D 7700 F page 12<br />

Table 20: Additional features for actuations<br />

Type of actuation / Suffix Description Example Symbols<br />

coding<br />

A, EA, HA, PA, C 1 Manual actuation without h<strong>and</strong> lever EA 1, C 1 1 2<br />

A, EA, HA, PA, C 2 Manual actuation with short h<strong>and</strong> lever. For dimensions see sect. 5.3. EA 2, A 2<br />

A, EA, HA, C<br />

V<br />

VA<br />

VB<br />

VC<br />

VCHO<br />

VCHC<br />

Mechanical micro switch (size 3 only), for monitoring the <strong>spool</strong>'s idle<br />

position, (for data of the switch, see sect. 4.3<br />

V - Signal with start of movement, direction A or B (no side indication)<br />

VA - Signal with start of movement, direction A<br />

VB - Signal with start of movement, direction B<br />

VC - Signal with start of movement, direction A <strong>and</strong> B (separate<br />

side indication)<br />

VCHO - Signal with start of movement, direction A <strong>and</strong> B separate<br />

(2xNO-contact<br />

VCHC - Signal with start of movement, direction A <strong>and</strong> B separate<br />

(2xNC-contact<br />

EA VA,<br />

A1VB,<br />

CVC<br />

VB<br />

VA<br />

VC<br />

A, EA, C N, N1 Proximity switch (size 3 only), for monitoring the <strong>spool</strong>'s idle position<br />

(no side indication), for data, see sect. 4.3.<br />

Type N1- only mechanical setup: Proximity switch is customer furnished<br />

(8x8x33mm central sensor area).<br />

A, EA, C, PA, K WA<br />

WA-EX n<br />

Integrated displacement transducer (Hall-sensor) with analogous signal<br />

output (lift monitoring)<br />

(WA-EX n, explosion-proof version conf. Ex nA II T4 X)<br />

EA N,<br />

A1N1<br />

EA W,<br />

A1W,<br />

EA BW<br />

WA<br />

U<br />

A, EA, C, PA, K U Integrated <strong>spool</strong> monitoring for side indication (Triggered signal: ON / OFF) EA U<br />

E, EA, HEA T<br />

TH<br />

Additional manual emergency actuation for the solenoid at the integrated<br />

prop. Pressure reducing <strong>valve</strong>. Version TH with additional pushbutton for<br />

actuation without tool<br />

ET, EA 1 T,<br />

EW TH<br />

T<br />

A, C, E, E0A G Reinforced version of the spring cover, suitable if high pressure surges<br />

are expected in the gallery T.<br />

E, EA,HEA B, BT Solenoid with quarter turn <strong>type</strong> plug (Bayonet PA 6, Co. Schlemmer<br />

D-85586 Poing, suited for taper with bayonet 10 SL), version BT with<br />

additional manual emergency actuation. Plug is not scope of delivery.<br />

ET 1 G, CG,<br />

A1G<br />

EB, EAB,<br />

EA 1B