Page 30 of 332<br />

SUBSET-085, Issue 2.2.2<br />

November 9, 2007<br />

4.2.2.4 Evaluation of Up-link Con<strong>for</strong>mity in the Contact Zone<br />

The results from the measurements in sub-clause 4.2.2.3.3 on page 29 (P 42DIFF ) shall be compared with the requirements<br />

in Part 1 of this Norm regarding con<strong>for</strong>mity in the contact zone. The field generated by the Balise<br />

shall be compared with the “Reference Field”. The requirement stated in Part 1 of this Norm is:<br />

• For the field generated by the Balise ± 1.5 dB.<br />

The value P 42DIFF reflects the absolute difference between the Reference Loop and the Balise. The requirement<br />

states the relative con<strong>for</strong>mity. There<strong>for</strong>e, the comparison with the requirement shall be relative.<br />

The Balise is con<strong>for</strong>m <strong>for</strong> the field generated by the Balise if:<br />

The highest P 42DIFF - the lowest P 42DIFF is less than 3 dB<br />

(P 42DIFFMAX - P 42DIFFMIN ) < 3 dB