You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Pump<br />
SV 40 B air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T4 (10 °C < T a > 40 °C) X<br />
SV 65 B air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T4 (10 °C < T a > 40 °C) X<br />
SV 100 B air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T4 (10 °C < T a > 40 °C) X<br />
SV 120 B air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T4 (10 °C < T a > 40 °C) X<br />
SV 200 air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T3 (10 °C < T a > 40 °C) X<br />
SV 200 water cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T3 (10 °C < T a > 40 °C) X<br />
SV 300 air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T3 (10 °C < T a > 40 °C) X<br />
SV 300 water cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 2G IIC T3 (10 °C < T a > 40 °C) X<br />
SV 630 B air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 3GD IIC T3 (150 °C) (10 < T a > 40 °C) X<br />
SV 630 BF water cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 3GD IIC T3 (150 °C) (10 < T a > 40 °C) X<br />
SV 750 B air cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 3GD IIC T3 (150 °C) (10 < T a > 40 °C) X<br />
SV 750 BF water cooled<br />
Ex II (i) 2G b IIB + H2 T3 /<br />
(o) 3GD IIC T3 (150 °C) (10 < T a > 40 °C) X<br />
Ultimate pressure (mbar (Torr))<br />
Part No. without gas ballast with gas ballast<br />
960305A22 0.5 (0.38) 1.5 (1.13)<br />
960405A22 0.5 (0.38) 1.5 (1.13)<br />
960505A22 0.5 (0.38) 1.5 (1.13)<br />
upon request 0.5 (0.38) 1.5 (1.13)<br />
10927A22 0.15 (1.13) 0.7 (0.53)<br />
1092702A22 0.15 (1.13) 0.7 (0.53)<br />
10931A22 0.15 (1.13) 0.7 (0.53)<br />
1093102A22 0.15 (1.13) 0.7 (0.53)<br />
upon request 0.15 (1.13) 0.7 (0.53)<br />
upon request 0.15 (1.13) 0.7 (0.53)<br />
upon request 0.15 (1.13) 0.7 (0.53)<br />
upon request 0.15 (1.13) 0.7 (0.53)<br />
ATEX outside Dust: upon request. For SV 630 B(F): as on existing Cat 3 pumps.<br />
SV 630 B(F) and SV 750 B(F) are ATEX Cat 3 only outside.<br />
Gas ballast connection: with DN 16 ISO-KF as on Cat 3 pumps. Manual gas ballast is standard.<br />
SV 40 B to SV 120 B with manual gas ballast are T3 inside. Pumps with permanent gas ballast are T4 inside.<br />
Big gas ballast available upon request.<br />
For all enquiries and orders relating to category 1 and 2 ATEX products please exclusively use our ATEX questionnaire.<br />
You can find this questionnaire at the end of the full-line catalog together with the fax forms or<br />
in the Internet under “www.<strong>oerlikon</strong>.com/leyboldvacuum” under Download Documents in the area Documentation.<br />
Oerlikon Leybold Vacuum Full Line Catalog<br />
59 C02