70,00<br />

0,600<br />

60,00<br />

pressure pulse<br />

dies out<br />

0,500<br />

50,00<br />

0,400<br />

delta p [bar]<br />

40,00<br />

30,00<br />

0,300<br />

pp without dep<br />

pp with dep<br />

derivative of dep curve<br />

0,200<br />

20,00<br />

10,00<br />

deposit<br />

0,100<br />

0,00<br />

0,000<br />

0,00 100,00 200,00 300,00 400,00 500,00 600,00<br />

time[s]<br />

Figure 17 Pressure pulse at full production<br />

0,90<br />

0,00200<br />

0,80<br />

0,70<br />

depost it<br />

0,00180<br />

0,00160<br />

0,60<br />

0,00140<br />

0,00120<br />

0,50<br />

pp wit hout dep<br />

0,00100<br />

pp wit h dep<br />

0,40<br />

derivat ive of dep curve<br />

0,00080<br />

0,30<br />

0,00060<br />

0,20<br />

0,00040<br />

0,10<br />

0,00020<br />

0,00<br />

0,00000<br />

0,00 50,00 100,00 150,00 200,00 250,00 300,00 350,00 400,00 450,00 500,00<br />

time [s]<br />

Figure 18 Pressure pulse with reduced flow<br />

Deposits Detection Using Pressure Pulse Technology<br />

<strong>Ormen</strong> <strong>Lange</strong> Pipelines Case Study Using Process Simulation Tools<br />

35