Computer Controlled Multi-Clamp with Software<br />

DATA ACQUISITION & ANALYSIS SYSTEM<br />

This unique package integrates the amplifiers, data acquisition system, and analysis software all in<strong>to</strong> one convenient box!<br />

The system provides individual data acquisition and control for 2, 4 or 6 chambers and is fully compatible with the NaviCyte<br />

horizontal/vertical diffusion chamber systems. Windows 95/98/2000/XP compatible.<br />

Software Features Includes:<br />

• Au<strong>to</strong>matic compensation of fluid resistance and electrode<br />

potential during the experiment<br />

• Individual voltage clamp, current clamp or open circuit<br />

control for each chamber<br />

• Overlay of uni- or bipolar current pulses with variable<br />

parameters for dynamic definition of G t /R t<br />

• I/V and V/I curves with freely adjustable parameters<br />

• Minimum pulse duration 200 ms, max. amplitude<br />

±250 µA for dynamic definition of G t /R t<br />

• Ability <strong>to</strong> input marker and comments and save with<br />

data file<br />

• Prin<strong>to</strong>ut of parameters in variable timetable<br />

• Data format compatible <strong>to</strong> Excel<br />

• Continuous graphics display<br />

• Experiment time up <strong>to</strong> 8 hours<br />

GUIDE TO USSING CHAMBER SYSTEMS<br />

The Computer Controlled Multi-Clamp with Software is a combined<br />

voltage/current clamp and data acquisition system in one compact<br />

microcomputer controlled unit. In its full configuration it can be used <strong>to</strong><br />

control and collect electrophysiological data from up <strong>to</strong> six NaviCyte<br />

horizontal or vertical diffusion chambers.<br />

The system provides independent chamber control in three different<br />

modes: voltage clamp, current clamp, and open circuit. An change<br />

between these modes is possible during the experiment at each time point.<br />

The Multi-Clamp is available in 2-, 4- or 6-channel configurations and is<br />

fully compatible with both NaviCyte <strong>Ussing</strong> chamber systems. The clamp<br />

provides a separate A/D converter and isolated current source for each<br />

chamber, and current and voltage electrodes from each half-cell are<br />

connected <strong>to</strong> the Multi-Clamp via an electrode manifold. Data exchange<br />

between the PC and the Multi-Clamp is via standard COM ports, and<br />

depending on the number of ports available, a single PC can handle<br />

several clamps.<br />

An interesting option consists of the incorporation of a gas delivery<br />

system in<strong>to</strong> a NaviCyte/Multi-Clamp system. This gas delivery system<br />

consists of 12 precision gas flow meters mounted <strong>to</strong> a stabilizing base<br />

and connect <strong>to</strong> a 6-channel NaviCyte vertical or horizontal chamber<br />

systems. The 600 x 400 mm stabilizing base also houses an electrode<br />

manifold for connecting each Ag/AgCl electrodes <strong>to</strong> their respective<br />

half-cells.<br />

Software<br />

The Multi-Clamp system comes complete with an easy <strong>to</strong> use Windows<br />

95/98/2000/XP based control and data acquisition software package<br />

that allows for the individual control and moni<strong>to</strong>ring of each chamber.<br />

Specifications<br />

Channels 2, 4 or 6<br />

A/D Subsystem for<br />

Analog Data Acquisition 13 Bit<br />

Current Source by D/A 12 Bit, isolated<br />

Serial Connection <strong>to</strong> PC COM1/COM2 for bi-directional<br />

data transfer<br />

Case Dimensions<br />

24.5 x 11.4 x 19.7 cm<br />

(9.6 x 4.5 x 7.8 in)<br />

Power<br />

100/230 VAC, 50/60 Hz<br />

Input Resistance<br />

> 10 9 Ω differential<br />

Input Current<br />

< 100 pA<br />

Input Voltage<br />

±400 mV, 0.1 mV step<br />

Current Output<br />

±2000 µA, 1 µA step<br />

Product of Current and<br />

External Resistance Max 13 V<br />

Order # Description<br />

69-0300 2-Channel voltage/current clamp system<br />

with software<br />

69-0301 4-Channel voltage/current clamp system<br />

with software<br />

69-0302 6-Channel voltage/current clamp system<br />

with software<br />

66-0025 6-Channel electrode manifold for NaviCyte<br />

chamber systems<br />

Perfusion and Electrical Accessories<br />

69-0303 12-Channel precision flow-meter and<br />

electrode manifold<br />

66-0025 6-channel electrical manifold for NaviCyte<br />

chamber systems<br />

Warner Instruments • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com<br />