Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

.03 Pressure<br />

Transducers<br />

.04 Pressure<br />

Recorders<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Calibration <strong>of</strong><br />

Pressure<br />

Transducers<br />

Calibration <strong>of</strong><br />

Pressure<br />

Recorders<br />

Calibration <strong>of</strong><br />

.07 Digital<br />

Manometers Digital Manometers<br />

.08 Pressure Calibration <strong>of</strong><br />

Control Pressure Control<br />

Devices<br />

Devices<br />

5.22 Force Me<strong>as</strong>uring Devices<br />

.02 El<strong>as</strong>tic Force Calibration <strong>of</strong><br />

Me<strong>as</strong>uring El<strong>as</strong>tic Force<br />

Devices Me<strong>as</strong>uring Devices<br />

.04 Force Gauges Calibration <strong>of</strong> Force<br />

Gauges<br />

Range to be<br />

calibrated<br />

Page 6 <strong>of</strong> 427<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

1000 psi to 10000 psi ± 5 psi<br />

0 to 1000 psi ± 0.5 psi<br />

0 to 1000 psi ± 0.5 psi<br />

0 to 2000 mbar ± 1 mbar<br />

0 to 1000 psi ± 0.5 psi<br />

Standard Method/<br />

Reference Standard<br />

up to 100 kg ± 0.001 kg In-house calibration/<br />

On-site calibration<br />

TR-WI-FOR-003<br />

up to 100 g<br />

100 g to 2000 g<br />

2 kg to 5 kg<br />

5 kg to 20 kg<br />

20 kg to 50 kg<br />

50 kg to 100 kg<br />

± 0.000 2 g<br />

± 0.01 g<br />

± 0.04 g<br />

± 0.001 kg<br />

± 0.002 kg<br />

± 0.003 kg<br />

In-house calibration/<br />

On-site calibration<br />

TR-WI-FOR-001<br />

TR-WI-FOR-003<br />

5.24 Torque Me<strong>as</strong>uring Devices<br />

.01 Torque<br />

Wrenches<br />

Calibration <strong>of</strong><br />

Torque Wrenches<br />

up to 100 kgf.cm ± 0.1 kgf.cm In-house calibration<br />

TR-WI-TOR-001<br />

.02 Torque Calibration <strong>of</strong><br />

up to 100 kgf.cm ± 0.06 kgf.cm<br />

Transducers Torque Meters<br />

.04 Other Devices Calibration <strong>of</strong><br />

up to 100 kgf.cm ± 0.06 kgf.cm<br />

Torque Devices<br />

5.28 Resistors, Resistance Boxes and Potential Dividers<br />

.01 Precision<br />

Resistors,<br />

Resistance<br />

Boxes and<br />

Conductance<br />

Boxes<br />

Calibration <strong>of</strong><br />

Resistance Boxes<br />

0 to 100 MΩ ± 0.01 % In-house calibration/<br />

On-site calibration<br />

TR-WI-RES-001<br />

.05 Other Devices Calibration <strong>of</strong><br />

Resistance Devices<br />

5.34 Electrical Instrument Calibrators<br />

.01 DC Voltage Calibration <strong>of</strong> DC<br />

Voltage Sources<br />

.02 AC Voltage Calibration <strong>of</strong> AC<br />

Voltage Sources @<br />

60 Hz only<br />

.03 DC Current Calibration <strong>of</strong> DC<br />

Current Sources<br />

.04 AC Current Calibration <strong>of</strong> AC<br />

Current Sources @<br />

60 Hz only<br />

.05 Resistance Calibration <strong>of</strong><br />

Resistance<br />

Sources<br />

5.35 Indicating and Recording Instruments<br />

.01 DC Voltmeters Calibration <strong>of</strong> DC<br />

Voltmeters<br />

.03 DC Ammeters Calibration <strong>of</strong> DC<br />

Ammeters<br />

.09 Ohmmeters Calibration <strong>of</strong><br />

Ohmmeters<br />

0 to 100 MΩ ± 3 %<br />

0 to 1000 V ± 0.01 % In-house calibration/<br />

On-site calibration<br />

TR-WI-VOL-001<br />

0 to 1000 V ± 0.1 % In-house calibration/<br />

On-site calibration<br />

TR-WI-VOL-002<br />

0 to 3 A ± 0.1 % In-house calibration/<br />

On-site calibration<br />

TR-WI-CUR-001<br />

0 to 3 A ± 0.5 % In-house calibration/<br />

On-site calibration<br />

TR-WI-CUR-002<br />

0 to 100 MΩ ± 3 % In-house calibration/<br />

On-site calibration<br />

TR-WI-RES-001<br />

0 to 1 000 V ± 0.01 % In-house calibration/<br />

On-site calibration<br />

TR-WI-VOL-003<br />

0 to 30 A ± 0.1 % In-house calibration/<br />

On-site calibration<br />

TR-WI-CUR-003<br />

0 to 100 MΩ ± 3 % In-house calibration/<br />

On-site calibration