WATER REQUIREMENTS IN CIVIL USERS<br />
NUMBER OF<br />
APARTMENTS<br />
WITH FLUSH TANK WC WITH CONTROLLED FLUSHING SYSTEM WC<br />
1 2 1 2<br />
Flow rate (l/min)<br />
100 317 395 604 787<br />
120 347 433 662 863<br />
140 375 468 715 932<br />
160 401 500 764 996<br />
180 425 530 811 1056<br />
200 448 559 854 1114<br />
220 470 586 896 1168<br />
240 491 612 936 1220<br />
260 511 637 974 1270<br />
280 530 661 1011 1318<br />
300 549 685 1047 1364<br />
320 567 707 1081 1408<br />
340 584 729 1114 1452<br />
360 601 750 1146 1494<br />
380 618 771 1178 1535<br />
400 634 791 1208 1575<br />
450 672 838 1282 1670<br />
Note: For seaside resorts, a flow rate increased by at least 20% must be<br />
considered.<br />
TYPE<br />
Sink<br />
Dishwasher<br />
Bathtub<br />
Washbasin<br />
Bidet<br />
Flush tank WC<br />
Washing machine<br />
Shower<br />
Controlled flushing system WC<br />
FLOW RATE<br />
l/min<br />
9<br />
10<br />
15<br />
6<br />
6<br />
6<br />
12<br />
12<br />
90<br />
27