Final <strong>Report</strong> – 813 8385 1<br />

Metallurgical Analysis <strong>of</strong> 24-Inch Houstonia 200 Service <strong>Failure</strong> at MP 21.6 (8/25/08)<br />

Page 19<br />

OD<br />

ID<br />

Figure 9. Stereo light photomicrograph <strong>of</strong> the rupture area indicated in Figure 8<br />

(Mount M1, 4% Nital Etchant).<br />

Figure 10.<br />

Light photomicrograph <strong>of</strong> the external surface <strong>of</strong> the pipe in Mount<br />

M1 (4% Nital Etchant, area indicated in Figure 8).<br />