<strong>3T</strong> <strong>Portable</strong><br />

Technical Specifications<br />

System<br />

Configuration<br />

Performance<br />

Response<br />

Output sensitivity<br />

Peak output<br />

Cross axis rejection<br />

Linearity<br />

Lowest spurious<br />

resonance<br />

Self-noise<br />

Dynamic range<br />

Calibration<br />

Type<br />

Calibration controls<br />

Mass Locking<br />

Locking<br />

Mass position output<br />

band<br />

Mass recentring range<br />

Sensitivity<br />

Response<br />

Level<br />

Power<br />

Power consumption<br />

Power supply<br />

Optional low power<br />

sensor<br />

Protection<br />

Control<br />

Mass control / locking<br />

Offset zeroing<br />

Triaxial orthogonal sensors<br />

120s – 50Hz standard<br />

Other options available<br />

-1 -1<br />

2 × 750 V/ms (1500 V/ms )<br />

Other options available<br />

±10 V differential<br />

Over 65dB; sensor axes<br />

orthogonal to within ± 0.05°<br />

> 107dB horizontal, > 111dB<br />

vertical<br />

> 140Hz (vertical)<br />

Measured Self noise below the<br />

NLNM from >200s to 20Hz<br />

(Vertical)<br />

> 140dB over the entire passband<br />

Pulse, sine wave and broadband<br />

Independent signal & enable lines<br />

exposed on sensor connector<br />

Remote or automatic electronic<br />

mass locking, unlocking and<br />

centring<br />

DC – 120 seconds<br />

± 2.5° from horizontal<br />

2<br />

510 V-s /m, nominal<br />

Flat to acceleration, DC to 120s<br />

20 Vp-p, maximum<br />

0.744W<br />

10 – 36V DC<br />

5V DC supply (output ±4.5 V)<br />

Polarity, power fail, signal<br />

overload<br />

Remote locking, unlock and<br />

centring<br />

Automatic<br />

Environmental<br />

Operating Temperature<br />

Operating Temperature<br />

sensitivity<br />

Storage Temperature<br />

Instrument Levelling<br />

Case integrity<br />

Shock<br />

Humidity<br />

Auto recovery time<br />

Alignment<br />

Physical<br />

Dimensions<br />

Enclosure<br />

Weight<br />

Handling<br />

Connectors<br />

Part Numbers<br />

<strong>3T</strong> <strong>Portable</strong><br />

<strong>3T</strong> <strong>Portable</strong> with power<br />

cable<br />

<strong>3T</strong> portable with power<br />

cable and handheld<br />

control unit<br />

<strong>3T</strong> Hybrid<br />

–20 to +75°C (–55°C option)<br />