3/18/2013<br />
Cardiac Output Measurement<br />
Indocyanine Green Method<br />
• Sources of Error<br />
– Indocyanine green unstable over time <strong>and</strong> with<br />
exposure <strong>to</strong> light<br />
– Sample must be introduced rapidly as single bolus<br />
– Bolus size must be exact<br />
– Indica<strong>to</strong>r must mix thoroughly with blood, <strong>and</strong> should<br />
be injected just proximal or in<strong>to</strong> cardiac chamber<br />
– Dilution curve must have exponential downslope of<br />
sufficient length <strong>to</strong> extrapolate curve. Invalid in Low<br />
cardiac output states <strong>and</strong> shunts that lead <strong>to</strong> early<br />
recirculation<br />
– Withdrawal rate of arterial sample must be constant<br />
Baim DS: Grossman’s Cardiac Catheterization, Angiography, <strong>and</strong> Intervention. 7 th Edition. Lippincot Williams<br />
<strong>and</strong> Wilkins, 2007.<br />