canfield connector<br />

8510 Foxwood Court<br />

Youngstown, Ohio 44514<br />

(330) 758-8299 ■ Fax: (330) 758-8912<br />

www.canfieldconnector.com<br />

MODEL iLA<br />

DC TO AC IN-LINE<br />

VOLTAGE AND CURRENT AMPLIFIER<br />

General Description<br />

The <strong>Canfield</strong> <strong>Connector</strong> In-Line Amplifier (iLA) is commonly used with small DC sensors to convert and amplify the output<br />

for use with AC supplies, PLCs and loads. With the iLA, a DC sinking (NPN) sensor can become an AC sensor. Standard<br />

features include fully solid state circuitry and surge suppression isolation for the sensor. No mounting is necessary, as the<br />

iLA is simply a part of the cable assembly. Additional features include on board indicator light depicting power, the availability<br />

of either multi-conductor cable or 8mm connector, and 500 mA output. The iLA’s compact package allows for the<br />

use of sub-miniature DC sensors without addition of transformers and DC power supplies.<br />

Dimensional Data<br />

ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED<br />

To AC input/output<br />

iLA<br />

To sinking (NPN) Sensor<br />

*Series 9B-42<br />

*Series 8000 - 32<br />

*Series 9000 - 42<br />

*Model 9A1<br />

Features<br />

• Converts low voltage electronic switches into<br />

120 VAC<br />

• Converts low current sensors to switch 500 mA<br />

current loads<br />

• Surge suppressed input and output adds life to<br />

small sensors<br />

• In-line device, no mounting necessary<br />

• Available with wire leads or 8mm quick connect<br />

• Designed to NEMA 4 environmental protection<br />

• Low cost all molded construction<br />

Technical Data<br />

• Temperature Range: Operational from -20° to +80° C.<br />

• Supply Voltage: 120 VAC 50/60 Hz +/- 10%<br />

• Supply Current: 30 mA max. (no load/sensor)<br />

• Output Voltage: Supply voltage less 2 V<br />

• Output Current: 500 mA<br />

• Sensor Supply Current: 13.5 mA max.<br />

• Sensor Supply Voltage: 7.0 VDC (nominal)<br />

• Sensor Output Current: 6 mA min. (sinking)<br />

• Suppression: MOV<br />

• Cable: Black 24 AWG PVC<br />

• Enclosure: Glass-filled polypropolene<br />

Ordering Information<br />

Output Style<br />

1 - 9 ft Cable<br />

2 - 8mm Male to Body<br />

i L A - 1 0 0 1 3 0 0<br />

Ordering Example:<br />

iLA -10011300<br />

In-Line amplifier, 9 ft cable output,<br />

2 ft 8mm female pigtail, 120 VAC<br />

Optional mating 8mm Male<br />

Screw Terminal <strong>Connector</strong><br />

12<br />

M8 x1<br />

50<br />

43<br />

Adapts sensor cable to iLA<br />

62