br />
006511-045-00 9, 11, 14<br />
006520-007-00 17, 73<br />
006520-008-00 17<br />
006520-020-00 17<br />
006520-025-00 17<br />
006520-031-00 17, 73<br />
006520-040-00 17, 73<br />
006520-045-00 17, 73<br />
006530-000-00 75, 74<br />
006558-001-00 77, 79<br />
006558-005-00 77<br />
006558-010-00 77<br />
006633-010-00 75<br />
006752-000-00 73<br />
006758-000-00 70<br />
006761-000-00 74<br />
006828-008-00 5<br />
006828-031-00 5<br />
006828-045-00 5<br />
006829-000-00 5<br />
006830-007-00 7<br />
006830-031-00 7<br />
006830-045-00 7<br />
006831-007-00 7, 8, 10<br />
006831-031-00 7, 8<br />
006831-045-00 7, 8, 10<br />
006832-007-00 7<br />
006832-031-00 7<br />
006832-045-00 7<br />
006833-007-00 6<br />
006833-031-00 6<br />
006833-045-00 6<br />
006834-007-00 6<br />
006834-031-00 6<br />
006834-045-00 6<br />
006835-007-00 6<br />
006835-031-00 6<br />
006835-045-00 6<br />
006936-000-00 82<br />
007178-000-00 83<br />
007233-031-00 15<br />
007233-040-00 15<br />
007233-045-00 15<br />
007236-005-00 15<br />
007259-007-00 22, 23<br />
007259-031-00 22<br />
007259-045-00 22<br />
007301-005-00 10. 13<br />
007302-007-00 10<br />
007302-031-00 10<br />
007302-045-00 10<br />
007304-000-00 75<br />
007304-001-00 78<br />
007304-005-00 71, 74<br />
007304-010-00 71, 74<br />
007348-005-00 15<br />
007361-000-00 71<br />
007464-007-00 11<br />
007464-031-00 11<br />
007464-045-00 11<br />
007513-064-00 21<br />
007514-000-00 22<br />
007519-010-00 24<br />
007530-031-00 12, 23<br />
007530-045-00 12, 23<br />
007533-007-00 13<br />
007533-031-00 13<br />
007533-045-00 13<br />
007541-005-00 23, 25, 51<br />
007541-010-00 25, 51<br />
007542-000-00 25<br />
007593-000-00 74<br />
007671-007-00 13<br />
007671-031-00 13<br />
007671-045-00 13<br />
007820-007-00 63<br />
007820-045-00 63<br />
007821-005-00 63<br />
007823-007-00 62<br />
007823-045-00 62<br />
007884-000-00 61, 65<br />
007887-004-00 80<br />
007887-008-00 80<br />
007887-016-00 80<br />
007910-007-00 63<br />
008005-007-00 9<br />
008005-031-00 9<br />
008005-045-00 9<br />
008012-000-00 76<br />
008019-007-00 11<br />
008019-031-00 11<br />
008019-045-00 11, 63<br />
008020-007-00 9<br />
008020-031-00 9<br />
008020-045-00 9<br />
008021-007-00 10<br />
008021-031-00 10<br />
008021-045-00 10<br />
008030-007-00 13
Part number index<br />
Part No. Seite Part No. Seite Part No. Seite<br />
008030-031-00 13<br />
008030-045-00 13<br />
008068-007-00 9, 11<br />
008068-031-00 9, 11<br />
008068-045-00 9, 11<br />
008174-010-00 60<br />
008189-007-00 8<br />
008189-031-00 8<br />
008189-045-00 8<br />
008190-007-00 8<br />
008190-031-00 8<br />
008190-045-00 8<br />
008191-007-00 9<br />
008191-031-00 9<br />
008191-045-00 9<br />
008192-007-00 9, 11<br />
008192-031-00 9, 11<br />
008192-045-00 9, 11<br />
008204-000-00 77<br />
008235-060-00 60<br />
008246-025-00 22<br />
008311-007-00 62<br />
008311-045-00 62<br />
008339-000-00 23<br />
008351-000-00 60<br />
008357-000-00 58<br />
008420-010-00 24<br />
008577-000-00 22<br />
008584-000-00 22<br />
008589-005-00 67<br />
008590-010-00 67<br />
008599-031-00 15<br />
008599-040-00 15<br />
008634-000-00 70<br />
008647-000-00 76<br />
008654-002-00 83<br />
008654-005-00 83<br />
008687-005-00 62<br />
008688-007-00 62<br />
008766-000-00 67<br />
008980-010-00 60<br />
008994-003-00 19<br />
008994-004-00 71<br />
008994-005-00 73<br />
008995-008-00 19, 71<br />
008995-031-00 19, 71<br />
008995-045-00 19, 71, 73<br />
009013-000-00 61, 65<br />
009013-001-00 61<br />
009040-007-00 13<br />
009040-031-00 13<br />
009040-045-00 13<br />
009095-005-00 61, 65<br />
009117-000-00 58<br />
009118-000-00 58<br />
009171-000-00 60<br />
009250-010-00 64<br />
009250-050-00 64<br />
009411-005-00 66<br />
009553-010-00 65<br />
009650-000-00 69<br />
009947-000-00 58<br />
009948-000-00 58<br />
009949-000-00 58<br />
009970-001-00 35<br />
009970-002-00 35<br />
009970-004-00 35<br />
009970-005-00 35<br />
009970-006-00 35<br />
009970-007-00 35<br />
009970-010-00 26<br />
009970-011-00 26<br />
009970-012-00 26<br />
009970-013-00 <strong>27</strong><br />
009970-014-00 <strong>27</strong><br />
009970-015-00 36<br />
009970-018-00 36<br />
009970-019-00 36<br />
009970-020-00 36<br />
009970-021-00 36<br />
009970-022-00 36<br />
009970-024-00 36<br />
009970-030-00 36<br />
009970-031-00 36<br />
009970-032-00 36<br />
009970-033-00 36<br />
009970-034-00 36<br />
009970-040-00 36<br />
009970-041-00 36<br />
009970-042-00 36<br />
009970-043-00 36<br />
009970-048-00 36<br />
009970-049-00 57<br />
009970-050-00 60<br />
009970-051-00 37<br />
009970-052-00 37<br />
009970-057-00 37<br />
009970-058-00 36<br />
009970-059-00 57<br />
009980-028-00 <strong>27</strong><br />
009980-029-00 <strong>27</strong><br />
009980-030-00 <strong>27</strong><br />
009980-031-00 <strong>27</strong><br />
009980-032-00 <strong>27</strong><br />
009980-033-00 <strong>27</strong><br />
009980-040-00 26<br />
009980-044-00 37<br />
009980-045-00 37<br />
009980-046-00 37<br />
009980-047-00 37<br />
009980-048-00 37<br />
009995-001-00 83<br />
009995-002-00 83<br />
009995-003-00 77, 83<br />
009995-004-00 83<br />
009995-005-00 83<br />
009995-006-00 83<br />
009995-007-00 83<br />
009996-059-00 26<br />
009999-006-00 26<br />
009999-010-00 21<br />
009999-014-00 21<br />
009999-015-00 21<br />
009999-016-00 21<br />
009999-017-00 26<br />
009999-018-00 26<br />
009999-019-00 26<br />
009999-021-00 26<br />
009999-025-00 53<br />
009999-041-00 <strong>27</strong><br />
009999-052-00 <strong>27</strong><br />
009999-063-00 83<br />
009999-064-00 83<br />
009999-065-00 87<br />
009999-066-00 83<br />
009999-067-00 83<br />
009999-073-00 81<br />
009999-074-00 82<br />
009999-079-00 81<br />
009999-080-00 81<br />
009999-081-00 81<br />
009999-082-00 81<br />
009999-083-00 81<br />
009999-084-00 81<br />
009999-085-00 81<br />
009999-086-00 81<br />
009999-087-00 81<br />
009999-088-00 82<br />
009999-089-00 82<br />
009999-090-00 82<br />
009999-091-00 11, 13, 82<br />
009999-092-00 9, 82<br />
009999-093-00 10. 15, 82<br />
009999-094-00 82<br />
009999-095-00 82<br />
009999-096-00 82<br />
009999-097-00 82<br />
009999-098-00 82<br />
009999-099-00 82<br />
009999-204-00 29, 51<br />
010040-000-00 58<br />
010041-000-00 58<br />
010042-000-00 58<br />
010044-000-00 58<br />
010372-005-00 61<br />
010375-007-00 9<br />
010375-031-00 9<br />
010375-045-00 9<br />
010441-000-00 61<br />
010454-003-00 57<br />
010454-004-00 57<br />
010649-000-00 58<br />
010649-010-00 58<br />
010650-000-00 58<br />
010650-010-00 58<br />
010849-010-00 24<br />
010850-010-00 24<br />
010906-002-00 80<br />
010963-005-00 62<br />
011003-000-00 62<br />
011004-000-00 62<br />
011005-000-00 62<br />
011025-007-00 62<br />
011025-045-00 62<br />
011061-005-00 61<br />
011222-001-00 52<br />
011222-002-00 52<br />
011229-000-00 75<br />
011333-001-00 52<br />
011333-002-00 52<br />
011444-001-00 52<br />
011444-002-00 52<br />
011555-001-00 52<br />
011555-002-00 52<br />
011619-000-00 60<br />
89
Part No. Seite Part No. Seite Part No. Seite<br />
011620-010-00 60<br />
011628-007-00 62<br />
011628-045-00 62<br />
011645-045-00 70<br />
011654-007-00 5<br />
011654-031-00 5<br />
011654-045-00 5<br />
011708-010-00 24<br />
011709-010-00 24<br />
011710-010-00 24<br />
011711-010-00 24<br />
011712-010-00 24<br />
011714-005-00 24<br />
011716-005-00 24<br />
011754-020-00 60<br />
011868-002-00 25<br />
011912-000-00 79<br />
011912-002-00 79<br />
012185-005-00 62<br />
012186-000-00 62<br />
012195-099-00 55<br />
012218-045-00 74<br />
012219-007-00 74<br />
012224-007-00 19<br />
012224-031-00 19<br />
012224-045-00 19<br />
012240-007-00 19, 77<br />
012240-031-00 19, 77<br />
012240-040-00 19<br />
012240-045-00 19, 77<br />
012260-005-00 58<br />
012<strong>27</strong>5-005-00 58<br />
012<strong>27</strong>6-005-00 58<br />
012<strong>27</strong>7-005-00 58<br />
012301-040-00 79<br />
012346-005-00 58<br />
012347-005-00 58<br />
012370-000-00 53<br />
012423-010-00 49<br />
012423-100-00 49<br />
012424-010-00 49<br />
012424-100-00 49<br />
012436-010-00 50<br />
012437-010-00 50<br />
012438-010-00 50<br />
012439-010-00 50<br />
012440-003-00 50<br />
012440-004-00 50<br />
012441-010-00 50<br />
012442-010-00 50<br />
012443-010-00 50<br />
012444-010-00 50<br />
012458-000-00 58<br />
012491-000-00 54<br />
012492-000-00 54<br />
012518-010-00 53, 69<br />
012565-100-00 49<br />
012659-010-00 60<br />
01<strong>27</strong>13-003-00 48<br />
01<strong>27</strong>13-004-00 48<br />
01<strong>27</strong>41-010-00 50<br />
01<strong>27</strong>42-010-00 50<br />
01<strong>27</strong>81-003-00 51<br />
90<br />
01<strong>27</strong>81-004-00 51<br />
013010-100-00 49<br />
013032-010-00 49<br />
013032-100-00 49<br />
013115-000-00 58<br />
013148-000-00 24<br />
013148-005-00 24<br />
013238-000-00 24<br />
013238-005-00 24<br />
013244-007-00 22, 23<br />
013244-031-00 22<br />
013244-045-00 22<br />
013247-005-00 24<br />
013248-005-00 24<br />
013249-005-00 24<br />
013250-005-00 24<br />
013329-000-00 57<br />
013343-004-00 80<br />
013343-008-00 80<br />
013343-016-00 80<br />
013407-007-00 18<br />
013407-031-00 18<br />
013407-040-00 18<br />
013407-045-00 18<br />
013409-010-00 50<br />
013431-031-00 18<br />
013440-040-00 18<br />
013445-031-00 18<br />
013445-040-00 18<br />
013445-045-00 18<br />
013492-000-00 19<br />
013493-007-00 77<br />
013493-031-00 77<br />
013493-045-00 77<br />
013507-007-00 18<br />
013507-031-00 18<br />
013507-040-00 18<br />
013507-045-00 18<br />
013508-045-00 18, 76<br />
013531-031-00 18<br />
013540-040-00 18<br />
013543-003-00 25<br />
013543-004-00 25<br />
013545-031-00 18<br />
013545-040-00 18<br />
013545-045-00 18<br />
013605-000-00 24<br />
013605-005-00 24<br />
013645-010-00 49<br />
013745-000-00 52<br />
013775-010-00 50<br />
013776-010-00 50<br />
013794-010-00 29<br />
013794-100-00 29<br />
013795-000-00 28<br />
013795-010-00 28<br />
013822-000-00 28<br />
013881-010-00 24<br />
013882-010-00 24<br />
013910-010-00 24<br />
013911-010-00 50<br />
013931-010-00 29<br />
013934-005-00 28<br />
014052-100-00 29, 51, 57<br />
014173-010-00 60<br />
014284-010-00 24<br />
014292-010-00 29<br />
014292-100-00 29<br />
014454-000-00 57<br />
014454-021-00 57<br />
014456-005-00 57<br />
089280-009-00 54<br />
089280-010-00 54<br />
089345-092-00 78<br />
089355-076-00 32, 43, 53<br />
093611-010-00 36<br />
093611-020-00 44<br />
093611-021-00 44<br />
093611-022-00 44<br />
093611-026-00 44<br />
093611-0<strong>27</strong>-00 38, 46<br />
093611-028-00 38<br />
093611-029-00 38<br />
093611-032-00 38<br />
093611-033-00 38<br />
093611-034-00 38, 46<br />
093631-002-00 33, 41<br />
093631-007-00 41, 47<br />
093631-008-00 41, 47<br />
093631-009-00 41, 47<br />
093631-010-00 47<br />
093631-054-00 34, 43<br />
093631-055-00 34, 43<br />
093631-068-00 41, 47<br />
093631-069-00 41, 47<br />
093631-080-00 41, 47<br />
093631-084-00 41, 47<br />
093631-086-00 41, 47<br />
093631-091-00 38, 46<br />
093631-092-00 38, 46<br />
093631-093-00 38, 46<br />
093631-094-00 38, 46<br />
093631-095-00 38, 46<br />
093631-096-00 38, 46<br />
093632-038-00 38, 46<br />
093632-039-00 38, 46<br />
093632-040-00 38, 46<br />
093632-041-00 38, 46<br />
093632-043-00 38, 46<br />
093632-045-00 38, 46<br />
093632-050-00 34<br />
093639-000-00 39<br />
093639-001-00 39<br />
093639-005-00 39<br />
093639-009-00 40<br />
093639-013-00 40<br />
093639-020-00 39<br />
093639-021-00 39<br />
093639-022-00 39<br />
093639-023-00 39<br />
093639-024-00 40<br />
093639-025-00 40<br />
093639-026-00 40<br />
093639-0<strong>27</strong>-00 40<br />
093639-028-00 40<br />
093639-029-00 40
Part number index<br />
Part No. Seite Part No. Seite Part No. Seite<br />
093639-030-00 40<br />
093639-031-00 41<br />
093640-000-00 34, 44<br />
093640-001-00 34, 55<br />
093640-002-00 34, 44<br />
093640-003-00 34, 55<br />
093640-004-00 31, 43<br />
093640-005-00 31, 53<br />
093640-006-00 31, 53<br />
093640-007-00 31, 43<br />
093640-008-00 31<br />
093640-009-00 55<br />
093640-010-00 35<br />
093640-012-00 35<br />
093640-015-00 31<br />
093640-017-00 35<br />
093640-018-00 35<br />
093640-019-00 35<br />
093640-020-00 35<br />
093640-021-00 35<br />
093640-022-00 35<br />
093640-023-00 35<br />
093640-024-00 35<br />
093640-025-00 35<br />
093640-029-00 32, 43<br />
093640-031-00 32<br />
093640-032-00 32<br />
093640-034-00 32<br />
093640-035-00 32<br />
093640-036-00 32<br />
093640-037-00 32<br />
093640-038-00 32<br />
093640-039-00 32<br />
093640-040-00 32<br />
093640-041-00 32<br />
093640-042-00 32<br />
093640-043-00 32<br />
093640-045-00 33, 43<br />
093640-046-00 33, 43<br />
093640-047-00 33, 43<br />
093640-048-00 33, 43<br />
093640-050-00 32<br />
093640-052-00 31, 43<br />
093640-053-00 31, 43<br />
093640-054-00 34, 44<br />
093640-055-00 34<br />
093640-056-00 33<br />
093640-057-00 33<br />
093640-058-00 33, 44<br />
093640-059-00 33<br />
093640-062-00 31<br />
093640-063-00 31<br />
093640-064-00 31<br />
093711-000-00 45<br />
093711-001-00 45<br />
093711-002-00 45<br />
093711-003-00 45<br />
093711-004-00 45<br />
093711-005-00 45<br />
093711-006-00 45<br />
093711-007-00 44<br />
093711-008-00 44<br />
093711-009-00 44<br />
093711-010-00 44<br />
093711-011-00 44<br />
093711-012-00 44<br />
093711-013-00 44<br />
093711-014-00 45<br />
093711-019-00 44<br />
093711-020-00 44<br />
093711-021-00 44<br />
093711-022-00 46<br />
093711-023-00 46<br />
093711-026-00 44<br />
093711-0<strong>27</strong>-00 45<br />
093711-028-00 45<br />
093711-038-00 45<br />
093711-039-00 45<br />
093711-040-00 45<br />
093711-041-00 45<br />
093711-042-00 45<br />
093711-043-00 45<br />
093711-044-00 45<br />
91