Setup<br />
WARNING<br />
FIRE AND EXPLOSION HAZARD<br />
Proper electrical grounding is essential<br />
to reduce the risk of fire or explosion<br />
which can result in serious injury and<br />
property damage. Also read FIRE OR<br />
EXPLOSION HAZARD on page 4.<br />
1. Connect gun, 3 ft. hose (78) and 50 ft. hose (79).<br />
Don’t install spray tip yet.<br />
2. Two gun hookup. Remove cap (12) from 1/4<br />
npsm(m) secondary hose outlet and attach minimum<br />
50 ft. long hose. For more flexible gun movement,<br />
install 3/16 in. ID, 3 ft. whip hose between<br />
main hose and gun.<br />
WARNING<br />
If you supply your own hoses and spray gun, be<br />
sure the hoses are electrically conductive, that<br />
the gun has a tip guard, and that each part is<br />
rated for at least 3000 psi (21.0 MPa, 210 bar )<br />
Working Pressure. This is to reduce the risk of<br />
serious injury caused by static sparking, fluid<br />
injection or over-pressurization and rupture of<br />
the hose or gun.<br />
CAUTION<br />
To avoid damaging the pressure control, which may<br />
result in poor equipment performance and component<br />
damage, follow these precautions:<br />
1. Always use a nylon spray hose at least 50 ft.<br />
(15 m) long.<br />
2. Never use a wire braid hose as it is too rigid to<br />
act as a pulsation dampener.<br />
3. Never install any shutoff device between the<br />
sprayer outlet (D) and the hose. See Fig. 2.<br />
3. Fill packing nut/wet–cup (E)1/3 full with <strong>Graco</strong><br />
Throat Seal Liquid (TSL), supplied.<br />
4. Check electrical service. Be sure electrical service<br />
is 120 Vac, 60 Hz, 20 A. Use properly grounded<br />
outlet. Do not remove grounding prong of power<br />
supply cord or of any extension cords used. Do not<br />
use an adapter. Extension cords must have 3<br />
wires of minimum 12 gauge size. Long extension<br />
cords reduce sprayer performance. If 20 amp<br />
service is not available, set 15/20 amp switch (C)<br />
to 15 amp to avoid nuisance tripping of circuit<br />
breakers.<br />
5. With ON/OFF switch (A) set to OFF, plug cord into<br />
a grounded electrical outlet located at least 20 ft.<br />
(6 m) away from spray area. See Fig. 2<br />
6. Flush pump to remove lightweight oil which was<br />
left in to protect pump parts after factory testing.<br />
See page 10.<br />
12<br />
C<br />
78<br />
<br />
E<br />
79<br />
<br />
D<br />
<br />
B<br />
55<br />
A<br />
<br />
Do not install any shutoff device here<br />
Fill packing nut 1/3 full with TSL<br />
118<br />
<br />
<br />
Fig. 2