Setup<br />

WARNING<br />

FIRE AND EXPLOSION HAZARD<br />

Proper electrical grounding is essential<br />

to reduce the risk of fire or explosion<br />

which can result in serious injury and<br />

property damage. Also read FIRE OR<br />

EXPLOSION HAZARD on page 4.<br />

1. Connect gun, 3 ft. hose (78) and 50 ft. hose (79).<br />

Don’t install spray tip yet.<br />

2. Two gun hookup. Remove cap (12) from 1/4<br />

npsm(m) secondary hose outlet and attach minimum<br />

50 ft. long hose. For more flexible gun movement,<br />

install 3/16 in. ID, 3 ft. whip hose between<br />

main hose and gun.<br />

WARNING<br />

If you supply your own hoses and spray gun, be<br />

sure the hoses are electrically conductive, that<br />

the gun has a tip guard, and that each part is<br />

rated for at least 3000 psi (21.0 MPa, 210 bar )<br />

Working Pressure. This is to reduce the risk of<br />

serious injury caused by static sparking, fluid<br />

injection or over-pressurization and rupture of<br />

the hose or gun.<br />

CAUTION<br />

To avoid damaging the pressure control, which may<br />

result in poor equipment performance and component<br />

damage, follow these precautions:<br />

1. Always use a nylon spray hose at least 50 ft.<br />

(15 m) long.<br />

2. Never use a wire braid hose as it is too rigid to<br />

act as a pulsation dampener.<br />

3. Never install any shutoff device between the<br />

sprayer outlet (D) and the hose. See Fig. 2.<br />

3. Fill packing nut/wet–cup (E)1/3 full with <strong>Graco</strong><br />

Throat Seal Liquid (TSL), supplied.<br />

4. Check electrical service. Be sure electrical service<br />

is 120 Vac, 60 Hz, 20 A. Use properly grounded<br />

outlet. Do not remove grounding prong of power<br />

supply cord or of any extension cords used. Do not<br />

use an adapter. Extension cords must have 3<br />

wires of minimum 12 gauge size. Long extension<br />

cords reduce sprayer performance. If 20 amp<br />

service is not available, set 15/20 amp switch (C)<br />

to 15 amp to avoid nuisance tripping of circuit<br />

breakers.<br />

5. With ON/OFF switch (A) set to OFF, plug cord into<br />

a grounded electrical outlet located at least 20 ft.<br />

(6 m) away from spray area. See Fig. 2<br />

6. Flush pump to remove lightweight oil which was<br />

left in to protect pump parts after factory testing.<br />

See page 10.<br />

12<br />

C<br />

78<br />

<br />

E<br />

79<br />

<br />

D<br />

<br />

B<br />

55<br />

A<br />

<br />

Do not install any shutoff device here<br />

Fill packing nut 1/3 full with TSL<br />

118<br />

<br />

<br />

Fig. 2