Page 40 of 332<br />

SUBSET-085, Issue 2.2.2<br />

November 9, 2007<br />

4.2.3.2.2 Calibration Abstract<br />

This calibration procedure will give a reference value P 27RL <strong>for</strong> each measurement point, defined in clause C1 of<br />

Annex C on page 200, which shall be compared with the corresponding value P 27BA <strong>for</strong> the Balise. The reference<br />

value P 27RL is proportional to the square of the current needed <strong>for</strong> obtaining a flux level of φ d1 through the<br />

Reference Area. The current is measured by Power Meter 2 (P M2 ), subsequently compensated, and called P 27RL.<br />

The calibration procedure <strong>for</strong> one of the geometrical positions, [X = 0, Y = 0, Z = 220], shall be per<strong>for</strong>med also<br />

under other test conditions than free air, and without the 4.2 MHz Antenna. The result shall be used in subclause<br />

4.2.4 on page 47. The following test conditions specified in clause B5 of Annex B on page 185 shall be<br />

used:<br />

Debris: Salt Water, debris class (A or B) defined by the manufacturer.<br />

Clear Water, debris class (A or B) defined by the manufacturer.<br />

Iron Ore (Magnetite), debris class (A or B) defined by the manufacturer.<br />

Metallic object: Metallic plate underneath the Balise, Case 1.<br />

Steel Sleepers<br />

Other Sleepers (mounting assemblies)