17.02.2014 Views

Test Specification for Eurobalise FFFIS

Test Specification for Eurobalise FFFIS

Test Specification for Eurobalise FFFIS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Page 48 of 332<br />

SUBSET-085, Issue 2.2.2<br />

November 9, 2007<br />

4.2.4.2 Calibration of 4.2 MHz <strong>for</strong> Balise Input to Output Characteristics<br />

4.2.4.2.1 Calibration Configuration<br />

A proposed calibration set-up is shown in Figure 14 below. Clause F1 of Annex F on page 287 gives an example<br />

of suitable test equipment. If Power Meter 2 is substituted, by <strong>for</strong> instance a spectrum analyser, then the<br />

measurement bandwidth of this device shall be 1.2 MHz. The <strong>Test</strong> Antenna (item 5) and the cable from the <strong>Test</strong><br />

Antenna to Power Meter 1 (the sensor head), shall be the same as in the calibration procedure in sub-clause<br />

4.2.3.2 on page 39. See also sub-clause 4.2.1 on page 23.<br />

10.<br />

Power<br />

Meter 1<br />

P M1<br />

11.<br />

Attenuator<br />

Balun<br />

14.<br />

3.<br />

RF<br />

Amplifier<br />

Reference Loop<br />

Interface ‘A’<br />

7.<br />

2.<br />

Attenuator<br />

50 Ω<br />

50 Ω<br />

CS<br />

27 MHz<br />

<strong>Test</strong> Antenna<br />

5.<br />

13.<br />

Signal<br />

Generator<br />

15.<br />

Power<br />

Meter 2<br />

P M2<br />

12.<br />

Filter<br />

4.2 MHz<br />

Figure 14: <strong>Test</strong> set-up <strong>for</strong> calibration of 4.2 MHz Balise Loop Current